Laserfiche WebLink
1001 <br />SYMBOLS DESCRIPTION <br />01/A-2.00 <br />01 <br />A-4.00 <br />N <br />NORTH ARROW <br />ENLARGE FLOOR PLAN REFERENCE <br />01 <br />A-4.00 DETAIL SECTION <br />INTERIOR ELEVATION <br />11 5/8" <br />5" <br />DIMENSIONS <br />1 REVISION NUMBER & <br />AFF ECTED AREA <br />WINDOW TYPE22 <br />ROOM NAME ROOM NAME & NUMBER <br />IDENTIFICATION <br />1001A DOOR/OPENING IDENTIFICATION <br />SEE SCHEDULE ON A6-01 <br />A3 <br />1 <br />PART ITION <br />DESIGNATION <br />HOURLY "FIRE <br />RESISTIVE RATING" <br />IF APPLICABLE <br />PART ITION TYPE <br />PROJECT SITE <br />S HARBOR BLVD <br />S FAIRVIEW ST <br />W MACART HUR BLVD <br />SUNFLOWER AVE <br />INTERSTATE <br />405 <br />HYLAND AVE <br />SUSAN ST <br />S COAST DR <br />W LAKE CENTER DR <br />SCENIC AVE <br />N <br />A D 1 -1 1 <br />LEVEL 1 DESIGNATOR <br />LEVEL 2 DESIGNATOR (OPTIONAL) <br />SHEET TYPE DESIGNATOR <br />FLOOR LEVEL (FOR PLANS ONLY) <br />SHEET SEQUENCE NUMBER <br />LEVEL 1 DESIGNATORS <br />G GENERAL <br />H HAZARDOUS MATERIALS <br />V SURVEY / MAPPING <br />B GEOTECHNICAL <br />C CIVIL <br />L LANDSCAPE <br />S STRUCT URAL <br />A ARCHIT ECTURAL <br />I INTERIORS <br />Q EQUIPMENT <br />F FIRE PROT ECTION <br />P PLUMBING <br />M MECHANICAL <br />E ELECTRICAL <br />T SECURIT Y <br />R RESOURCES <br />X OTHER DISCIPLINES <br />Z CONTRACT OR SHOP <br />DRAWINGS <br />O OPERATIONS <br />LEVEL 2 DESIGNAT ORS (OPTIONAL) <br /> S SITE <br /> D DEMOLIT ION <br /> E ELEMENT <br /> P POWER <br /> L LIGHTING <br />SHEET TYPE DESIGNATORS <br />0 GENERAL (OPTIONAL USE AS DEMO) <br />1 PLANS <br />2 ELEVATIONS <br />3 SECTIONS <br />4 ENLARGED PLANS <br />5 DETAILS <br />6 SCHEDULES <br />7 USER DEFINED <br />8 USER DEFINED <br />9 3D VIEWS <br />OWNER'S REPRESENTATIVE: <br />KAISER FOUNDATION HEALTH PLAN INC. <br />1707 BARCELONA CIRCLE <br />PLACENTIA, CA 92870 <br />CONTACT: HEIDI R. DAVIS <br /> PROJECT MANAGER <br />E-MAIL: HEIDI.R.DAVIS@KP.ORG <br /> 562.254.9762 <br />ARCHITECT: <br />HUIT T-ZOLLARS <br />555 W 5TH ST . <br />LOS ANGELES, CA 90013 <br />CONTACT : STEPHEN WHITE, AIA, LEED AP <br /> PROJECT ARCHITECT <br />E-MAIL SWHITE@HUITT -ZOLLARS.COM <br /> 310.447.7466 <br />ELECTRICAL ENGINEER: <br />IMEG CORP <br />222 S. HARBOR BOULEVARD, SUITE 800 <br />ANAHEIM, CA 92805 <br />CONTACT: TIFFINY S. MANSOURI <br /> ELECTRICAL ENGINEER <br />E-MAIL: TIF FINY.S.MANSOURI@IMEGCORP.COM <br />PLU MBING ENGINEER: <br />ADVANCES TECHNOLOGIES CONSULTANTS <br />5755 OBERLIN DRIVE, SUITE 1212 <br />SAN DIEGO, CA 92121 <br />CONTACT: JUSTIN NGUYEN, PE <br /> PLUMBING ENGINEER <br />E-MAIL JNGUYEN@ATCONSULTANTS.NET <br />MECHANICAL ENGINEER: <br />ADVANCES TECHNOLOGIES CONSULTANTS <br />5755 OBERLIN DRIVE, SUITE 1212 <br />SAN DIEGO, CA 92121 <br />CONTACT: JUSTIN NGUYEN, PE <br /> MECHANICAL ENGINEER <br />E-MAIL JNGUYEN@ATCONSULTANTS.NET <br />STR UCTURAL ENGINEER: <br />WALTER P MOORE <br />707 WILSHIRE BOULEVARD, SUITE 2100 <br />LOS ANGELES, CA 90017 <br />CONTACT : DANIEL TRAUB, S.E. <br /> STRUCTURAL ENGINEER <br />E-MAIL: DTRAUB@WALTERPMOORE.COM <br />GENERAL NOTES <br />1.U.O.N. SPECIFIC NOTES AND DETAILS ON DRAWINGS SHALL T AKE PRECEDENCE <br />OVER GENERAL NOT ES AND TYPICAL DET AILS. SPECIFIC NOTES ON DETAILS APPLY <br />TO SIMILAR CONDITIONS. <br />2. THE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS AS <br />WELL AS THE DRAWINGS OF OTHER CONSULTANTS ARE SUPPLEMENTARY TO <br />THE ARCHITECTURAL DRAWINGS. IT SHALL BE T HE RESPONSIBILIT Y OF THE <br />GENERAL CONTRACTOR TO CHECK WITH T HE ARCHITECTURAL DRAWINGS <br />BEFORE THE INSTALLATION OF THE WORK SHOWN ON THE DRAWINGS OF <br />CONSULTANTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCIES <br />BETWEEN THE ARCHITECTURAL DRAWINGS AND THE DRAWINGS OF THE <br />CONSULTING ENGINEERS TO THE ATTENTION OF THE ARCHITECT FOR <br />CLARIFICATIONS. ANY WORK INSTALLED IN CONFLICT THE ARCHITECTURAL <br />DRAWINGS AND NOT BROUGHT TO THE ARCHITECTS ATTENTION SHALL BE <br />CORRECT ED BY THE CONTRACTOR AT THE CONTRACTORS' EXPENSE AND AT <br />NO EXPENSE TO THE OWNER OR T HE ARCHITECT. <br />3. REFERENCE TO ANY DET AIL OR DRAWING IS FOR CONVENIENCE ONLY AND DOES <br />NOT LIMIT THE APPLICATION OF SUCH A DRAWING OR DETAIL. <br />4. U.O.N. OR REFERENCED ON ARCHITECTURAL DRAWINGS, ALL DETAILS ARE TYPICAL. <br />5. THE CONTRACT DOCUMENTS INDICATED THE CONCEPT AND POT ENTIAL METHOD OF <br />EXECUTING THE WORK. FIELD MODIFICATIONS MAY BE REQUIRED AND SHALL BE <br />PART OF THE SCOPE OF WORK. <br />6. THE INTENTION OF T HE CONTRACT DOCUMENTS IS TO INCLUDE ALL <br />LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION <br />NECESSARY FOR THE COMPLET E AND PROPER EXECUTION OF THE WORK. <br />7. NO MODIFICATIONS FROM THE DOCUMENTS SHALL BE CONDUCTED <br />PRIOR TO THE APPROVAL OF THE OWNER AND ARCHITECT. <br />8. DISCREPANCIES IN DRAWINGS OR SPECIFICATIONS, OR BETWEEN <br />DRAWINGS, SPECIFICATIONS AND OR SITE CONDITIONS SHALL BE <br />REVIEWED WITH THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK. <br />9. REF ER T O STRUCT URAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR <br />EQUIPMENT ANCHORAGE, HVAC, PLUMBING, LIGHTING, COMMUNICATION, DATA AND <br />POWER REQUIREMENTS. <br />10.THE DESIGN, ADEQUACY AND SAFETY OF ERECT ION, BRACING, SHORING, TEMPORARY <br />SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. T HE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE AND PROVIDE NECESSARY <br />BRACING PRIOR TO T HE APPLICATION OF ALL SHEAR WALLS, ROOF, AND FLOOR DIAPHRAGMS, <br />AND FINISH MATERIALS. T HE CONTRACTOR SHALL BE RESPONSIBLE FOR T HE INITIATING, <br />MANUFACTURING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN <br />CONNECTION WITH THE WORK. <br />11.THE ARCHITECT AND ARCHITECT'S CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE <br />DISCOVERY,PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS <br />TO <br />HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO <br />ASBEST OS, ASBESTOS PRODUCT S,POLYCHLORINAT ED BIPHENYL (PCB) OR OTHER TOXIC <br />SUBSTANCES. <br />12.IF THE CONTRACTOR ASCERTAINS AT ANY TIME THAT REQUIREMENTS OF T HE CONTRACT <br />DOCUMENTS CONFLICT WITH, OR ARE IN VIOLATION OF APPLICABLE LAWS, CODES, <br />REGULATIONS AND ORDINANCES, THE CONTRACTOR SHALL NOT PROCEED WITH WORK IN <br />QUESTION, EXCEPT AT THE CONTRACTOR'S OWN RISK, UNTIL THE ARCHITECT HAS BEEN <br />NOT IFIED IN WRITING AND WRITTEN DETERMINATION IS MADE BY THE ARCHITECT. WHERE <br />COMPLETED OR PARTIALLY COMPLET ED WORK IS DISCOVERED TO BE IN VIOLAT ION WITH <br />APPLICABLE LAWS, CODES, REGULATIONS AND ORDINANCES, CONTRACTOR SHALL BE <br />REQUIRED TO REMOVE THAT WORK F ROM THE PROJECT AND REPLACE SUCH WORK WITH ALL <br />NEW COMPLYING WORK AT NO ADDITIONAL COST TO T HE OWNER. <br />DIMENSIONING NOTES <br />1. THE DRAWINGS REF LECT GENERAL ARRANGEMENT, DESIGN AND EXTENT OF WORK, <br />AND ARE NOT TO BE SCALED FOR MEASUREMENTS. THE DRAWINGS ARE PARTLY <br />DIAGRAMMATIC AND ARE NOT INTENDED TO BE AN EXACT REPRESENTATION OF <br />FIELD CONDITIONS OR TO SERVE AS T HE CONTRACTOR'S SHOP DRAWINGS. <br />2. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. DIMENSIONS <br />SHALL GOVERN AND LARGE SCALE DETAILS SHALL GOVERN OVER SMALLER SCALE <br />DRAWINGS. <br />3. "EXISTING", "(+/-)", "SIZE TO FIT", F.V. AND SIMILAR PHRASES REQUIRE THE CONTRACTOR <br />TO VERIFY AND COORDINATE DIMENSIONS AND CONDITIONS INDICATED IN THE <br />DRAWINGS WITH THE ACTUAL FIELD CONDITIONS. DISCREPANCIES SHALL BE REPORTED <br />TO THE ARCHITECT FOR DIRECTION ON HOW TO PROCEED. <br />4.U.O.N., DIMENSIONS ARE SHOWN TO CENTERLINE OF COLUMNS, TO FACE OF <br />CONCRET E, OR TO F ACE OF FINISH OF EXTERIOR AND INTERIOR PARTITION. ALL CEILING <br />HEIGHTS INDICATED ARE FROM FINISH OF FLOOR TO FINISH OF CEILING. <br />5. DOORS NOT DIMENSIONED AND SHOWN JAMB TIGHT SHALL BE SET 4" <br />FROM PERPENDICULAR WALL TO OUTER EDGE OF DOOR JAMB. <br />6.U.N.O., RECEPTACLES APPEARING NEXT TO EACH <br />OTHER ON THE PLAN BUT NOT DIMENSIONED SHALL BE EIGHT (8") APART <br />AS MEASURED FROM CENTERLINE TO CENTERLINE. <br />7. UNLESS OTHERWISE NOTED, RECEPTACLES SHALL BE FIFTEEN <br />(15") INCHES IN HEIGHT ABOVE THE FINISHED FLOOR (AS MEASURED <br />FROM THE RECEPTACLE CENTERLINE TO THE F LOOR DAT UM) <br />8.U.N.O., ADJACENT COVERPLATES WITH DIFFERING <br />SIZES SHALL BE CONFIGURED SO THAT T HE TOPS ALIGN AS F OLLOWS: <br />9.WHEN ADJACENT COVERPLATES ARE THE SAME SIZE, THE <br />CONFIGURATIONS SHALL BE AS FOLLOWS: <br />10.U.O.N. CEILING FIXTURES AND EQUIPMENT ARE TO BE CENTERED ON CEILING TILES <br />WHEN IN LAY-IN CEILINGS. <br />11.U.O.N. LIGHT FIXTURES ON HARD SURFACE CEILINGS SHALL BE CENTER IN THE ROOM. <br />12.U.O.N. SCONCE LIGHTING AT PLUMBING FIXTURES SHALL BE CENTER ON THE <br />FIXTURE. <br />13.ALL UNDERCABINET TASK LIGHTING SHALL BE INSTALLED AS CLOSE AS POSSIBLE TO <br />THE BACK WALL AND CENTERED BELOW THE CABINETS. <br />14. WALLS NOT DIMENSIONED SHALL ALIGN WITH EXISTING WALLS OR BE ABUTTED OR <br />APPLIED TO EXISTING WALLS PER DRAWINGS. <br />CONTRACTOR'S RESPONSIBILITY <br />1.CONTRACTOR SHALL CONTACT THE OWNER 48 HOURS IN ADVANCE OF ANY RESTRICTION OF <br />OWNER ACCESS OR UTILITY OUTAGES. AUTHORIZATION FROM OWNER TO BE RECEIVED IN <br />WRITING. <br />2.IN THE EVENT THE UTILIT Y SERVICE IS INTERRUPTED WITHOUT THE REQUIRED 48 HOURS <br />NOT ICE, THEN T HE CONTRACTOR SHALL BE FINANCIALLY LIABLE F OR ALL DAMAGES SUFFERED <br />BY THE OWNER DUE TO T HE UNAUTHORIZED INTERRUPTION. RECONNECTION SHALL BE MADE <br />IMMEDIATELY. <br />3.CONTRACTOR SHALL VISIT THE SITE TO AS TO FAMILIARIZE WITH EXISTING CONDITIONS <br />AND SATISFY THEMSELVES TO T HE NATURE AND SCOPE OF THE WORK. SUBMISSIONS OF <br />PROPOSALS SHALL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE <br />AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MAT ERIALS REQUIRED, OR FOR DIFFICULTIES <br />ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN WITH SUCH EXAMINATION WILL NOT BE <br />RECOGNIZED. <br />4.