My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3600 S Susan St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Susan St
>
3600 S Susan St
>
3600 S Susan St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2026 5:00:18 AM
Creation date
2/19/2026 5:00:10 AM
Metadata
Fields
Template:
Plan
Permit Number
101123829
Full Address
3600 S Susan St
Street Number
3600
Street Direction
S
Street Name
Susan
Street Suffix
St
Document Relationships
101123829 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Susan St\3600 S Susan St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
5.0 Design Loads - Wind (Cont.): <br />5.1.2 Global Wind Shear Summary Table: <br /> <br />Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The <br />table below provides the mechanical attachment requirements for each sub-array within this project. <br /> <br /> Applied <br />Load Resisting Load Code Check <br />Sub- <br />Array <br />Name <br />FD-L = <br />Wind <br />Drag-Lift <br />(lbs.) <br />DL = <br />Total <br />Dead <br />Load <br />(lbs.) <br />Maximum Allowable <br />Mechanical <br />Attachment Strength <br />(lbs.) <br />Total MA <br />Capacity <br />(lbs.) <br />Check <br />Calculated <br />Factor of <br />Safety* <br />Check <br />1.1 8,790 11,686 650 11,050 4.31 OK <br />1.2 8,625 9,096 650 13,000 4.27 OK <br />Total:17,415 lbs.20,781 24,050 lbs. <br />Table 5.2 Summary of Mechanical Attachment Requirements <br />* Back calculated factor of safety provided to determine factor of safety applied to dead load in lieu of 0.6 in ASCE 7-16 equation 7, BACK <br />CALCULATED FACTOR OF SAFETY = (DEAD LOAD+MECHANICAL ATTACHMENT)/((.6)WIND DRAG-LIFT) <br />05/02/2025 <br />APPROVED FOR CONSTRUCTION <br />10 <br />PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 <br />(978) 688.4900 - www.panelclaw.com
The URL can be used to link to this page
Your browser does not support the video tag.