SNAPNRACK ULTRA RAIL TILE ROOF HOOK WS FOR MOUNTING TO W AND S
<br />PROFILE TILE ROOFS
<br />SNAPNRACK ULTRA RAIL
<br />TILE ROOF HOOK WS
<br />S-TILES, TYP.
<br />REFER TO SNAPNRACK ENGINEERING CHARTS FOR APPLICABLE RAIL SPANS.
<br />"BIN" NUMBER ON CHART SHOULD MATCH "BIN" NUMBER ON THIS
<br />DRAWING
<br />MODULE HEIGHT OFF ROOF:
<br />BIN:
<br />7
<br />ROOF SHEATHING, TYP.
<br />SNAPNRACK
<br />ULTRA RAIL
<br />RAFTER OR OTHER STRUCTURAL
<br />ROOF MEMBER, TYP.
<br />TILE BATTEN, TYP.PENETRATION DETAIL
<br />SNAPNRACK
<br />ULTRA RAIL
<br />ROOF SEALANT
<br />SNAPNRACK ULTRA
<br />RAIL MOUNTING
<br />HARDWARE, TYP.
<br />SNAPNRACK ULTRA RAIL
<br />TILE ROOF HOOK WS
<br />STEP 1:
<br />REMOVE TILES TO EXPOSE
<br />ROOF DECKING S-TILES, TYP.
<br />SNAPNRACK ULTRA RAIL
<br />TILE ROOF HOOK WS
<br />ROOF SHEATHING, TYP.
<br />STEP 2:
<br />DRILL 2 QTY. 3/16"Ø PILOT HOLES
<br />INTO
<br />HOOK CAN BE OFFSET FROM
<br />RAFTER UP TO 4" IN EITHER
<br />DIRECTION TO LINE UP WITH
<br />LOW POINT IN S-TILESRAFTER. SEAL ROOF PENETRATIONS
<br />WITH APPROPRIATE SEALANT.
<br />FASTEN BASE TO ROOF WITH 2 QTY.RAFTER OR OTHER STRUCTURAL
<br />ROOF MEMBER, TYP.5/16"Ø LAG SCREWS WITH FLAT WASHERS.
<br />WITH S.S. FLAT WASHERS
<br />5/16"Ø S.S. LAG SCREW MUST EMBED A MIN. OF 2-1/2"
<br />INTO STRUCTURAL MEMBER
<br />5/16"Ø HARDWARE TORQUE SPECIFICATIONS
<br />REFER TO SNAPNRACK INSTALLATION MANUAL FOR
<br />RAILS CAN MOUNT TO EITHER SIDE OF TILE HOOK
<br />(UPSLOPE VS. DOWNSLOPE)
<br />RAILS CAN BE LEVELED UP TO 1-1/4" USING THE SLOT IN
<br />THE TILE HOOK.
<br />UR-40: 6-5/8" TO 7-7/8"
<br />UR-60: 7-1/4" TO 8-1/2"
<br />2-1/2" MIN EMBEDMENT
<br />INTO WOOD RAFTER, TYP.
<br />5/16"Ø S.S. LAG SCREWS WITH
<br />C ULTRA RAIL, TILE ROOF HOOK WS (TYP.)
