Laserfiche WebLink
# <br />CAT5E 600V RATED SHIELDED CABLE. <br />INSTALLER SHALL FOLLOW <br />MANUFACTURES RECOMMENDATION FOR <br />WIRE SIZING BASED ON LENGTH. <br />EQUIPMENT INDEX <br />EQUIPMENT TYPE <br />SYSTEM IDENTIFIER X INDICATES LETTERS <br /># INDICATES NUMBERS <br />XX-#.# <br />SYSTEM SUMMARY <br />40.00 ACKW | 54.12 DCKW | 50.01 CECKW <br /> 30.00 BESS ACKW | 87.30 BESS KWH <br />TOTAL FAULT CURRENTS <br />UTILITY: 42,000A | GENERATORS: 281A <br />+- <br />18 <br />14 <br />1 <br />13 <br />14 <br />ES-1 <br />(3 <br />) <br /> <br />S <br />O <br />L <br />A <br />R <br />E <br />D <br />G <br />E <br /> <br />B <br />A <br />T <br />- <br />1 <br />0 <br />K <br />1 <br />P <br /> <br />B <br />A <br />T <br />T <br />E <br />R <br />I <br />E <br />( <br />S <br />) <br />ST <br />R <br />- <br />1 <br />. <br />1 <br />. <br />A <br /> <br />- <br /> <br />( <br />1 <br />2 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />2 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />1 <br />. <br />1 <br />. <br />B <br /> <br />- <br /> <br />( <br />1 <br />2 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />2 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />1 <br />. <br />1 <br />. <br />C <br /> <br />- <br /> <br />( <br />1 <br />1 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />1 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ES-2 <br />DC-1.1.1 <br />SO <br />L <br />A <br />R <br />3 <br />16 BA <br />T <br />T <br />E <br />R <br />Y <br />7 <br />12 <br />4A <br />A-B <br />60A <br />INV-1.1 <br />+- <br />18 <br />14 <br />1 <br />13 <br />14 <br />ES-1 <br />(3 <br />) <br /> <br />S <br />O <br />L <br />A <br />R <br />E <br />D <br />G <br />E <br /> <br />B <br />A <br />T <br />- <br />1 <br />0 <br />K <br />1 <br />P <br /> <br />B <br />A <br />T <br />T <br />E <br />R <br />I <br />E <br />( <br />S <br />) <br />ST <br />R <br />- <br />1 <br />. <br />2 <br />. <br />A <br /> <br />- <br /> <br />( <br />1 <br />2 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />2 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />1 <br />. <br />2 <br />. <br />B <br /> <br />- <br /> <br />( <br />1 <br />1 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />1 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />1 <br />. <br />2 <br />. <br />C <br /> <br />- <br /> <br />( <br />1 <br />1 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />1 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ES-2 <br />DC-1.2.2 <br />SO <br />L <br />A <br />R <br />3 <br />16 BA <br />T <br />T <br />E <br />R <br />Y <br />7 <br />12 <br />4A <br />B-C <br />60A <br />INV-1.2 <br />+- <br />18 <br />14 <br />1 <br />13 <br />14 <br />ES-1 <br />(3 <br />) <br /> <br />S <br />O <br />L <br />A <br />R <br />E <br />D <br />G <br />E <br /> <br />B <br />A <br />T <br />- <br />1 <br />0 <br />K <br />1 <br />P <br /> <br />B <br />A <br />T <br />T <br />E <br />R <br />I <br />E <br />( <br />S <br />) <br />ST <br />R <br />- <br />1 <br />. <br />3 <br />. <br />A <br /> <br />- <br /> <br />( <br />1 <br />2 