My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1621 S Diamond St Unit #2 - Plan (2)
PBA
>
Building
>
ProjectDox
>
D
>
Diamond St
>
1621 S Diamond St Unit# 2
>
1621 S Diamond St Unit #2 - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2026 5:00:21 AM
Creation date
2/18/2026 5:00:08 AM
Metadata
Fields
Template:
Plan
Permit Number
20187348
101125675
Full Address
1621 S Diamond St Unit# 2
Street Number
1621
Street Direction
S
Street Name
Diamond
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV-4A <br />DATE: 01/13/2026 REV E <br />AHJ: <br />APN: 40824215 <br />SANTA ANA CITYSCALE: <br />SHEET SIZE: 11" x 17" <br />TEMPLATE V2.0 <br />PREPARED BY: <br />HIGH LINE DESIGNS <br />SCOTT TOYAMA <br />STARS CONSTRUCTION SERVICES INC <br />6022 WESTERN AVE <br />BUENA PARK, CA 90621 <br />714.262.3929 <br />HUY THIEU NGUYEN <br />C10 #833971 <br />ELECTRICAL <br />CALCULATIONS <br />NTS <br />INVERTER OUTPUT CALCULATIONS & 705.12 COMPLIANCE <br />ELECTRICAL NOTES (APPLICABILITY BASED ON SCOPE OF WORK) <br />ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250. A SUPPLEMENTAL <br />GROUND ROD WILL BE DRIVEN IN ACCORDANCE WITH CEC 250.53(A)(3) IF THE EXISTING GROUND ROD HAS A RESISTANCE TO <br />EARTH THAT IS GREATER THAN 25 OHMS. <br />IF ANY EXISTING LOAD CONDUCTORS ARE EXTENDED BY MORE THAN 6', AFCI PROTECTION WILL BE PROVIDED PER CEC <br />210.12(D). <br />PER CEC 690.47(A) PV SYSTEMS THAT ARE NOT SOLIDLY GROUNDED, THE EQUIPMENT GROUNDING CONDUCTOR FOR THE <br />OUTPUT OF THE PV SYSTEMS SHALL BE PERMITTED TO BE THE CONNECTION TO GROUND FOR GROUND-FAULT PROTECTION <br />AND EQUIPMENT GROUNDING OF THE PV ARRAY. <br />THE ESS CIRCUIT BREAKER SHALL BE SECURED IN PLACE BY AN ADDITIONAL FASTENER PER CEC 408.36(D). <br />NO SINGLE BACK-UP LOAD WILL BE LARGER THAN THE MAXIMUM CONTINUOUS OUTPUT OF THE ESS PER CEC 710.15(A). <br />AS-BUILT CHANGES TO THE ABOVE WIRING ARE PERMISSIBLE AS LONG AS SUBSITUTIONS ARE CODE COMPLIANT. FOR EXAMPLE, <br />APPROPRIATELY SIZED NM-B MAY BE USED FOR MICROINVERTER OUTPUT CIRCUITS IF INSTALLED IN ACCORDANCE WITH CEC <br />ARTICLE 334, OR MC CABLE MAY BE USED FOR DC SOLAR STRINGS IF INSTALLED IN ACCORDANCE WITH CEC ARTICLE 330. <br />ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT & HOLD A MINIMUM NEMA 3R RATING, INCLUDING ALL ROOF MOUNTED <br />TRANSITION BOXES AND SWITCHES. CONDUCTORS EXPOSED TO WET CONDITIONS SHALL BE SUITABLE FOR USE IN WET <br />CONDITIONS PER CEC 310.10(C). <br />ALL TERMINAL TEMPERATURES OF EQUIPMENT WILL BE VERIFIED TO BE RATED FOR 75°C, OR THE WIRE WILL NEED TO BE <br />RESIZED USING THE 60°C TERMINAL TEMPERATURE RATINGS FOR 100A OR LESS. <br />ALL NM-B SHALL BE INSTALLED AND PROTECTED PER CEC 334, AND ALL SER CABLE SHALL BE INSTALLED AND PROTECTED PER <br />CEC 338. <br />ALL ROOFTOP RACEWAYS AND CABLES EXPOSED TO DIRECT SUNLIGHT WILL BE INSTALLED >7/8" ABOVE THE ROOF. <br />x <br />ID STARTING <br />LOCATION FINAL LOCATION UNGROUNDED <br />CONDUCTORS <br />NEUTRAL <br />CONDUCTOR <br />EQUIPMENT <br />GND CONDUCTOR <br />CONTROL <br />WIRE <br />TERM. <br />TEMP. <br /># OF <br />CCC ASHARE 2% HIGH TEMP.CCC <br />ADJUSTMENT <br />AMBIENT TEMP <br />CORR.90°C RATING DERATED AMP. <br />TERM. <br />TEMP. <br />RATING <br />OCPD CONDUIT CONDUIT <br />FILL LENGTH LOAD VOLTAGE VOLTAGE <br />DROP <br />1 STRING JUNCTION BOX (2) 10 AWG, PV WIRE, <br />CU N/A (1) 6 AWG, SOLID <br />BARE, CU -- 75°C 2 31°C 20.0A N/A FREE AIR N/A 8FT 10.4A 86.22V 0.25% <br />2 JUNCTION BOX INVERTER (4) 10 AWG, THWN-2, <br />CU N/A (1) 10 AWG, THWN-2, <br />CU -- 75°C 4 31°C 35.0A N/A 0.75" EMT 19.09% 18FT 10.4A 86.22V 0.56% <br />3 INVERTER NON-FUSED AC <br />DISCONNECT <br />(2) 8 AWG, THWN-2, <br />CU <br />(1) 8 AWG, THWN-2, <br />CU <br />(1) 10 AWG, THWN-2, <br />CU -- 75°C 2 31°C 50.0A 40A 0.75" EMT 23.86% 25FT 25.0A 240V 0.41% <br />4 NON-FUSED AC <br />DISCONNECT ADU SUBPANEL (2) 8 AWG, THWN-2, <br />CU <br />(1) 8 AWG, THWN-2, <br />CU <br />(1) 10 AWG, THWN-2, <br />CU -- 75°C 2 31°C 50.0A 40A 0.75" EMT 23.86% 5FT 25.0A 240V 0.08% <br />x = <br />x x = <br />x 0.96 40.0Ax =1 <br />N/AN/A N/A N/A <br />1 55.0A <br />INVERTER <br />OUTPUT CIRCUIT INVERTER OR ESS <br /># OF <br />INVERTERS / <br />ESS <br />CONTINUOUS <br />OUTPUT <br />125% SAFETY <br />FACTOR <br />TOTAL <br />BACKFEED <br />MINIMUM <br />BREAKER <br />SIZE <br />#1 GROWATT 6KW 1 25.00A 125% 31.25A 40A <br />PANEL 705.12 COMPLIANCE BUSBAR <br />OCPD <br />PROTECTING <br />PANEL <br />BUSBAR X <br />120% <br />MAX <br />GENERATION <br />BACKFEED <br />MSP 705.12(B)(3)(2)200A 200A 240A 40A <br />ADU SUBPANEL 705.12(B)(3)(2)125A N/A N/A N/A <br />HOUSE SUBPANEL 705.12(B)(3)(3)125A N/A N/A N/A <br />38.4A <br />52.8A <br />x x =1 55.0A <br />0.96 <br />0.96 52.8A <br />DIAMOND ADU <br />1621 S DIAMOND ST, UNIT 2 <br />SANTA ANA, CA 92704
The URL can be used to link to this page
Your browser does not support the video tag.