Laserfiche WebLink
4 <br />CR <br />REX <br />MX <br />EL <br />ED <br />WAP <br />WAPWAP <br />DC <br />ACP <br />ET <br />EP <br />SA <br />THREE SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE FLOOR BOX DETAILS AND SPECIFICATIONS <br />FOR MORE INFORMATION. <br />SINGLE SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE FLOOR BOX DETAILS AND SPECIFICATIONS <br />FOR MORE INFORMATION. <br />TWO SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE FLOOR BOX DETAILS AND SPECIFICATIONS FOR <br />MORE INFORMATION. <br />FLOOR BOX / SPECIALTY WALL BOX / IN-GRADE BOX SYMBOLS <br />GROUNDGRD <br />PA PUBLIC ADDRESS <br />UNDERGROUND PULL SECTION <br />VOLTAGE DROP <br />UNINTERRUPTABLE POWER SYSTEM <br />TRANSFORMER <br />VARIABLE AIR VOLUME <br />SHORT CIRCUIT CURRENT <br />TRANSIENT VOLTAGE SURGE <br />STRUCTURED CABLING SYSTEM <br />ROOT MEAN SQUARE <br />RECEPTACLE <br />WEATHERPROOF <br />UNLESS OTHERWISE NOTED <br />VOLT AMPERES <br />RIGID GALVANIZED STEEL <br />600 VOLTS AND LESS <br />TELEPHONE AND DATA <br />REFRIGERATOR <br />VD <br />U.P.S. or UPS <br />XFMR <br />VAV <br />VA <br />V <br />W <br />WP <br />VOLTS <br />WIRE <br />U.G.P.S. <br />SCC <br />T.V.S.S. <br />SCS <br />RMS <br />REF <br />RGS <br />SQ. <br />TV <br />TC <br />TEL/DATA <br />U.O.N. <br />TYP <br />REC, RECEPT <br />SECONDARY <br />SQUARE <br />TYPICAL <br />TELEVISION <br />TIMECLOCK <br />MERCURY VAPOR <br />POWER DISTRIBUTION UNIT <br />POLY VINYL CHLORIDE <br />PLUMBING CONTRACTOR <br />PERCENT IMPEDANCE <br />NOT TO SCALE <br />NATIONAL ELECTRICAL <br />MINIMUM CIRCUIT AMPS <br />MOTOR CIRCUIT PROTECTOR <br />NON AUTOMATIC DISCONNECT <br />MANUFACTURER <br />THOUSAND CIRCULAR MILS <br />MOTOR CONTROL CENTER <br />METAL HALIDE <br />POTENTIAL TRANSFORMER <br />FURNISH, INSTALL AND CONNECT <br />OVER 600 VOLTS <br />NORMALLY OPENED <br />NORMALLY CLOSED <br />NOT IN CONTRACT <br />OWNER FURNISHED, CONTRACTOR <br />PDU <br />PVC <br />P.C. <br />%Z <br />N.T.S. <br />OFCI <br />NL <br />NO. or # <br />PC <br />PH. or ø <br />PRIMARY <br />PT <br />PROVIDE <br />P POLE <br />NUMBER <br />PHASE <br />PHOTOCELL <br />NIGHT LIGHT <br />NEMA <br />MCA <br />MIN. <br />MCP <br />MCC <br />MCM <br />NEC <br />MTD <br />MW <br />MFR. <br />MH <br />NO <br />NC <br />NF <br />NIC <br />MOUNTED <br />MICROWAVE <br />NON-FUSED <br />MINIMUM <br />MECHANICAL CONTRACTOR <br />MAXIMUM OVERCURRENT PROTECTION <br />KILOWATT HOUR <br />GROUND FAULT CIRCUIT INTERRUPTER <br />GROUND FAULT PROTECTION <br />GROUNDING ELECTRODE CONDUCTOR <br />HEATING AIR CONDITIONING <br />LONG CONTINUOUS