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />2 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />1 <br />. <br />3 <br />. <br />B <br /> <br />- <br /> <br />( <br />1 <br />1 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />1 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />1 <br />. <br />3 <br />. <br />C <br /> <br />- <br /> <br />( <br />1 <br />1 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />1 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ES-2 <br />DC-1.3.3 <br />SO <br />L <br />A <br />R <br />3 <br />16 BA <br />T <br />T <br />E <br />R <br />Y <br />7 <br />12 <br />4A <br />C-A <br />60A <br />INV-1.3 <br />18 <br />14 <br />1 <br />ST <br />R <br />- <br />1 <br />. <br />4 <br />. <br />A <br /> <br />- <br /> <br />( <br />1 <br />5 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />5 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />ST <br />R <br />- <br />1 <br />. <br />4 <br />. <br />B <br /> <br />- <br /> <br />( <br />1 <br />4 <br />) <br /> <br />4 <br />1 <br />0 <br />W <br /> <br />M <br />O <br />D <br />U <br />L <br />E <br /> <br />W <br />/ <br /> <br />( <br />1 <br />4 <br />) <br /> <br />U <br />6 <br />5 <br />0 <br /> <br /> <br />O <br />P <br />T <br />S <br />. <br />DC-1.4.4 <br />3 <br />17 <br />7 <br />1 <br />4B <br />12 <br />2 <br />A-B-C <br />35A <br />INV-1.4 <br />6 <br />LC-1.1 <br />6 <br />8 <br />5 <br />(N) ACDS-2 SYSTEM AC DISCONNECT <br />SWITCH,, SQUARE D, VHU364R, 600V RATED, <br />208V OPERATIONAL, 200A, 3 POLE, <br />NON-FUSIBLE, NEMA 3R. SEE REFERENCE <br />SHEETS FOR KAIC RATING. <br />AC-1.2 <br />M9 <br />4 <br />(N) SCE PV PRODUCTION METER SOCKET <br />ADDRESS: 816 N FIGUEROA ST BLDG A <br />SOMAH1, COOPER B-LINE, 127TB, 200 A, <br />SERVICE 3 PHASE 4 WIRE 120/208 VOLT WYE, <br />NEMA 3R <br />AC-1.2 <br />10 <br />3 <br />(N) ACDS-1 SYSTEM UTILITY AC DISCONNECT <br />SWITCH, SQUARE D, VH324NR, 240V RATED, <br />208V OPERATIONAL, 200A, 3 POLE, FUSIBLE, <br />NEMA 3R, OR EQUIVALENT ON THE UTILITIES <br />APPROVED LIST. CLASS R FUSE WITH <br />REJECTION CLIPS OR CLASS J FOR 200KAIC <br />RATING. <br />A-B-C <br />150AAC-1.1 <br />M <br />M <br />M <br />M <br />M FACILITY <br />LOADS <br />(N) TENANT <br />METERS (TYP.) <br />UTILITY METER REFERENCE NUMBER: <br />259000-081403 <br />SCE UTILITY GRID 208V, <br />3ø,4W <br />(N) LUGS ON (E) <br />HOLES <br />- <br />A <br />11101 <br />600A <br />(N) CABLE <br />LIMITERS16 <br />SUPPLY SIDE TAP OF INTERCONNECTION <br />UTILITY SECTION <br />CUSTOMER SECTION <br />SCE PULL SECTION <br />SCE METERS <br />A INTERCONNECTION LOCATION <br />NTS <br />1. PV MODULES (132) QCELLS NORTH <br />AMERICA Q.PEAK DUO BLK ML-G10.C+ 410 <br />2. (132) SOLAREDGE DC OPTIMIZER U650 <br />3. DC PV AND ESS CONNECTION UNIT W/ <br />INTEGRAL LOAD BREAK DISCONNECT <br />4. 4A: (3) SOLAREDGE SE11400H-US HOME <br />HUB [208V] [SI1-SB] [CRD-PCS NEM], <br />10,000W, 208VAC, 1ø, 3W <br />4B: (1) SOLAREDGE SE10KUS [208V] <br />[SI1-SB], 10,000W, 208VAC, 3ø, 4W <br />5. NOT USED. <br />6. (1) LOAD CENTER, 200A, 3ø, MIN.208VAC, <br />MIN. 22KAIC, NEMA 3R <br />7. NOT USED <br />8.