Laserfiche WebLink
DW <br />REF <br />(GAS) <br />G GGGGG <br />CW <br />CW <br />CW <br />SSSSSSSS <br />CWCWCWCW <br />CW <br />CW <br />CW <br />CW <br />CW CWCWCW CW <br />CW <br />S <br />S <br />CW <br />CW <br />CW CWCW <br />CW <br />CW <br />CW <br />G <br />G <br />G GGGGGGGG G <br />G <br />G <br />G <br />G <br />G <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />S <br />SSSSSSSSS <br />S <br />SG <br />G <br />G <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />4 <br />8 <br />. <br />0 <br />0 <br />' <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br /> <br /> <br />4 <br />8 <br />. <br />0 <br />0 <br />' <br />PROPERTY LINE 127.50' <br />PROPERTY LINE 127.50' <br />2 <br />18 <br />317 N MAXINE ST. <br />(E) MAIN HOUSE <br /> 1,012 SF <br />16 <br />2 <br />(E) HOUSE <br />ENTRY <br />(E) KITCHEN <br />(E) LIVING <br />(E) BATH 1 <br />(E) GARAGE <br /> 415 SF <br />SI <br />D <br />E <br />W <br />A <br />L <br />K <br />RO <br />A <br />D <br /> <br />V <br />E <br />R <br />G <br />E <br />(E) BED 3 <br />(E) BATH 2 <br />(E) HALLWAY <br />(E) LAUNDRY <br />(E) BED 1 <br />(E) BED 2 <br />(E) CLOSET <br />(E) DINING <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br />7 <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br />4 <br />(E) CLOSET <br />13 <br />5' <br /> <br />T <br />A <br />L <br />L <br /> <br />B <br />L <br />O <br />C <br />K <br /> <br />W <br />A <br />L <br />L <br />FO <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />20 <br />(E) WATER METTER <br />MAXINE ST <br />(E <br />) <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />SIDEWALK <br />ROAD VERGE <br />19 <br />5' TALL BLOCK WALL <br />LINE OF CURB <br />21 21 <br />8' <br />- <br />0 <br />" <br /> <br />4 <br />' <br />- <br />0 <br />" <br /> <br />4 <br />8 <br />' <br />- <br />0 <br />" <br />8' <br />- <br />0 <br />" <br /> <br />4 <br />' <br />- <br />0 <br />" <br /> <br />1 <br />1 <br />' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />2 <br />5 <br />' <br />- <br />1 <br />1 <br />" <br /> <br />1 <br />1 <br />' <br />- <br />0 <br />" <br />60 <br />' <br />- <br />0 <br />" <br />18'-0" 61'-0" 48'-6" <br />(E) ELEC <br />METER <br />(E) 5' TALL BLOCK WALL TO BE DEMO'D <br />ATTACHED PATIO COVER TO BE REMOVED <br />127'-6" <br />3'-0" 15'-9" 3'-0" 47'-0 1/2" <br />(E) DRIVEWAY <br />APPROACH <br />(E) DRIVEWAY <br />(E) W/H <br />DEMO <br />UNPERMITTED <br />ROOM <br />36'-0" <br />24'-0" 12'-0" <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br />PL <br />. <br /> <br />4 <br />8 <br />. <br />0 <br />0 <br />' <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br /> <br /> <br />4 <br />8 <br />. <br />0 <br />0 <br />' <br />PROPERTY LINE 127.50' <br />PROPERTY LINE 127.50' <br />2 <br />18 <br />317 N MAXINE ST. <br />(E) MAIN HOUSE <br /> 1,012 SF <br />16 <br />2 <br />(E) HOUSE <br />ENTRY <br />(E) KITCHEN <br />(E) LIVING <br />(E) BATH 1 <br />(E) GARAGE <br /> 415 SF <br />SI <br />D <br />E <br />W <br />A <br />L <br />K <br />RO <br />A <br />D <br /> <br />V <br />E <br />R <br />G <br />E <br />(E) BED 3 <br />(E) BATH 2 <br />(E) HALLWAY <br />(E) LAUNDRY <br />(E) BED 1 <br />(E) BED 2 <br />(E) CLOSET <br />(E) DINING <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br />7 <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br />4 <br />(E) CLOSET <br />5' <br /> <br />T <br />A <br />L <br />L <br /> <br />B <br />L <br />O <br />C <br />K <br /> <br />W <br />A <br />L <br />L <br />FO <br />U <br />R <br />T <br />H <br /> <br />S <br />T <br />20 <br />(E) WATER METTER <br />MAXINE ST <br />(E <br />) <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />SIDEWALK <br />ROAD VERGE <br />19 <br />5' TALL BLOCK WALL <br />LINE OF CURB <br />21 21 <br />8'-0" 4'-0" 18'-0" 61'-0" 6'-0" 35'-9 1/2" <br />SET BACK <br />6'-9" <br />23 <br />(E) WATER METTER <br />(E) SEWER <br />LATERAL <br />V.I.F. <br />* <br />15 <br />WATER <br />P.O.C <br />SEWER <br />P.O.C <br />(N) BED 1(N) BED 2 <br />(N) BATH 1 <br />(N) LIVING <br />(N <br />) <br /> <br /> <br />K <br />I <br />T <br />C <br />H <br />E <br />N <br />(N) BATH 2 <br />(N) W/H <br />(N) CLOSET <br />(N) DINING <br />(N <br />) <br /> <br />4 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br />(N <br />) <br /> <br />4 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br />(N) GARAGE <br />12 <br />(N) 4:12 <br />SLOPE <br />(N) 4:12 <br />SLOPE <br />8' <br />- <br />0 <br />" <br /> <br />4 <br />' <br />- <br />0 <br />" <br /> <br />6 <br />' <br />- <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />3 <br />7 <br />' <br />- <br />0 <br />" <br />SET BACK <br />5' <br />- <br />0 <br />" <br />BEGIN CONSTRUCTION <br />MEASUREMENT AT THIS CORNER <br />SCE <br />MSR# <br />1.11 14 <br />60 <br />' <br />- <br />0 <br />" <br />17 <br />10 <br />5 <br />6 <br />GAS <br />P.O.C* <br />* <br />* <br />(E) DRIVEWAY <br />4.1 <br />(N) DRIVEWAY <br />ENLARGED <br />ENLARGED DRIVEWAY APPROACH <br />PER CITY OF SANTA ANA. <br />THE APPLICANT IS REQUIRED TO <br />OBTAIN A SEPARATE STREET <br />ENCROACHMENT PERMIT. <br />(E) DRIVEWAY <br />APPROACH <br />315 N MAXINE ST. <br />(N) ADU <br />799 SF <br />5% SLOPE <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br />5% SLOPE <br />5% SLOPE <br />5% SLOPE <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br />5% <br /> <br />S <br />L <br />O <br />P <br />E <br />5% SLOPE <br />eave <br />1'-0" <br />ea <br />v <br />e <br />1' <br />- <br />0 <br />" <br />eave <br />1'-0" <br />ea <br />v <br />e <br />1' <br />- <br />0 <br />" <br />eave <br />1'-0" <br />ea <br />v <br />e <br />1' <br />- <br />6 <br />" <br />eave <br />1'-0" <br />3'-0" 15'-9" 20'-0 1/2" 3'-0" 27'-0" <br />281 SF <br />(N) ADU ENTRY <br />PORCH 65 SF <br />(N) LAUNDRY <br />(E) W/H <br />WALKWAY <br />6'-0" <br />(N) <br />LANDSCAPING <br />(N) WALKWAY <br />FRONT YARD FENCE TO BE LEAGALIZED <br />ON SEPARATE PERMIT <br />UNDER RES-2023-2140-SCND <br />36'-0" <br />24'-0" 12'-0" <br />13.1 <br />13.1 <br />1 <br />A.07 <br />2.1 <br />2.1 <br />2.2 <br />2.2 <br />2.2 <br />1 <br />1 <br />1 <br />1 1 <br />1 <br />1 <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br />(E <br />) <br /> <br />4 <br />: <br />1 <br />2 <br /> <br />SL <br />O <br />P <br />E <br />15.11 <br />8FT MIN. <br />9'-0" <br />8FT MIN. <br />9'-0" <br />8FT MIN. <br />9'-0" <br />8FT MIN. <br />9'-0" <br />8FT MIN. <br />9'-0" <br />8F <br />T <br /> <br />M <br />I <br />N <br />. <br />11 <br />' <br />- <br />9 <br />" <br />1 <br />1 <br />' <br />- <br />9 <br />" <br />8F <br />T <br /> <br />M <br />I <br />N <br />. <br />11 <br />' <br />- <br />9 <br />" <br />8F <br />T <br /> <br />M <br />I <br />N <br />. <br />11 <br />' <br />- <br />9 <br />" <br />8F <br />T <br /> <br />M <br />I <br />N <br />. <br />12 <br />' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />8FT MIN. <br />9'-0" <br />8FT MIN. <br />9'-0" <br />MIN. <br />8'-0" <br />1 <br />1 <br />1 <br />1 <br />TY <br />P <br />. <br />12 <br />" <br /> <br />13.1 <br />NOTE:MAXIMUM FENCE HEIGHT SHALL BE 3'-0" IN FRONT YARD AREAS <br />AND 2'-6" WITHIN CORNER SIGHT TRIANGLES, PER CITY REQUIREMENTS. <br />PROJECT CONTACT <br />OWNERSHIP <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING <br />CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING <br />OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS <br />AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY <br />KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF <br />CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS <br />SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO <br />THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE <br />OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN <br />CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />1 05/14/2025 1ST PLANCHECK <br />A.01 <br />TITLE SHEET / <br />SITE PLANS / <br />ROOF PLANS <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />31 <br />5 <br /> <br />N <br /> <br />M <br />A <br />X <br />I <br />N <br />E <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />M <br />A <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br />31 <br />7 <br /> <br />N <br /> <br />M <br />A <br />X <br />I <br />N <br />E <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />DETACHED ADU: <br />2 BEDROOMS, <br />2 BATHROOMS, <br />LIVING, KITCHEN, <br />DINING, LAUNDRY, <br />AND ATTACHED <br />1-CAR GARAGE <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />THE PROPOSED PROJECT IS A 799 SF ONE-STORY DETACHED <br />ACCESSORY DWELLING UNIT, 2 BEDROOMS, 2 BATHROOMS, <br />LIVING, KITCHEN, DINING, LAUNDRY, AND 65 SF ENTRY PORCH. <br />DEMOLISHING THE PATIO COVER AND ACCESSORY STRUCTURE, <br />AND REPLACING HARDSCAPE WITH LANDSCAPE IN THE REAR <br />YARD. <br />DEMOLITION OF BLOCK WALL AND EXPANSION OF CURB CUT. <br />LEGALIZE FRONT YARD FENCE ON SEPARATE PERMIT <br />UNDER RES-2023-2140-SCND <br />SHEET INDEX <br />SCOPE OF WORK <br />VICINITY MAP PROJECT DATAGENERAL NOTESSITE PLAN NOTES <br />1. DEMOLITION CONTRACTOR SHALL RELOCATE REUSABLE MATERIALS TO DESIGNATED <br />SALVAGE AREA, NON-USABLE MATERIALS SHALL BE PLACED APPROPRIATELY IN REFUSE <br />BIN AND SHALL BE COVERED AT NIGHT AND DURING RELATIVE HIGH WINDS, RAIN, <br />ETC...REFUSE BIN SHALL BE COVERED DURING TRANSFER TO AND FROM DUMP SITE. <br />CONTRACTOR TO BE LIABLE FOR REFUSE SPILLING. ALL DEBRIS TO BE HAULED AWAY <br />AND CLEAN-UP SHALL BE COMPLETED TO BROOM FINISH. EXISTING MATERIALS AND/OR <br />STRUCTURE TO REMAIN SHALL BE PROTECTED FROM DUST, PAINT CHIPPING, ETC..., BY <br />USE OF PLASTIC OR WHATEVER IS REQUIRED FOR PROPER PROTECTION. EXISTING <br />STRUCTURES SHALL HAVE BRACING AND SHORING AS REQUIRED TO PROTECT THE <br />EXISTING STRUCTURE. PROVIDE DE-WATERING FACILITIES FOR CONSTRUCTION AS <br />REQUIRED. COORDINATE AS-BUILT INFORMATION, STRUCTURAL, ETC. TO <br />DESIGNER/ENGINEER AS REQUIRED. <br />2. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. <br />NO SOID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE <br />MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY <br />CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE <br />STREET, GUTTER OR STORM DRAIN SYSTEM. <br />3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOTCLEAR AND UNOBSTRUCTED <br />ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL- <br />BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR <br />TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN <br />FEET OF ANY POWER LINES - WHETHER OR NOT THE LINES ARE LOCATED ON THE <br />PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR <br />ADDITIONAL EXPENSES. <br />4. WHEN UTILITIES METER ALTERATION / RELOCATION OCCUR, INSTALLATION <br />PROCEDURES SHALL BE VERIFIED AND APPROVED BY THE BUILDING INSPECTOR PRIOR <br />TO INSTALLATION. <br />5. NOTIFY AQMD FOR ASBESTOS REMOVAL PROCEDURE AND SUBMIT ASBESTOS REPORT <br />TO BUILDING DIVISION PRIOR TO DEMOLITION PERMIT ISSUANCE. <br />1) THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY <br />WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, <br />VALVES, METERS, ETC) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN <br />TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO <br />COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/ OR ADDITIONAL EXPENSES. <br />2) AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN <br />STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR <br />STRUCTURE CONTAINING THE FUEL GAS PIPING. <br />3) PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS <br />AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. <br />4) PROVIDE 72" HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT <br />MATERIALS FOR SHOWER ENCLOSURE. <br />5) ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZED AT ALL TIMES <br />7) FINAL APPROVAL REQUIRED BY THE PUBLIC WORKS DEPARTMENT FOR STREET IMPROVEMENTS, CURB <br />CORES, CURB/GUTTERS, ETC. SEPARATE PUBLIC WORKS PERMIT REQUIRED FOR DRIVEWAYS, APPROACH TO <br />DRIVEWAY, SEWER LATERALS AND ANY WORK IN RIGHT OF WAY. <br />8) ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND <br />AMENDMENTS. <br />9) A SURVEY SHALL BE PROVIDED BY A LICENSED SURVEYOR ON STRUCTURES WHICH DEFINE PROPERTY <br />LINES, SET BACKS, DESIGNATED PARKLAND OR STREET RIGHT-OF-WAY. <br />10) DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT. <br />11) WATER HEATER MUST BE STRAPPED TO WALL; SEE DETAIL ON SHEET A-07. <br />12) PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND <br />TOILETS MUST BE ADAPTED FOR WATER CONSUMPTION. <br />13) LAG BOLTS: PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL DIA. FOR SMOOTH SHANK <br />PORTION. 91 NDS <br />14) BLOCKING. ROOF RAFTERS AND CEILING JOINTS SHALL BE SUPPORTED LATERALLY TO PREVENT <br />ROTATION & LATERAL DISPLACEMENT IN ACCORDANCE w/ THE PROVISIONS OF CH.8 & CH.6 <br />15) CONTRACTOR AND/OR OWNER SHALL VERIFY CONSTRUCTION SITE TO CONFIRM THAT THERE IS NO TRACE <br />OF DEMOLISHED SWIMMING POOL WITHIN 5 FT FROM PROPOSED PERIMETER OF THE CONSTRUCTION SITE. <br />OTHERWISE, THEY NEED TO SUBMIT SOIL COMPACTION REPORT FROM LICENSED SOIL ENGINEER TO <br />BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. <br />17) SHEAR WALLS, LATHING & PLASTER IN MATERIALS SHALL CONFORM TO THE STANDARDS LISTED IN CH.6 & <br />CH.7 CRC <br />18) ALL BOLT HOLES SHALL BE DRILLED 1/32 TO 1/16" OVERSIZED." ENGINEER MUST INCLUDE IN STRUCTURAL <br />OBSERVATION NOTES. <br />19) PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. <br />21) CONCRETE 3000 PSI <br />22) PARALLEL BEAM E.2.0 PSL <br />23) UFER GROUND IS REQUIRED AT NEW ELECTRICAL SERVICE. <br />24) UNDERGROUND UTILITIES REQUIRED ON SITE PLAN AND SHOW FOR ELECTRICAL, CABLE TV. AND <br />TELEPHONE <br />25) ARC FAULT CIRCUIT INTERRUPTION PROTECTION IS REQUIRED FOR ALL BRANCH CIRCUITS PER 2022 <br />CRC210.12 SHALL BE AFCI PROTECTED <br />26) BATHROOMS, KITCHEN, GARAGE & OUTSIDE OUTLETS WILL BE GFCI PROTECTED RECEPTACLE OUTLETS. <br />27) WATER SAVING WATER CLOSET w/ 1.28 GALLONS PER FLUSH. <br />28) PROVIDE MECHANICAL VENTILATION FOR BATHROOMS AND LAUNDRY ROOMS WITHOUT OPENABLE <br />WINDOW. <br />29) GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24 INCH ARC OF A DOORWAY'S <br />VERTICAL EDGE MUST COMPLY WITH CH. 3 CRC <br />30) LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR <br />THE DOOR, WHICHEVER IS GREATER. <br />31) EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT IN <br />ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE AN AVERAGE ILLUMINATION OF 6 FEET-CADLES <br />OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE FLOOR LEVEL. <br />32) THE CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS, SURVEY <br />THE PROPERTY AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND SCOPE OF WORK. ALL COST <br />SUBMITTED SHALL BE BASED ON A THROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY <br />DISCREPANCY AND/OR UNCERTAINTY AS TO WHAT MATERIALS OR PRODUCT IS TO BE USED SHOULD BE <br />VERIFIED WITH THE OWNER OR ENGINEER OF RECORD. <br />33) DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE. <br />34) IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE OWNER AND THE <br />DESIGNERS/ENGINEERS SHALL BE NOTIFIED, IN WRITING, IMMEDIATELY. <br />35) THE APPLICANT/PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY <br />EASEMENTS AND/OR CLEARANCES ON-SITE THAT MAY AFFECT THE PROJECT. <br />PARKING REQUIREMENTS <br />NOTWITHSTANDING ANY OTHER LAW, A LOCAL AGENCY, WHETHER OR NOT IT HAS <br />ADOPTED AN ORDINANCE GOVERNING ACCESSORY DWELLING UNITS IN ACCORDANCE <br />WITH SUBDIVISION, SHALL NOT IMPOSE PARKING STANDARDS FOR AN ACCESSORY <br />DWELLING UNIT IN ANY OF THE FOLLOWING INSTANCES: <br />THE ACCESSORY DWELLING UNIT IS LOCATED WITHIN ONE-HALF MILE WALKING <br />DISTANCE OF PUBLIC TRANSIT. <br />LEGAL DESCRIPTION <br />ASSESSORS PARCEL NO. APN: <br />LEGAL DESCRIPTION: <br />FLOOD ZONE A <br />LOT SIZE 6,120 SF <br />ZONE R-1 RESIDENTIAL <br />EXISTING GARAGE 415 SF <br />EXISTING LIVING 1,012 SF <br />EXISTING PATIO COVER 346 SF ( TO BE DEMOLISHED ) <br />NEW ADU ENTRY PORCH 65 SF <br />NEW GARAGE 281 SF <br />NEW ADU 799 SF <br />TOTAL 2,572 SF <br />EXISTING: 1,012 SF LIVING + 415 SF GARAGE = 1,427 SF <br />NEW: 799 SF ADU + 65 PORCH ADU + 281 SF GARAGE = 1,145 SF <br />LOT COVERAGE = (2,572-799) SF / 6,120 SF = 29% <br />(ADU EXCEMPT FOR LOT COVERAGE WHEN LESS THAN 800 SF) <br />OCCUPANCY GROUP R3 / U <br />CONSTRUCTION TYPE V-B <br />FIRE SPRINKLER MAIN HOUSE = NO; ADU = NO <br />NUMBER OF STORIES MAIN HOUSE = 1; ADU = 1 <br />REAR OPEN SPACE:EXEMPT FOR ADU <800 SF <br />CALIFORNIA DEPARTMENT OF HOUSING <br />AND COMMUNITY DEVELOPMENT <br />THE CALIFORNIA DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT ISSUED AN <br />ACCESSORY DWELLING UNIT HANDBOOK WITH UPDATES AND LAWS EFFECTIVE JANUARY <br />1, 2021(HTTPS://WWW.HCD.CA.GOV/POLICY-RESEARCH/DOCS/ADU_DECEMBER_2020 <br />_HANDBOOK.PDF) <br />"STATE ADU LAW DOES NOT ALLOW FOR THE LIMITATION ON THE NUMBER OF <br />BEDROOMS OF AN ADU. A LIMIT ON THE NUMBER OF BEDROOMS COULD BE CONSTRUED <br />AS A DISCRIMINATORY PRACTICE TOWARDS PROTECTED CLASSES, SUCH AS FAMILIAL <br />STATUS, AND WOULD BE CONSIDERED A CONSTRAINT ON THE DEVELOPMENT OF ADUS." <br />1" = 10'-0"1EXISTING SITE PLAN / ROOF PLAN <br />1" = 10'-0"2PROPOSED SITE PLAN / ROOF PLAN <br />SCALE : 1" = 10'-0" <br />0 10'20' <br />APPLICABLE CODES <br />SITE PLAN KEYNOTES <br />STRUCTURE MATERIALS: <br />EXTERIOR WALLS -WHITE STUCCO <br />ROOF -GREY SHINGLES <br />NOTE: <br />ALL PLANT MATERIALS SELECTED FROM LA <br />COASTAL GARDENS AND WWW.BEWATERWISE.COM <br />ARE ACCEPTABLE DROUGHT TOLERANT PLANTS. <br />PROJECT DIRECTORY <br />OWNERSHIP: <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />DESIGNER: <br />BB BROTHERS CORP. <br />949 SOUTH COAST DR., SUITE 570 <br />COSTA MESA, CA 92626 <br />949-836-5768 <br />STRUCTURAL ENGINEER: <br />AMIR DEIHIMI <br />949 SOUTH COAST DR., SUITE 570 <br />COSTA MESA, CA 92626 <br />949-836-5768 <br />SOIL ENGINEER: <br />PRIORITY ENGINEERING GROUP <br />335 E. BLUERIDGE AVE. <br />ORANGE, CA 92865 <br />TITLE 24: <br />SANG LUU <br />949 SOUTH COAST DR., SUITE 570 <br />COSTA MESA, CA 92626 <br />949-836-5768 <br />DIG ALERT (811) IS TO BE CONTACTED AND THAT <br />COMPLIANCE WITH EXCAVATION SAFETY IN ACCORDANCE <br />WITH GOVERNMENT CODE 4216 WILL BE FOLLOWED PRIOR <br />TO ANY EXCAVATION TAKING PLACE. <br />OWNER / CONTRACTOR ACKNOLEDGEMENT SIGNATURE: <br />____________________________________________________ <br />DIG ALERT 811 <br />LANDSCAPE LEGEND <br />THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES: <br />2022 EDITION OF THE CALIFORNIA BUILDING CODE, <br />2022 EDITION OF THE CALIFORNIA RESIDENTIAL CODE, <br />2022 EDITION OF THE CALIFORNIA MECHANICAL CODE, <br />2022 EDITION OF THE CALIFORNIA PLUMBING CODE, <br />2022 EDITION OF THE CALIFORNIA ELECTRIC CODE, <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE, <br />2022 CALIFORNIA ENERGY CODE (TITLE 24) AND, <br />CITY AMENDMENTS AND MUNICIPAL CODE. <br />1 (N) MAIN ELEC PANEL 200AMP; <br />DUAL GANG METER; MIN. 20' UFER GROUND <br />2 <br />3 (E) CONCRETE WALKWAY <br />4 (E) DRIVEWAY <br />5 <br />6 <br />7 (E) LANDSCAPE <br />8 (E) TREE <br />9 (E) AC UNIT <br />10 <br />11 (N) WATER HEATER <br />12 SPACE FOR SOLAR PANEL INSTALLATION <br />(SEPARATE FUTURE PERMIT) <br />SYMBOLS LEGEND <br />DRAINAGE DIRECTION AND SLOPE <br />PROPERTY LINE CORNER POINTS AND ELEVATION DATUM <br />KEYNOTE CALLOUTS <br />EXISTING WALL TO REMAIN AND NEW WALLS <br />WALL TO BE DEMOLISHED <br />2% <br /># <br />13 (E) GATE <br />14 <br />15 (N) AC UNIT <br />INVERTER / METERING EQUIPMENT & PATHWAY FOR ROUTING <br />FROM THE SOLAR ZONE TO THE MAIN SERVICE PANEL. <br />(N) MAILBOX FOR ACCESSORY DWELLING UNIT <br />ADJACENT TO MAIN HOUSE MAILBOX <br />16 <br />PROPOSED LOCATION OF THE NATURAL GAS METER <br />TYPICALLY WITHIN FIVE FEET OF THE STRUCTURE’S <br />FRONT WALL BUT NOT CLOSER THAN ONE FOOT FROM <br />THE FRONT EDGE <br />17 <br />(E) MAIN HOUSE ELEC. METER18 <br />(E) GAS METER19 <br />(E) WATER METER 20 <br />SETBACKS INDICATE REQUIRED MINIMUM DISTANCE FROM <br />PROPERTY LINES. CONTRACTOR TO VERIFY ON SITE. <br />PV SYSTEM WILL BE UNDER A SEPARATE PERMIT <br />• THE MAIN ELECTRICAL SERVICE PANEL RATING OF 200 AMPS. <br />THE MAIN SERVICE PANEL SHALL HAVE A MINIMUM BUSBAR A <br />DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR <br />ELECTRIC INSTALLATION. THE RESERVED SPACE SHALL BE <br />POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT <br />FEEDER LOCATION OR MAIN CIRCUIT LOCATION AND SHALL BE <br />PERMANENTLY MARKED AS "FOR FUTURE SOLAR ELECTRIC". <br />1.1 (N) ADU SUB ELEC PANEL 125 AMP <br />(N) MAIN HOUSE SUB ELEC PANEL 125 AMP <br />13.1 (N) GATE <br />(N) 1" WATER METER MINIMUM PER CITY <br />REQUIREMENTS21 <br />SEPARATE PERMIT <br />(E) 5' TALL PERIMETTER <br />FENCING <br />(N) ADU WATER POINT OF CONNECTION <br />(N) ADU WATER POINT OF CONECTION <br />NEW (1) 24" BOX CANOPY TREE <br />NEW (6) 5-GAL SHRUBS <br />NEW CONCRETE AREA AND <br />WALKWAYS <br />DRIVEWAY <br />(N) GRASS <br />NEW PERMEABLE HARDSCAPE <br />(N) ADU GAS POINT OF CONNECTION <br />PARK & REC DEVELOPMENT <br />FEE CALCULATION <br />(ADU SF / SFD SF) <br />799 SF / 1012 SF = 0.79 <br />THE ADU SF / SFD SF RATIO IS PROVIDED FOR PARK & REC FEE <br />CALCULATION PURPOSES ONLY. THE APPLICANT IS RESPONSIBLE <br />FOR VERIFYING THE ACCURACY OF THE STATED SFR SF (SQUARE <br />FOOTAGE OF THE EXISTING PRIMARY RESIDENCE). BUILDING <br />SAFETY STAFF ARE NOT RESPONSIBLE FOR CONFIRMING THE <br />ACCURACY OF THE PROVIDED SFR SF <br />MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF <br />THIS PLAN REVIEW AND APPROVAL. MEP ARE SUBJECT TO <br />BUILDING FIELD INSPECTION. <br />• MINIMUM 2.19(KW) PHOTOVOLTAIC SYSTEM WILL BE <br />SUBMITTED UNDER A SEPARATE PERMIT AND SHALL BE <br />ISSUED PRIOR TO BUILDING FRAME INSPECTION REQUEST. <br />2.1 (N) 5' TALL PERIMETER <br />FENCING <br />2.2 (N) 2'-6" HEIGHT <br />FRONT YARD FENCING <br />1 <br />1 <br />1 <br />1 <br />1 <br />DRAFTING BY: <br />BB BROTHERS CORP <br />949 SOUTH COAST DRIVE, COSTA MESA, CA 92626 <br />SIGNATURE: <br />07/16/2024 <br />15 (N) 4'-6" HEIGHT STUCCO FINISH WALL <br />SCREENING. FINISH COLOR MATCH WITH <br />THE ADU WALL FOR AC CONDENSER1 <br />1 <br />1 <br />3FRONT YARD FENCING ELEV. <br />1 <br />ARCHITECTURAL <br />A.01 TITLE SHEET / SITE PLANS / ROOF PLANS <br />A.02 CALGREEN MANDATORY MEASURES <br />A.03 CALGREEN MANDATORY MEASURES <br />A.04 MAIN HOUSE (E) FLOOR PLAN & (E) ELEVATION <br />A.05 ADU FLOOR PLAN & ELECTRICAL/LIGHTING PLAN <br />A.06 ADU ELEVATIONS & SECTIONS <br />A.07 WALL AND ROOF DETAILS <br />A.08 ARCHITECTURAL DETAILS <br />A.09 AGING-IN-PLACE / FALL PREVENTION NOTES & <br />FEATURES / ELECTRIC-READY REQUIREMENTS <br />A.10 FEMA BASE FLOOD ELEVATION CERTIFICATE <br />A.11 SOIL REPORT <br />STRUCTURAL <br />S-0.10 GENERAL NOTES & REQUIREMENTS <br />S-0.11 GENERAL NOTES & REQUIREMENTS <br />S-0.20 TYPICAL DETAILS <br />S-1.0 FOUNDATION PLAN & ROOF FRAMING PLAN <br />SD1.0 FOUNDATION DETAILS <br />SD2.0 STRUCTURAL DETAILS <br />TITLE 24 <br />T24.1 TITLE 24 <br />T24.2 TITLE 24 (CONT.) <br />T24.3 TITLE 24 (CONT.) <br />GRADING (REFERENCE ONLY) REFER TO PERMIT P0114629 <br />1 TITLE SHEET <br />2 PRECISE GRADING & UTILITY PLAN <br />3 EROSION CONTROL PLAN