LOAD <br />KILOVOLT AMPERES <br />HIGH PRESSURE SODIUM <br />ISOLATED GROUND <br />JUNCTION BOX <br />DEGREE KELVIN <br />HIGH INTENSITY DISCHARGE <br />HEIGHT, WIDTH, DEPTH, LENGTH <br />HAND-OFF-AUTO <br />HORSEPOWER <br />LOW PRESSURE SODIUM <br />MAIN CIRCUIT BREAKER <br />MAIN LUGS ONLY <br />HEATING, VENTILATING AND AIR <br />M.C. <br />MOCP <br />M/M <br />M <br />KWH <br />LCL <br />KW <br />KVA <br />LPS <br />MAX. <br />MCB <br />MV <br />MLO <br />MAXIMUM <br />METER MAIN <br />METER <br />KILOWATT <br />GFCI <br />GFP <br />GE or GEC <br />HACR <br />HOA <br />HVAC <br />H.,W.,D.,L. <br />HPS <br />HP <br />HID <br />I/G <br />JBOX <br />K <br />IN. or '' INCHES <br />ANNOTATIONS <br />AVERAGEAVG <br />CURRENT TRANSFORMER <br />CURRENT LIMITING FUSE <br />CONTROL POWER TRANSFORMER <br />CONDUIT ONLY, COMPLETE WITH <br />CIRCUIT BREAKER <br />COMBINATION SMOKE FIRE DAMPER <br />CURRENT LIMITING CIRCUIT BREAKER <br />DISTRIBUTION <br />ENERGY MANAGEMENT CONTROL SYSTEM <br />ELECTRICAL METALLIC TUBING <br />ELECTRIC WATER COOLER <br />ELECTRICAL NON-METALLIC TUBING <br />ELECTRICAL CONTRACTOR <br />EMERGENCY POWER OFF <br />END-OF-LINE CIRCUIT TERMINATOR <br />EQUIPMENT GROUND (GREEN) <br />EXISTING DEVICE TO REMAIN <br />EXPLOSION PROOF <br />FULL LOAD AMPS <br />EXHAUST FAN <br />DIST <br />EMS <br />EMT <br />ENT <br />EWC <br />E.C. <br />E.P.O. <br />E-O-L <br />(E) <br />EGC or EG or E/G <br />EP <br />FA or F.A. <br />FLA <br />FT or ' <br />EF <br />FEET <br />FIRE ALARM <br />C <br />C.O. <br />BR <br />BLDG <br />CB <br />CIRC., CKT. <br />CSFD <br />DIA <br />CT <br />CLF <br />CPT <br />CLCB <br />DISC <br />CONN CONNECTED <br />DIAMETER <br />DISCONNECT <br />CONDUIT <br />BUILDING <br />CIRCUIT <br />BRANCH <br />AMERICAN WITH DISABILITIES ACT <br />4" SQUARE BY 2-1/8" DEEP BOX <br />ABOVE FINISH FLOOR <br />AMPERES INTERRUPTING CAPACITY <br />AMERICAN WIRE GAUGE <br />AMP FRAME, AMP TRIP <br />AMP SWITCH, AMP FUSE <br />AUTOMATIC TRANSFER SWITCH <br />ABOVE FINISH GRADE <br />ABBREVIATIONS <br />A.F.F. <br />4S/DP <br />ADA <br />AS/AF <br />AF/AT <br />A.I.C. or AIC <br />AMP, A <br />AWG <br />ATS <br />A.F.G. <br />AMPERE <br />DATA OUTLET BOX FLUSH MOUNTED IN CEILING - MOUNT FLUSH IN FLOOR WHEN <br />INDICATED IN A FLOOR BOX SYMBOL. STUB A 1" C. TO NEAREST ACCESSIBLE CEILING <br />AND PROVIDE A BUSHING. <br />COMBINATION TELEPHONE AND DATA OUTLET BOX FLUSH MOUNTED IN CEILING - <br />MOUNT FLUSH IN FLOOR WHEN INDICATED IN A FLOOR BOX SYMBOL. <br />TELEPHONE / DATA SYMBOLS <br />SFD SMOKE FIRE DAMPER <br />NATS <br />NATIONAL ELECTRICAL