(N) ACDS-2 SYSTEM AC DISCONNECT <br />SWITCH, SQUARE D, VHU364R, 600V <br />RATED, 208V OPERATIONAL, 200A, 3 POLE, <br />NON-FUSIBLE, NEMA 3R. SEE REFERENCE <br />SHEETS FOR KAIC RATING. <br />9. (N) SCE PV PRODUCTION METER SOCKET <br />ADDRESS: 816 N FIGUEROA ST BLDG A <br />SOMAH1, COOPER B-LINE, 127TB, 200A, <br />SERVICE: 3 PHASE 4 WIRE 120/208 VOLT <br />WYE, 7 JAW, NEMA 3R, EUSERC: 305 <br />10. (N) ACDS-1 SYSTEM UTILITY AC <br />DISCONNECT SWITCH, SQUARE D, <br />VH324NR, 240V RATED, 208V <br />OPERATIONAL, 200A, 3 POLE, FUSIBLE, <br />NEMA 3R, OR EQUIVALENT ON THE <br />UTILITIES APPROVED LIST. CLASS R FUSE <br />WITH REJECTION CLIPS OR CLASS J FOR <br />200KAIC RATING. <br /> 11. (E) MAIN SERVICE EQUIPMENT: 3 PHASE <br />4 WIRE 120/208 VOLT WYE, 1000A <br />12. (N) 3 PHASE: CELL-B-R05-US-S-S4 <br />COMMERCIAL CELL CARD OR <br />EQUIVALENT, 1 PHASE: MANUFACTURER <br />INTERGRATED CELL CARD <br />13. (9) SOLAREDGE BAT-10K1P BATTERIES, <br />9.70KWH, 5,000DCW, NEMA 3R, MOUNTED <br />TO WALL OR MANUFACTURER FLOOR <br />MOUNT KIT <br />14. NOT USED <br />15. NOT USED <br />16. (6) 1/0 AWG CABLE LIMITER <br />1.(E) MAIN SWITCHGEAR AND (N) POINT OF <br />AC INTERCONNECTION. ALL <br />CONNECTIONS MADE INSIDE (E) <br />SWITCHGEAR AT OTHER THAN CIRCUIT <br />BREAKERS OR FUSED SWITCHES LISTED <br />FOR USE WITH THAT SWITCHGEAR SHALL <br />BE PERFORMED FOLLOWING <br />MANUFACTURERS INSTRUCTIONS OR BE <br />RE-LISTED BY A NRTL. ALL TERMINATIONS <br />OF ALUMINUM CONDUCTORS SHALL BE <br />WITH HIGH PRESS CRIMP LUGS ONLY. <br />WARNING LABEL DETAIL 1/E800 <br />2.(E) UTILITY TENANT LOAD METER. UTILITY <br />REFERENCE METER NUMBER: <br />259000-081403 <br />3.(N) PV SYSTEM UTILITY AC DISCONNECT <br />'ACDS-1'. WARNING LABEL DETAIL 1/E810 <br />4.(N) UTILITY BIDIRECTIONAL KWH METER. <br />WARNING LABEL DETAIL 1/E810 <br />5.(N) PV SYSTEM MAINTENANCE AC <br />DISCONNECT 'ACDS-2'. WARNING LABEL <br />DETAIL 2/E800 & 1/E810 <br />6.NOT USED <br />7.(N) GRID-INTERACTIVE PV INVERTER <br />LISTED TO UL 1741 WITH GROUND FAULT <br />DETECTION & INTERRUPTION. WARNING <br />LABEL DETAIL 15/E800. <br />8.NOT USED <br />9.NOT USED <br />10.FOR SUPPLY SIDE CONNECTIONS, A <br />PLAQUE SHALL BE INSTALLED AT THE <br />MAIN SERVICE DISCONNECTING DEVICE <br />AND THE PV SYSTEM UTILITY AC <br />DISCONNECT INDICATING THE LOCATION <br />OF THE RESPECTIVE SERVICE <br />DISCONNECT. WARNING LABEL DETAIL <br />1/E800 & 1/E810 <br />11.NOT USED <br />12.CONDUCTORS RUN IN PARALLEL SHALL <br />BE INSTALLED PER ART 310.4/310.10(G) <br />AND 250.122 (F). <br />13.NOT USED <br />14.NEW PULL/JUNCTION BOXES. PROVIDE <br />SERVICE LOOP IN ALL DC BRANCH <br />CONDUCTORS SOURCED FROM <br />ROOFTOPS, MIN LOOP RADIUS = 12X <br />CONDUCTOR DIAMETER. <br />15.NOT USED <br />16.(N) INVERTER INTERNAL DC DISCONNECT <br />SWITCH(ES). WARNING LABEL DETAIL <br />3/E800 <br />17.NOT USED <br />18.(N) PV MODULE LISTED TO UL 1703. <br />19.EXTRA MODULES THAT ARE UNABLE TO <br />BE PAIRED WILL HAVE THEIR OWN <br />OPTIMIZER. <br />20.