<br />SPECIFICATIONS -PLUMBING I Plannilnn and Riiilrlinn AnPn
<br />PART 1 GENERAL
<br />1.01 SCOPE
<br />A. THE WORK UNDER THIS SECTION INCLUDES EVERYTHING NECESSARY FOR AND INCIDENTAL TO
<br />EXECUTING AND COMPLETING THE PLUMBING WORK, EXCEPT AS HEREINAFTER SPECIFICALLY
<br />EXCLUDED.
<br />B. WORK INCLUDED SHALL BE AS INDICATED ON THE DRAWINGS, INCLUDING BUT NOT LIMITED TO
<br />THE FOLLOWING:
<br />1. SANITARY SOIL, WASTE AND VENT SYSTEM.
<br />2. DOMESTIC AND INDUSTRIAL HOT AND COLD WATER SYSTEM.
<br />3. PLUMBING FIXTURES AND EQUIPMENT.
<br />1.02 CODES AND STANDARDS
<br />A. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES AND
<br />REGULATIONS OF THE FIRE MARSHAL; THE SAFETY ORDERS OF THE DIVISION OF INDUSTRIAL
<br />SAFETY; THE CALIFORNIA ELECTRIC CODE; THE CALIFORNIA PLUMBING CODE; THE CALIFORNIA
<br />MECHANICAL CODE; OTHER APPLICABLE CODES, LAWS OR REGULATIONS OF BODIES LAWFULLY
<br />EMPOWERED AND HAVING JURISDICTION OVER THIS PROJECT. NOTHING IN THE PLANS OR
<br />SPECIFICATIONS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES.
<br />1.03 PERMITS
<br />A. CONTRACTOR SHALL OBTAIN ALL PERMITS AND LICENSES THAT ARE REQUIRED FOR THE
<br />PERFORMING OF HIS WORK BY ALL LAWS, ORDINANCES, RULES AND REGULATIONS OR
<br />ORDERS OF ANY OFFICER AND/OR BODY, SHALL GIVE ALL NOTICES NECESSARY IN
<br />CONNECTION THEREWITH, AND PAY ALL FEES RELATING THERETO AND ALL COSTS AND
<br />EXPENSES INCURRED ON ACCOUNT THEREOF. NO WORK SHALL BE COVERED BEFORE
<br />INSPECTION BY THE JURISDICTIONAL INSPECTION AND THE ARCHITECT.
<br />1.04 CUTTING AND PATCHING
<br />A. PERFORM ALL CUTTING AND FITTING REQUIRED FOR WORK OF THIS SECTION IN ROUGH
<br />CONSTRUCTION OF THE BUILDING.
<br />B. ALL PATCHING OF FINISHED CONSTRUCTION OF BUILDING SHALL BE PERFORMED UNDER THE
<br />SECTIONS OF SPECIFICATIONS COVERING THESE MATERIALS.
<br />C. ALL PATCHING OF EXISTING SURFACES SHALL MATCH EXISTING MATERIALS AND FINISHED.
<br />1.05 GENERAL
<br />A. UNLESS OTHERWISE SPECIFIED HEREIN, ALL EQUIPMENT AND FIXTURES SHALL BE INSTALLED
<br />IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS.
<br />B. BEFORE SUBMITTING HIS BID, THE CONTRACTOR FOR THE WORK UNDER THIS SECTION SHALL
<br />CAREFULLY STUDY ALL DRAWINGS, AND SHALL MAKE A CAREFUL EXAMINATION OF THE
<br />PREMISES. HE SHALL DEFINITELY DETERMINE IN ADVANCE, THE METHODS OF INSTALLING AND
<br />CONNECTING THE APPARATUS, THE MEANS TO BE PROVIDED FOR GETTING ANY EQUIPMENT
<br />INTO PLACE, AND SHALL MAKE HIMSELF THOROUGHLY FAMILIAR WITH ALL THE REQUIREMENTS
<br />OF THE CONTRACT. AFTER AWARD OF THE CONTRACT, NO SUBSEQUENT ALLOWANCES WILL BE
<br />MADE WITH THE ABOVE REQUIREMENTS AND ANY OTHER CONDITIONS AFFECTING THE
<br />INSTALLATION AND COMPLETION OF ALL WORK.