CODE <br />AUTHORITY HAVING JURISDICTIONAHJ <br />CEC CALIFORNIA ELECTRICAL CODE <br />INTERMEDIATE DISTRIBUTION FRAMEIDF <br />MAIN DISTRIBUTION FRAMEMDF <br />BDF BUILDING DISTRIBUTION FRAME <br />SHEET METAL AND AIR COND.SMACNA <br />THOUSAND CIRCULAR MILSKCMIL <br />CONTRACTOR'S NAT'L ASSOC. <br />(SYMMETRICAL) CONDITIONING <br />MANUFACTURER'S ASSOCIATION <br />INSTALLED <br />SUPPRESSION <br />PULLSTRING <br />REFRIGERATION <br />DETAIL CALLOUT, "3" INDICATES DETAIL NUMBER "E-1" INDICATES SHEET NUMBER. <br />PLAN NOTE REFERENCE, REFER TO NOTES ON SHEET, OR AS DIRECTED. <br />REVISION REFERENCE. <br />DATA OUTLET BOX, WALL MOUNTED. STUB A 1" C. TO NEAREST ACCESSIBLE CEILING <br />AND PROVIDE A BUSHING. 4S/DP MINIMUM WITH SINGLE GANG RING. <br />COMBINATION TELEPHONE AND DATA OUTLET BOX, WALL MOUNTED. STUB A 1" C. TO <br />NEAREST ACCESSIBLE CEILING AND PROVIDE A BUSHING. 4S/DP MINIMUM WITH <br />SINGLE GANG RING. <br />DATA OUTLET BOX, WALL MOUNTED 6-INCHES ABOVE COUNTER OR SPLASH. STUB A <br />1" C. TO NEAREST ACCESSIBLE CEILING AND PROVIDE A BUSHING. 4S/DP MINIMUM <br />WITH SINGLE GANG RING. <br />COMBINATION TELEPHONE AND DATA OUTLET BOX, WALL MOUNTED 6-INCHES ABOVE <br />COUNTER OR SPLASH. STUB A 1" C. TO NEAREST ACCESSIBLE CEILING AND PROVIDE <br />A BUSHING. 4S/DP MINIMUM WITH SINGLE GANG RING. <br />(R) <br />(ER) <br />DENOTES RELOCATED DEVICE <br />EXISTING DEVICE TO BE RELOCATED <br />(D)EXISTING DEVICE TO BE DEMOLISHED <br />CBC CALIFORNIA BUILDING CODE <br />LIGHTINGLTG, LTS <br />LINEAR FEETLF, L.F. <br />INTERNATIONAL BUILDING CODEIBCBJ BONDING JUMPER <br />SSBJ SUPPLY SIDE BONDING JUMPER <br />SBJ SYSTEM BONDING JUMPER <br />MAIN BONDING JUMPERMBJ <br />LOCATION. <br />DIMMING PANEL CONTROL STATIOND.P.C.S. <br />INTEGRATED DIMMING CONTROL PANELI.D.C.S. <br />SHORT CIRCUIT CURRENT RATINGSCCR <br />AVAILABLE FAULT CURRENTA.F.C. or AFC <br />DISTRIBUTED ANTENNA SYSTEMDAS <br />LOW VOLTAGELV <br />TELECOMMUNICATIONS PATHWAYS AND GENERAL <br />NOTES: <br />INTERIOR WIRELESS ACCESS POINT OUTLET DATA OUTLET(S) AND 1" CONDUIT WITH <br />CONDUCTORS TO NEAREST ACCESSIBLE CEILING SPACE, OR AS SHOWN ON THE FLOOR <br />PLANS. WHEN INSTALLED AT ACCESSIBLE CEILING TILE LOCATIONS, PROVIDE WAP OUTLET <br />ABOVE ACCESSIBLE CEILING TILE AND MOUNTED TO THREADED ROD ATTACHED TO <br />STRUCTURE ABOVE. REFER TO FACEPLATE DETAILS FOR ADDITIONAL INFORMATION. WAP <br />ELECTRONICS AND ANTENNA ARE CFCI. <br />EXTERIOR WIRELESS ACCESS POINT OUTLET DATA OUTLET(S) WITH FLUSH 4S DEEP BOX, <br />WEATHERPROOF BLANK PLATE, AND 1" CONDUIT WITH CONDUCTORS TO NEAREST <br />ACCESSIBLE CEILING SPACE, OR AS SHOWN ON THE FLOOR PLANS. REFER TO FACEPLATE <br />DETAILS FOR ADDITIONAL INFORMATION. WAP ELECTRONICS AND ANTENNA ARE CFCI. <br />CONTRACTOR FURNISHED, CONTRACTORCFCI <br />INSTALLED <br />OWNER FURNISHED, OWNEROFOI <br />INSTALLED <br />FLUSH IN GRADE PULLBOX, SIZED PER N.E.C. OR AS NOTED. <br />CONDUIT / PATHWAY / BACKBOARD SYMBOLS <br />CONCEALED TELEPHONE/DATA CONDUIT RUN, 1- INCH CONDUIT (MIN) OR AS NOTED <br />ON PLANS. SEE TABLE BELOW FOR CONDUIT SIZE VARIATIONS. <br />D3 = 2" C.D2 = 1-1/2" C.D1 = 1-1/4" C. <br />SURFACE MOUNTED, LOCKABLE TERMINAL CABINET WITH TERMINAL STRIPS AS <br />REQUIRED. <br />PAINTED TELEPHONE TERMINAL BACKBOARD SIZED AS NOTED, REFER TO TELECOM <br />SYSTEM GROUND DETAIL. <br />TELECOM GROUND BUS BAR, REFER TO TELECOM SYSTEM GROUND DETAIL AND <br />SPECIFICATIONS. <br />CONCEALED CONDUIT UNLESS OTHERWISE NOTED, SIZE AS NOTED ON PLANS <br />CONDUIT CONCEALED BELOW GRADE, SIZE AS NOTED ON PLANS <br />CONDUIT STUB OUT, PROVIDE A BUSHING ON BOTH ENDS <br />CONDUIT CONTINUATION <br />CONDUIT CONTINUATION DOWN WALL TO FLOOR BELOW <br />CONDUIT CONTINUATION UP WALL TO FLOOR ABOVE <br />SECURITY INTRUSION ALARM SYSTEM SYMBOLS <br />RECESSED SECURITY ALARM DOOR CONTACT - SEE SPECIFICATIONS. <br />CONCEALED SECURITY ALARM CONDUIT RUN, 3/4-INCH CONDUIT (MIN). SEE TABLE BELOW FOR <br />CONDUIT SIZE VARIATIONS: <br />SA4 = 2" C.SA3 = 1-1/2" C.SA1 = 1" C. SA2 = 1-1/4" C.SA = 3/4" C. <br />ACCESS CONTROL SYSTEM TERMINAL CABINET COMPLETE WITH ALL DOOR CONTROLLERS, <br />NETWORK MODULES, TERMINALS, MODULES, EXPANDERS, POWER SUPPLIES AND <br />ASSOCIATED ENCLOSURES, ETCETERA., SEE SPECIFICATIONS FOR ADDITIONAL <br />REQUIREMENTS. <br />CARD READER, WALL MOUNTED. STUB A 3/4"C TO NEAREST ACCESSIBLE CEILING AND <br />PROVIDE BUSHING. PROVIDE FLUSH 4S/DP MINIMUM WITH SINGLE GANG RING. PROVIDE <br />MULLION MOUNTED CARD READER WHEN REQUIRED. <br />ELECTRIC POWER TRANSFER HINGE - PROVIDED BY DOOR HARDWARE CONTRACTOR. <br />ELECTRIC HINGE - PROVIDED BY DOOR HARDWARE CONTRACTOR. <br />INTEGRATED REQUEST TO EXIT SENSOR - PROVIDED BY DOOR HARDWARE CONTRACTOR. <br />REQUEST TO EXIT MOTION SENSOR - SEE SPECIFICATIONS. <br />ELECTRIFIED LOCKSET - PROVIDED BY DOOR HARDWARE CONTRACTOR. <br />ELECTRIFIED PANIC HARDWARE - PROVIDED BY DOOR HARDWARE CONTRACTOR. <br />HOMERUN CONDUIT TO LOCATION NOTED ON FLOOR PLANS <br />D <br />2 <br />3 <br />E-1 <br />10. <br />7. <br />6. <br />5. <br />4. <br />3. <br />2. <br />1.CONDUITS SHALL (a) CONTAIN NO CONTINUOUS SECTIONS LONGER THAN 30M (98 FT.), AND (b) <br />CONTAIN NO MORE THAN (2) 