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BEGINNING WORK. <br />AT ANY TIME SHOULD CONDITIONS ARISE WHEREIN THE INTENT OF T HE DRAWINGS IS IN DOUBT <br />OR WHERE THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND FIELD CONDITIONS THE <br />ARCHITECT SHALL BE NOTIFIED IMMEDIATELY IN WRITING FOR CLARIFICATION. <br />5.THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAF ETY. <br />SAFETY OF ALL PARTIES PRESENT ON THE JOB SITE IS SOLELY THE CONTRACTOR'S <br />RESPONSIBILITY. <br />6.THE CONTRACTOR SHALL HAVE FULL RESPONSIBILITY AND CHARGE OF AND SHALL BE <br />RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR <br />PROCEDURES, FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK, <br />FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTOR OR ANY OTHER <br />PERSONS PERFORMING ANY WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. <br />7.PROVIDE CONTINUOUS INSPECTION IN ACCORDANCE WITH THE BUILDING CODE FOR <br />REINFORCED CONCRETE. PLACEMENT OF REINFORCING STEEL, STRUCTURAL STEEL, <br />WELDING, STRUCTURAL MASONRY, FIELD WELDING AND HIGH STRENGTH BOLTS. <br />8.CONTRACTOR TO SCHEDULE CONSTRUCTION ACTIVITIES TO HAVE THE LEAST IMPACT ON <br />EXISTING FUNCTIONS, CONTAIN ACTIVITIES SUCH AS THE USE OF JACKHAMMERS SHALL BE <br />SCHEDULED AT SPECIAL TIMES. CONTACT THE DESIGNATED NOISE DISTURBANCE <br />COORDINATOR FOR SCHEDULING OF ALL ACTIVITIES. <br />9.CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF EXISTING HVAC FILT ERS WITHIN <br />AREAOF WORK. <br />10.CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF AND WHERE REQUIRED BY THE <br />OSHPD FIRE MARSHAL, THE OPERATIONAL MAINTENANCE OF FIRE LIFE SAFETY DEVICES WITHIN <br />THE AREA OF WORK. <br />EXISTING CONDITIONS <br />1.U.N.O. SURFACES ADJOINING AREAS OF DEMOLIT IONS AND/OR NEW WORK SHALL BE <br />PATCHED AND REFINISHED AS REQUIRED TO MATCH ADJACENT SURFACES IN ALL ASPECTS, <br />INCLUDING FINISH MATERIAL, COLOR, TEXTURE, FIRE RATING AND SUBSTRATE. <br />2.PATCH SURFACES WHERE AFFECTED BY INSTALLATION OF NEW MECHANICAL, ELECTRICAL <br />AND STRUCTURAL IT EMS. MATCH EXISTING ADJACENT SURFACES AND FINISHES EXCEPT <br />WHERE OTHERWISE NOT ED OR INDICATED. <br />3.WHERE NEW WALL OR CEILING CONTINUES EXISTING WALL OR CEILING, ALIGN VISIBLE NEW <br />SURFACE WITH EXISTING. ADJUST AND STAGGER STUDS IF REQUIRED TO ALIGN STUDS IF <br />REQUIRED TO ALIGN FACE OF WALLS. <br />4.THE CONTRACTOR SHALL SUPERVISE ALL CUTT ING, PATCHING, REPAIRING, RESTORING, AND <br />ANY NECESSARY ACTION TO COMPLETE THE WORK. THE CONTRACTOR SHALL REST ORE <br />AND MATCH ANY DAMAGED WORK TO THE ORIGINAL CONDITION TO T HE ARCHITECT'S <br />SATISFACTION. <br />5.EXISTING CONDITIONS AND OPERATIONS SHALL BE DOCUMENTED PRIOR TO INIT IATION OF <br />RENOVAT ION AND/ OR NEW CONSTRUCTION PROJECTS. THIS SHALL INCLUDE <br />DOCUMENTATION OF EXISTING MECHANICAL/ELECTRICAL/ STRUCTURAL CAPACITIES AND <br />QUANTITIES. DOCUMENTATION OF EXISTING CONDITIONS SHOULD INCLUDE THE FOLLOWING: <br />A. FIRE SUPPRESSION, DETECTION, AND ALARM SYSTEMS <br />B. VARIOUS COMMUNICATIONS SYSTEMS (INCLUDING TELEPHONE, NURSE CALL, <br /> OVERHEAD PAGING, TELEMETRY, DICTATION, ELECTRONIC IMAGING) <br /> VARIOUS PLUMBING SYSTEMS (INCLUDING DOMESTIC WATER, TREATED WATER, <br /> WASTEWATER, PNEUMATIC TUBE, PNEUMATIC CONTROLS, MEDICAL GASES/ <br /> VACUUM) <br />C. EXISTING AIRFLOW OF AFFECTED AREAS <br />D. MAIN ELECTRICAL SERVICE AND ELECTRICAL SERVICE AFFECTED BY <br /> CONSTRUCTION (INCLUDING RATING AND ACTUAL LOAD/PEAK AND FEEDER SIZES <br /> AS APPLICABLE AND POWER FACTOR) <br />E. EMERGENCY POWER SYSTEM (INCLUDING RATING AND ACTUAL LOAD/PEAK AND <br /> FEEDER SIZES, AS APPLICALE, FOR LIFE SAFETY, EMERGENCY/CRITICAL, AND <br /> EQUIPMENT BRANCHES) <br />DEMOLITION <br />1.CONTRACTOR SHALL VERIFY THE LOCAT ION OF ALL EXISTING UTILITIES PRIOR TO <br />COMMENCING CONSTRUCTION AND SHALL TAKE STEPS TO PROTECT SUBJECT UTILITIES, <br />PERSONNEL AND PROPERTY AGAINST DAMAGE OR INJURY. <br />2.CONTRACTOR SHALL VERIFY LOCATION OF ALL REINFORCING STEEL AND CONDUIT IN <br />EXISTING CONCRETE SLABS AND AVOID SAME. CONTRACTOR SHALL PREPARE SHOP <br />DRAWINGS FOR REVIEW BY THE ARCHITECT AND/OR SEOR PRIOR TO PROCEEDING WITH <br />CORE OR SAW-CUTTING. <br />3.ALL REMOVED F IXTURES, EQUIPMENT , ACCESSORIES AND DOORS SHALL BE SALVAGED TO <br />THE OWNER. ITEMS NOT WANTED BY OWNER SHALL BE DISCARDED OFF -SITE BY THE <br />CONTRACTOR. <br />4.TEMPORARY STORAGE OF EQUIPMENT SHALL BE PROT ECTED FROM VANDALISM. STORE IN <br />A LOCATION THAT IS ACCEPTABLE TO THE OWNER. <br />5.PROTECT ALL ADJACENT AREAS FROM DUST, FUMES, SMOKE, WATER, WEATHER AND <br />NOISE. <br />6.PROTECT ALL ADJACENT BUILDING COMPONENTS -FINISHES AND EQUIPMENT. SHOULD <br />DAMAGE OCCUR, REPAINT, PATCH OR REPLACE AT NO ADDITIONAL COST T O THE OWNER. <br />7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTINUOUS CLEAN UP OF THE SITE OF <br />ALL DEBRIS WHETHER CREATED BY THE CONTRACTOR'S WORK OR THE FAILURE OF THE <br />CONTRACTOR'S SUB-CONTRACTORS TO CLEAN UP AFTER THEIR WORK. <br />8.ALL ABANDONED PLUMBING LINES, ELECTRICAL CONDUIT OR BOXES, A/C DUCTS OR <br />DIFFUSERS AND TELEPHONE CABLES WILL BE REMOVED BACK TO CLOSEST FEEDER POINT. <br />9.DO NOT CUT, DRILL, NOTCH, CORE, ALTER, OR DAMAGE STRUCTURAL ELEMENTS OR F RAMING <br />UNLESS SPECIFICALLY DETAILED ON APPROVED PLANS OR ACCEPTED BY THE SEOR/AOR. <br />FIRE AND LIFE SAFETY MEASURES <br />1.REQUIRED MEANS OF EGRESS SHALL BE MAINTAINED DURING CONST RUCTION AND DEMOLIT ION AT <br />ALL TIMES. <br />2.TEMPORARY EXITING SHALL BE APPROVED BY THE LOCAL FIRE AUTHORITY. (CFC -2022, SECTION <br />3312.2) <br />3.PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE LOCAL F IRE AUTHORITY. <br />4.CONTRACTOR SHALL PROVIDE PROPER FIRE STOPPING AT EXISTING OR NEW FLOOR AND WALL <br />PENETRATIONS FOR MECHANICAL, PLUMBING, ELECTRICAL AND F IRE SPRINKLER LINES AS <br />REQUIRED PER THE APPROPRIATE UL DESIGN LISTING NUMBER. <br />5.FIRE PROT ECTION SYSTEM SHALL BE MAINTAINED OPERATIONAL AT ALL TIMES DURING <br />ALTERATION. <br />6.SMOKE DET ECTORS SHALL BE COVERED OR REMOVE DURING ALTERAT ION WHEN REQUIRED BY THE <br />LOCAL FIRE AUTHORITY, COVERINGS PLACED ON OR OVER FIRE PROTECTION DEVICES TO PROTECT <br />THEM FROM DAMAGE DURING CONSTRUCTION PROCESSES SHALL BE IMMEDIATELY REMOVED UPON <br />THE COMPLETION OF THE CONSTRUCTION PROCESSES IN THE ROOM OR AREA IN WHICH T HE DEVICES <br />ARE INSTALLED. (CFC -2022, SECTION 3308.9) <br />7.FIRE RESISTIVE RATED CONST RUCTION SHALL BE MAINTAINED AT ALL TIMES DURING <br />CONSTRUCTION. (CFC -2022, SECTION 703.1) <br />8.CUTT ING AND WELDING OPERATION SHALL BE IN ACCORDANCE WITH CHAPTER 35 OF THE FIRE <br />CODE. (CFC -2022, SECTION 3305.6) <br />NONCONFORMING CONDITIONS <br />IN T HE EVENT THAT AN EXISTING NONCONFORMING CONDITION IS DISCOVERED DURING THE COURSE OF <br />CONSTRUCTION, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND ARCHITECT. THE ARCHITECT <br />AND THE IOR WILL WORK WITH THE LOCAL FIRE AUTHORITY TO DETERMINE THE NECESSARY COURSE OF <br />ACTION WITH REGARD TO THE EXISTING ELEMENT. <br />TEMPORARY CONSTRUCTION <br />1.CONTRACTOR SHALL ARRANGE FOR, IN ADVANCE WITH THE OWNER, CONSTRUCTION <br />STORAGE AND ST AGING AREAS NECESSARY TO COMPLETE THE WORK. ALL STORAGE AND <br />STAGING AREAS SHALL BE RETURNED TO THE OWNER IN LIKE ORIGINAL CONDITION. <br />2.THE CONTRACTOR SHALL PROVIDE ADEQUATE MEANS TO PROTECT FINISHED PARTS OF <br />THE MATERIALS AND EQUIPMENT AGAINST DAMAGE FROM ANY CAUSE DURING THE <br />PROGRESS OF THE WORK AND UNTIL ACCEPTANCE BY THE OWNER. <br />3.CONTRACTOR SHALL MAKE EVERY EFFORT TO MAINTAIN A CLEAN WORK PLACE. DUST <br />PALLIATION AND PREVENTION OF DUST CONTAMINATION OF NON-WORK SPACES WILL BE <br />THE RESPONSIBILITY OF T HE CONTRACTOR ON AN ON GOING, DAILY BASIS. THE <br />CONTRACTOR SHALL DEVELOP A SCHEDULE OF CONST RUCTION WHICH INCLUDES THE <br />NECESSARY ACTIONS TO MAINTAIN THE OPERATION OF THE TENANTS DURING THE <br />CONSTRUCTION PROCESS. <br />4.CONTRACTOR SHALL MAKE NECESSARY CONNECTIONS TO EXISTING UTILIT IES F OR <br />TEMPORARY POWER AND WATER SUPPLIES, AND SHALL COORDINATE SUCH USE WITH THE <br />OWNER PRIOR TO CONNECTION. <br />15" MIN. <br />15" MIN. <br />8" <br />ALIGN <br />ALIGN <br />COVER PLATE <br />FLOOR DATUM <br />ALIGN <br />ALIGN <br />FLOOR DATUM <br />COVER PLATE <br />FACILITY NAME:HARBOR MACARTHUR MEDICAL OFFICE BUILDING <br />FACILITY ADDRESS:3401 S. HARBOR BLVD. <br />SANTA ANA, CA 92704 <br />PROJECT NAME:SOCC 2022 R HBM 1ST FLR KPOJ REMODEL <br />CONSTRUCTION INF ORMATION <br />CONSTRUCTION TYPE:II-B <br />MAIN OCCUPANCY:B (MEDICAL OFFICE BUILDING) <br />YEAR OF CONSTRUCTION:PHASE I: 2000, PHASE II, PHASE III: 2002 <br />FIRE EXTINGUISHING SYSTEM:FULLY SPRINKLERED <br />NUMBER OF STORIES:3 <br />AREA LIMITATIONS:UNLIMITED <br />REMODEL INFORMATION <br />REMODEL FLOOR:1ST FLR <br />REMODEL USE/OCCUPANCY:B (OFFICES) <br />TOTAL REMODEL AREA:2195 SF <br />PROJECT SCOPE: <br />THE PROJECT INCLUDES THE REMODEL OF AN EXISTING OFFICE SPACE INTO A NEW A CLINIC SPACE <br />FOR THE KPOJ DEPARTMENT. THE REMODEL WILL INCLUDE AN OFFICE AREA FOR 4 PROVIDERS, <br />CLINICAL AREA WITH 4 EXAM ROOMS, 1 MED PREP, 1 PATIENT TOILET, 1 AUDIOLOGY TESTING ROOM, 1 <br />ULT RASOUND ROOM, AND 4 STAFF STATIONS. <br />GENERAL PROVISIONS <br />1.ALL WORK SHALL CONFORM TO THE CURRENT EDITIONS OF NATIONAL, STATE AND <br />LOCAL CODES, AND OTHER REGULAT ORY AGENCIES WHICH HAVE AUTHORITY OVER ANY <br />PORTION OF THE WORK. ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING <br />GENERAL CONSTRUCTION, MECHANICAL, ELECTRICAL, PLUMBING, OR RELATED WORK SHALL <br />COMPLY WITH APPLICABLE SECTIONS OF THE CODES THAT HAVE JURISDICTION, INCLUDING <br />BUT NOT LIMITED TO: <br />2022 CALIFORNIA ADMINISTRATIVE CODE (CAC) <br />CALIFORNIA CODE OF REGULATIONS I TITLE 24, PART 1 <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 2 <br />(BASED ON THE 2018 INTERNATIONAL BUILDING CODE) <br />2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 3 <br />(BASED ON THE 2017 NAT IONAL ELECTRICAL CODE) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 4 <br />(BASED ON THE 2018 UNIF ORM MECHANICAL CODE) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 5 <br />(BASED ON THE 2018 UNIF ORM PLUMBING