<br />C. WORKMANSHIP: ALL LABOR SHALL BE CAREFULLY SKILLED FOR THIS KIND OF WORK,
<br />THOROUGH AND FIRST CLASS IN ALL RESPECTS AND UNDER THE DIRECTOR OF A COMPETENT
<br />FOREMAN.
<br />D. SPECIAL NOTE: ANY WORK CALLED FOR ON PLANS SHALL BE INSTALLED WHETHER OR NOT
<br />MENTIONED IN THESE SPECIFICATIONS.
<br />1.06 DAMAGE BY LEAKS
<br />A. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE GROUNDS, WALKS, ROADS,
<br />BUILDINGS, PIPING SYSTEMS, ELECTRICAL SYSTEMS AND THEIR EQUIPMENT AND CONTENTS,
<br />CAUSED BY LEAKS IN THE PIPING SYSTEM BEING INSTALLED OR HAVING BEEN INSTALLED
<br />HEREIN. HE SHALL REPAIR AT THIS EXPENSE ALL DAMAGE SO CAUSED. ALL REPAIR WORK
<br />SHALL BE DONE AS DIRECTED BY THE ARCHITECT.
<br />1.07 EMERGENCY REPAIRS
<br />A. THE OWNER RESERVES THE RIGHT TO MAKE EMERGENCY REPAIRS AS REQUIRED TO KEEP
<br />EQUIPMENT IN OPERATION WITHOUT VOIDING THE CONTRACTOR'S GUARANTEE BOND NOR
<br />RELIEVING THE CONTRACTOR OF HIS RESPONSIBILITIES.
<br />1.08 EXPLANATION AND PRECEDENCE OF DRAWINGS
<br />A. FOR PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC,
<br />AND, ALTHOUGH SIZE AND LOCATION OF EQUIPMENT ARE DRAWN TO SCALE WHEREVER
<br />POSSIBLE, CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL THE CONTRACT DOCUMENTS
<br />AND SHALL VERIFY THIS INFORMATION AT BUILDING SITE.
<br />B. THE DRAWINGS INDICATE REQUIRED SIZE AND POINTS OF TERMINATION OF PIPES, AND
<br />SUGGEST PROPER ROUTES TO CONFORM TO STRUCTURE, AVOID OBSTRUCTIONS AND
<br />PRESERVE CLEARANCES. HOWEVER, IT IS NOT INTENDED THAT DRAWING INDICATE ALL
<br />NECESSARY OFFSETS, AND IT SHALL BE THE WORK OF THE CONTRACTOR TO MAKE THE
<br />INSTALLATION IN SUCH A MANNER AS TO CONFORM TO STRUCTURE, AVOID OBSTRUCTIONS,
<br />PRESERVE HEADROOM AND KEEP OPENING AND PASSAGEWAYS CLEAR, WITHOUT FURTHER
<br />INSTRUCTIONS OR COST TO THE OWNER.
<br />C. IT IS INTENDED THAT ALL APPARATUS BE LOCATED SYMMETRICAL WITH ARCHITECTURAL
<br />ELEMENTS. REFER TO ARCHITECTURAL DETAILS IN COMPLETING THE CORRELATING WORK.
<br />D. THE CONTRACTOR SHALL FULLY INFORM HIMSELF REGARDING ANY AND ALL PECULIARITIES
<br />AND LIMITATIONS OF THE SPACES AVAILABLE FOR THE INSTALLATION OF ALL WORK AND
<br />MATERIALS FURNISHED AND INSTALLED UNDER THE CONTRACT. HE SHALL EXERCISE DUE
<br />AND PARTICULAR CAUTION TO DETERMINE THAT ALL PARTS OF HIS WORK ARE MADE QUICKLY
<br />AND EASILY ACCESSIBLE.
<br />E. THE CONTRACTOR SHALL STUDY ALL DRAWINGS AND SPECIFICATIONS TO DETERMINE ANY
<br />CONFLICT WITH ORDINANCES AND STATUTES. ANY ERRORS OR OMISSIONS SHALL BE
<br />REPORTED, AND ANY CHANGES SHALL BE SHOWN IN THE AS -BUILT DRAWINGS AND THE
<br />ADDITIONAL WORK PERFORMED AT NO COST TO THE OWNER.
