My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5117 W First St & 5117 3%4 W First St #WCC01 - Plan
PBA
>
Building
>
ProjectDox
>
F
>
First St
>
5117 W First St
>
5117 W First St & 5117 3%4 W First St #WCC01 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2026 5:00:17 AM
Creation date
2/23/2026 5:00:07 AM
Metadata
Fields
Template:
Plan
Permit Number
101124969
101124970
Full Address
5117 W First St
5117 3/4 W First St Unit# WCC01
Street Number
5117
Partial
3/4
Street Direction
W
Street Name
First
Street Suffix
St
Unit Number
WCC01
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Criteria <br />I. Applicable Codes <br />-California Building Code (CBC) 2022 <br />-ASCE 7-16 <br />-TIA 222-H <br />-AISC 360-16 <br />-AISC 341-16 <br />-ACI 318-19 <br /> <br />II. Scope of Work <br />This project consists of replacing existing antennas with new antennas. All antennas will be mounted <br />onto new antenna mounts attached to an existing frp screen and a new steel H-frame. <br /> <br />New Antenna Equipment (see architectural plans for quantities and locations): <br /> <br />1. ERICSSON AIR6419 B41 <br />2. APXVAALL18 43-U-NA20 <br />3. RRUS 4480 B71+B85 <br />4. RRUS 4460 B25+B66 <br /> <br />III. Structural Assessment <br /> <br />Mount Stress Level with Proposed Equipment 44.0% PASS <br />New H-FRAME 68.7% PASS <br /> <br />IV. Provisions of Analysis & Disclaimer <br /> <br />Our structural calculations are completed assuming all information provided to us is accurate and <br />applicable to this site. For the purposes of calculations, we assume an overall structure condition of <br />“like new” and all members, connections, anchors, and surfaces to be free of corrosion and/or <br />structural defects. The structure owner and/or contractor shall verify the structure’s condition prior <br />to installation of any proposed equipment. If actual conditions differ from those described in this <br />report, the Engineer of record should be notified immediately to complete a revised evaluation. <br />T-MOBILE <br />LA02034A <br />1 of 28