My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD- 2201 S Ross St & 414 W Anahurst Pl - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Anahurst Pl
>
414 W Anahurst Pl
>
HOLD- 2201 S Ross St & 414 W Anahurst Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:00:58 AM
Creation date
2/24/2026 5:00:14 AM
Metadata
Fields
Template:
Plan
Permit Number
101121647
Full Address
414 W Anahurst Pl
Street Number
414
Street Direction
W
Street Name
Anahurst
Street Suffix
Pl
Permit Number (Not in SAPIN)
10212646
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)264 @ 12' 3 1/2"1406 (1.50")Passed (19%)--1.0 D + 1.0 Lr (Alt Spans) <br />Shear (lbs)243 @ 11' 10 5/16"1238 Passed (20%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Moment (Ft-lbs)730 @ 6' 9 1/8"1060 Passed (69%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Live Load Defl. (in)0.305 @ 6' 8 3/4"0.587 Passed (L/462)--1.0 D + 1.0 Lr (Alt Spans) <br />Total Load Defl. (in)0.544 @ 6' 8 13/16"0.783 Passed (L/259)--1.0 D + 1.0 Lr (Alt Spans) <br />Member Length : 13' 1 5/16" <br />System : Roof <br />Member Type : Joist <br />Building Use : Residential <br />Building Code : IBC 2024 <br />Design Methodology : ASD <br />Member Pitch : 4/12 <br />•Deflection criteria: LL (L/240) and TL (L/180). <br />•Overhang deflection criteria: LL (2L/240) and TL (2L/180). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•A 15% increase in the moment capacity has been added to account for repetitive member usage. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger <br />• ¹ See Connector grid below for additional information and/or requirements. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Beveled Plate - DF 3.50"3.50"1.50"143 181 324 Blocking <br />2 - Hanger on 5 1/2" DF beam 3.50"Hanger¹1.50"122 156 278 See note ¹ <br />•Maximum allowable bracing intervals based on applied load. <br />•Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)10' o/c <br />Bottom Edge (Lu)12' 11" o/c <br />Connector: Simpson Strong-Tie <br />Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories <br />2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d <br />•Refer to manufacturer notes and instructions for proper installation and use of all connectors. <br />Dead Roof Live <br />Vertical Load Location (Side)Spacing (0.90)(1.25)Comments <br />1 - Uniform (PSF)0 to 12' 7"16"15.0 20.0 Default Load <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />ADU, Roof: Joist <br />1 piece(s) 2 x 6 DF No.2 @ 16" OC <br />Page 6
The URL can be used to link to this page
Your browser does not support the video tag.