CODE) <br />2022 CALIFORNIA FIRE CODE (CFC) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 9 <br />(BASED O THE 2018 INTERNATIONAL FIRE CODE) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN CODE) <br />CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 11 <br />TITLE 19, CALIFORNIA CODE OF REGULATIONS (CCR) <br />DIVISION 1, STATE F IRE MARSHAL REGULATIONS <br />2022 CALIFORNIA BUILDING CODE CHAPTER 35 REFERENCE STANDARDS <br />NFPA 13-22: STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS <br />NFPA 72-22: NAT IONAL F IRE ALARM AND SIGNAL CODE WIT H CALIFORNIA AMENDMENTS <br />2.ALL WORK AND MATERIALS SHALL BE IN F ULL ACCORDANCE WITH THE REQUIREMENTS OF <br />THESE CODES AND ALL APPLICABLE LOCAL ORDINANCES. WHERE CONTRACT DOCUMENTS <br />EXCEED SUCH REQUIREMENTS, WITHOUT VIOLATING SUCH CODES, REGULATIONS AND <br />ORDINANCES, CONTRACT DOCUMENTS TAKE PRECEDENCE. WHERE CODES CONFLICT, THE <br />MORE STRINGENT SHALL APPLY. <br />INFECTION CONTROL RISK ASSESSMENT (ICRA) <br />THE INFECTION CONTROL RISK ASSESSMENT IS A MULT IDISCIPLINARY, DOCUMENTED <br />ASSESSMENT PROCESS INTENDED TO PROACTIVELY IDENTIFY AND MITIGATE RISKS FROM <br />INFECTION THAT COULD OCCUR DURING CONSTRUCTION ACTIVITIES. THIS PROCESS IDENTIFIES <br />AND TAKES INTO ACCOUNT THE PATIENT POPULATION AT RISK, THE NATURE AND SCOPE OF THE <br />PROJECT, AND THE FUNCTIONAL PROGRAM OF THE HEALTH CARE FACILITY. THE ICRA <br />DETERMINES THE POTENTIAL RISK OF TRANSMISSION OF VARIOUS AIR-AND WATERBORNE <br />BIOLOGICAL CONTAMINANTS IN THE FACILITY. <br />ICRA TIMING <br />AN ICRA SHALL BE CONDUCTED BEFORE CONSTRUCTION BEGINS, AND CONTINUE THROUGH <br />PROJECT CONSTRUCTION AND COMMIS SIONING. <br />ICRA TEAM <br />AT MINIMUM, AN ICRA SHALL BE CONDUCTED BY A TEAM WITH EXPERTISE IN INFECTION <br />PREVENTION AND CONTROL, DIRECT PATIENT CARE (CLINICAL USE OF RELEVANT AREAS), FACIL- <br />ITY DESIGN, CONSTRUCTION, AND HVAC AND PLUMBING SYSTEMS WHEN THESE SYSTEMS ARE <br />INVOLVED. THE SCOPE AND NATURE OF THE PROJECT SHALL DICTATE OTHERS TO BE INVOLVED. <br />ICRA CONSIDERATIONS <br />THE ICRA SHALL ADDRESS, BUT NOT BE LIMITED TO COVER ING, THE FOLLOWING: <br />• NUMBER, LOCATION, AND TYPE OF AIRBORNE INFECTION ISOLATION AND PROT ECTIVE <br />ENVIRONMENT ROOMS. <br />• NUMBER, LOCAT ION, AND TYPE OF PLUMBED HAND-WASHING STATIONS, HAND <br />SANITATION DISPENSERS, AND EMERGENCY FIRST -AID EQUIPMENT (EYEWASH STATIONS <br />AND DELUGE SHOWERS). <br />(1) T HE NUMBER AND LOCATION OF HAND-WASHING STATIONS AND HAND <br />SANITATION <br />DISPENSERS SHALL BE DETERMINED BY THE FUNCTIONAL PROGRAM AND THE <br />ICRA. <br />(2) HAND-WASHING STATIONS SHALL BE CONVENIENT AND ACCESSIBLE FOR <br />HEALTH CARE PERSONNEL AND OTHER USERS. <br />• SPECIAL HVAC NEEDS TO MEET THE FUNC TIONAL PROGRAM AND ACCOMMODATE T HE <br />SERVICES (E.G., SURGICAL SERVICES, AIRBORNE INFECTION ISOLATION AND PRO- <br />TECTIVE ENVIRONMENT ROOMS, LABORATORIES, PHARMACIES, LOCAL EXHAUST <br />SYSTEMS FOR HAZARDOUS AGENTS, AND OTHER SPECIAL AREAS) INCLUDED IN OR <br />AFF ECTED BY THE PROJECT <br />• WATER SYSTEMS TO LIMIT LEGIONELLA SP. AND WATERBORNE OPPORTUNISTIC <br />PATHOGENS <br />WHEN CONDUCTING THE ICRA AND DEVELOPING THE INFEC TION CONTROL RISK MITIGATION <br />REQUIREMENTS FOR BUILDING AND SITE AREAS ANTICIPATED T O BE AFFECTED BY CONSTRUC- <br />TION, THE FOLLOWING SHALL BE ADDRESSED: <br />• THE IMPACT OF DISRUPTING ESSENTIAL SERVICES TO PATIENTS AND EMPLOYEES <br />• DET ERMINATION OF THE SPECIFIC HAZARDS AND PROTECTION LEVELS FOR EACH <br />DESIGNATED AREA <br />• LOCATION OF PATIENTS ACCORDING TO THEIR SUSCEPTIBILITY TO INFECTION AND THE <br />DEFINITION OF RISKS TO EACH <br />• IMPACT OF MOVEMENT OF DEBRIS, TRAFFIC FLOW, SPILL CLEANUP, AND TESTING AND <br />CERTIFICATION OF INSTALLED SYSTEMS <br />• ASSESSMENT OF EXTERNAL AS WELL AS INTERNAL CONSTRUCTION ACTIVITIES <br />• LOCATION OF KNOWN HAZARDS <br />ICRA DOCUMENTATION <br />THIS WRITTEN RECORD SHALL REMAIN AN ACTIVE PART OF THE PROJECT DOCUMENT S FOR THE <br />DURATION OF THE CONSTRUCTION PROJECT AND THROUGH COMMISSIONING. <br />ICRMRS <br />THESE WRITTEN PLANS SHALL DESCRIBE THE SPECIFIC METHODS BY WHICH TRANSMISSION OF <br />AIR-AND WATERBORNE BIOLOGICAL CONTAMINANTS WILL BE AVOIDED DURING CONST RUCTION <br />AS WELL AS DURING COMMISSIONING, WHEN HVAC AND PLUMBING SYSTEMS AND EQUIPMENT <br />(E.G., ICE MACHINES, STEAM STERILIZATION SYSTEMS) ARE STARTED/RESTARTED. <br />MONITORING PL AN AND PROCEDURES <br />(1) THE OWNER SHALL PROVIDE MONITORING PLANS FOR EFFECTIVE APPLICATION OF ICRMRS <br />DURING T HE COURSE OF THE PROJECT. <br />(2) PROVISIONS FOR MONITORING SHALL INCLUDE WRITTEN PROCEDURES FOR EMERGENCY <br />SUSPENSION OF WORK AND PROTECTIVE MEASURES INDICATING THE RESPONSIBILITIES AND <br />LIMITAT IONS OF EACH PARTY (OWNER, DESIGNER, CONTRACTOR, AND MONITOR). <br />• RESPONSIBILITIES OF PERSONS AND GROUPS FOR PROCEDURES AND ACTIVITIES TO BE <br />PERFORMED TO MITIGATE RISK SHOULD BE INCLUDED IN INFECTION CONTROL RISK <br />MITIGATION PLANS TO ENSURE THE PROPER ACTIONS ARE TAKEN AT THE