34 36 <br />K <br />1PA1'1PA1'-(E) <br />1PA2'1PA2'-(E) <br />1PA3'1PA3'-(E) <br />1PA4'1PA4'-(E) <br />1PA5'1PA5'-(E) <br />'T'-(E) <br />150kVA <br />FAPS-1'FAPS-1'-(E)FAPS-2'FAPS-2'-(E) <br />(TYP.) <br />(TYP.) <br />OCC. SENSOR <br />4 <br />2 <br />5 <br />1 <br />6 <br />(TYP.)8 <br />3 <br />(TYP.)11 <br />3 <br />3 <br />5 <br />10 <br />(TYP.) <br />(TYP.)11 <br />(TYP.)6 <br />8 <br />4 <br />(TYP.)7 <br />(TYP.)9 <br />MINERALAC HANGER STRAP <br />TO SUPPORT CONDUIT <br />3/8"∅THREADED ROD <br />LENGTH AS REQUIRED <br />(TYPICAL) <br />COUPLER <br />(TYPICAL)3/8"∅HILTI KB-TZ2 <br />X 2" MIN., EMBED <br />(ESR-4266) (TYPICAL) <br />THREADED ROD <br />LWC/NWC OVER 20GA. MIN., <br />METAL DECK. <br />HILTI X-HS U32 THREADED <br />ROD HANGER ASSEM. <br />ESR 2795 <br />1/4" ROD <br />8'-0" O.C. MAX. <br />CADDY K12, K16 KON-CLIP <br />NOT TO EXCEED 50LBS. <br />HANGER WIRE <br />0.157" DIA. HILTI X-U SHOT PIN X 1.5" MIN. <br />EMBEDMENT @ EA. HANGER (ICC ESR-2269) <br />AND 1 1/2" x 1 1/2" x 12 GA. x 1" CEILING CLIP, <br />TYP. <br />NOTES: <br />1. PROVIDE SUPPORTS @ 10'-0"oc MAX SPACING, AND <br />2'-0" MAX FROM ENDS OF CONDUIT RUN AND <br />LOCATIONS WHERE CONDUIT CHANGES DIRECTION <br />(EACH SIDE OF BEND). <br />LWC/NWC OVER 20GA. <br />MIN., METAL DECK. <br />46 49 <br />N <br />2LA'2LA'-(E) <br />2PA3'2PA3'-(E) <br />TR# '2PA'-(E) <br />2PA2'2PA2'-(E) <br />2PA1'2PA1'-(E) <br />2PA4'2PA4'-(E) <br />2PA5'2PA5'-(E) <br />2-10-16x3/4" SELF <br />TAPPING TEK <br />SCREWS <br />MINIMUM OF 8 #12-14 <br />X1" SELF TAPPING <br />TEK SCREWS. <br />LOCATEON ON EACH <br />SIDE OF ENCLOSURE <br />2-TO 6x16g <br />3-#10-16x3/4" SELF <br />TAPPING TEK SCREWS <br />(TYP. EACH SIDE) <br />W6x16gauge JAMB <br />AT 16" O.C. <br />W6x16gauge @ 16" TYPICAL <br />ELECTRICAL PANELBOARD OR <br />CABINET. MAXIMUM WEIGHT 150 LBS. <br />DO NOT INSTALL IN FIRE RATED WALL <br />FRONT SIDE <br />TE OLIRFFOAC <br />LANRP <br />E 23191 <br />STA <br />ER <br />REGIST <br />ED <br />INA <br />N <br />REENIGE <br />FO OISSE <br />E AICLCERTL <br />Exp. 06/30/26 <br />MIRASOPHOCLISGEORGY <br />IMEG CORP. RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, <br />TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING <br />AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP. AND SHALL <br />NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE <br />EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG CORP. <br />©2022 IMEG CORP. <br />REF. SCALE IN INCHES <br />0 1 2 3 <br />The FUTURE. Built Smarter www.imegcorp.com <br />R <br />SHEET TITLE <br />PROJECT <br />FACILITY <br />FAC NO: BLDG NO: FLOOR LEV: SECTION: <br />KP PROJ. NO. <br />PERMIT NO. <br />555 W. 5th St Suite 2950 | Los Angeles, CA 90013 USA <br />Phone 310.820.4600 | Fax 310.207.4215 <br />www.huitt-zollars.com <br />ARCHITECT <br />CONSULTANT <br />ARCHITECT SEAL CONSULTANT SEAL <br />KAISER FOUNDATION <br />HOSPITALS NATIONAL <br />FACILITIES SERVICES 1800 <br />HARRISON STREET OAKLAND, <br />CALIFORNIA 94612 <br />ISSUE / REVISION LOG <br />NO. ISSUED DATE <br />0 <br />5' <br /> <br />5 <br />0 <br />' <br />GR <br />A <br />P <br />H <br />I <br />C <br /> <br />S <br />C <br />A <br />L <br />E <br />S <br />: <br /> <br />1 <br />/ <br />1 <br />6 