(N) COMMUNICATION WIRING TO FOLLOW <br />MANUFACTURING SPECIFICATIONS. <br />21.DURING UTILITY GRID OUTAGE THE PV <br />GENERATION AND BESS WILL <br />DISCONNECT FROM THE GRID AND <br />REMAIN DISCONNECTED UNTIL GRID <br />VOLTAGE IS RESTORED TO THE <br />ACCEPTED MEASURE. <br />22.BATTERY AC OUTPUT POWER IS LIMITED <br />TO THE CORRESPONDING INVERTER OR <br />TOTAL BATTERIES CONNECTED TO A <br />SINGLE INVERTER,WHICHEVER IS LOWER. <br />23.BATTERIES SHOULD NOT BE INSTALLED IN <br />DIRECT SUNLIGHT OR LOCATIONS <br />SUBJECTED TO WATER SPRAY. <br />SPRINKLERS SHOULD BE DIVERTED <br />WHEN NECESSARY. <br />24.BATTERIES CAN COMMUNICATE <br />WIRELESSLY OR VIA RS-485 TO INVERTER. <br />BATTERIES WITHIN 150' (IDEALLY 50') OF <br />RESPECTIVE INVERTER CAN USE <br />WIRELESS COMMUNICATIONS VIA SEDG <br />HOME NETWORK CARD. <br />25.COMBINED PV AND BESS OUTPUT POWER <br />IS LIMITED TO THE INVERTER AC RATING. <br />26.NOT USED <br />816 N FIGUEROA ST BLDG A SOMAH1 <br />POI-1 DC WIRE SCHEDULE <br />TAG WIRE GAUGE CONDUCTOR <br />JACKET <br />MAX ISC 1.25 X MAX <br />CIRCUIT AMPS <br />CIRCUIT FUSE <br />RATING <br />CCC PER <br />CONDUIT <br />MAX AMBIENT <br />TEMP (C) <br />C.O.U TEMP. <br />DERATE <br />C.O.U CONDUIT <br />FILL DERATE <br />75°C AMPACITY COMPLIES WITH <br />690.8(B)(1) <br />90°C AMPACITY <br />WITH C.O.U <br />COMPLIES WITH <br />690.8(B)(2) <br />FAULT CURRENT <br />FROM PARALLEL <br />STRINGS <br />COMPLIES WITH <br />690.9(A) <br /> GROUNDING <br />PER CONDUIT <br />GROUNDING ³EMT RMC PVC 40 PVC 80 <br />DC-1.1.1 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" <br />DC-1.2.2 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" <br />DC-1.3.3 CU #8 THWN2 15 18.75 NONE 6 38 91%80%50 YES 40.0 YES 30 YES 3 CU #10 1"1"1"1 1/4" <br />DC-1.4.4 CU #10 THWN2 15 18.75 25 A 4 38 91%80%35 YES 29.1 YES 25 YES 2 CU #10 3/4"3/4"3/4"3/4" <br />POI-1 DC STRING SCHEDULE <br />STR-A STR-B STR-C <br />TAG DESTINATION CIRCUIT LENGTH ²VD%MODULE <br />WATTAGE <br />MODULE QTY OPTIMIZER MIN/MAX <br />MODULES <br />CIRCUIT LENGTH ²VD%MODULE <br />WATTAGE <br />MODULE QTY OPTIMIZER MIN/MAX <br />MODULES <br />CIRCUIT LENGTH ²VD%MODULE <br />WATTAGE <br />MODULE QTY OPTIMIZER MIN/MAX <br />MODULES <br />DC-1.1.1 INV-1.1 70 0.36%410 12 U650 8 / 16¹70 0.34%410 12 U650 8 / 16¹75 0.35%410 11 U650 8 / 16¹ <br />DC-1.2.2 INV-1.2 80 0.41%410 12 U650 8 / 16¹85 0.37%410 11 U650 8 / 16¹120 0.56%410 11 U650 8 / 16¹ <br />DC-1.3.3 INV-1.3 115 0.59%410 12 U650 8 / 16¹90 0.40%410 11 U650 8 / 16¹80 0.37%410 11 U650 8 / 16¹ <br />DC-1.4.4 INV-1.4 55 0.34%410 15 U650 10 / 19¹45 0.25%410 14 U650 10 / 19¹------------ <br />¹ MAXIMUM STRING LENGTH IS USING MANUFACTURES EXCEPTION <br />² LENGTHS ARE ESTIMATED FOR CALCULATIONS, CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS AND TAKEOFFS <br />³ WHERE EXPOSED TO PHYSICAL DAMAGE #6 TO BE USED PER NEC 250.120(C) <br />⁴ AFC VALUES ARE CALCULATED BASED ON WIRE LENGTHS. LENGTHS SHOULD REMAIN GREATER THAN OR EQUAL TO THE LENGTH LISTED IN THE TABLE. <br />##KEYED NOTES#EQUIPMENT NOTES# <br />COMMUNICATION <br />CIRCUIT IDENTIFIER <br />BATTERY OPERATION NOTE: <br />INVERTERS WITH ESS ARE CERTIFIED TO UL 1741 <br />PCS CRD AND