0 <br />0 <br />N <br />0 <br />EO <br />0 <br />SPECIFICATIONS -PLUMBING I Plannilnn and Riiilrlinn AnPn <br />PART 1 GENERAL <br />1.01 SCOPE <br />A. THE WORK UNDER THIS SECTION INCLUDES EVERYTHING NECESSARY FOR AND INCIDENTAL TO <br />EXECUTING AND COMPLETING THE PLUMBING WORK, EXCEPT AS HEREINAFTER SPECIFICALLY <br />EXCLUDED. <br />B. WORK INCLUDED SHALL BE AS INDICATED ON THE DRAWINGS, INCLUDING BUT NOT LIMITED TO <br />THE FOLLOWING: <br />1. SANITARY SOIL, WASTE AND VENT SYSTEM. <br />2. DOMESTIC AND INDUSTRIAL HOT AND COLD WATER SYSTEM. <br />3. PLUMBING FIXTURES AND EQUIPMENT. <br />1.02 CODES AND STANDARDS <br />A. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES AND <br />REGULATIONS OF THE FIRE MARSHAL; THE SAFETY ORDERS OF THE DIVISION OF INDUSTRIAL <br />SAFETY; THE CALIFORNIA ELECTRIC CODE; THE CALIFORNIA PLUMBING CODE; THE CALIFORNIA <br />MECHANICAL CODE; OTHER APPLICABLE CODES, LAWS OR REGULATIONS OF BODIES LAWFULLY <br />EMPOWERED AND HAVING JURISDICTION OVER THIS PROJECT. NOTHING IN THE PLANS OR <br />SPECIFICATIONS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. <br />1.03 PERMITS <br />A. CONTRACTOR SHALL OBTAIN ALL PERMITS AND LICENSES THAT ARE REQUIRED FOR THE <br />PERFORMING OF HIS WORK BY ALL LAWS, ORDINANCES, RULES AND REGULATIONS OR <br />ORDERS OF ANY OFFICER AND/OR BODY, SHALL GIVE ALL NOTICES NECESSARY IN <br />CONNECTION THEREWITH, AND PAY ALL FEES RELATING THERETO AND ALL COSTS AND <br />EXPENSES INCURRED ON ACCOUNT THEREOF. NO WORK SHALL BE COVERED BEFORE <br />INSPECTION BY THE JURISDICTIONAL INSPECTION AND THE ARCHITECT. <br />1.04 CUTTING AND PATCHING <br />A. PERFORM ALL CUTTING AND FITTING REQUIRED FOR WORK OF THIS SECTION IN ROUGH <br />CONSTRUCTION OF THE BUILDING. <br />B. ALL PATCHING OF FINISHED CONSTRUCTION OF BUILDING SHALL BE PERFORMED UNDER THE <br />SECTIONS OF SPECIFICATIONS COVERING THESE MATERIALS. <br />C. ALL PATCHING OF EXISTING SURFACES SHALL MATCH EXISTING MATERIALS AND FINISHED. <br />1.05 GENERAL <br />A. UNLESS OTHERWISE SPECIFIED HEREIN, ALL EQUIPMENT AND FIXTURES SHALL BE INSTALLED <br />IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. <br />B. BEFORE SUBMITTING HIS BID, THE CONTRACTOR FOR THE WORK UNDER THIS SECTION SHALL <br />CAREFULLY STUDY ALL DRAWINGS, AND SHALL MAKE A CAREFUL EXAMINATION OF THE <br />PREMISES. HE SHALL DEFINITELY DETERMINE IN ADVANCE, THE METHODS OF INSTALLING AND <br />CONNECTING THE APPARATUS, THE MEANS TO BE PROVIDED FOR GETTING ANY EQUIPMENT <br />INTO PLACE, AND SHALL MAKE HIMSELF THOROUGHLY FAMILIAR WITH