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />25 <br />' <br />1/ <br />8 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />5' <br />0 <br />12 <br />' <br />1/ <br />4 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />6' <br />1/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />1' <br />0 <br />2' <br />1- <br />1 <br />/ <br />2 <br />" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />0 <br />1' <br />3" <br /> <br />= <br /> <br />1 <br />' <br />- <br />0 <br />" <br />IF <br /> <br />T <br />H <br />I <br />S <br /> <br />S <br />H <br />E <br />E <br />T <br /> <br />I <br />S <br /> <br />N <br />O <br />T <br /> <br />30 <br />" <br />x <br />4 <br />2 <br />" <br />, <br /> <br />I <br />T <br /> <br />I <br />S <br /> <br />A <br /> <br />R <br />E <br />D <br />U <br />C <br />E <br />D <br /> <br />PR <br />I <br />N <br />T <br /> <br />- <br /> <br />S <br />C <br />A <br />L <br />E <br /> <br />AC <br />C <br />O <br />R <br />D <br />I <br />N <br />G <br />L <br />Y <br />AGENCY APPLICATION NUMBER <br />AGENCY APPROVAL STAMP <br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS <br />NOT TO BE USED WITHOUT OWNER'S WRITTEN PERMISSION. <br />HZ PROJ. NO. <br />222 S. HARBOR BOULEVARD, SUITE 800 I ANAHEIM, CA 92805 <br />PH: 714.490.5555 I FAX: 714.490.5560 <br />IMEG PROJ. NO.: 22008618.00 <br />PROJECT #22008618.00 <br />SOCC 2022 R HBM 1st Fl KPOJ <br />REMODEL <br />E6-00 <br />ELECTRICAL DETAILS <br />CA394-1 <br />CAP0227721R314412.35 <br />HARBOR/MacARTHUR MEDICAL OFF <br />3401 S. HARBOR BLVD. <br />SANTA ANA, CALIFORNIA 92704 <br />1/4" = 1'-0"ENLARGED ELECTRICAL ROOM #1401 08 <br />1/2" = 1'-0"EXAM ROOM - TYPE HEALTHCARE RATED AC CABLE-LIGHTING 06 <br />1/2" = 1'-0"EXAM ROOM - TYPE HEALTHCARE RATED AC CABLE-RECEPTACLES 02 <br />12" = 1'-0"1-1/2, 2, AND 2-1/2 INCH - CONDUIT SUPPORT DETAIL 01 <br />NTS3/4 AND 1 INCH EMT - CONDUIT SUPPORT DETAIL 03 <br />SHEET NOTES # <br />1. RECESSED LIGHT FIXTURE(S) . REFER TO 02/E1-12, FOR QUANTITIES AND <br />LOCATIONS. <br />2. LIGHTING CONTROL RELAY/POWER PACKS. <br />3. LINE VOLTAGE POWER BETWEEN LIGHT FIXTURES, AND FIXTURE WHIP BETWEEN <br />JUNCTION BOX AND LIGHT FIXTURE, SHALL BE HEALTHCARE RATED AC CABLE. <br />4. HOMERUN TO PANEL OR TO ADJACENT ROOM, SHALL BE EMT TYPE CONDUIT. <br />5. LOW VOLTAGE LIGHTING CONTROLS CABLE BETWEEN RELAY/POWER PACKS AND <br />LOW VOLTAGE LIGHTING CONTROL DEVICES, SHALL BE IN FLEX METAL CONDUIT. <br />6. DO NOT INSTALL TYPE MC CABLE HORIZONTALLY IN WALLS. ALL HORIZONTAL <br />INSTALLATION IN WALLS SHALL BE EMT CONDUIT. <br />7. LINE VOLTAGE POWER BETWEEN RECESSED RECEPTACLES IN WALL AND ABOVE <br />CEILING JUNCTION BOX(ES) SHALL BE HEALTHCARE RATED AC CABLE. <br />8. JUNCTION BOX(ES) ABOVE FINISHED CEILING, AS REQUIRED. <br />9. RECESSED RECEPTACLES IN WALL. REFER TO 01/E1-12, FOR QUANTITIES AND <br />LOCATIONS. <br />10. LIGHTING CONTROL WALL STATIONS. REFER TO 02/E1-12, FOR QUANTITIES AND <br />LOCATION. <br />11. LINE VOLTAGE POWER BETWEEN ABOVE CEILING JUNCTION BOX(ES) SHALL BE <br />EMT TYPE CONDUIT.CITY SUBMITTAL 11/03/2025 <br />1/4" = 1'-0"ENLARGED ELECTRICAL ROOM #2320 07 <br />12" = 1'-0"PANELBOARD OR CABINET MOUNTING DETAIL(S)11 <br />1 CITY BACKCHECK #1 01/06/2026 <br />101125520, 20187249, 40140902