My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1995 S Standard Ave- Bays - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Standard Ave
>
1995 S Standard Ave
>
1995 S Standard Ave- Bays - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:00:32 AM
Creation date
2/24/2026 5:00:08 AM
Metadata
Fields
Template:
Plan
Permit Number
101121135
Full Address
1995 S Standard Ave
Street Number
1995
Street Direction
S
Street Name
Standard
Street Suffix
Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PUMP ROOM <br />RA <br />M <br />P <br />123456789101112131415161718192021222324252627 <br />32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 <br />474849 40414243444546 28293031323334373839 3536 <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />Space Uses / Types Square <br />Footage Parking Ratio Total Parking <br />Stalls <br />Warehouse distribution 293,977 1:1000 294 <br />Total Required 294 <br />PARKING SUMMARY <br />Total <br />Required <br />Total <br />Provided Variance <br />Standard Parking Stalls 294 295 1 <br />Truck parking 49 <br />Accessible Parking Stalls 5 6 1 <br />Van Accessible Parking Stalls 2 3 1 <br />PARKING CALCULATIONS <br />x <br />xxxxxxx <br />KEYNOTES <br />Parking stalls in area indicated will be removed for electrical service upgrade <br />equipment. Refer to electrical drawings. <br />Provide new as required, accessible parking signs, see detail 05/A0.31. <br />Existing accessible parking stall asphalt painted signage, see detail 04/A0.31 <br />Existing "NO PARKING" on the ground within each access aisle. 12" minimum <br />high white letters that are visible to traffic enforcement officials. Lettering to <br />comply with CBC 11B-502.3.3 and 11B-208. <br />Existing 4" Blue Striping Typ. between accessible stalls. <br />Existing truncated domes, see detail 02/A0.31. <br />Provide new truncated domes, see detail 03 & 06/A0.31. <br />Existing corner curb ramp and truncated domes per detail 01/A0.31. <br />Accessible path of travel, contractor to verify slopes comply in the field, refer <br />to Site Plan Notes. <br />Existing parking lot signage, see detail 07/A0.31. <br />Provide parking striping for (10) new stalls, match existing double stripe. See <br />detail 10/A0.31. <br />Provide new as required, precast concrete wheel stops. Wheel stops not less <br />than 6" in height in situations where wheel stops are necessary to prevent <br />encroachment into structures, landscaped or pedestrian areas. <br />Provide Path of Travel signage, see detail 13/A0.31. <br />01 <br />01 <br />NO <br />PARKING <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />N <br />02 <br />03 <br />04 <br />05 <br />06 <br />07 <br />08 <br />09 <br />1010 <br />SITE NOTES <br />1. Accessible routes shall comply with 11B-402. <br />2. The running slope of walking surfaces shall not be steeper than 1:20. The <br />cross slope of walking surfaces shall not be steeper than 1:48. <br />3. Clear width for sidewalks and walks shall be 48" minimum. Clear width <br />for aisles shall be 36" minimum if serving elements on only one side, and <br />44" minimum if serving elements on both sides. <br />4. All walks with continuous gradients shall have resting areas, 60" in length, <br />at intervals of 400'-0' maximum. The resting area shall be at least as wide <br />as the walk. The slope of the resting area in all directions shall be 1:48 <br />maximum. <br />5. Parking spaces and access aisles serving them shall comply with section <br />11B-302. Access aisles shall be at the same level as the parking spaces <br />they serve. Changes in level, slopes exceeding 1:48, and detectable <br />warnings shall not be permitted. <br />6. Changes in level greater than 1/2" high shall be ramped and shall comply <br />with section 11B-405 or 11B-406. <br />7. Ramp runs shall have a running slope of not steeper than 1:12. Cross <br />slope of ramp runs shall not be steeper than 1:48. <br />8. Clear width of a ramp run shall be 48" minimum. Handrails may project <br />into the required clear width of the ramp at each side 3-1/2" maximum at <br />the handrail height. <br />9. The rise for any ramp run shall be 30" maximum. <br />10. Ramps shall have landings at the top and the bottom of each ramp run. <br />Landings shall comply with 11B-302. Changes in level, slopes exceeding <br />1:48, and detectable warnings shall not be permitted. <br />11. The landing clear width shall be at least as wide as the widest ramp run <br />leading to the landing. Top landings shall be 60" wide minimum. <br />12. The landing clear length shall be 60" long minimum. Bottom landings <br />shall extend 72" minimum in the direction of ramp run. <br />13. Ramps that change direction between runs at landings shall have a clear <br />landing 60" minimum by 72" minimum in the direction of travel from the <br />upper ramp run. <br />0909 <br />02 <br />02 <br />03 <br />03 <br />0203 <br />0203 <br />0203 <br />05 <br />05 <br />06 <br />08 <br />06 <br />06 <br />08 <br />10 <br />05 <br />143'-0"64'-11" <br />60 <br />' <br />- <br />0 <br />" <br />19 <br />6 <br />' <br />- <br />9 <br />" <br />11 <br />11 <br />1801 1895 1995 <br />04 <br />0428 <br />33 <br />09 09 11 <br />05 <br />05 <br />10 <br />10 <br />10 <br />10 <br />09 <br />10 <br />03 <br />09 09 <br />10 <br />06 <br />10 <br />10 <br />09 <br />03 <br />11 <br />32'-0" <br />23'-0" <br />min 23'-0" <br />min <br />23 <br />' <br />- <br />0 <br />" <br />mi <br />n <br />23'-0" <br />min <br />42 <br />' <br />- <br />6 <br />" <br />04 <br />04 <br />Standard Avenue <br />07 <br />12 <br />12 <br />12 <br />12 <br />12 <br />13 <br />11A0.31 <br />13 <br />A0.30 <br />Site Plan <br />1/32" = 1'-0" <br />4 E x e c u t i v e C i r c l e <br />Suite 100, Irvine, CA 92708 <br />w w w . s y m m e t r y 8 . c o m <br />©2023 Symmetry 8 Studio <br />SYMMETRY <br />E I G H TS T U D I O <br />Delta Date Issued For- 09/15/23 Plan Check1 07/11/24 Corrections2 08/12/24 Corrections <br />16000.005 <br />JW <br />Behr <br />1801 S. Standard Avuenue <br />Santa Ana, CA 92707 <br />2 <br />2 <br />2 <br />2 <br />2
The URL can be used to link to this page
Your browser does not support the video tag.