ALL THE REQUIREMENTS <br />OF THE CONTRACT. AFTER AWARD OF THE CONTRACT, NO SUBSEQUENT ALLOWANCES WILL BE <br />MADE WITH THE ABOVE REQUIREMENTS AND ANY OTHER CONDITIONS AFFECTING THE <br />INSTALLATION AND COMPLETION OF ALL WORK. <br />C. WORKMANSHIP: ALL LABOR SHALL BE CAREFULLY SKILLED FOR THIS KIND OF WORK, <br />THOROUGH AND FIRST CLASS IN ALL RESPECTS AND UNDER THE DIRECTOR OF A COMPETENT <br />FOREMAN. <br />D. SPECIAL NOTE: ANY WORK CALLED FOR ON PLANS SHALL BE INSTALLED WHETHER OR NOT <br />MENTIONED IN THESE SPECIFICATIONS. <br />1.06 DAMAGE BY LEAKS <br />A. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE GROUNDS, WALKS, ROADS, <br />BUILDINGS, PIPING SYSTEMS, ELECTRICAL SYSTEMS AND THEIR EQUIPMENT AND CONTENTS, <br />CAUSED BY LEAKS IN THE PIPING SYSTEM BEING INSTALLED OR HAVING BEEN INSTALLED <br />HEREIN. HE SHALL REPAIR AT THIS EXPENSE ALL DAMAGE SO CAUSED. ALL REPAIR WORK <br />SHALL BE DONE AS DIRECTED BY THE ARCHITECT. <br />1.07 EMERGENCY REPAIRS <br />A. THE OWNER RESERVES THE RIGHT TO MAKE EMERGENCY REPAIRS AS REQUIRED TO KEEP <br />EQUIPMENT IN OPERATION WITHOUT VOIDING THE CONTRACTOR'S GUARANTEE BOND NOR <br />RELIEVING THE CONTRACTOR OF HIS RESPONSIBILITIES. <br />1.08 EXPLANATION AND PRECEDENCE OF DRAWINGS <br />A. FOR PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC, <br />AND, ALTHOUGH SIZE AND LOCATION OF EQUIPMENT ARE DRAWN TO SCALE WHEREVER <br />POSSIBLE, CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL THE CONTRACT DOCUMENTS <br />AND SHALL VERIFY THIS INFORMATION AT BUILDING SITE. <br />B. THE DRAWINGS INDICATE REQUIRED SIZE AND POINTS OF TERMINATION OF PIPES, AND <br />SUGGEST PROPER ROUTES TO CONFORM TO STRUCTURE, AVOID OBSTRUCTIONS AND <br />PRESERVE CLEARANCES. HOWEVER, IT IS NOT INTENDED THAT DRAWING INDICATE ALL <br />NECESSARY OFFSETS, AND IT SHALL BE THE WORK OF THE CONTRACTOR TO MAKE THE <br />INSTALLATION IN SUCH A MANNER AS TO CONFORM TO STRUCTURE, AVOID OBSTRUCTIONS, <br />PRESERVE HEADROOM AND KEEP OPENING AND PASSAGEWAYS CLEAR, WITHOUT FURTHER <br />INSTRUCTIONS OR COST TO THE OWNER. <br />C. IT IS INTENDED THAT ALL APPARATUS BE LOCATED SYMMETRICAL WITH ARCHITECTURAL <br />ELEMENTS. REFER TO ARCHITECTURAL DETAILS IN COMPLETING THE CORRELATING WORK. <br />D. THE CONTRACTOR SHALL FULLY INFORM HIMSELF REGARDING ANY AND ALL PECULIARITIES <br />AND LIMITATIONS OF THE SPACES AVAILABLE FOR THE INSTALLATION OF ALL WORK AND <br />MATERIALS FURNISHED AND INSTALLED UNDER THE CONTRACT. HE SHALL EXERCISE DUE <br />AND PARTICULAR CAUTION TO DETERMINE THAT ALL PARTS