Laserfiche WebLink
1 <br />A B C D E F <br />2 <br />3 <br />4 <br />5 <br />1.001 1.001 <br />1.001 <br />1.002 <br />1.002 <br />1.003 <br />1.003 <br />1.004 <br />1.0051.005 <br />1.0071.006 <br />1.007 <br />1.006 1.007 <br />1.007 1.007 <br />1.0061.006 <br />1.007 <br />1.006 <br />1.006 <br />1.002 1.007 <br />1.007 <br />1.007 <br />1.009 <br />0.001 <br />11870 Pierce Street, Suite 160 <br />Riverside, California 92505 <br />951.299.4160 www.tk1sc.com <br />C O L L A B O R A T I V E <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />DATE ISSUED: <br />PROJECT NO: <br />Project Leader -BILL VOLLER <br />tk1sc Job #:B2202330.000 <br />1/8" = 1'-0" <br />Issue Date <br />P11.1 <br />PLUMBING <br />DEMOLITION <br />FLOOR PLAN <br />2022-40123 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />NE <br />W <br />H <br />O <br />P <br />E <br /> <br />L <br />I <br />B <br />R <br />A <br />R <br />Y <br />MO <br />D <br />E <br />R <br />N <br />I <br />Z <br />A <br />T <br />I <br />O <br />N <br />12 <br />2 <br /> <br />N <br />. <br /> <br />N <br />E <br />W <br />H <br />O <br />P <br />E <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SCALE: 1/8" = 1'-0"1 PLUMBING DEMOLITION FLOOR PLAN <br />KEYNOTES <br />0.001 EXISTING HOSE BIB TO REMAIN. FIELD VERIFY EXACT LOCATION. PROTECT IN <br />PLACE. <br />1.001 EXISTING 4" WASTE PIPE BELOW FLOOR. FIELD VERIFY EXACT LOCATION AND SIZE. <br />1.002 EXISTING 2" COLD WATER PIPE OVERHEAD. FIELD VERIFY EXACT LOCATION AND <br />SIZE. <br />1.003 EXISTING 1" HOT WATER PIPE OVERHEAD. FIELD VERIFY EXACT LOCATION AND <br />SIZE. <br />1.004 REMOVE EXISTING HOT WATER HEATER. PREPARE FOR RECONNECTION OF <br />REPLACEMENT UNIT UNDER RENOVATION PHASE. <br />1.005 EXISTING FLOOR CLEAN-OUT. FIELD VERIFY EXACT LOCATION. PROTECT IN PLACE. <br />1.006 REMOVE EXISTING PLUMBING FIXTURE(S); CAP PIPING IN WALL, BELOW FLOOR, <br />AND/OR ABOVE CEILING. PREPARE FOR RECONNECTION OF REPLACEMENT UNIT <br />UNDER RENOVATION PHASE. REFER TO SHEET A10.0 DEMOLITION PLAN. <br />1.007 REMOVE EXISTING FIXTURE AND ASSOCIATED PIPING. CAP BELOW FLOOR, IN WALL <br />OR ABOVE CEILING AS REQUIRED. <br />1.009 REMOVE EXISTING STOVE AND ASSOCIATED GAS CONNECTION. CAP PIPING IN WALL <br />AS REQUIRED. <br />GENERAL NOTES: <br />1.EXACT CONDITIONS AND LOCATIONS OF ALL PLUMBING PIPING NOT KNOWN, CONTRACTOR SHALL FIELD <br />VERIFY EXACT LOCATION OF PIPING BEFORE BEGINNING OF WORK. NOTIFY ARCHITECT OF ANY MAJOR <br />DISCREPANCIES IN PLANS BEFORE STARTING OF WORK. <br />2.ALL COLD WATER AND HOT WATER PIPES THAT ARE BACK TO BE DISCONNECTED FROM FIXTURES SHALL <br />BE PULLED BACK CLOSE TO MAIN AS POSSIBLE UNLESS USED FOR NEW FIXTURES IN ITS PLACE. <br />3.CONTRACTOR SHALL FIELD VERIFY EXISTING PIPING CONDITIONS WITHIN THE ROOM OR VICINITY WHERE <br />NEW WORK IS PERFORMED AND NOTIFY ARCHITECT OF RECOMMENDED REPAIRS THAT ARE BEYOND <br />SCOPE OF WORK. <br />4.PROTECT IN PLACE ALL EXISTING TO REMAIN PIPING AND CONSTRUCTION ELEMENTS. <br />DESCRIPTION DATE <br />2 ASI #2 06/13/23 <br />3 ASI #3 07/03/25 <br />3 <br />3