Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />412 <br />3612 <br />=5x6 =1x4 <br />=3x4 <br />=3x4 <br />=3x4 <br />=3x4 <br />=1.5x4 <br />=6x8 <br />=3x6 <br />=5x8 <br />=3x4 <br />=3x4 <br />=3x4 <br />=1x4 =5x6 <br />1 <br />17 16 <br />15 <br />14 13 12 <br />2 112435 <br />25 26 34 <br />3 10 <br />27 33 <br />4 9 <br />28 3229583130 <br />7 <br />6 <br />1-0-0 <br />-1-0-0 <br />0-10-12 <br />14-4-8 <br />2-10-8 <br />17-3-0 <br />3-6-2 <br />13-5-12 <br />4-6-15 <br />9-11-9 <br />4-7-6 <br />21-10-6 <br />4-7-15 <br />26-6-5 <br />5-4-11 <br />5-4-11 <br />5-5-11 <br />32-0-0 <br />2-8-12 <br />17-3-0 <br />4-6-11 <br />14-6-4 <br />4-6-15 <br />9-11-9 <br />4-7-6 <br />21-10-6 <br />4-7-15 <br />26-6-5 <br />5-4-11 <br />5-4-11 <br />5-5-11 <br />32-0-0 <br />6- <br />9 <br />- <br />1 <br />2 <br />0- <br />3 <br />- <br />1 <br />5 <br />1- <br />4 <br />- <br />9 <br />5- <br />1 <br />- <br />7 <br />5- <br />1 <br />- <br />7 <br />1- <br />4 <br />- <br />9 <br />6- <br />6 <br />- <br />0 <br />Scale = 1:58.7 <br />Plate Offsets (X, Y):[2:0-3-3,Edge], [5:0-5-8,0-1-0], [11:0-3-3,Edge], [14:0-4-0,0-3-0] <br />Loading (psf)Spacing 2-3-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP <br />TCLL (roof) 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) -0.20 14-15 >999 240 MT20 220/195 <br />TCDL 16.0 Lumber DOL 1.25 BC 0.72 Vert(CT) -0.76 13-14 >502 180 <br />BCLL 0.0*Rep Stress Incr NO WB 0.51 Horz(CT) 0.23 11 n/a n/a <br />BCDL 10.0 Code IBC2021/TPI2014 Matrix-MP Weight: 156 lb FT = 20% <br />LUMBER <br />TOP CHORD 2X4 DF No.1&Btr G *Except* 6-11:2X4 DF <br />No.2 G <br />BOT CHORD 2X4 DF No.1&Btr G <br />WEBS 2X4 DF Std G <br />BRACING <br />TOP CHORD 2-0-0 oc purlins (2-5-6 max.), except end <br />verticals <br />(Switched from sheeted: Spacing > 2-0-0). <br />BOT CHORD Rigid ceiling directly applied or 8-4-1 oc <br />bracing. <br />REACTIONS (lb/size) 2=1764/0-3-8, 11=1672/0-3-8 <br />Max Horiz 2=-130 (LC 9) <br />Max Uplift 2=-239 (LC 8), 11=-189 (LC 9) <br />FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 <br />(lb) or less except when shown. <br />TOP CHORD 2-24=-1588/269, 2-24=-1569/271, <br />2-25=-4429/795, 25-26=-4387/799, <br />3-26=-4383/809, 3-27=-3746/752, <br />4-27=-3688/763, 4-28=-3004/691, <br />28-29=-2938/693, 5-29=-2918/698, <br />8-32=-2880/580, 9-32=-2941/570, <br />9-33=-3648/639, 10-33=-3708/629, <br />10-34=-4384/710, 11-34=-4433/699, <br />11-35=-1537/238, 11-35=-1553/237, <br />5-15=-53/616 <br />BOT CHORD 2-17=-651/4162, 16-17=-651/4162, <br />15-16=-548/3502, 14-15=-424/2789, <br />13-14=-488/3462, 12-13=-619/4166, <br />11-12=-619/4166 <br />WEBS 8-14=-152/707, 4-16=0/423, 3-16=-746/143, <br />4-15=-888/182, 5-8=-2700/632, 9-13=0/453, <br />9-14=-910/166, 10-13=-771/158 <br />NOTES <br />1) Unbalanced roof live loads have been considered for <br />this design. <br />2) Wind: ASCE 7-16; Vult=110mph (3-second gust) <br />Vasd=87mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. <br />II; Exp C; Enclosed; MWFRS (envelope) exterior zone <br />and C-C Exterior(2E) -1-0-9 to 2-1-14, Interior (1) 2-1-14 <br />to 14-6-4, Exterior(2E) 13-5-3 to 16-7-9, Interior (1) <br />16-7-9 to 32-0-0 zone; cantilever left and right exposed ; <br />end vertical left and right exposed;C-C for members and <br />forces & MWFRS for reactions shown; Lumber <br />DOL=1.60 plate grip DOL=1.60 <br />3) This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />4) * This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />5) A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />6) Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 189 lb uplift at joint <br />11 and 239 lb uplift at joint 2. <br />7) This truss has been designed for a moving concentrated <br />load of 250.0lb live located at all mid panels and at all <br />panel points along the Top Chord, nonconcurrent with <br />any other live loads. <br />8) Graphical purlin representation does not depict the size <br />or the orientation of the purlin along the top and/or <br />bottom chord. <br />LOAD CASE(S) Standard <br />Job Truss Truss Type Qty Ply 1002 - 1004 N Van Ness Ave <br />R91123178 <br />A04 Roof Special 2 1250894-ADU Job Reference (optional) <br />Stone Truss, Inc., Oceanside, CA - 92054,Run: 8.73 E Aug 13 2025 Print: 8.730 E Aug 13 2025 MiTek Industries, Inc. Thu Nov 06 16:54:05 Page: 1 <br />ID:3y4?aRvdiVSX2qfA69yelvyNsSo-T0Gl1iwCobvBDawuKVC3Ie_dQ51D1PFe72ZdnKyLpZG <br />November 6,2025