OF HIS WORK ARE MADE QUICKLY <br />AND EASILY ACCESSIBLE. <br />E. THE CONTRACTOR SHALL STUDY ALL DRAWINGS AND SPECIFICATIONS TO DETERMINE ANY <br />CONFLICT WITH ORDINANCES AND STATUTES. ANY ERRORS OR OMISSIONS SHALL BE <br />REPORTED, AND ANY CHANGES SHALL BE SHOWN IN THE AS -BUILT DRAWINGS AND THE <br />ADDITIONAL WORK PERFORMED AT NO COST TO THE OWNER. <br />F. SUBMITTAL OF BID SHALL INDICATE THE CONTRACTOR HAS EXAMINED THE SITE AND DRAWINGS <br />AND HAS INCLUDED ALL REQUIRED ALLOWANCES IN HIS BID. NO ALLOWANCE SHALL BE <br />MADE FOR ANY ERROR RESULTING FROM CONTRACTOR S FAILURE TO VISIT JOB SITE AND TO <br />REVIEW DRAWINGS, AND BID SHALL INCLUDE COSTS FOR ALL REQUIRED DRAWINGS AND <br />CHANGES AS OUTLINED ABOVE, ALL AT NO COST TO OWNER. <br />PART 2 PRODUCTS <br />2.01 FITTINGS AND PIPING <br />A. ALL DOMESTIC WATER PIPING: ABOVE GRADE, "TYPE L" COPPER TUBING, HARD DRAWN WITH <br />WROUGHT COPPER FITTINGS, AND SILVER SOLDERED JOINTS. <br />B. WASTE AND VENT PIPING SHALL BE NO -HUB CAST IRON WITH STAINLESS STEEL AND <br />NEOPRENE TYPE COUPLINGS. <br />2.02 VALVES AND FITTINGS <br />A. ANGLE STOPS <br />1. SEE FIXTURE SCHEDULE ON DRAWINGS. <br />2.03 PLUMBING FIXTURES <br />A. GENERAL REQUIREMENTS <br />1. PROVIDE NEW FIXTURES, APPROVED, FREE FROM FLAWS AND BLEMISHED, WITH FINISHED <br />SURFACES CLEAR, SMOOTH AND BRIGHT. <br />2. VISIBLE PARTS OF FIXTURE BRASS AND ACCESSORIES SHALL BE HEAVILY CHROME PLATED. <br />3. FIXTURES SHALL BE PRODUCT OF ONE MANUFACTURER. FITTING OF SAME TYPE SHALL BE <br />PRODUCTS OF ONE MANUFACTURER. <br />4. PROTECT FIXTURES AGAINST USE AND DAMAGE DURING CONSTRUCTION. <br />B. JOB CONDITIONS <br />1. CONFIRM LOCATION AND SIZE OF FIXTURES AND OPENING BEFORE ROUGH -IN AND <br />INSTALLATION. <br />2. PLUMBING FIXTURE TRIM AND EXPOSED SUPPLIES AND WASTE SHALL BE BRASS WITH <br />POLISHED CHROME PLATED FINISH. INDIVIDUAL LOOSE KEY STOPS, OR SO SPECIFIED, <br />SCREW DRIVER STOPS, SHALL BE PROVIDED FOR ALL SUPPLIES, AND UNLESS INTEGRAL <br />WITH VALVES OR FAUCET, UNLESS, OTHERWISE APPROVED BY ARCHITECT, SHALL BE <br />MOUNTED UNDER THE FIXTURE. EXPOSED SUPPLIES AND WASTES TO WELL SHALL BE <br />PROVIDED WITH POLISHED CHROME PLATED CAST BRASS WELL ESCUTCHEONS. <br />3. SUPPLIES SHALL BE WITH LOOSE KEY STOPS AND FLEXIBLE RISERS. <br />4.TRAPS ABOVE FLOOR SHALL BE CAST BRASS "P" TRAPS WITH BRONZE NUTS UNLESS <br />OTHERWISE INDICATED. <br />C. SEE FIXTURE SCHEDULE ON DRAWINGS. <br />PART 3 EXECUTION <br />3.01 PIPE INSTALLATION <br />A. JOINTS IN COPPER TUBING SHALL BE MADE BY FIRST