<br />F. SUBMITTAL OF BID SHALL INDICATE THE CONTRACTOR HAS EXAMINED THE SITE AND DRAWINGS
<br />AND HAS INCLUDED ALL REQUIRED ALLOWANCES IN HIS BID. NO ALLOWANCE SHALL BE
<br />MADE FOR ANY ERROR RESULTING FROM CONTRACTOR S FAILURE TO VISIT JOB SITE AND TO
<br />REVIEW DRAWINGS, AND BID SHALL INCLUDE COSTS FOR ALL REQUIRED DRAWINGS AND
<br />CHANGES AS OUTLINED ABOVE, ALL AT NO COST TO OWNER.
<br />PART 2 PRODUCTS
<br />2.01 FITTINGS AND PIPING
<br />A. ALL DOMESTIC WATER PIPING: ABOVE GRADE, "TYPE L" COPPER TUBING, HARD DRAWN WITH
<br />WROUGHT COPPER FITTINGS, AND SILVER SOLDERED JOINTS.
<br />B. WASTE AND VENT PIPING SHALL BE NO -HUB CAST IRON WITH STAINLESS STEEL AND
<br />NEOPRENE TYPE COUPLINGS.
<br />2.02 VALVES AND FITTINGS
<br />A. ANGLE STOPS
<br />1. SEE FIXTURE SCHEDULE ON DRAWINGS.
<br />2.03 PLUMBING FIXTURES
<br />A. GENERAL REQUIREMENTS
<br />1. PROVIDE NEW FIXTURES, APPROVED, FREE FROM FLAWS AND BLEMISHED, WITH FINISHED
<br />SURFACES CLEAR, SMOOTH AND BRIGHT.
<br />2. VISIBLE PARTS OF FIXTURE BRASS AND ACCESSORIES SHALL BE HEAVILY CHROME PLATED.
<br />3. FIXTURES SHALL BE PRODUCT OF ONE MANUFACTURER. FITTING OF SAME TYPE SHALL BE
<br />PRODUCTS OF ONE MANUFACTURER.
<br />4. PROTECT FIXTURES AGAINST USE AND DAMAGE DURING CONSTRUCTION.
<br />B. JOB CONDITIONS
<br />1. CONFIRM LOCATION AND SIZE OF FIXTURES AND OPENING BEFORE ROUGH -IN AND
<br />INSTALLATION.
<br />2. PLUMBING FIXTURE TRIM AND EXPOSED SUPPLIES AND WASTE SHALL BE BRASS WITH
<br />POLISHED CHROME PLATED FINISH. INDIVIDUAL LOOSE KEY STOPS, OR SO SPECIFIED,
<br />SCREW DRIVER STOPS, SHALL BE PROVIDED FOR ALL SUPPLIES, AND UNLESS INTEGRAL
<br />WITH VALVES OR FAUCET, UNLESS, OTHERWISE APPROVED BY ARCHITECT, SHALL BE
<br />MOUNTED UNDER THE FIXTURE. EXPOSED SUPPLIES AND WASTES TO WELL SHALL BE
<br />PROVIDED WITH POLISHED CHROME PLATED CAST BRASS WELL ESCUTCHEONS.
<br />3. SUPPLIES SHALL BE WITH LOOSE KEY STOPS AND FLEXIBLE RISERS.
<br />4.TRAPS ABOVE FLOOR SHALL BE CAST BRASS "P" TRAPS WITH BRONZE NUTS UNLESS
<br />OTHERWISE INDICATED.
<br />C. SEE FIXTURE SCHEDULE ON DRAWINGS.
<br />PART 3 EXECUTION
<br />3.01 PIPE INSTALLATION
<br />A. JOINTS IN COPPER TUBING SHALL BE MADE BY FIRST THOROUGHLY CLEANING THE SURFACE
<br />OF THE PIPE AND FITTINGS, APPLYING FLUX AND SWEATING WITH SOLDER.
