Laserfiche WebLink
www.hilti.com <br />Hilti PROFIS Engineering 3.0.73 <br />Inputdataandresultsmustbecheckedforconformitywiththeexistingconditionsandforplausibility! <br />PROFISEngineering(c)2003-2021HiltiAG,FL-9494SchaanHiltiisaregisteredTrademarkofHiltiAG,Schaan <br />1 <br />Company: <br />Address: <br />PhoneIFax: <br />Design: <br />Fasteningpoint: <br />| <br />C1-SantaAna,modifiedLine2@ColD4I.rcn <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />11/10/2021 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: HIT-HY 200 + HAS-V-36 (ASTM F1554 Gr.36) 7/8 <br />Itemnumber:notavailable(element)/2022791HIT-HY200-A <br />(adhesive) <br />Effectiveembedmentdepth:hef,act=17.500in.(hef,limit=-in.) <br />Material:ASTMF1554Grade36 <br />EvaluationServiceReport:ESR-3187 <br />IssuedIValid:5/1/2021|3/1/2022 <br />Proof:DesignMethodACI318-14/Chem <br />Stand-offinstallation:eb=0.000in.(nostand-off);t=1.000in. <br />AnchorplateR:lxxlyxt=12.500in.x8.500in.x1.000in.;(Recommendedplatethickness:notcalculated) <br />Profile:Wshape(AISC),;(LxWxTxFT)=11.900in.x8.010in.x0.295in.x0.515in. <br />Basematerial:crackedconcrete,4000,fc'=4,000psi;h=60.000in.,Temp.short/long:32/32°F <br /> Installation: hammer drilled hole, Installation condition: Water saturated <br />Reinforcement:tension:conditionA,shear:conditionA;nosupplementalsplittingreinforcementpresent <br />edgereinforcement:>No.4barwithstirrups <br />R-Theanchorcalculationisbasedonarigidanchorplateassumption. <br />Geometry [in.] & Loading [lb, in.lb] <br />2677 N Main St - <br />101110159-60 & <br />20175958-5902/07/23