PROPER TIME. <br />• MONITORING EF FORTS WILL BE DETERMINED BY THE OWNER AND MAY BE CONDUCTED <br />BY THE OWNER’S INFECTION PREVENTIONIST(S), EPIDEMIOLOGIST, CONSTRUCTION <br />COORDINATORS, AND/OR SAFETY STAFF OR BY INDEPENDENT OUTSIDE CONSULTANTS. <br />COMMUNICATION <br />(1) UPDATES ON ICRA COMPLIANCE SHALL BE PROVIDED BY T HE ICRA TEAM. <br />(2) CHANGES TO THE ORIGINAL DESIGN PLANS SHALL BE DOCUMENTED, UPDATED, AND <br />CONTINUOUSLY SHARED BETWEEN THE ICRA TEAM AND THE DESIGNERS/ <br />ARCHITECTS/PLANNERS, OWNER, AND CONTRACTOR. <br />INFECTION CONTROL RISK MITIGATION RECOMMENDATIONS <br />INFECTION CONT ROL RISK MITIGATION RECOMMENDAT IONS (ICRMRS) SHALL BE PREPARED BY <br />THE ICRA TEAM AND SHALL, AT MINIMUM, ADDRESS THE F OLLOWING: <br />1. PATIENT PLACEMENT AND RELOCATION <br />• STANDARDS FOR BARRIERS AND OTHER PROTECTIVE MEASURES REQUIRED TO <br />PROTECT ADJACENT AREAS AND SUSCEPTIBLE PATIENTS FROM AIRBORNE <br />CONTAMINANTS <br />• TEMPORARY PROVISIONS OR PHASING FOR CONSTRUCTION OR MODIFICATION OF HVAC <br />AND WATER SUPPLY SYSTEMS <br />• PROTECTION FROM DEMOLITION <br />• MEASURES TO BE TAKEN TO TRAIN HOSPITAL STAFF, VISITORS, AND CONSTRUCTION <br />PERSONNEL <br />• THE IMPACT OF POTENTIAL UTILITY OUTAGES OR EMERGENCIES, INCLUDING <br />PROTECTION OF PATIENTS DURING PLANNED AND UNPLANNED UTILITY OUTAGES. <br />SPECIFIC HAZARDS THAT ARE LIKELY IN THE EVENT OF DIFFERENT TYPES OF ESSENTIAL <br />SERVICE DISRUPTIONS SHOULD BE PROACTIVELY DETERMINED. A PLAN SHOULD BE <br />DEVELOPED TO ENSURE CONTINUED PROVISION OF SERVICE IN THE EVENT OF PLANNED <br />AND UNPLANNED DISRUPTIONS. <br />• THE IMPACT OF MOVEMENT OF DEBRIS, TRAFFIC FLOW, CLEANUP, ELEVATOR USE FOR <br />CONSTRUCTION MATERIALS AND CONSTRUCTION WORKERS, AND CONSTRUCTION <br />WORKER ROUTES <br />2. VENTILATION OF THE CONSTRUCTION ZONE <br />• AIRFLOW INTO THE CONSTRUCTION ZONE FROM OCCUPIED SPACES SHOULD BE <br />MAINTAINED BY MEANS OF A DEDICATED VENTILATION/EXHAUST SYSTEM FOR THE <br />CONSTRUCTION AREA. ENSURE PROPER OPERATION OF THE AIR -HANDLING SYSTEM IN <br />THE AFFECTED AREA AFTER ERECTION OF BARRIERS AND BEFORE THE ROOM OR AREA <br />IS SET TO NEGATIVE PRESSURE <br />• LOCATIONS OF EXHAUST DISCHARGE RELATIVE TO EXISTING FRESH AIR INTAKES AND <br />FILTERS, AS WELL AS THE DISCONNECTION AND SEALING OF EXISTING AIR DUCTS, <br />SHOULD BE REVIEWED AS REQUIRED BY THE ICRA. <br />• IF THE EXISTING BUILDING SYSTEM OR A PORTION THEREOF IS USED TO ACHIEVE THIS <br />REQUIREMENT, THE SYSTEM SHOULD BE THOROUGHLY CLEANED PRIOR TO OCCUPANCY <br />OF THE CONSTRUCTION AREA. <br />• HOSPITAL CONSTRUCTION BARRIERS FOR PROJECTS IN HIGH-RISK AREAS SHOULD BE <br />MAINTAINED AT A PRESSURE DIFFERENTIAL OF AT LEAST 0.03 INCH WATER GAUGE (7.0 <br />PASCALS), WIT H AIRFLOW FROM HOSPITAL CLEAN AREAS TO CONSTRUCTION DIRTY <br />AREAS. CONSTRUCTION BARRIERS IN HIGH-RISK AREAS SHOULD HAVE VISUAL DISPLAY <br />OF AIRFLOW DIRECTION. (HIGH -RISK AREAS INCLUDE CRITICAL CARE UNITS, EMERGENCY <br />ROOMS, LABOR AND DELIVERY FACILITIES, NEWBORN NURSER IES, OUT PATIENT <br />SURGERY FACILITIES, AREAS SERVING PEDIATRIC PATIENTS, PHARMACIES, SURGICAL <br />UNITS, POST-ANESTHETIC CARE UNITS, AREAS SERVING IMMUNOCOMPROMISED <br />PATIENTS, BURN UNITS, CARDIAC CATHETERIZATION LABS, CENTRAL STERILE SUPPLY, <br />AIRBORNE INFECTION ISOLATION ROOMS, PROTECTIVE ENVIRONMENT ROOMS, <br />ONCOLOGY UNITS, OPERAT ING ROOMS, AND CESAREAN DELIVERY ROOMS.) MONITOR <br />BARRIERS AND ENSURE INTEGRITY OF THE CONSTRUCTION BARRIERS; REPAIR GAPS OR <br />BREAKS IN BARRIER JOINTS <br />3. DISASTER PLANS FOR WATER SUPPLY AND VENTILATION EMERGENCIES <br />• THE OWNER SHOULD PROVIDE A WRITTEN PLAN FOR WHAT WILL HAPPEN IN THE EVENT <br />OF A WATER OUTAGE. THIS SHOULD INCLUDE WHERE SUPPLIES ARE, WHO IS <br />RESPONSIBLE FOR WHAT, AND WHO IS TO BE NOTIFIED. <br />• THE OWNER SHOULD PROVIDE A WRITTEN PLAN FOR WHAT WILL HAPPEN IN THE EVENT <br />OF AN AIR SHUTDOWN. THIS SHOULD INCLUDE WHO IS RESPONSIBLE FOR WHAT AND <br />WHO IS TO BE NOTIF IED. <br />• THE OWNER SHOULD PROVIDE A WRITTEN PLAN FOR WHAT WILL HAPPEN IN THE EVENT <br />OF A WATER LEAK. T HIS SHOULD INCLUDE WHO IS TO BE NOTIFIED. <br />4. CONSTRUCTION WORK ZONE PROTECTION <br />• CONSTRUCTION MATERIALS SHOULD BE KEPT CLEAN AND DRY, AS APPROPRIATE. <br />• DUCTWORK SHOULD BE KEPT CAPPED/CLEAN DURING DEMOLITION AND DUST- <br />GENERATING CONSTRUCTION. <br />• DRYWALL INSTALLATION SHOULD NOT PROCEED UNTIL EXTERIOR PROTECTION AGAINST <br />RAIN DAMAGE HAS BEEN INSTALLED. <br />• CONSTRUCT BARRIERS TO PREVENT DUST FROM CONSTRUCTION AREAS FROM <br />ENTERING PATIENT-CARE AREAS; ENSURE THAT BARRIERS ARE IMPERMEABLE TO <br />FUNGAL SPORES AND IN COMPLIANCE WITH LOCAL FIRE CODES <br />• SEAL OFF AND BLOCK RETURN AIR VENTS IF RIGID BARRIERS ARE USED FOR <br />CONTAINMENT <br />• IMPLEMENT DUST-CONTROL MEASURES ON SURFACES AND DIVERT PEDESTRIAN <br />TRAFFIC AWAY FROM WORK ZONES. <br />• CLEAN WORK ZONES AND THEIR ENTRANCES DAILY BY <br />1) WET-WIPING TOOLS AND TOOL CARTS BEFORE THEIR REMOVAL FROM THE WORK <br />ZONE <br />2) PLACING MATS WITH TACKY SURFACES INSIDE THE ENTRANCE <br />3) COVERING DEBRIS AND SECURING THIS COVERING BEFORE REMOVING DEBRIS FROM <br />THE WORK ZONE <br />• IN PATIENT -CARE AREAS, FOR MAJOR REPAIRS THAT INCLUDE REMOVAL OF CEILING <br />TILES AND DISRUPTION OF THE SPACE ABOVE THE FALSE CEILING, USE PLASTIC SHEETS <br />OR PREFABRICATED PLASTIC UNITS TO CONTAIN DUST; USE A NEGATIVE PRESSURE <br />SYSTEM WITHIN THIS ENCLOSURE TO REMOVE DUST; AND EITHER PASS AIR THROUGH <br />AN INDUSTRIAL-GRADE, PORTABLE HEPA FILTER CAPABLE OF F ILTRATION RATES OF <br />300 -800 FT3/MIN., OR EXHAUST AIR DIRECTLY TO T HE OUTSIDE <br />• UPON COMPLETION OF THE PROJECT, CLEAN THE WORK ZONE ACCORDING TO FACILITY <br />PROCEDURES, AND INSTALL BARRIER CURTAINS TO CONTAIN DUST AND DEBRIS BEFORE <br />REMOVING RIGID BARRIERS. FLUSH THE WATER SYSTEM TO CLEAR SEDIMENT FROM <br />PIPES TO MINIMIZE WATERBORNE MICROORGANISM PROLIFERATION. RESTORE <br />APPROPRIATE ACH, HUMIDITY, AND PRESSURE DIFFERENTIAL; CLEAN OR REPLACE AIR <br />FILTERS; DISPOSE OF SPENT FILTERS <br />5. PROVIDE CONSTRUCTION CREWS WITH <br />• DESIGNATED ENTRANCES, CORRIDORS, AND ELEVATORS WHEREVER PRACTICAL <br />• ESSENTIAL SERVICES (E.G., TOILET FACILIT IES) AND CONVENIENCE SERVICES (E.G., <br />VENDING MACHINES) <br />• PROTECTIVE CLOTHING (E.G., COVERALLS, FOOTGEAR, AND HEADGEAR) F OR TRAVEL TO <br />PATIENT -CARE AREAS <br />• A SPACE OR ANTEROOM F OR CHANGING CLOTHING AND STORING EQUIPMENT <br />CONTRACTOR SHALL PREPARE SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS AND <br />SUBMIT TO THE ARCHITECT OR ENGINEER FOR REVIEW PRIOR T O SUBMITTAL TO THE AGENCY <br />HAVING JURISDICTION (AHJ) FOR APPROVAL. <br />INSTALLATION OF DEFERRED APPROVAL SHALL NOT BE STARTED UNTIL DOCUMENTS HAVE BEEN <br />REVIEWED BY THE ARCHIT ECT OR ENGINEER AND APPROVED BY AHJ. <br />DEF ERRED IT EMS ARE TO BE COMPLETELY INSTALLED PRIOR TO OCCUPANCY OF BUILDING(S) <br />AND/OR AREAS AFFECTED BY THE DEFERRED WORK. <br />DEF ERRED APPROVALS: <br />1. FIRE ALARM DESIGN -REWORK EXISTING SYSTEM TO CONFORM TO NEW SPACE <br />CONFIGURATION. ADD DEVICES AS NECESSARY FOR NEW ROOMS. MATCH DEVICES TO <br />MANUFACTURER OF CURRENT SYSTEM. <br />2. FIRE SPRINKLER DESIGN -REWORK EXISTING SYSTEM TO CONFORM TO NEW SPACE <br />CONFIGURATION. RELOCATE HEADS TO COVER THE AREAS AS NEEDED. BRANCH <br />MODIFICATIONS ONLY, ALL MAIN LINES ARE EXISTING TO REMAIN. MATCH TYPE, STYLE, <br />AND FINISH OF EXISTING SPRINKLER HEADS. <br />3. NURSE CALL DESIGN <br />R <br />No.No.No.No. <br />FFFF <br />LLLLIIIICCCCEEEENNNNSSSSEEEE <br />SSSSTTTTAAAATTTTEEEE <br />DDDD <br />OOOO <br />AAAA RRRRCCCCHHHHIIIITTTTEEEECCCCTTTT <br />CCCC AAAALLLL IIIIFFFFOOOORRRRNNNNIIIIAAAA <br />SSSSTTTTEEEEPPPPHHHHEEEE WWWWHHHHIIIITTTTEEEE <br />R ENEWAL R ENEWAL R ENEWAL R ENEWAL <br />D AT EDATEDATEDATE <br />CCCC----34829348293482934829 <br />NNNN <br />08/31 /2708/31 /2708/31 /2708/31 /27 <br />SHEET T ITLE <br />PROJECT <br />FACILITY <br />FAC NO:BLDG NO:FLOOR LEV:SECTION: <br />KP PROJ. NO. <br />PERMIT NO. <br />555 W. Fifth Street Suite 2950 | Los Angeles, CA 90013 USA <br />ARCHITECT <br />CONSULTANT <br />ARCHITECT SEAL CONSULTANT SEAL <br />KAISER FOUNDATION HOSPITALS <br />NATIONAL FACILITIES SERVICES <br />180 0 HARRISON STREET OAKLAND, <br />CALIFORNIA 94612 <br />NO.ISSUED DATE <br />0 <br />5' <br />50' <br />GRAPHIC SCALES: <br />1/16" = 1'-0" <br />0 <br />25' <br />1/8" = 1'-0" <br />5' <br />0 <br />12' <br />1/4" = 1'-0" <br />1' <br />0 <br />6' <br />1/2" = 1'-0" <br />1' <br />0 <br />2' <br />1-1/2" = 1'-0" <br />0 <br />1' <br />3" = 1'-0" <br />IF <br /> THIS SHEET IS NOT <br />30"x42", IT IS A REDUCED <br />PRINT - <br />SCALE <br />ACCORDINGLY <br />AGENCY APPLICATION NUMBER <br />AGENCY APPROVAL STAMP <br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS <br />NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. <br />HZ PROJ. NO. <br />HISTORY LOG <br />www.huitt-zollars.com <br />Phone 310.820.4600 | Fax 310.207.4215 <br />C:\Users\lrobinson\OneDrive - Huitt-Zollars, Inc\Documents\R314412.35 KP HBM KPOJ_A24_lrobinsonL2MDX.rvt <br />1/6/2026 2:42:31 PM <br />SOCC 2022 R HBM 1st Fl KPOJ <br />REMODEL <br />G0-00 <br />TITLE SHEET, GENERAL NOTES, <br />PROJECT DATA, SITE PLAN <br />CA394-1 -1 - <br />CAP027721R314412.35 <br />HARBOR/MacARTHUR MEDICAL OFF <br />3401 S. HARBOR BLVD. <br />SANTA ANA, CALIFORNIA 92704 <br />101125520, 20187249, 40140902 <br />3401 S. HARBOR BLVD. <br />SANTA ANA, CALIFORNIA 92704 <br />KP NO.CAP027721 <br />SOCC 2022 R HBM 1st Fl KPOJ <br />REMODEL <br />N/ASYMBOLS LEGEND 12 <br />NTSVICINITY MAP 14 <br />N/ADRAWING SET ORGANIZATION 21 N/APROJECT TEAM 11 01N/ASHEET INDEX <br />N/AGENERAL NOTES 22 <br />N/APROJECT SUMMARY 09 <br />N/AAPPLICABLE CODES 08 <br />N/AINFECTION CONTROL NOTES 16 <br />GENERAL <br />G0-00 TITLE SHEET, GENERAL NOTES, PROJECT DATA, SITE PLAN <br />G0-01 SPECIFICATIONS <br />G0-02 SPECIFICATIONS <br />G0-03 SPECIFICATIONS <br />G0-04 SPECIFICATIONS <br />G0-05 SPECIFICATIONS <br />G1-00 PLAN - SITE ACCESSIBLITY <br />G1-10 