<br />B. PIPE SHALL BE CAREFULLY CLEANED BEFORE INSTALLATION. THE ENDS OF THREADED PIPE
<br />SHALL BE REAMED OUT FULL SIZE WITH A LONG TAPER REAMER SO AS TO BE PARTIALLY
<br />BELL -MOUTHED AND PERFECTLY SMOOTH.
<br />C. FLUSH OUT ALL WATER MAINS AND SANITARY DRAINS WITH WATER SO AS TO OBTAIN FREE
<br />FLOW. REMOVE ALL OBSTRUCTIONS AND DEFECTS DISCOVERED. REMOVE AND RELAY ANY
<br />SECTIONS AND PIPE ALREADY LAID AND FOUND TO BE DEFECTIVE OR WHICH HAS HAD GRADE
<br />OR JOINTS DISTURBED.
<br />D. OPENINGS IN PIPES, DRAINS FITTINGS APPARATUS AND EQUIPMENT SHALL BE KEPT COVERED
<br />OR PLUGGED TO PREVENT FOREIGN SUBSTANCE FROM ENTERING.
<br />E. RUN PIPING FREE TO TRAPS, SAGS, OR BENDS. GRADE AND VALVE FOR COMPLETE
<br />DRAINAGE AND CONTROL OF THE SYSTEM.
<br />F. ALL PIPING TO BE RUN TO MAINTAIN HEADROOM AND KEEP PASSAGEWAYS AND OPENINGS
<br />CLEAR. RUN PARALLEL AND STRAIGHT WITH ADJACENT WALLS OR CEILINGS TO PRESENT A
<br />UNIFORM APPEARANCE.
<br />G. ALL PIPING, EXCEPT WHERE NOTED OTHERWISE ON PLANS SHALL BE CONCEALED IN WALLS
<br />OR ABOVE CEILINGS.
<br />H. BENDING OR FORCING OF PIPE WILL NOT BE ALLOWED. USE FITTINGS FOR ALL OFFSETS OR
<br />CHANGES IN ALIGNMENT OF PIPING.
<br />I. PROPER PROVISION SHALL BE MADE FOR EXPANSION AND CONTRACTION BY MEANS OF
<br />FITTINGS AND ANCHORS AND SUPPORTS OF ALL PIPING.
<br />• •
<br />J. STREET ELBOWS, BUSHINGS AND LONG SCREW FITTINGS WILL NOT BE ALL WED.
<br />K. UNIONS SHALL BE INSTALLED AFTER EACH SCREW -TYPE VALVE, CONNECTI NS FOR ALL thsoffim
<br />EQUIPMENT, APPLIANCES AND AS REQUIRED FOR ERECTION AND MAINTENA CE. NO UNIONS -
<br />SHALL BE INSTALLED IN CONCEALED LOCATION.
<br />L. INSTALL ISOLATION UNIONS ON ALL CONNECTIONS BETWEEN DISSIMILAR METALS (GALVANIZED E
<br />STEEL, BLACK STEEL TO COPPER).
<br />M. NO HOLES FOR WITHOUT WRITTEN ICONSENTQOF THE ARCHITECT.
<br />PPE OR EUIPENT WILL BE WHEREWEDI PIPES AREUTOU SSMTHRO R ` PERMIT ISSUANCI
<br />INTERFERE WITH ANY MEMBER, OR WHERE NOCHING, BORING OR CUTTING OF THE STRUCTURE
<br />IS NECESSARY THE WORK SHALL BE DONE BY THE GENERAL CONTRACTOF AS DIRECTED BY KAISER FOUNDATION HOSPITALS
<br />THE ARCHITECT. NATIONAL FACILITIES SERVICES
<br />N. THE CONTRACTOR SHALL, AT A TIME IN ADVANCE OF THE WORK, FURNISH INSTRUCTIONS TO 1800 HARRISON STREET
<br />THE GENERAL CONTRACTOR AS TO HIS REQUIREMENTS FOR OPENINGS, REDESSES, AND OAKLAND, CALIFORNIA 94612
<br />CHASES IN THE WALLS, PARTITIONS, FRAMING OR OPENINGS. SHOULD FURNISHINAL c "'NG THIS
<br />BEINFEQUIIR ON D,BTHEECOSTSEOFDSAMEESH LLIBE°CHARGED TOAND ATHE1000NTRA TOR. 1 ter I D.