<br />NTS
<br />UR-40 RAIL | UR-45 RAIL | UR-60 RAIL
<br />FOR USE WITH SNAPNRACK ULTRA SERIES RAILS
<br />2 1 4"
<br />1 1 2"
<br />1 1 2"
<br />1 5 8"1 3
<br />4 "
<br />1 1 2"
<br />2 QTY 5/16"Ø S.S. LAG SCREWS
<br />WITHS.S FLAT WASHERS
<br />B REDUCED SPACING AND OVERHANG DETAIL
<br />NTS
<br />NOTE: IF ARRAY (EXCLUDING SKIRT) IS
<br />WITHIN 12" BOUNDARY REGION OF ANY
<br />ROOF PLANE EDGES (EXCEPT VALLEYS),
<br />THEN ATTACHMENTS NEED TO BE ADDED
<br />AND OVERHANG REDUCED WITHIN THE
<br />12" BOUNDARY REGION ONLY AS
<br />FOLLOWS:
<br />·ALLOWABLE ATTACHMENT SPACING
<br />INDICATED ON PLANS TO BE
<br />REDUCED BY 50% (REFER TO TABLE
<br />ABOVE)
<br />·ALLOWABLE OVERHANG INDICATED
<br />ON PLANS TO BE 1/5TH OF
<br />ALLOWABLE ATTACHMENT SPACING
<br />INDICATED ON PLANS (REFER TO
<br />TABLE ABOVE)
<br />12" BOUNDARY
<br />12" SETBACK DOES
<br />NOT APPLY TO
<br />VALLEYS
<br />48" BOUNDARY
<br />·ALLOWABLE ATTACHMENT
<br />SPACING INDICATED ON PLANS
<br />TO BE REDUCED BY 50% (REFER
<br />TO TABLE ABOVE)
<br />·ALLOWABLE OVERHANG
<br />INDICATED ON PLANS TO BE
<br />1/5TH OF ALLOWABLE
<br />ATTACHMENT SPACING
<br />INDICATED ON PLANS (REFER TO
<br />TABLE ABOVE)
<br />PITCHED/SLOPED ROOFS - REDUCED SPACING AND OVERHANG DETAIL FOR
<br />12" BOUNDARY REGION
<br />FLAT ROOFS - REDUCED SPACING AND OVERHANG DETAIL FOR 48"
<br />BOUNDARY REGION
<br />D ULTRA RAIL MID CLAMP
<br />NTS
<br />1.
<br />4
<br />1
<br />1.57
<br />1.29
<br />1.
<br />3
<br />3
<br />.9
<br />4
<br />1
<br />1.75
<br />.1
<br />9
<br />.33
<br />1.
<br />4
<br />8
<br />.57
<br />SNAPNRACK ULTRA END CLAMP,
<br />FITS 30MM - 46MM MODULE HEIGHTS
<br />"RAIL END OVERHANG"
<br />DISTANCE FROM RAIL END
<br />TO OUTER ROOF ATTACHMENT CENTER.
<br />NOT TO EXCEED 34% OF ALLOWABLE SPAN
<br />STRUCTURAL MEMBER
<br />"RAIL SPAN" DISTANCE BETWEEN
<br />CENTERS OF TWO ROOF ATTACHMENTS
<br />DETAIL A:
<br />SNAPNRACK, ULTRA RAIL END CLAMP
<br />BA
<br />SNAPNRACK ULTRA MID CLAMP,
<br />FITS 30MM - 46MM MODULE HEIGHTS
<br />SNAPNRACK, ULTRA RAIL
<br />PV MODULE, TYP.
<br />SNAPNRACK, ULTRA RAIL
<br />DETAIL B:
<br />SNAPNRACK, ULTRA RAIL MID CLAMP
<br />DETAIL C:
<br />PV MODULE FRAME, TYP.
<br />SNAPNRACK, UNIVERSAL END CLAMP.
<br />MODULE HEIGHT AGNOSTIC AND
<br />HIDDEN BENEATH MODULES
<br />SNAPNRACK, ULTRA RAIL
<br />SNAPNRACK, UNIVERSAL END CLAMP
<br />C
<br />PV MODULE, TYP.
<br />3 4" MODULE SPACING
<br />PV MODULE, TYP.
<br />SNAPNRACK, ULTRA RAIL
<br />OVERVIEW OF THE SNAPNRACK ULTRA RAIL
<br />SYSTEM INSTALLED ON A TYPICAL ROOF
<br />REFER TO SPECIFIC "ATTACHMENT DETAIL"
<br />FOR DETAILS ON ATTACHING AND
<br />WATERPROOFING THE VARIOUS
<br />SNAPNRACK ROOF ATTACHMENT PRODUCTS
<br />REFER TO SPECIFIC "COMPONENT DETAIL"
<br />FOR DETAILS ON VARIOUS SNAPNRACK
<br />ACCESSARY AND COMPONENT PRODUCTS
<br />BOTH THE SNAPNRACK, UNIVERSAL END
<br />CLAMP AND SNAPNRACK, ADJUSTABLE END
<br />CLAMP CAN BE USED ON END MODULES
<br />MODULES MAY BE CLAMPED ON SHORT OR
<br />LONG SIDE PER MODULE MANUFACTURER
<br />REQUIREMENTS
<br />RAILS MAY BE MOUNTED UP/DOWN OR
<br />ACROSS THE SLOPE OF THE ROOF
<br />REFER TO SNAPNRACK INSTALLATION
<br />SPECIFICATIONS
<br />SNAPNRACK, ADJUSTABLE
<br />END CLAMP. SELECT TO
<br />MATCH MODULE HEIGHT
<br />PV MODULE, TYP.