THOROUGHLY CLEANING THE SURFACE <br />OF THE PIPE AND FITTINGS, APPLYING FLUX AND SWEATING WITH SOLDER. <br />B. PIPE SHALL BE CAREFULLY CLEANED BEFORE INSTALLATION. THE ENDS OF THREADED PIPE <br />SHALL BE REAMED OUT FULL SIZE WITH A LONG TAPER REAMER SO AS TO BE PARTIALLY <br />BELL -MOUTHED AND PERFECTLY SMOOTH. <br />C. FLUSH OUT ALL WATER MAINS AND SANITARY DRAINS WITH WATER SO AS TO OBTAIN FREE <br />FLOW. REMOVE ALL OBSTRUCTIONS AND DEFECTS DISCOVERED. REMOVE AND RELAY ANY <br />SECTIONS AND PIPE ALREADY LAID AND FOUND TO BE DEFECTIVE OR WHICH HAS HAD GRADE <br />OR JOINTS DISTURBED. <br />D. OPENINGS IN PIPES, DRAINS FITTINGS APPARATUS AND EQUIPMENT SHALL BE KEPT COVERED <br />OR PLUGGED TO PREVENT FOREIGN SUBSTANCE FROM ENTERING. <br />E. RUN PIPING FREE TO TRAPS, SAGS, OR BENDS. GRADE AND VALVE FOR COMPLETE <br />DRAINAGE AND CONTROL OF THE SYSTEM. <br />F. ALL PIPING TO BE RUN TO MAINTAIN HEADROOM AND KEEP PASSAGEWAYS AND OPENINGS <br />CLEAR. RUN PARALLEL AND STRAIGHT WITH ADJACENT WALLS OR CEILINGS TO PRESENT A <br />UNIFORM APPEARANCE. <br />G. ALL PIPING, EXCEPT WHERE NOTED OTHERWISE ON PLANS SHALL BE CONCEALED IN WALLS <br />OR ABOVE CEILINGS. <br />H. BENDING OR FORCING OF PIPE WILL NOT BE ALLOWED. USE FITTINGS FOR ALL OFFSETS OR <br />CHANGES IN ALIGNMENT OF PIPING. <br />I. PROPER PROVISION SHALL BE MADE FOR EXPANSION AND CONTRACTION BY MEANS OF <br />FITTINGS AND ANCHORS AND SUPPORTS OF ALL PIPING. <br />• • <br />J. STREET ELBOWS, BUSHINGS AND LONG SCREW FITTINGS WILL NOT BE ALL WED. <br />K. UNIONS SHALL BE INSTALLED AFTER EACH SCREW -TYPE VALVE, CONNECTI NS FOR ALL thsoffim <br />EQUIPMENT, APPLIANCES AND AS REQUIRED FOR ERECTION AND MAINTENA CE. NO UNIONS - <br />SHALL BE INSTALLED IN CONCEALED LOCATION. <br />L. INSTALL ISOLATION UNIONS ON ALL CONNECTIONS BETWEEN DISSIMILAR METALS (GALVANIZED E <br />STEEL, BLACK STEEL TO COPPER). <br />M. NO HOLES FOR WITHOUT WRITTEN ICONSENTQOF THE ARCHITECT. <br />PPE OR EUIPENT WILL BE WHEREWEDI PIPES AREUTOU SSMTHRO R ` PERMIT ISSUANCI <br />INTERFERE WITH ANY MEMBER, OR WHERE NOCHING, BORING OR CUTTING OF THE STRUCTURE <br />IS NECESSARY THE WORK SHALL BE DONE BY THE GENERAL CONTRACTOF AS DIRECTED BY KAISER FOUNDATION HOSPITALS <br />THE ARCHITECT. NATIONAL FACILITIES SERVICES <br />N. THE CONTRACTOR SHALL, AT A TIME IN ADVANCE OF THE WORK, FURNISH INSTRUCTIONS TO 1800 HARRISON STREET <br />THE GENERAL CONTRACTOR AS TO HIS REQUIREMENTS FOR OPENINGS, REDESSES, AND OAKLAND, CALIFORNIA 94612 <br />CHASES IN THE WALLS, PARTITIONS, FRAMING OR OPENINGS. SHOULD