•ALL GROUNDING PER CEC 250 & 690 <br />•THE DE-RATE FACTOR FOR CONDUCTORS IN RACEWAY THRU AN ATTIC PER [NEC 310.15(2)(B)], THE LOCATION OF THE DC RACEWAYS <br />BENEATH THE ROOF, TO NOT BE CLOSER THAN, & RUN PERPENDICULAR TO, 10" OF THE ROOF DECK AS REQUIRED BY, PROVIDE A <br />VISUAL BREAK UTILITY DISCONNECT AT THE SERVICE METER LOCATION <br />•WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT, AS WELL AS, THE NEW ELECTRICAL EQUIPMENT WILL BE <br />MAINTAINED IN ACCORDANCE <br />•SPACING MUST BE MAINTAINED BETWEEN ANY PLUMBING SEWER VENTS EXTENDING THROUGH THE ROOF & THE UNDERSIDE OF THE <br />PHOTOVOLTAIC PANELS MAINTAIN 12” MINIMUM HORIZONTALLY THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS [UL 1741] <br />COMPLIANT <br />•ALL METALLIC RACEWAYS & EQUIPMENT SHALL BE BONDED & ELECTRICALLY CONTINUOUS. <br />•PHOTOVOLTAIC ARRAYS SHALL BE PROVIDED W/ DC GROUND-FAULT PROTECTION. <br />•DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED ACCORDINGLY <br />•AC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED ACCORDINGLY <br />•GROUND BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM <br />•THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE <br />AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 COPPER WIRE <br />•THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES WITH IRREVERSIBLE COMPRESSION TYPE <br />CONNECTOR <br />#10-24 S.S. <br />LOCK NUT <br />#10-24 S.S. EXTERNAL <br />TOOTH LOCK <br />'STAR' WASHER <br />#10-24 x 3 4" S.S.HCS BOLT <br />S.S. SET SCREWINCLUDED <br />LAY IN LUG TERMINAL <br />AL/CU DUAL RATED <br />(TIN PLATED CU) <br />LOCKNUT <br />'EMT' CONDUIT <br />'EMT' CONNECTOR <br />CONTINUOUS <br />GROUND STRIP <br />INSULATION <br />#6 AWG BARE <br />CU WIRE <br />SEALING LOCKNUT <br />AS NEEDED <br />GROUND BUSHING <br />W/ LAY-IN LUG <br />#6 AWG BARE CU <br />WIRE <br />#6 AWG BARE CU WIRE <br />MICRO-INVERTER <br />*SELF GROUNDED <br />BONDING BASE <br />'SPLICE BAR' <br />JUNCTION BOX <br />MODULESTANDARD RAIL <br />*SELF GROUNDED <br /> BONDING & GROUNDING TO BE FIELD VERIFIED! <br />GROUNDING GENERAL NOTES <br />BONDING BASE'SPLICE BAR' <br />GROUNDING DETAILS <br />PREPARED BY:DATE: <br />PROJECT NUMBER: <br />SHEET NAME: <br />SHEET NUMBER: <br />PROPOSED EQUIPMENT:SCOPE OF WORK:HOMEOWNER:CONTRACTOR: <br />E.01 <br />ELECTRICAL1/21/2026 <br />TG-388 <br />ABRAHAM BRITO <br />1407 N. KING ST. (ADU) <br />SANTA ANA | CA | 92706 <br />APN #: 004-030-10 <br />S <br />EW ELECTRICAL LAYOUT <br />N <br />ALEX J. CLUCK <br />Alex J. Cluckx <br />SCALE: 1/8" = 1'-0" <br />NEMA 3R <br />JUNCTION BOX <br />T&G ROOFING AND SOLAR COMPANY <br />CSLB #583458 (B|C-39|C-10|HIC) <br />153 N. 10TH ST. UPLAND, CA 91786 <br />(909) 931-3204Roofing & Solar Company <br />ROOFING · GUTTERS <br />GENERATORS · SOLAR <br /> (6) SILFAB: SIL-440 QD (MODS.) <br /> (6) ENPHASE: IQ8MC-72-M-US (MICRO-INVS.) <br /> (1) ENPHASE: IQBATTERY-5P-1P-NA (ESS) <br />CONDUCTOR RACEWAY DETAILS <br />•TYPE: FMC <br />•SIZE: 3/4-IN. <br />•TO BE INSTALLED IN ATTIC <br />•TO BE 7/8-IN. OFF OF SURFACE <br />(EXACT LOCATION TO VARY) <br /> 2.64kW (DC) | 2.41kW (CEC-AC) SOLAR W/ 5kWh BATTERIES <br />INSTALL A NEW ENERGY STORAGE SYSTEM ON NEW ADU . WORK TO BE CONDUCTED <br />UNDER AN ACTIVE CSLB LICENSE SHALL ADHERE TO APPLICABLE CODES. <br />*SEE CODE(S) REFERENCED THROUGHOUT THIS PLAN SET FOR COMPLIANCE <br />ENPHASE: IQ8MC-72-M-US <br />MICRO-INVERTER <br />ENPHASE: IQBATTERY-5P-1P-NA <br />20A|240V (ESS #1) <br />ENPHASE: COMBINER BOX 80A|240V <br />AC DISCONNECT 60A|240V <br />MAIN SERVICE PANEL | UTILITY