WILL HAVE EXPORT ONLY MODES <br />ENABLED. THEY WILL UTILIZE EXCESS PV POWER <br />TO CHARGE THE BATTERIES AND THE BATTERIES <br />WILL DISCHARGE DURING SET HOURS. <br />THE PRODUCERS STORAGE DEVICE(S) WILL NOT <br />CONSUME POWER FROM THE DISTRIBUTION <br />PROVIDERS DISTRIBUTION SYSTEM AT ANY TIME <br />GRID EXPORT IS ALLOWED THROUGH NEMV METER <br />DURING UTILITY GRID OUTAGE THE PV <br />GENERATION AND BESS WILL DISCONNECT FROM <br />THE GRID AND REMAINS DISCONNECTED UNTIL <br />GRID VOLTAGE IS RESTORED TO THE ACCEPTABLE <br />MEASURE. <br />NOTE: <br />RIGID METAL CONDUIT (RMC) IS REQUIRED FOR THE NEW <br />SERVICE CONDUCTORS PRIOR TO METERING PER CITY <br />POLICY. TAPPED CONDUCTORS TO BE ROUTED IN RIGID <br />METAL CONDUIT PER CITY POLICY. <br />POI-1 AC WIRE SCHEDULE <br />LABEL DESTINATION NOMINAL VAC LINE SELECTION FLA FLAX1.25 OCPD PHASE <br />CONDUCTOR <br />NEUTRAL <br />CONDUCTOR <br />GROUNDING <br />CONDUCTOR <br />CONDUCTORS PER <br />PHASE <br />CONDUIT QTY 75°C AMPS 90°C AMPS 90°C AMPS W/ <br />C.O.U <br />C.O.U TEMP <br />DERATE <br />C.O.U CONDUIT <br />FILL <br />CIRCUIT LENGTH ²SEGMENT VD%DC/AC RATIO AFC START AFC END ⁴EMT RMC PVC 40 PVC 80 <br />INV-1.1 LC-1.1 208 A-B 48.1 60.1 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%5 0.11%143.5%12,049 9,726 3/4"3/4"3/4"3/4" <br />INV-1.2 LC-1.1 208 B-C 48.1 60.1 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%5 0.11%139.4%12,049 9,726 3/4"3/4"3/4"3/4" <br />INV-1.3 LC-1.1 208 C-A 48.1 60.1 60 CU #6 CU #10 CU #10 1 1 65 75 68.3 91%100%5 0.11%139.4%12,049 9,726 3/4"3/4"3/4"3/4" <br />INV-1.4 LC-1.1 208 A-B-C 27.8 34.8 35 CU #8 CU #10 CU #10 1 1 50 55 50.1 91%100%5 0.09%118.9%12,049 8,782 3/4"3/4"3/4"3/4" <br />LC-1.1 AC-1.2 208 A-B-C 111.0 138.8 150 CU #1/0 CU #6 CU #6 1 1 150 170 154.7 91%100%35 0.37%--22,080 12,049 1 1/2"1 1/4"1 1/2"1 1/2" <br />AC-1.2 AC-1.1 208 A-B-C 111.0 138.8 150 CU #1/0 CU #6 CU #6 1 1 150 170 154.7 91%100%5 0.05%--25,061 22,080 NA 1 1/4"NA NA <br />AC-1.1 POI-1.1 208 A-B-C 111.0 138.8 150 CU #2/0 CU #2/0 CU #4 1 1 175 195 142.0 91%80%18 0.16%--42,000 25,061 NA 2"NA NA <br />C:\USERS\JEFFREY.ABROMOWITZ\DOCUMENTS\WORKING PROJECTS\ANDALUCIA\WORKING DESIGN DOCS_V0\FINULENT\8-25\CAD FILES\CAD\ANDALUCIA_PVPLANS_V0.DWG <br />POI-1 ONE LINE <br />CONTRACTOR: <br />ENGINEERING APPROVAL: <br />600 CALIFORNIA ST #1800, SAN <br />FRANCISCO, CA 94104 <br />CA CL #750184 <br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN <br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT <br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. <br />ANDALUCIA <br />816 N FIGUEROA ST, SANTA <br />ANA, CA 92703, USA <br />APN:198-162-03, 198-162-44, <br />198-162-52 <br />DEVELOPER: <br />C&C DEVELOPMENT <br />DESCRIPTION DATE REV <br />0ORIGINAL08/26/25 <br />PROJECT DETAILS: <br />PV SYSTEM: <br />·220.17 kW DC <br />·167.3 kW AC <br />·203.365 CEC AC <br />ENERGY STORAGE: <br />·120 kW AC <br />·349.2 kWH <br />E600 <br />SHEET SIZE: <br />REVISION: <br />SHEET TITLE: <br />36" X 24" (ARCH D) <br />DESIGNER: FINS_AP <br />ORIGINAL <br />CONTRACT NUMBER: <br />3003200669 <br />PJT #: PROP-001216