FURNISHINAL c "'NG THIS <br />BEINFEQUIIR ON D,BTHEECOSTSEOFDSAMEESH LLIBE°CHARGED TOAND ATHE1000NTRA TOR. 1 ter I D. <br />0. PROVIDE AND INSTALL POLISHED CHROMIUM PLATE BRASS FLOOR, CEILING OF LL LAq <br />FOR ALL PIPES, EXPOSED IN FINISHED PORTIONS OF THE BUILDINGS. UC.1'ISSUE / REVISION LOG <br />P. ALL SCALED AND FIGURED DIMENSIONS ARE APPROXIMATE AND ARE GIVEN FOR ESTIMATE NO. ISSUED DATE <br />PURPOSES ONLY. BEFORE PROCEEDING WITH ANY WORK, THIS CONTRACTPR SHALL CITY SUBMITTAL 11/03/2025 <br />CAREFULLY CHECK AND VERIFY ALL DIMENSIONS, SIZES, AND SHALL ASSUME FULL <br />RESPONSIBILITY TO OTHER PARTS OF THE EQUIPMENT, AND TO THE STRUCTURE. <br />Q. ANY MINOR CHANGES IN WORK, WHICH HAS NOT BEEN INSTALLED, SHALL BE MADE BY THIS <br />CONTRACTOR WITHOUT ADDITIONAL COMPENSATION, EXCEPT CHANGES WHICH ARE CAUSED BY <br />ARCHITECTURAL REVISIONS, WHICH INCREASE OR DECREASE THE SIZE OF THE MATERIALS <br />SPECIFIED OR INDICATED ON THE DRAWINGS. THIS CONTRACTOR SHALL SUBMIT AN ESTIMATE <br />OF THE COST OF OR CREDIT FOR SUCH CHANGES HE DOES NOT CONSIDER OF A MINOR <br />NATURE AND SHALL PROCEED ONLY UPON THE WRITTEN AUTHORITY OF THE ARCHITECT. <br />R. ALL PIPING SHALL BE ISOLATED FROM OTHER PIPING, ANY PART OF THE BUILDING, FRAMING <br />OR CONDUIT WITH 1" STRIPS OF HAIR FELT OR PIPE ISOLATORS. <br />3.02 FIXTURE INSTALLATION <br />A. ALL PLUMBING FIXTURES SHALL BE BEDDED AND CAULKED ALONG JOINT AT COUNTERTOPS, <br />AND OTHER INTERSECTING SURFACES WITH WHITE SILICONE. <br />3.03 REQUIREMENTS FOR ACCEPTANCE <br />A. ALL OF THE FOLLOWING ITEMS MUST BE COMPLETED PRIOR TO FINAL INSPECTIONS. NO <br />EXCEPTION WILL BE MADE AND NO FINAL PAYMENT WILL BE MADE UNTIL ALL ITEMS ARE <br />COMPLETED. <br />B. THOROUGHLY CLEAN ALL PARTS OF THE PIPING, VALVES, AND EQUIPMENT. EXPOSED PARTS <br />WHICH ARE TO BE PAINTED SHALL BE THOROUGHLY CLEANED OF CEMENT, PLASTER, AND <br />OTHER MATERIALS AND ALL OIL AND GREASE SPOTS SHALL BE REMOVED. SUCH SURFACES <br />SHALL BE CAREFULLY WIPED AND ALL CRACKS AND CORNERS SCRAPED OUT. <br />C. EXPOSED METAL WORK SHALL BE CAREFULLY BRUSHED DOWN WITH STEEL BRUSHES TO <br />REMOVE RUST AND OTHER SPOTS LEFT SMOOTH AND CLEAN. TRAP ELEMENTS SHALL BE <br />REMOVED DURING CLEANING AND FLUSHING PERIOD, AFTER WHICH THEY SHALL BE REPLACED <br />AND ADJUSTED. <br />3.04 TEST AND ADJUSTMENTS <br />A. NO PIPING WORK, FIXTURES, OR EQUIPMENT SHALL BE CONCEALED OR COVERED UNTIL THEY <br />HAVE BEEN INSPECTED AND APPROVED BY THE ENGINEER, WHO SHALL BE NOTIFIED WHEN <br />THE WORK IS READY FOR INSPECTION. ALL WORK SHALL BE COMPLETELY INSTALLED, TESTED ARCHITECT <br />AS REQUIRED BY THIS SECTION AND THE STATE ORDINANCES AND STATE SAFETY ORDERS, <br />AND SHALL BE LEAK -TIGHT BEFORE INSPECTION IS REQUESTED. ALL TESTS SHALL BE <br />REPEATED UPON REQUEST TO THE SATISFACTION OF THOSE MAKING THE INSPECTION. 