90° BENDS OR (1) REVERSE BEND WITHOUT INSTALLING A PULL BOX. <br />SPLIT CONDUITS IN PLACE OF PULL BOXES ARE UNACCEPTABLE. <br />CONDUITS SHALL CONTAIN PLASTIC OR NYLON PULL TAPE RATED AT 200 LBS. WITH A MINIMUM OF 5 <br />FEET OF EXTRA PULL TAPE COILED AT EACH END. <br />CONDUIT BEND RADIUS SHALL BE (a) A MINIMUM OF 6 TIMES THE INTERNAL CONDUIT DIAMETER <br />FOR CONDUITS 2-INCHES IN DIAMETER OR LESS, AND (b) 10 TIMES THE INTERNAL CONDUIT <br />DIAMETER FOR CONDUITS MORE THAN 2-INCHES IN DIAMETER. <br />TERMINATE CONDUIT STUBS AND SLEEVES THAT PROTRUDE THROUGH STRUCTURAL FLOORS <br />2-INCHEST TO 3-INCHES ABOVE THE FLOOR SURFACE. <br />INSTALL BUSHINGS OR BELL ENDS AS REQUIRED ON ALL CONDUITS. <br />FLEX CONDUIT IS UNACCEPTABLE FOR USE AS A COMMUNICATIONS CONDUIT EXCEPT AT SEISMIC <br />JOINTS AND/OR IF APPROVED IN WRITING BY THE ENGINEER. <br />ALL UNDER SLAB OR IN-SLAB CONDUITS SHALL BE INSTALLED IN A MANNER THAT PREVENTS <br />WATER INFILTRATION OF THE CONDUIT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE <br />GROUND WATER, RAIN WATER OR CONSTRUCTION WATER IS PREVENTED FROM ENTERING AND/OR <br />REMOVED FROM THE CONDUITS PRIOR TO PLACEMENT OF COMMUNICATIONS CABLES. SEE <br />ELECTRICAL SPECIFICATIONS, DETAILS AND PLANS FOR ADDITIONAL CONDUIT SEALING <br />REQUIREMENTS. <br />ALL PULL BOXES SHALL BE SIZED AND INSTALLED PER ANSI-TIA-569-C. PULL BOXES FOR IN/UNDER <br />SLAB CONDUIT RUNS ARE NOT PERMITTED UNLESS OTHERWISE NOTED. PULL BOXES FOR <br />OVERHEAD CONDUIT RUNS SHALL BE LOCATED ABOVE ACCESSIBLE CEILINGS WITHIN THE <br />ACCESSIBLE CEILING SPACE AND SUPPORTED INDEPENDENTLY FROM THE STRUCTURE AND <br />CONDUIT SUPPORTS. PULL BOXES FOR ROOF MOUNTED OR EXTERIOR ABOVE GRADE <br />APPLICATIONS SHALL BE NEMA 3R RATED. PULL BOXES SHALL BE SIZED ACCORDING TO THE <br />FOLLOWING: <br />11. <br />PROVIDE LABELING OF EACH CONDUIT PER GENERAL ELECTRICAL SPECIFICATIONS. <br />12. <br />CONDUIT(S) SHALL EXIT A PULL BOX ON THE WALL OPPOSITE THE WALL ENTERED. <br />PROVIDE INTERNAL/EXTERNAL GAS AND WATER TIGHT MECHANICAL SEALING/PLUGGING OF EACH <br />UNDERGROUND BUILDING ENTRY CONDUIT AS SPECIFIED ELSEWHERE IN THE DRAWINGS AND <br />SPECIFICATIONS. <br />13. <br />WHERE OPEN CEILINGS OCCUR CONDUCTORS SHALL BE INSTALLED INSIDE SURFACE MOUNTED <br />RACEWAY (CONDUIT). PROVIDE ALL SURFACE MOUNTED RACEWAY, CONDUITS AND CONDUIT <br />SLEEVES WHETHER OR NOT SHOWN ON THE PLAN DRAWINGS. THIS APPLIES TO ALL LOW VOLTAGE <br />AND SIGNAL SYSTEMS CONDUCTORS INCLUDING DATA, TELEPHONE, SECURITY, PUBLIC ADDRESS, <br />CLOCKS, AUDIO VISUAL, CATV, SURVEILLANCE CAMERAS, FIRE