<br />0. PROVIDE AND INSTALL POLISHED CHROMIUM PLATE BRASS FLOOR, CEILING OF LL LAq
<br />FOR ALL PIPES, EXPOSED IN FINISHED PORTIONS OF THE BUILDINGS. UC.1'ISSUE / REVISION LOG
<br />P. ALL SCALED AND FIGURED DIMENSIONS ARE APPROXIMATE AND ARE GIVEN FOR ESTIMATE NO. ISSUED DATE
<br />PURPOSES ONLY. BEFORE PROCEEDING WITH ANY WORK, THIS CONTRACTPR SHALL CITY SUBMITTAL 11/03/2025
<br />CAREFULLY CHECK AND VERIFY ALL DIMENSIONS, SIZES, AND SHALL ASSUME FULL
<br />RESPONSIBILITY TO OTHER PARTS OF THE EQUIPMENT, AND TO THE STRUCTURE.
<br />Q. ANY MINOR CHANGES IN WORK, WHICH HAS NOT BEEN INSTALLED, SHALL BE MADE BY THIS
<br />CONTRACTOR WITHOUT ADDITIONAL COMPENSATION, EXCEPT CHANGES WHICH ARE CAUSED BY
<br />ARCHITECTURAL REVISIONS, WHICH INCREASE OR DECREASE THE SIZE OF THE MATERIALS
<br />SPECIFIED OR INDICATED ON THE DRAWINGS. THIS CONTRACTOR SHALL SUBMIT AN ESTIMATE
<br />OF THE COST OF OR CREDIT FOR SUCH CHANGES HE DOES NOT CONSIDER OF A MINOR
<br />NATURE AND SHALL PROCEED ONLY UPON THE WRITTEN AUTHORITY OF THE ARCHITECT.
<br />R. ALL PIPING SHALL BE ISOLATED FROM OTHER PIPING, ANY PART OF THE BUILDING, FRAMING
<br />OR CONDUIT WITH 1" STRIPS OF HAIR FELT OR PIPE ISOLATORS.
<br />3.02 FIXTURE INSTALLATION
<br />A. ALL PLUMBING FIXTURES SHALL BE BEDDED AND CAULKED ALONG JOINT AT COUNTERTOPS,
<br />AND OTHER INTERSECTING SURFACES WITH WHITE SILICONE.
<br />3.03 REQUIREMENTS FOR ACCEPTANCE
<br />A. ALL OF THE FOLLOWING ITEMS MUST BE COMPLETED PRIOR TO FINAL INSPECTIONS. NO
<br />EXCEPTION WILL BE MADE AND NO FINAL PAYMENT WILL BE MADE UNTIL ALL ITEMS ARE
<br />COMPLETED.
<br />B. THOROUGHLY CLEAN ALL PARTS OF THE PIPING, VALVES, AND EQUIPMENT. EXPOSED PARTS
<br />WHICH ARE TO BE PAINTED SHALL BE THOROUGHLY CLEANED OF CEMENT, PLASTER, AND
<br />OTHER MATERIALS AND ALL OIL AND GREASE SPOTS SHALL BE REMOVED. SUCH SURFACES
<br />SHALL BE CAREFULLY WIPED AND ALL CRACKS AND CORNERS SCRAPED OUT.
<br />C. EXPOSED METAL WORK SHALL BE CAREFULLY BRUSHED DOWN WITH STEEL BRUSHES TO
<br />REMOVE RUST AND OTHER SPOTS LEFT SMOOTH AND CLEAN. TRAP ELEMENTS SHALL BE
<br />REMOVED DURING CLEANING AND FLUSHING PERIOD, AFTER WHICH THEY SHALL BE REPLACED
<br />AND ADJUSTED.
