My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180813_2118 W. 12TH - Plan (2)
PBA
>
Building
>
Plans
>
T
>
Twelfth St
>
2118 W Twelfth St
>
10180813_2118 W. 12TH - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2021 5:27:33 PM
Creation date
10/25/2020 10:39:03 PM
Metadata
Fields
Template:
Plan
Permit Number
10180813
Full Address
2118 W Twelfth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TAG DESCRIPTION <br />1 ARRAY TO JUNCTION BOX <br />2 JUNCTION BOX TO INVERTER <br />3 INVERTER TO PV METER <br />4 PV METER TO AC DISCONNECT <br />5 AC DISCONNECT TO MSP <br />6 BARE COPPER WIRE <br />7 EQUIPMENT GROUND <br />8 kQUIPMENT GROUND <br />WIRE/CONDUIT SCHEDUL: <br />CONDUCTOR TYPE/SIZE <br />#10 AWG PV WIRE <br />#10 AWG THWN-2 <br />#10 AWG THWN-2 <br />#10 AWG THWN-2 <br />#10 AWG THWN-2 <br />#8 AWG SOLID COPPER <br />#8 AWG THWN-2 <br />#8 AWG THWN-2 <br />NUMBER OF CONDUIT <br />CONDUCTORS SIZE/TYPE <br />4 N/A <br />4 *'EMT <br />3 1"EMT <br />3 j" EMT <br />3 *'EMT <br />1 N/A <br />1 *' EMT <br />1 f EMT <br />MODULE SPECIFICATION <br />NOTES MODEL NO. <br />PHONO SOLAR <br />PS300P-24/T <br />FREE AIR <br />PEAK POWER 300W <br />RATED VOLTAGE (Vmp)35.6V <br />RATED CURRENT (Imp)8.44A <br />OPEN CIRCUIT VOLTAGE (Voc)45.6V <br />SHORT CIRCUIT CURRENT (Isc)8.65A <br />INVERTER SPECIFICATION <br />GENERAL ELECTRICAL NOTES: <br />1. EQUIPMENT USED SHALL BE NEW, UNLESS OTHERWISE NOTED. <br />2. EQUIPMENT SHALL BE INSTALLED PROVIDING ADEQUATE PHYSICAL WORKING SPACE AROUND THE <br />5 PANELS 5 PANELS i EQUIPMENT AND SHALL COMPLY WITH NEC. <br />3. COPPER CONDUCTORS SHALL BE USED AND SHALL HAVE INSULATION RATING 600V, 90°C, UNLESS <br />OTHERWISE NOTED. <br />4. CONDUCTORS SHALL BE SIZED IN ACCORDANCE TO NEC. CONDUCTORS AMPACITY SHALL BE DE-RATED <br />FOR TEMPERATURE INCREASE, CONDUIT FILL AND VOLTAGE DROP. <br />5. ALL CONDUCTORS, EXCEPT USE-2, SHALL BE INSTALLED IN APPROVED CONDUITS OR RACEWAY. CONDUITS <br />SHALL BE ADEQUATELY SUPPORTED AS PER NEC. <br />6. RACKING AND MODULES ARE GROUNDE0 VIA A CONTINUOUS #10 AWG COPPER CONDUCTOR, GROUNDING <br />CLIPS, GROUNDING LUGS AND/OR BONDING JUMPERS. <br />7. LOAD SIDE INTER-CONNECTION SHALL COMPLY WITH NEC <br />8. SMOKE ALARM AND CARBON MONOXIDE DETECTORS SHALL BE LOCATED AS REQD PER SEC. R314 & R315 <br />OF THE CALIFORNIA RESIDENTIAL CODE (CRC) <br />9. ALL EQUIPMENT SHALL BE LISTED FOR THE APPLICATION, UL 1703 FOR MODULES, UL 1741 FOR INVERTERS <br />10. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM <br />11. WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ <br />LINE AND LOAD <br />12. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET <br />LOCATIONS ACCORDING TO NEC 314.15 <br />13. ALL METALLIC RACEWAYS SHALL BE BONDED AND ELECTRICALLY CONTINUOUS ACCORDING TO NEC <br />250.90,250.96 <br />14. GROUNDING BUSHINGS ARE PERMITTED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC <br />SIDE OF THE SYSTEM, NEC 250.97 <br />15. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS EXCEPT FOR SPLICES OR JOINTS AT <br />BUSBARS WITHIN LISTED EQUIPMENT, NEC 250.64(C) <br />i 11-_Li i <br />«D <br />DI 161 4. <br />INVERTER MAKE <br />INVERTER MODEL <br />MAX. DC VOLT RATING <br />MAX. AC APPARENT POWER <br />NOMINAL AC VOLTAGE <br />MAX AC CURRENT <br />ARRAY <br />NO. OF MODULE PER STRING <br />NO. OF STRINGS <br />ARRAY WATTS AT STC <br />MAX. VOLTAGE <br />UTILITY <br />Bl-DIRECTIONAL <br />ELECTRIC METER <br />EXISTING <br />MAIN SERVICE PANEL <br />125A, 240VAC, 1 PH <br />POWER ONE <br />PVI-3.0-OUTD-S-US <br />600V <br />3000W <br />240V <br />14.5A <br />DETAILS <br />5 <br />2 <br />3.0kW <br />246.4V <br />NOTE: A CENTER-FED BUS WILL <br />NOT BE USED. <br />NOTE: INTERSYSTEM BONDING <br />KIT WILL BE ACCESSIBLE <br />INSTALLED ON THE WALL NEXT <br />TO MAIN SERVICE PANEL <br />OVERHEAD <br />SERVICE <br />„23- <br />INTERACTIVE CIRCUIT BREAKER <br />WILL BE PLACED AT EXTREME\21 ocpo100AEND OF BUSS OPPOSITE UTILITY SUPPLY <br />COMBINER BOX <br />WITH 15A FUSE <br />DC INTERFACE POWER ONE PVI-3.0-OUTD-S-US <br />INTEGRATED DC 3000W, 96% CEC <br />DISCONNECT 240VAC, 14.5A AC INTERFACE <br />PV METER <br />ITRON <br />AC DISCONNECT 240VAC, <br />30A NEMA 3R, UL LISTED <br />KNIFE BLADE TYPE <br />Ll - <br />L2 <br />0 <br />V <br />r 1 <br />L "L . <br />DC+ 1 1 1 <br />2 MPPT 1 20A FUSE <br />3 MppT 2 7 -/ rm 0*r I <br />0 <br />*20A <br />0 <br />0 <br />V <br />DC- 1 <br />2 MPPT 1 <br />W <br />2 MPPT 2 <br />0 <br />V 0 <br />GND <br />N L2 Lllelolo13O1*1 <br />DC DISCONNECT' <br />25A, 600V NOTE: WHEN METALLIC CONDUIT IS USED. <br />IT MUST BE BONDED AT BOTH ENDS.-L <br />EXISTING <br />UFER GROUND PV 3 <br />4% <br />[&0-- <br />1 <br />(714) 542-0598 <br />A.J- (1/M <br />BREA, CA 92821 T: 714-676-8888 <br />11 <br />D <br />840 D SRE· at¢ey &0 4% 1
The URL can be used to link to this page
Your browser does not support the video tag.