ALARM, BMS/EMS, ETCETERA. <br />14. <br />WHERE INACCESSIBLE CEILINGS OCCUR CONDUCTORS SHALL BE INSTALLED INSIDE CONDUIT <br />RACEWAY. PROVIDE ALL CONDUITS AND CONDUIT SLEEVES W HETHER OR NOT SHOWN ON THE <br />PLAN DRAWINGS. THIS APPLIES TO ALL LOW VOLTAGE AND SIGNAL SYSTEMS CONDUCTORS <br />INCLUDING DATA, TELEPHONE, SECURITY, PUBLIC ADDRESS, CLOCKS, AUDIO VISUAL, CATV, <br />SURVEILLANCE CAMERAS, FIRE ALARM, BMS/EMS, ETCETERA. <br />9. <br />8. <br />ALL PULL BOXES INSTALLED ON TOP OF ROOFS OR ATTACHED TO CANOPIES SHALL BE RATED <br />NEMA-3R OR NEMA-4. PROVIDE QUANTITY AND SIZE OF PULL BOXES AS REQUIRED TO COMPLY <br />WITH THESE GENERAL PATHWAY NOTES. PAINT BOXES TO MATCH SURROUNDING SURFACES. <br />ALL CONDUITS INSTALLED ON EXTERIOR OF BUILDINGS AND CANOPIES SHALL BE GALVANIZED. <br />PAINT ALL CONDUITS TO MATCH SURROUNDING SURFACES. <br />15. <br />ALL CONDUITS EXPOSED TO VIEW (I.E.: OPEN CEILING SPACES) SHALL BE PAINTED TO MATCH <br />SURROUNDING SURFACES. CONDUITS INSTALLED ABOVE HARD CEILINGS OR INACCESSIBLE <br />CEILINGS ARE EXEMPT FROM PAINTING. <br />16. <br />17. <br />PROVIDE SOUND STOP MATERIAL FOR ALL CONDUIT PENETRATIONS IN SOUND RATED WALL <br />ASSEMBLIES. <br />ELECTRICAL CONTRACTOR SHALL REFERENCE ALL E-SERIES, T-SERIES AND AV-SERIES SHEETS <br />FOR ADDITIONAL CONDUIT REQUIREMENTS. <br />PROVIDE ANY AND ALL CONDUIT SLEEVES AS MAY BE REQUIRED WHENEVER LOW VOLTAGE <br />CONDUCTORS PASS THROUGH AN INTERIOR OR EXTERIOR WALL, FLOOR, OR ANY STRUCTURAL <br />ASSEMBLY. PROPERLY FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES PER THE <br />NEC AND ELECTRICAL SPECIFICATIONS. <br />18. <br />19. <br />PORPB <br />1" <br />2" <br />3" <br />4" <br />4" <br />8" <br />12" <br />15" <br />16" <br />36" <br />48" <br />60" <br />3" <br />4" <br />5" <br />8" <br />2" <br />5" <br />6" <br />8" <br />FOR OTHER CONDUIT SIZES REFER TO ANSI/TIA 569 C TABLE 12. LATEST PUBLISHED EDITION. <br />CONDUIT <br />SIZE <br />LENGTH DEPTHWIDTH WIDTH INCREASE PER <br />ADDITIONAL CONDUIT <br />WP <br />H <br />OR <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />04/09/2025 <br />T0.1 <br />TECHNOLOGY <br />LEAD SHEET <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />DESCRIPTION DATE <br />1 ASI #1 4/9/25 <br />SHEET INDEX <br />Sheet <br />Number Sheet Name <br />T0.1 TECHNOLOGY LEAD SHEET <br />T11.1 TECHNOLOGY DEMOLITION FLOOR PLAN <br />T11.2 TECHNOLOGY FLOOR PLAN <br />T40.3 TECHNOLOGY RCP <br />T40.8 TECHNOLOGY ENLARGED PLANS <br />T52.1 TECHNOLOGY DETAILS <br />T52.2 TECHNOLOGY DETAILS <br />T52.3 TECHNOLOGY BLOCK DIAGRAMS <br />1 <br />1 <br />1