<br />3.04 TEST AND ADJUSTMENTS
<br />A. NO PIPING WORK, FIXTURES, OR EQUIPMENT SHALL BE CONCEALED OR COVERED UNTIL THEY
<br />HAVE BEEN INSPECTED AND APPROVED BY THE ENGINEER, WHO SHALL BE NOTIFIED WHEN
<br />THE WORK IS READY FOR INSPECTION. ALL WORK SHALL BE COMPLETELY INSTALLED, TESTED ARCHITECT
<br />AS REQUIRED BY THIS SECTION AND THE STATE ORDINANCES AND STATE SAFETY ORDERS,
<br />AND SHALL BE LEAK -TIGHT BEFORE INSPECTION IS REQUESTED. ALL TESTS SHALL BE
<br />REPEATED UPON REQUEST TO THE SATISFACTION OF THOSE MAKING THE INSPECTION. 'v
<br />�..�
<br />DLLARS
<br />B. ALL DOMESTIC WATER PIPING SHALL BE FLUSHED OUT, TESTED AT TWO TIMES THE WORKING
<br />SYSTEM PRESSURE AND SHALL BE LEFT UNDER PRESSURE OF SUPPLY MAIN OR MINIMUM OF
<br />40 PSI FOR THE BALANCE OF THE CONSTRUCTION PERIOD.
<br />C. TEST PRESSURE IN POUNDS PER SQUARE INCH, OR INCHES OF VACUUM, GAUGE, ARE GIVEN
<br />AS INITIAL PRESSURE TO BE APPLIED TO LINES BEING TESTED, TOGETHER WITH TEST MEDIUM.
<br />555 W. Fifth Street Suite 2950 1 Los Angeles, CA 90013 USA
<br />D. TESTS ARE TO BE APPLIED FOR MINIMUM PERIOD OF TWENTY-FOUR (24) HOURS AND UNTIL Phone 310.820.4600 I Fax 310.207.4215
<br />TEST ARE COMPLETE. www.huitt-zollars.com
<br />E. FINAL PRESSURE AT THE END OF THE TEST PERIOD SHALL BE NO MORE NOR LESS THAN
<br />THAT CAUSED BY EXPANSION OR CONTRACTION OF THE TEST MEDIUM DUE TO TEMPERATURE CONSULTANT ■® ADVANCED
<br />CHANGES.
<br />3.05 CLEANING
<br />A. CLEAN AND DISINFECT POTABLE DOMESTIC WATER PIPING AS FOLLOWS:
<br />1. PURGE NEW PIPING AND PARTS OF EXISTING PIPING THAT HAVE BEEN ALTERED,
<br />EXTENDED, OR REPAIRED BEFORE USING.
<br />2. USE PURGING AND DISINFECTING PROCEDURES PRESCRIBED BY AUTHORITIES HAVING
<br />JURISDICTION; IF METHODS ARE NOT PRESCRIBED, USE PROCEDURES DESCRIBED IN
<br />EITHER AWWA C651 OR AWWA C652 OR FOLLOW PROCEDURES DESCRIBED BELOW:
<br />a. FLUSH PIPING SYSTEM WITH CLEAN, POTABLE WATER UNTIL DIRTY WATER DOES
<br />NOT APPEAR AT OUTLETS.
<br />b. FILL AND ISOLATE SYSTEM ACCORDING TO EITHER OF THE FOLLOWING:
<br />1) FILL SYSTEM OR PART THEREOF WITH WATER/CHLORINE SOLUTION WITH AT
<br />LEAST 50 PPM OF CHLORINE. ISOLATE WITH VALVES AND ALLOW TO STAND
<br />FOR 24 HOURS.
<br />2) FILL SYSTEM OR PART THEREOF WITH WATER/CHLORINE SOLUTION WITH AT
<br />LEAST 200 PPM OF CHLORINE. ISOLATE AND ALLOW TO STAND FOR THREE
<br />HOURS.
<br />c. FLUSH SYSTEM WITH CLEAN, POTABLE WATER UNTIL NO CHLORINE IS IN WATER
<br />COMING FROM SYSTEM AFTER THE STANDING TIME.
<br />d. REPEAT PROCEDURES IF BIOLOGICAL EXAMINATION SHOWS CONTAMINATION.
<br />e. SUBMIT WATER SAMPLES IN STERILE BOTTLES TO AUTHORITIES HAVING
<br />JURISDICTION.
<br />3.06 PIPE LABELS
<br />A. GENERAL REQUIREMENTS FOR MANUFACTURED PIPE LABELS: PREPRINTED, COLOR CODED, WITH
<br />LETTERING INDICATING SERVICE AND SHOWING FLOW DIRECTION IN ACCORDANCE WITH ASME A13.1.