'v <br />�..� <br />DLLARS <br />B. ALL DOMESTIC WATER PIPING SHALL BE FLUSHED OUT, TESTED AT TWO TIMES THE WORKING <br />SYSTEM PRESSURE AND SHALL BE LEFT UNDER PRESSURE OF SUPPLY MAIN OR MINIMUM OF <br />40 PSI FOR THE BALANCE OF THE CONSTRUCTION PERIOD. <br />C. TEST PRESSURE IN POUNDS PER SQUARE INCH, OR INCHES OF VACUUM, GAUGE, ARE GIVEN <br />AS INITIAL PRESSURE TO BE APPLIED TO LINES BEING TESTED, TOGETHER WITH TEST MEDIUM. <br />555 W. Fifth Street Suite 2950 1 Los Angeles, CA 90013 USA <br />D. TESTS ARE TO BE APPLIED FOR MINIMUM PERIOD OF TWENTY-FOUR (24) HOURS AND UNTIL Phone 310.820.4600 I Fax 310.207.4215 <br />TEST ARE COMPLETE. www.huitt-zollars.com <br />E. FINAL PRESSURE AT THE END OF THE TEST PERIOD SHALL BE NO MORE NOR LESS THAN <br />THAT CAUSED BY EXPANSION OR CONTRACTION OF THE TEST MEDIUM DUE TO TEMPERATURE CONSULTANT ■® ADVANCED <br />CHANGES. <br />3.05 CLEANING <br />A. CLEAN AND DISINFECT POTABLE DOMESTIC WATER PIPING AS FOLLOWS: <br />1. PURGE NEW PIPING AND PARTS OF EXISTING PIPING THAT HAVE BEEN ALTERED, <br />EXTENDED, OR REPAIRED BEFORE USING. <br />2. USE PURGING AND DISINFECTING PROCEDURES PRESCRIBED BY AUTHORITIES HAVING <br />JURISDICTION; IF METHODS ARE NOT PRESCRIBED, USE PROCEDURES DESCRIBED IN <br />EITHER AWWA C651 OR AWWA C652 OR FOLLOW PROCEDURES DESCRIBED BELOW: <br />a. FLUSH PIPING SYSTEM WITH CLEAN, POTABLE WATER UNTIL DIRTY WATER DOES <br />NOT APPEAR AT OUTLETS. <br />b. FILL AND ISOLATE SYSTEM ACCORDING TO EITHER OF THE FOLLOWING: <br />1) FILL SYSTEM OR PART THEREOF WITH WATER/CHLORINE SOLUTION WITH AT <br />LEAST 50 PPM OF CHLORINE. ISOLATE WITH VALVES AND ALLOW TO STAND <br />FOR 24 HOURS. <br />2) FILL SYSTEM OR PART THEREOF WITH WATER/CHLORINE SOLUTION WITH AT <br />LEAST 200 PPM OF CHLORINE. ISOLATE AND ALLOW TO STAND FOR THREE <br />HOURS. <br />c. FLUSH SYSTEM WITH CLEAN, POTABLE WATER UNTIL NO CHLORINE IS IN WATER <br />COMING FROM SYSTEM AFTER THE STANDING TIME. <br />d. REPEAT PROCEDURES IF BIOLOGICAL EXAMINATION SHOWS CONTAMINATION. <br />e. SUBMIT WATER SAMPLES IN STERILE BOTTLES TO AUTHORITIES HAVING <br />JURISDICTION. <br />3.06 PIPE LABELS <br />A. GENERAL REQUIREMENTS FOR MANUFACTURED PIPE LABELS: PREPRINTED, COLOR CODED, WITH <br />LETTERING INDICATING SERVICE