Laserfiche WebLink
MU <br />L <br />L <br />E <br />R <br /> <br />C <br />O <br />M <br />P <br />A <br />N <br />Y <br />26 <br />7 <br />7 <br /> <br />N <br />. <br /> <br />M <br />A <br />I <br />N <br /> <br />S <br />T <br />. <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />1 <br />1 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />1 <br /> <br /> <br />AH <br />J <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />S <br />E <br />T <br />MA <br />I <br />N <br /> <br />S <br />T <br />. <br /> <br />T <br />O <br />W <br />N <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />PH <br />O <br />N <br />E <br />: <br /> <br />( <br />7 <br />6 <br />0 <br />) <br /> <br />5 <br />6 <br />5 <br />- <br />7 <br />2 <br />8 <br />0 <br />20 <br />0 <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br />S <br />I <br />D <br />E <br /> <br />D <br />R <br />I <br />V <br />E <br />, <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />2 <br />0 <br />0 <br />SC <br />H <br />E <br />N <br />E <br />C <br />T <br />A <br />D <br />Y <br />, <br /> <br />N <br />Y <br /> <br />1 <br />2 <br />3 <br />0 <br />5 <br />(5 <br />1 <br />8 <br />) <br /> <br />9 <br />4 <br />9 <br />- <br />0 <br />1 <br />6 <br />5 <br />10 <br />3 <br />6 <br />0 <br /> <br />C <br />A <br />R <br />E <br />Y <br /> <br />D <br />R <br />. <br />GR <br />A <br />S <br />S <br /> <br />V <br />A <br />L <br />L <br />E <br />Y <br />, <br /> <br />C <br />A <br /> <br />9 <br />5 <br />9 <br />4 <br />5 <br />(5 <br />3 <br />0 <br />) <br /> <br />8 <br />3 <br />8 <br />- <br />5 <br />3 <br />5 <br />8 <br />SC.0GENERAL INFORMATION <br /> <br />ANG. <br />B.S. <br />B.U. <br />℄. <br />DIA. <br />FB- <br />FC- <br />F.F. <br />FLG. <br />F.S. <br />GA. <br />FR- <br />H.S.B. <br />MAX. <br />I. FLG. <br />M.B. <br />⅊ <br />CENTER LINE <br />BOTH SIDES <br />BUILT-UP MEMBER <br />DIAMETER <br />FLANGE BRACE <br />STRUCTURAL BUILT-UP COLUMN <br />FINISHED FLOOR <br />FLANGE <br />STRUCTURAL BUILT-UP RAFTER <br />FAR SIDE <br />GAGE (DISTANCE BETWEEN HOLES <br />HIGH STRENGTH BOLTS <br />MIN. <br />N.S. <br />O. FLG. <br />PLATE <br />REQ'D. <br />STIFF. <br />TYP. <br />U.N.O. <br />HOLES OR MATERIAL THICKNESS) <br />INSIDE FLANGE <br />MACHINE BOLT (ASTM A307 GR. A) <br />MAXIMUM <br />FINISH SCHEDULE <br />GRAY <br />SHOP COAT <br />RED <br />SHOP COAT GALVANIZED BARE <br />(FINISH BY OTHERS)ZINC PLATED <br />STRUCTURAL FRAMES X <br />PURLIN CLIPS X <br />LIGHT GAUGE / PURLINS X <br />A325 BOLTS / NUTS / WASHERS:X <br />MISC. HARDWARE X <br />MATERIAL SPECIFICATIONS: <br />1. PRIMARY FRAMING: COLUMNS, PLATE STEEL FOR BUILT-UP BEAM, MATING PLATES, WEB STIFFENER PLATES; ASTM A572 GR 50 <br />2. SECONDARY FRAMING: GALVANIZED 16GA, 15GA. 14GA, 13GA, 12GA, ASTM A653 G90, GRADE 55, MIN. YIELD 55 KSI. <br />3. BRACING: ANGLES, ASTM A36, MIN. YIELD 36 KSI. <br />4. MINOR PLATES: PURLIN CONNECTION PLATES, ANGLE BRACE PLATES, ETC.: ASTM A36. <br />5. BOLTS: HIGH STRENGTH BOLTS, ASTM A325-N, HIGH