PLAN - LIFE SAFETY - 1ST FLR <br />G1-11 PLAN - BUILDING ACCESSIBILTY - 1ST FLR <br />STRUCTURAL <br />S0-01 GENERAL NOTES <br />S1-11 PLAN - REMODEL OVERALL - 1ST FLR <br />S1-13 PLAN - REMODEL ENLARGED - 1ST FLR - CLINICAL AREA <br />S5-01 DETAILS <br />ARCHITECTURAL <br />A0-11 PLAN - DEMO OVERALL - 1ST FLR <br />A0-12 PLAN - DEMO OVERALL RCP - 1ST FLR <br />A0-13 PLAN - DEMO ENLARGED - 1ST FLR - CLINICAL AREA <br />A0-14 PLAN - DEMO ENLARGED - 1ST FLR - PROVIDE ENCLAVE <br />A0-15 PLAN - DEMO ENLARGED RCP - 1ST FLR - CLINICAL AREA <br />A0-16 PLAN - DEMO ENLARGED RCP - 1ST FLR - PROVIDER ENCLAVE <br />A1-11 PLAN - REMODEL OVERALL - 1ST FLR <br />A1-12 PLAN - REMODEL OVERALL RCP - 1ST FLR <br />A1-13 PLAN - REMODEL ENLARGED - 1ST FLR - CLINICAL AREA <br />A1-14 PLAN - REMODEL ENLARGED - 1ST FLR - PROVIDER ENCLAVE <br />A1-15 PLAN - REMODEL ENLARGED RCP - 1ST FLR - CLINICAL AREA <br />A1-16 PLAN - REMODEL ENLARGED RCP - 1ST FLR - PROVIDER ENCLAVE <br />A1-17 PLAN - DIMENSIONS & PARTITION TYPE - 1ST FLR - CLINICAL AREA <br />A1-18 PLAN - DIMENSIONS & PARTITION TYPE - 1ST FLR - PROVIDER ENCLAVE <br />A1-41 PLAN - REMODEL - ROOF <br />A2-01 ELEVATIONS - INTERIOR - CLINICAL AREA <br />A2-02 ELEVATIONS - INTERIOR - CLINICAL AREA <br />A2-03 ELEVATIONS - INTERIOR - CLINICAL AREA <br />A2-04 ELEVATIONS - INTERIOR - CLINICAL AREA <br />A2-05 ELEVATIONS - INTERIOR - PROVIDER ENCLAVE <br />A2-06 ELEVATIONS - INTERIOR - PROVIDER ENCLAVE <br />A4-01 ACCESSIBLE TOILET ROOM - PLAN & ELEVATIONS <br />A5-01 DETAILS - PARTITION TYPES <br />A5-02 DETAILS - TYPICAL FRAMING <br />A5-03 DETAILS - TYPICAL CEILING - ACT <br />A5-04 DETAILS - TYPICAL ROOF & MISC. <br />A5-05 DETAILS - CASEWORK <br />A5-06 DETAILS - (E) REGULATORY SIGNAGE <br />A6-01 SCHEDULE - DOOR & WINDOW <br />INTERIORS <br />I1-11 PLAN - FINISH - CLINICAL AREA <br />I1-12 PLAN - FINISH - PROVIDER ENCLAVE <br />EQUIPMENT & FURNITURE <br />Q1-11 PLAN - EQUIPMENT & FURNITURE - 1ST FLR - CLINICAL AREA <br />Q1-12 PLAN - EQUIPMENT & FURNITURE - 1ST FLR - PROVIDER ENCLAVE <br />Q6-01 PLAN - EQUIPMENT & FURNITURE SCHEDULE <br />PLUMBING <br />P0-01 GENERAL NOTES, LEGEND & SYMBOLS <br />P0-02 SPECIFICATION - PLUMBING <br />P0-11 PLAN - DEMO OVERALL - 1ST FLR <br />P0-12 PLAN - DEMO 1ST FLR - CLINICAL AREA <br />P0-13 PLAN - DEMO 1ST FLR - PROVIDER ENCLAVE <br />P1-11 PLAN - REMODEL OVERALL - 1ST FLR <br />P1-12 PLAN - REMODEL 1ST FLR - CLINICAL AREA <br />P5-01 DETAILS - PLUMBING <br />P6-01 SCHEDULES - PLUMBING <br />MECHANICAL <br />M0-01 GENERAL NOTES, LEGEND & SYMBOLS <br />M0-02 SPECIFICATION - MECHANICAL <br />M0-03 T-24 FORMS <br />M0-04 T-24 FORMS <br />M0-11 PLAN - DEMO OVERALL - 1ST FLR <br />M0-12 PLAN - DEMO 1ST FLR - CLINICAL AREA <br />M0-13 PLAN - DEMO 1ST FLR - PROVIDER ENCLAVE <br />M0-31 PLAN - OVERALL ROOF PLAN DEMOLITION <br />M0-32 PLAN - PARTIAL ROOF PLAN DEMOLITION <br />M1-11 PLAN - REMODEL OVERALL - 1ST FLR <br />M1-12 PLAN - REMODEL 1ST FLR - CLINICAL AREA <br />M1-13 PLAN - REMODEL 1ST FLR - PROVIDER ENCLAVE <br />M1-31 PLAN - OVERALL ROOF PLAN NEW WORK <br />M1-32 PLAN - PARTIAL ROOF PLAN NEW WORK <br />M5-01 DETAILS - MECHANICAL <br />M6-01 SCHEDULES - MECHANICAL <br />ELECTRICAL <br />E0-01 ELECTRICAL COVERSHEET <br />E0-02 ELECTRICAL SPECIFICATION <br />E0-03 ELECTRICAL SPECIFICATION <br />E0-04 ELECTRICAL SPECIFICATION <br />E0-05 ELECTRICAL SPECIFICATION <br />E0-06 ELECTRICAL SPECIFICATION <br />E0-10 PLAN- DEMO 1ST FLR - ELECTRICAL - OVERALL <br />E0-11 PLAN- DEMO 1ST FLR - POWER - CLINICAL AREA <br />E0-12 PLAN- DEMO 1ST FLR - POWER - PROVIDER ENCLAVE <br />E0-13 PLAN- DEMO 1ST FLR - LIGHTING - CLINICAL AREA <br />E0-14 PLAN- DEMO 1ST FLR - LIGHTING - PROVIDER ENCLAVE <br />E0-15 PLAN- DEMO 1ST FLR - SIGNAL - CLINICAL AREA <br />E0-16 PLAN- DEMO 1ST FLR - SIGNAL - PROVIDER ENCLAVE <br />E0-17 PLAN- DEMO 1ST FLR - FIRE ALARM - CLINICAL AREA <br />E0-18 PLAN- DEMO 1ST FLR -FIRE ALARM - PROVIDER ENCLAVE <br />E1-10 PLAN - REMODEL 1ST FLR - POWER - ELECTRICAL - OVERALL <br />E1-11 PLAN - REMODEL 1ST FLR - POWER - CLINICAL AREA <br />E1-12 PLAN - REMODEL 1ST FLR - POWER - PROVIDER ENCLAVE <br />E1-13 PLAN - REMODEL 1ST FLR - LIGHTING - CLINICAL AREA <br />E1-14 PLAN - REMODEL 1ST FLR - LIGHTING - PROVIDER ENCLAVE <br />E1-15 PLAN - REMODEL 1ST FLR - SIGNAL - CLINICAL AREA <br />E1-16 PLAN - REMODEL 1ST FLR - SIGNAL - PROVIDER ENCLAVE <br />E1-17 PLAN - REMODEL 1ST FLR - FIRE ALARM - CLINICAL AREA <br />E1-18 PLAN - REMODEL 1ST FLR - FIRE ALARM - PROVIDER ENCLAVE <br />E1-20 PLAN - REMODEL 2ND FLR - ELECTRICAL - OVERALL <br />E1-31 PLAN - PARTIAL ROOF PLAN - ELECTRICAL REMODEL <br />E5-00 PANEL SCHEDULES <br />E5-01 SINGLE LINE DIAGRAM <br />E6-00 ELECTRICAL DETAILS <br />E7-00 TITLE 24 <br />SECURITY <br />T1-11 PLAN - REMODEL 1ST FLR - SECURITY <br />T5-01 DETAILS - SECURITY <br />T6-01 SINGLE LINE DIAGRAM - SECURITY <br />SIGNAGE <br />SG1-11 PLAN - REMODEL ENLARGED 1ST FLR - SIGNAGE <br />SG5-01 DETAILS - SIGNAGE <br />N/ADEFERRED APPROVALS 06 <br />CITY SUBMITTAL / BID SET 11/03/2025 <br />1 CITY BACKCHECK #1 01/06/2026