<br />B. LETTER AND BACKGROUND COLOR: BACKGROUND AND LETTERING COLORS SHOULD COMPLY WITH
<br />RECOMMENDATIONS IN ASME A13.1.
<br />C. PRETENSIONED PIPE LABELS: PRECOILED, SEMIRIGID PLASTIC FORMED TO PARTIALLY COVER
<br />CIRCUMFERENCE OF PIPE AND TO ATTACH TO PIPE WITHOUT FASTENERS OR ADHESIVE.
<br />D. SELF-ADHESIVE PIPE LABELS: PRINTED PLASTIC WITH CONTACT -TYPE, PERMANENT -ADHESIVE BACKING.
<br />E. PIPE LABEL CONTENTS: INCLUDE IDENTIFICATION OF PIPING SERVICE USING SAME DESIGNATIONS OR
<br />ABBREVIATIONS AS USED ON DRAWINGS. ALSO INCLUDE:
<br />• FLOW -DIRECTION ARROWS: INCLUDE FLOW -DIRECTION ARROWS ON MAIN DISTRIBUTION PIPING.
<br />ARROWS MAY BE EITHER INTEGRAL WITH LABEL OR APPLIED SEPARATELY.
<br />• LETTERING SIZE: AT LEAST 1/2 INCH FOR VIEWING DISTANCES OF UP TO 72 INCHES AND
<br />PROPORTIONATELY LARGER LETTERING FOR GREATER VIEWING DISTANCES.
<br />3.07 DRAWINGS OF RECORD
<br />A. IN ADDITION TO THE REPRODUCIBLE "AS -BUILT" REQUIRED, TWO COMPLETE SETS OF BLUE
<br />LINE PLUMBING DRAWINGS WILL BE PROVIDED FOR THE PURPOSE OF SHOWING A COMPLETE
<br />PICTURE OF THE WORK AS ACTUALLY INSTALLED.
<br />B. THESE DRAWINGS SHALL SERVE AS WORK PROGRESS REPORT SHEETS AND THE CONTRACTOR
<br />SHALL MAKE ALL NOTATIONS, NEAT AND LEGIBLE, THEREON DAILY AS THE WORK PROCEEDS.
<br />THE DRAWINGS SHALL BE AVAILABLE FOR INSPECTION AT ALL TIMES AND SHALL BE KEPT AT
<br />THE JOB AT A LOCATION DESIGNATED BY THE OWNER.
<br />C. AT COMPLETION OF THE WORK, THESE AS -BUILT DRAWINGS SHALL BE SIGNED BY THE
<br />CONTRACTOR INDICATING HIS APPROVAL, DATED AND RETURNED TO THE OWNER.
<br />D. THE DIMENSIONAL LOCATION OF ALL CONCEALED PIPING SHALL BE ACCURATELY RECORDED
<br />ON THE "AS -BUILT" DRAWINGS.
<br />TECHNOLOGIES
<br />CONSULTANTS, INC.
<br />5755 OBERLIN DR., SUITE #112
<br />SAN DIEGO CA. 92121 OFFlCE (858) 658-0304
<br />www.atconsultants.net FAX (858) 658-0307
<br />ARCHITECT SEAL I CONSULTANT SEAL
<br />M30641
<br />06/30/26
<br />22-HZ-117
<br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO
<br />BE USED WITHOUT OWNER'S WRITTEN PERMISSION.
<br />AGENCY APPLICATION NUMBER
<br />AGENCY APPROVAL STAMP
<br />FACILITY
<br />HARBOR/MacARTHUR MEDICAL OFF
<br />3401 S. HARBOR BLVD.
<br />SANTA ANA, CALIFORNIA 92704
<br />PROJECT
<br />KP HBM 1ST FLR KPOJ
<br />SHEET TITLE
<br />SPECIFICATIONS - PLUMBING
<br />FAC NO: CA-394-1 BLDG NO: - FLOOR LEV: - SECTION: -
<br />HZ PROJ. NO, R314412.35 KP PROJ. NO. CAP027721
<br />PERMIT NO.
<br />PO-02
<br />0 1
<br />
|