STRENGTH WASHERS, ASTM F436 UNDER TURNING ELEMENT, HIGH <br />STRENGTH NUTS ASTM A563 (LUBRICATED). MACHINE BOLTS, ASTM A307. <br />6. ROD BRACING TO BE SOLID ROUND BAR, ASTM A36. <br />CODES & SPECIFICATIONS: <br />THE DESIGN OF THIS STRUCTURE IS IN COMPLIANCE WITH THE AEC SPECIFICATIONS AND STANDARDS, <br />UTILIZING THE PERTINENT PROVISIONS AND RECOMMENDATIONS OF THE FOLLOWING CODES. <br />1. CALIFORNIA BUILDING CODE, 2019 EDITION (CBC 2019). <br />2. AMERICAN INSTITUTE OF STEEL CONSTRUCTION, FOURTEENTH EDITION (AISC 360-10 & AISC 341-10). <br />3. AMERICAN IRON AND STEEL INSTITUTE, 2012 EDITION (AISI S100-12/S2-10). <br />4. METAL BUILDING MANUFACTURERS ASSOCIATION, 2012 EDITION (MBMA, 2012). <br />5. AMERICAN WELDING SOCIETY, STRUCTURAL WELDING CODE (AWS D1.1, 2010). <br />6. AMERICAN CONCRETE INSTITUTE, 14TH EDITION (ACI 318-14) <br />INSPECTIONS: <br />1. SHOP WELDING COMPLETED IN AN ICC CERTIFIED SHOP DOES NOT REQUIRE SPECIAL INSPECTION. NO FIELD WELDING IS <br />REQUIRED. HOWEVER, IF ANY FIELD WELDING IS REQUIRED DUE TO ANY FIELD MODIFICATIONS, SPECIAL INSPECTION IS <br />REQUIRED. <br />2. SPECIAL INSPECTION IS REQUIRED FOR HIGH STRENGTH BOLTS. THE TURN OF THE NUT METHOD OF TIGHTENING IS <br />RECOMMENDED, UNDER THE SUPERVISION OF AN INDEPENDENT TESTING LABORATORY. ALTERNATE METHODS OF <br />TIGHTENING MAY BE USED AS PERMITTED IN THE SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS <br />(AISC FOURTEENTH EDITION). <br />3. BOLTED CONNECTIONS USING A307 BOLTS DO NOT REQUIRE SPECIAL INSPECTION <br />4. PIER EXCAVATION, REBAR PLACEMENT, COLUMN EMBEDMENT, AND CONCRETE COMPRESSION TESTING REQUIRED <br />SPECIAL BOLTING CONNECTION INSPECTION REQ. (MADE WITH A325 BOLTS): <br />1. PRE-TENSIONING OF A325 BOLTS IS REQUIRED ON PRIMARY FRAMING, BOLTED BRACING, AND STRUT <br />CONNECTIONS IF LOCATED IN SEISMIC PERFORMANCE/DESIGN CATEGORY "D", "E" OR "F". PRE-TENSIONING <br />OF 1/2" DIA. A325 BOLTS ON SECONDARY CONNECTIONS IS NOT REQUIRED (SNUG-TIGHT IS ADEQUATE). <br />2. SLIP CRITICAL CONNECTIONS ARE NOT REQUIRED. <br />3. HIGH STRENGTH BOLTS MAY BE REPLACED WITH TENSION CONTROLLED HIGH STRENGTH BOLTS OF THE <br />SAME SIZE AND GRADE. TENSION CONTROLLED BOLTS DO NOT REQUIRE TURN OF NUT INSPECTION. THESE <br />BOLTS SHALL STILL BE PRE-TENSION. <br />DESIGN LOADS: <br />THIS STEEL BUILDING IS DESIGNED UTILIZING THE FOLLOWING LOADS, IN COMPLIANCE WITH THE PERTINENT <br />PROVISIONS OF THE CALIFORNIA BUILDING CODE, 2019 EDITION (CBC 2019). <br />ALL ACCESSORIES SUCH AS DOORS, WINDOWS, ETC. SUPPLIED BY OTHERS MUST BE DESIGNED AS <br />STRUCTURAL COMPONENTS IN ACCORDANCE WITH THE WIND LOAD PROVISIONS OF THE APPLICABLE CODES <br />AND SPECIFICATIONS REFERENCED ON THIS PAGE. <br />THE BUILDER AND/OR THE ENGINEER OF RECORD MUST CONFIRM THAT THE FOLLOWING LOADS MEET THE <br />REQUIREMENTS OF THE LOCAL BUILDING DEPARTMENT. AEC AND THE UNDERSIGNED ARE NOT THE "ENGINEER <br />OF RECORD" FOR THE ENTIRE PROJECT. <br />BUILDING DEAD LOAD: __________ 6.2 PSF (FRAMES, PURLINS, SOLAR PANELS + SOLAR HARDWARE, ETC.) <br />LIVE LOAD: ____________________ 12.0 PSF (SOLAR CONSTRUCTION) <br />LIVE LOAD REDUCTION ALLOWED: ____ N/A <br />SNOW LOAD, GROUND: ______________ 0.0 PSF <br />SNOW LOAD, ROOF: _________________ 0.0 PSF <br />CT ____________ N/A <br />CE ____________ N/A <br />IMPT. FACTOR: __ N/A <br />WIND LOAD, SPEED: ___ 95 MPH <br />EXPOSURE: __________ C <br />KZT: _________________ 1.0 <br />IMPT FACTOR: ________ 1.0 <br />EARTH QUAKE LOAD: <br />SEISMIC DESIGN CATEGORY: ___ D <br />SEISMIC SITE CLASS: __________ D <br />COEFF. Sds = 1.067, Ss = 1.334, S1 = 0.457 <br />FOR CANTILEVER COLUMN COEFF. R = 1.25 Ω = 1.25, SEISMIC BASE SHEAR = 33.4 kips <br />IMPT. FACTOR: ________________1.0 <br />OTHER LOADS: <br />LIVE LOAD: _________ N/A <br />DEAD LOAD: ________ N/A <br />MODULE SPECIFICATION: <br />ANGLE <br />MINIMUM <br />NEAR SIDE <br />OUTSIDE FLANGE <br />REQUIRED <br />STIFFENER <br />TYPICAL <br />UNLESS NOTED OTHERWISE <br />ABBREVIATIONS: <br />FOUNDATIONS GENERAL NOTES: <br />1. DESIGN PER 2019 CBC AND ACI318-14. <br />2. SOIL CAPACITIES BASED ON VALUES FROM SOILS REPORT BY GEO-ENGINEERING SOLUTIONS (PROJECT NUMBER 50-1326). <br />PASSIVE LATERAL CAPACITY = 400 PCF (INCREASE TO 800 PCF FOR PIERS), SKIN FRICTION = 665 PSF DOWNWARD, 530 PSF <br />UPWARD (NEGLECT UPPER FOOT). <br />3. CONCRETE TO OBTAIN A MINIMUM COMPRESSIVE STRENGTH OF FC' = 3000 PSI AT 28 DAYS. <br />4. ALL REBAR TO BE GRADE 60. <br />5. CONCRETE TO REACH 1500 PSI PRIOR TO REMOVAL OF SHORING AND/OR INSTALLATION OF BEAMS AND PURLINS. <br />6. CONCRETE TO REACH 2500 PSI PRIOR TO INSTALLATION OF SOLAR PANELS. <br />7. PIER EXCAVATION SHALL BE CLEAN OF ALL DELETERIOUS MATERIAL, INCLUDING LOOSE SOIL, PRIOR TO POURING CONCRETE. <br />DEVELOPER / MANUFACTURER: <br />DISTRIBUTED SOLAR DEVELOPMENT <br />200 HARBORSIDE DR., STE 200 <br />SCHENECTADY, NY 12305 <br />PHONE: <br />CONTACT: <br />INSTALLER: <br />RENEWABLE CONSTRUCTION SERVICES, INC. <br />605 VENTURE ST, ESCONDIDO CA 92029 <br />PHONE: (760) 206-8285 <br />CONTACT: DREW LIPPERT <br />STRUCTURAL ENGINEER: <br />APPLIED ENGINEERING CONSULTANTS, INC. <br />10360 CAREY DR., GRASS VALLEY CA, 95945 <br />PHONE: (530) 838-5358 <br />CONTACT: REX ARASHI <br />GENERAL NOTES: <br />SOLAR PANELS WILL ATTACH DIRECTLY TO METAL PURLINS; THERE WILL BE NO METAL ROOF OR DECKING <br />UNDER THE PANELS. <br />SHEET INDEX <br />SHEET #SHEET NAME <br />SC.0 GENERAL INFORMATION <br />SC.1 ROOF FRAMING PLAN <br />SC.2 STRUCTURAL DETAILS <br />MULLER COMPANY <br />GROUND SOLAR CANOPY <br /> 48'-1" 14'-0" <br /> 99'-2" | 112'-11" <br />S2 (CARPORT) <br /> II-B <br /> NO <br /> 1 <br />BUILDING INFORMATION: <br />CANOPY BUILDING WIDTH (CP1 - 2): ________ CANOPY LOW CLEAR HEIGHT: ________ <br />CANOPY BUILDING LENGTH (CP1 | CP2): _____________________ <br />1. OCCUPANCY CLASSIFICATION:____________ <br />2. TYPE OF CONSTRUCTION:____________ <br />3. SPRINKLERS:____________ <br />4. # OF STORIES:____________ <br />11/17/2021, 8:01:44 AM <br />2677 N Main St - <br />101110159-60 & <br />20175958-5902/07/23