SOLARMOUNT Technical Datasheets :1:UNI RAC <br />A HILTI GROUP COMPANY <br />SolarMount Mid Clamp <br />Part No. 302101 C, 302101 D, 302103C, 302104D, <br />302105D, 3021060 <br />Bolt <br />Mid Wa#e Ahlk 3><7 <br />C/amp \ <br />'r <br />e <br />Beam <br />Mid clamp material: One of the following extruded aluminum <br />alloys: 6005-T5, 6105-T5, 6061-T6 <br />Ultimate tensile: 38ksi, Yield: 35 ksi <br />Finish: Clear or Dark Anodized <br />Mid clamp weight: 0.050 lbs (23g) <br />Allowable and design loads are valid when components are <br />assembled according to authorized UNIRAC documents <br />Values represent the allowable and design load capacity of a single <br />mid clamp assembly when used with a SolarMount series beam to <br />retain a module in the direction indicated <br />Assemble mid clamp with one Unirac %"-20 T-bolt and one 1/7-20 <br />ASTM F594 serrated flange nut <br />Use anti-seize and tighten to 10 ft-lbs of torque <br />Resistance factors and safety factors are determined according to <br />part 1 section 9 of the 2005 Aluminum Design Manual and third- <br />party test results from an IAS accredited laboratory <br />1-00 DISTANCE - 4 .. <br />OENEEN MODULES In <br />' l#J. <br />-IT- <br />Y . <br />Dimensions specified in inches unless noted <br />Applied Load Average Allowable Safety Design Resistance <br />Direction Ultimate Load Factor,Load Factor, <br />lbs (N)lbs (N)FS lbs (N) ® <br />Tension, Y+2020 (8987)891 (3963)2.27 1348 (5994)0.667 <br />Transverse, Zi 520 (2313)229 (1017)2.27 346 (1539)0.665 <br />Sliding, Xi 1194 (5312)490 (2179)2.44 741 (3295)0.620 <br />SolarMount End Clamp <br />Part No. 302001 C, 302002C, 3020020, 302003C, <br />3020030,302004C, 3020040,302005C, 302005D, <br />302006C, 302006D, 3020070,302008C, 302008D, <br />302009C, 302009D, 302010C, 302011 C, 302012C <br />Serratec <br />Flange Ni <br />/84 <br />Y <br />-X <br />• End clamp material: One of the following extruded aluminum <br />alloys: 6005-T5, 6105-T5, 6061-T6 <br />Ultimate tensile: 38ksi, Yield: 35 ksi <br />Finish: Clear or Dark Anodized <br />End clamp weight: varies based on height: -0.058 lbs (269) <br />Allowable and design loads are valid when components are <br />assembled according to authorized UNIRAC documents <br />Values represent the allowable and design load capacity of a single <br />end clamp assembly when used with a SolarMount series beam to <br />retain a module in the direction indicated <br />Assemble with one Unirac 1/1"-20 T-bolt and one 1/1"-20 ASTM F594 <br />serrated flange nut <br />Use anti-seize and tighten to 10 ft-lbs of torque <br />Resistance factors and safety factors are determined according to <br />part 1 section 9 of the 2005 Aluminum Design Manual and third- <br />party test results from an IAS accredited laboratory <br />Modules must be installed at least 1.5 in from either end of a beam <br />- 1.5 - <br />MINIMUM <br />/ 117 <br />+E]grr r.-=1 <br />•ARIM |t T <br />WITH <br />•00"(E 1 <br />THONESS <br />p al <br />Dimensions specifi68-ilintlies-utiless-noted <br />Applied Load Average Allowable Safety Design Resistance <br />Direction Ultimate Load Factor,Loads Factor, <br />lbs (N)lbs (N)FS lbs (N) ® <br />Tension, Y+1321 (5876)529 (2352)2.50 800 (3557)0.605 <br />Transverse, Zi 63 (279)14 (61)4.58 21 (92)0.330 <br />Sliding, X*142 (630)52 (231)2.72 79 (349)0.555 <br />e <br />a