My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3217 S Timber St - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Timber St
>
3217 S Timber St
>
3217 S Timber St - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2026 5:00:23 AM
Creation date
2/18/2026 5:00:08 AM
Metadata
Fields
Template:
Plan
Permit Number
20186822
20187276
101124931
Full Address
3217 S Timber St
Street Number
3217
Street Direction
S
Street Name
Timber
Street Suffix
St
Document Relationships
101124931 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Timber St\3217 S Timber St
20186822 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Timber St\3217 S Timber St
Text box
ID:
1
Creator:
Import Agent
Created:
2/18/2026 5:00 AM
Modified:
2/17/2026 8:56 AM
Text:
Revision to 20186822 (iss on 10/17/2025) Rev # 20187276 APPROVALS: ELECT - M. Smith
Stamp
ID:
1
Creator:
Import Agent
Created:
2/18/2026 5:00 AM
Modified:
2/17/2026 8:56 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />PA <br />M <br />E <br />L <br />A <br /> <br />L <br />A <br />C <br />E <br />Y <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />32 <br />1 <br />7 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />T <br />I <br />M <br />B <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />, <br /> S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />ANSI B <br />11" X 17" <br />DATEDESCRIPTION <br />REVISIONS <br />PROJECT NAME & ADDRESS <br />DATE:07/18/2025 <br />DRAWN BY <br />ESR <br />07/18/2025INITIAL DESIGN <br />POWER UP <br />SOLUTIONS LLC <br />C10 ELECTRICAL #1113778 <br />3855 ATHERTON RD, <br />ROCKLIN, CA 95765 <br />permit@gopowerupsolutions.com <br />08/21/2025CLIENT COMMENT A <br />09/08/2025CLIENT COMMENT B <br />PROJECT DATA GENERAL NOTES VICINITY MAP <br />PROJECT <br />ADDRESS <br />3217 SOUTH TIMBER STREET, <br />SANTA ANA, CA 92707 <br />OWNER:PAMELA LACEY <br />SCOPE: <br />HOUSE PHOTO <br />COVER SHEET <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />PV-1 COVER SHEET <br />PV-2 PLOT PLAN WITH ROOF PLAN <br />PV-3 ROOF PLAN & MODULES <br />PV-4 ELECTRICAL PLAN <br />PV-4A ELEVATION PLAN <br />PV-5 ATTACHMENT DETAIL <br />PV-6 ELECTRICAL LINE DIAGRAM <br />PV-7 WIRING CALCULATION <br />PV-8 LABELS <br />PV-9 PLACARD <br />PV-10 MICRO INVERTER CHART <br />PV-11+EQUIPMENT SPECIFICATIONS <br />PV-1 <br />AUTHORITIES HAVING JURISDICTION: <br />BUILDING: CITY OF SANTA ANA <br />ZONING: CITY OF SANTA ANA <br />UTILITY: SCE <br />PROJECT TO COMPLY WITH THE FOLLOWING: <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA FIRE CODE <br />ASCE 7-16 <br />DESIGNER:ESR <br />PARCEL ID:41028341 <br />1.ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED. <br />2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE 2022 CEC. <br />3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL <br />OPERATION. <br />4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OR <br />OTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY. <br />5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS <br />"CAUTION: SOLAR CIRCUIT" EVERY 10FT. <br />6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER CEC CODE 240.24. <br />7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE <br />PROVIDED. PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE <br />ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED <br />AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE <br />CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTING <br />GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. <br />8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. <br />9.PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. <br />10.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE. <br />WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE. <br />11.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV <br />RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE CEC AND AHJ. <br />12.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE LISTED FOR THIS USE [ CEC 690.35(G)]. <br />13.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BY <br />QUALIFIED PERSONS [ CEC 690.4(C)] <br />14.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND <br />SWITCHES. <br />15.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. <br />16.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH CEC 690.41. <br />17.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITH <br />CEC 690.12 <br />18.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEM <br />EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [ CEC 690.13(A)] <br />19.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH CEC 690.31 <br />20.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER CEC 110.26(A)(1), 110.26(A)(2) AND 10.26(A)(3). <br />21.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITH <br />UL1703 <br />22.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER CEC <br />EXISTING SCOPE: <br />8.800 KW DC ROOF MOUNT <br />SOLAR PV SYSTEM WITH <br />32 REC SOLAR: REC275TP BLK 275W PV <br />MODULES WITH <br />32 EXISTING SOLAREDGE: POWER <br />OPTIMIZERS <br />01 SOLAREDGE SE7600A-US (240V) <br />INVERTER <br />A <br />A <br />Signed 9/10/2025 <br />10 MODULES-ROOF MOUNTED - 4.050 KW DC, 3.800 KW AC <br />3217 SOUTH TIMBER STREET, SANTA ANA, CA 92707 <br />SHEET INDEX <br />CODE REFERENCES <br />4.050 KW DC ROOF MOUNT <br />SOLAR PV SYSTEM WITH <br />10 HANWHA SOLAR:EB SH <br />Q.PEAK_DUO_BLK_ML-G10+ 405W MONO <br />MODULES WITH <br />10 ENPHASE EB SH IQ8HC-72-M-DOM-US <br /> (240V) [SI1-SB] MICROINVERTERS <br />(1) TESLA POWERWALL 3 [(1707000-XX-Y) <br />(240V)] INTEGRATED SOLAR & BATTERY <br />13.5kWH [SI1-SB] DERATE MAIN <br />BREAKER FROM 200A RATED TO 175A
The URL can be used to link to this page
Your browser does not support the video tag.