<br />MANUAL FOR 5/16" Ø HARDWARE TORQUE
<br />SNAPNRACK, MID CLAMP.
<br />SELECT TO MATCH MODULE HEIGHT
<br />"MODULE OVERHANG"
<br />SNAPNRACK, ULTRA RAIL DISTANCE FROM RAIL SIDE TO MODULE EDGE.
<br />NOT TO EXCEED 25% OF MODULE LENGTH OR
<br />MODULE MANUFACTURER RECOMMENDATIONS
<br />SNAPNRACK, ULTRA RAIL
<br />END CAP, OPTIONAL
<br />ROOFING MATERIAL,
<br />COMP SHINGLE SHOWN, TYP.
<br />ROOF SHEATHING AND
<br />UNDERLAYMENT MATERIAL, TYP.
<br />STRUCTURAL MEMBER,
<br />WOODEN RAFTER SHOWN, TYP.
<br />SNAPNRACK ROOF ATTACHMENT, VAIRES WITH
<br />ROOF TYPE. REFER TO SPECIFIC "ATTACHMENT DETAIL"
<br />FOR ATTACHMENT & WATERPROOFING DETAILS
<br />BIN:
<br />ALL
<br />A ULTRA RAIL, SYSTEM OVERVIEW ULTRA MIDS & ENDS
<br />NTS
<br />UR-40 RAIL | UR-45 RAIL | UR-60 RAIL
<br />FOR USE WITH SNAPNRACK ULTRA SERIES RAILS
<br />2 1 4"
<br />1 1 2"
<br />1 1 2"
<br />1 5 8"1 3
<br />4 "
<br />1 1 2"
<br />.60 1.50
<br />1.56 .29
<br />35°
<br />54°.96
<br />.90
<br />FLANGE LENGTH
<br />(FLAT SURFACE)
<br />.39 - 1.21
<br />[10.0 - 30.7]
<br />FLANGE THICKNESS
<br />.05 - .10
<br />[1.2 - 2.5]
<br />MIN BOX WIDTH
<br />.22
<br />[5.5]
<br />MODULE FRAME GEOMETRY REQUIREMENTS
<br />.85
<br />E ULTRA RAIL UNIVERSAL END CLAMP
<br />NTS
<br />C:\USERS\JEFFREY.ABROMOWITZ\DOCUMENTS\WORKING PROJECTS\PROJECTS - ON HOLD\ANDALUCIA\WORKING DESIGN DOCS_V0\FINULENT\8-25\CAD FILES\CAD\ANDALUCIA_PVPLANS_V0.DWG
<br />RACKING ATTACHMENT
<br />DETAILS
<br />CONTRACTOR:
<br />ENGINEERING APPROVAL:
<br />600 CALIFORNIA ST #1800, SAN
<br />FRANCISCO, CA 94104
<br />CA CL #750184
<br />UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN
<br />PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT
<br />LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS.
<br />ANDALUCIA
<br />816 N FIGUEROA ST, SANTA
<br />ANA, CA 92703, USA
<br />APN:198-162-03, 198-162-44,
<br />198-162-52
<br />DEVELOPER:
<br />C&C DEVELOPMENT
<br />DESCRIPTION DATE REV
<br />0ORIGINAL08/26/25
<br />PROJECT DETAILS:
<br />PV SYSTEM:
<br />·220.17 kW DC
<br />·167.3 kW AC
<br />·203.365 CEC AC
<br />ENERGY STORAGE:
<br />·120 kW AC
<br />·349.2 kWH
<br />S400
<br />SHEET SIZE:
<br />REVISION:
<br />SHEET TITLE:
<br />36" X 24" (ARCH D)
<br />DESIGNER: FINS_AP
<br />ORIGINAL
<br />CONTRACT NUMBER:
<br />3003200669
<br />PJT #: PROP-001216
|