Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)588 @ 0 3281 (1.50")Passed (18%)--1.0 D + 1.0 Lr (All Spans) <br />Shear (lbs)451 @ 8 3/4"3806 Passed (12%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs)918 @ 3' 1 1/2"3737 Passed (25%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Live Load Defl. (in)0.019 @ 3' 1 1/2"0.208 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) <br />Total Load Defl. (in)0.036 @ 3' 1 1/2"0.313 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) <br />Member Length : 6' 3" <br />System : Wall <br />Member Type : Header <br />Building Use : Residential <br />Building Code : IBC 2024 <br />Design Methodology : ASD <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•Applicable calculations are based on NDS. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Floor Live Roof Live Factored Accessories <br />1 - Trimmer - DF 1.50"1.50"1.50"275 42 313 588 None <br />2 - Trimmer - DF 1.50"1.50"1.50"275 42 313 588 None <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)6' 3" o/c <br />Bottom Edge (Lu)6' 3" o/c <br />Dead Floor Live Roof Live <br />Vertical Loads Location Tributary <br />Width <br />(0.90)(1.00)(1.25)Comments <br />0 - Self Weight (PLF)0 to 6' 3"N/A 6.4 ---- <br />1 - Uniform (PSF)0 to 6' 3"1' 4"5.0 10.0 -Default Load <br />2 - Uniform (PSF)0 to 6' 3"5'15.0 -20.0 <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />ADU, Wall: Header <br />1 piece(s) 4 x 8 DF No.2 <br />Page 12