AND SHOWING FLOW DIRECTION IN ACCORDANCE WITH ASME A13.1. <br />B. LETTER AND BACKGROUND COLOR: BACKGROUND AND LETTERING COLORS SHOULD COMPLY WITH <br />RECOMMENDATIONS IN ASME A13.1. <br />C. PRETENSIONED PIPE LABELS: PRECOILED, SEMIRIGID PLASTIC FORMED TO PARTIALLY COVER <br />CIRCUMFERENCE OF PIPE AND TO ATTACH TO PIPE WITHOUT FASTENERS OR ADHESIVE. <br />D. SELF-ADHESIVE PIPE LABELS: PRINTED PLASTIC WITH CONTACT -TYPE, PERMANENT -ADHESIVE BACKING. <br />E. PIPE LABEL CONTENTS: INCLUDE IDENTIFICATION OF PIPING SERVICE USING SAME DESIGNATIONS OR <br />ABBREVIATIONS AS USED ON DRAWINGS. ALSO INCLUDE: <br />• FLOW -DIRECTION ARROWS: INCLUDE FLOW -DIRECTION ARROWS ON MAIN DISTRIBUTION PIPING. <br />ARROWS MAY BE EITHER INTEGRAL WITH LABEL OR APPLIED SEPARATELY. <br />• LETTERING SIZE: AT LEAST 1/2 INCH FOR VIEWING DISTANCES OF UP TO 72 INCHES AND <br />PROPORTIONATELY LARGER LETTERING FOR GREATER VIEWING DISTANCES. <br />3.07 DRAWINGS OF RECORD <br />A. IN ADDITION TO THE REPRODUCIBLE "AS -BUILT" REQUIRED, TWO COMPLETE SETS OF BLUE <br />LINE PLUMBING DRAWINGS WILL BE PROVIDED FOR THE PURPOSE OF SHOWING A COMPLETE <br />PICTURE OF THE WORK AS ACTUALLY INSTALLED. <br />B. THESE DRAWINGS SHALL SERVE AS WORK PROGRESS REPORT SHEETS AND THE CONTRACTOR <br />SHALL MAKE ALL NOTATIONS, NEAT AND LEGIBLE, THEREON DAILY AS THE WORK PROCEEDS. <br />THE DRAWINGS SHALL BE AVAILABLE FOR INSPECTION AT ALL TIMES AND SHALL BE KEPT AT <br />THE JOB AT A LOCATION DESIGNATED BY THE OWNER. <br />C. AT COMPLETION OF THE WORK, THESE AS -BUILT DRAWINGS SHALL BE SIGNED BY THE <br />CONTRACTOR INDICATING HIS APPROVAL, DATED AND RETURNED TO THE OWNER. <br />D. THE DIMENSIONAL LOCATION OF ALL CONCEALED PIPING SHALL BE ACCURATELY RECORDED <br />ON THE "AS -BUILT" DRAWINGS. <br />TECHNOLOGIES <br />CONSULTANTS, INC. <br />5755 OBERLIN DR., SUITE #112 <br />SAN DIEGO CA. 92121 OFFlCE (858) 658-0304 <br />www.atconsultants.net FAX (858) 658-0307 <br />ARCHITECT SEAL I CONSULTANT SEAL <br />M30641 <br />06/30/26 <br />22-HZ-117 <br />THIS DOCUMENT IS THE PROPERTY OF THE OWNER AND IS NOT TO <br />BE USED WITHOUT OWNER'S WRITTEN PERMISSION. <br />AGENCY APPLICATION NUMBER <br />AGENCY APPROVAL STAMP <br />FACILITY <br />HARBOR/MacARTHUR MEDICAL OFF <br />3401 S. HARBOR BLVD. <br />SANTA ANA, CALIFORNIA 92704 <br />PROJECT <br />KP HBM 1ST FLR KPOJ <br />SHEET TITLE <br />SPECIFICATIONS - PLUMBING <br />FAC NO: CA-394-1 BLDG NO: - FLOOR LEV: - SECTION: - <br />HZ PROJ. NO, R314412.35 KP PROJ. NO. CAP027721 <br />PERMIT NO. <br />PO-02 <br />0 1 <br />