Laserfiche WebLink
ELECTRICAL N❑TES1 <br />CITY OF SANTA ANA <br />v_o <br />DOOR SCHEDULE: <br />yl <br />1. BOTTOM OF CEILING IS AT 8' ABOVE FINISHED FLOOR AT ALL AREAS <br />WITHIN THE HOUSE. <br />2, COUNTERTOPS IN THE KITCHEN, DINING AREA AND SIMILAR AREAS <br />REQUIRE A RECEPTACLE BE PR❑VIDED FOR EACH COUNTER SPACE <br />WIDER THAN 12' S❑ THAT NO P❑INT IS MORE THAN 24' FROM AN <br />OUTLET. ALL OUTLETS IN KITCHEN SERVING COUNTERTOP SURFACES <br />INCLUDING ISLAND SHALL BE GFI. <br />3. ALL INSTALLED LUMINAIRES MUST BE HIGH EFFICACY IN ACCORDANCE <br />WITH TABLE 150.0-A. <br />4. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT <br />LEAST ONE LUMINAIRE IN EACH OF THESE SPACES MUST BE <br />CONTROLLED BY A VACANCY SENSOR. <br />5, DIMMERS OR VACANCY SENSORS MUST CONTROL ALL LUMINAIRES <br />REQUIRED TO HAVE LIGHT SOURCES C❑MPLIANT WITH REFERENCE <br />J❑INT APPENDIX JA8, EXCEPT LUMINAIRES IN CLOSETS LESS THAN 70 <br />SQUARE FEET AND LUMINAIRES IN HALLWAYS PER 150,0(k)2K. <br />6. OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL <br />BUILDING, OR TO OTHER BUILDINGS ON THE SAME LOT, MUST MEET <br />THE REQUIREMENT IN ITEM § 150.0(K)3AI (ON AND OFF SWITCH) AND <br />THE REQUIREMENTS IN EITHER ITEM § 150,0(K)3AII (PHOTOCELL AND <br />M❑TI❑N SENSOR) OR ITEM § 150,0(K)3AIII (PHOTO CONTROL AND <br />AUT❑MATIC TIME SWITCH CONTROL, ASTR❑N❑MICAL TIME CLOCK, OR <br />EMCS). <br />7. UNDERCABINET LIGHTING MUST BE SWITCHED SEPARATELY FROM <br />OTHER LIGHTING SYSTEMS, <br />8. OCCUPANCY SENSORS MUST HAVE NO MANUAL ❑VERRIDE, 30-MINUTE <br />MAXIMUM TIMER AND BE MICR❑WAVE/ULTRAS❑NIC OR PASSIVE <br />INFRARED TYPE. <br />9. HIGH EFFICACY LUMINARIES MUST BE PIN BASED. <br />11. A GFI 120 VOLT RECEPTACLE SHALL BE PROVIDED AT FRONT AND BACK OF <br />THE DWELLING UNIT. <br />12. WALLS 2' WIDE OR GREATER SHALL HAVE AN OUTLET; OUTLETS SHALL BE <br />SPACED NO MORE THAN 12' APART AND A MAXIMUM OF 6' FROM END OF <br />WALLS OR OPENING. <br />13. HALLWAYS OVER 10' IN LENGTH SHALL BE PROVIDED WITH ELECTRICAL <br />OUTLETS. <br />14. ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, 15 AND 20 <br />AMPERE OUTLETS INSTALLED IN DWELLING UNITS SHALL BE PROTECTED BY AN <br />ARC -FAULT CIRCUIT INTERRUPTERS. THIS REQUIREMENT IS FOR ENTIRE <br />CIRCUIT, NOT JUST THE OUTLETS. <br />15. BRANCH CIRCUIT SERVING THE GARAGE RECEPTACLES SHALL NOT SERVE <br />OUTLETS OUTSIDE OF THE GARAGE. <br />16. ALL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL ON AND OFF <br />SWITCH THAT DOES NOT OVERRIDE TO ON AND ONE OF THE FOLLOWING: <br />CONTROLLED BY PHOTOCELL AND MOTION SENSOR, PHOTO CONTROL AND <br />AUTOMATIC SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR ENERGY <br />MANAGEMENT CONTROL SYSTEM. <br />17. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING <br />CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO <br />BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48" MEASURED <br />FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15" MEASURED <br />FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISHED FLOOR. <br />PLUMBING PIPE SPECIFICATION <br />APPLICATION <br />UNDER GROUND <br />ABOVE GROUND <br />WATER INSIDE THE BUILDING <br />PRE -INSULATED AQUAPEX <br />PEX PIPE OR COPPER "L" <br />WATER OUTSIDE THE BUILDING <br />COPPER "K" <br />COPPER "L" <br />WATER PIPES CONNECTION <br />TO THE WATER HEATER <br />N/A <br />COPPER "L" <br />N❑TES1 <br />1. ALL PIPES AND FITTINGS SHALL COMPLY WITH MATERIAL SPECIFICATI❑N <br />AS LISTED IN TABLE 604.1 OF THE PLUMBING CODE. <br />2. ALL PIPE AND FITTING TO BE PRODUCED BY A SINGLE MANUFACTURER <br />AND TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S <br />REC❑MMENDATI❑NS AND PLUBMING CODE. <br />3. HOT WATER PIPING SHALL BE INULATED; EXCEPT AT1 <br />A) PIPING THAT PENETRATES FRAMING MEMBERS FOR DISTANCE OF THE <br />FRAMING PENETRATI❑N, <br />B) PIPING BETWEEN THE FIXTURE CONTROL VALVE OR SUPPLY STOP <br />AND THE FIXTURE OR APPLIANCE. <br />NOTE: ALL KITCHEN <br />COUNTER SHALL HAS <br />COMBINATION AFCl/C <br />RECEPTACLES <br />fr\ rn rr'Mirni <br />�r �(N HOUSE 1ST FLOOR <br />�O 1 /4 = 12-Opp <br />NO. <br />SIZE (W'xH') <br />REMARKS <br />U-FACTOR <br />SHGC <br />0 <br />3'-O"x6'-8" <br />EXTERIOR SOLID <br />CORE DOOR. OPENABLE FROM INSIDE <br />0.2 <br />- <br />WITHOUT USE OF <br />KEY OR SPECIAL D 0 F O T <br />- <br />2'-6"x6'-8" <br />HOLLOW CORE D <br />OR ftpp <br />HOLLOW COR <br />1 Q <br />3 <br />2'-4"x6'-8" <br />OPENING AT BO <br />OM <br />WINDOW SCHEDULE: <br />NO. <br />SIZE (W'xH') <br />REMARKS <br />U-FACTOR <br />SHGC <br />O <br />4'x4' <br />VINYL DUAL GLA <br />EQ, SOW "E" TY PI, <br />0.30 <br />0.23 <br />SLIDING <br />VINYL DUAL GLA <br />ED, LOW "E" TYPE, <br />0 <br />2'x3' <br />SINGLE HUNG, OESMtCiEMPERED <br />GLASS <br />0.30 <br />0.23 <br />0 <br />3,X3, <br />VINYL DUAL GLA <br />ED, LOW "E" TYPE, <br />0.30 <br />0.23 <br />SLIDING <br />0 <br />5'x4' <br />VINYL DUAL GLA <br />0.30 <br />0.23 <br />SLIDING W TEMPERED GLASS <br />DOOR AND WINDOW SCHEDULE NOTES: <br />1. ALL GLAZING TO BE DOUBLE GLAZED AND TO HAVE NON-METAL FRAMES. <br />2. ALL WINDOWS BY "CRYSTAL PACIFIC WINDOWS" OR EQUAL. <br />3. WINDOWS 1 IS EMERGENCY ESCAPE AND RESCUE WINDOWS; THE FINISHED <br />SILL HEIGHT SHALL NOT BE MORE THAN 44" ABOVE THE FINISH FLOOR. <br />4. THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS MUST REMAIN <br />ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED. <br />5. SEE DOOR AND WINDOW FLASHING DETAILS SHOWN ON SHEET A4. <br />FLOOR PLAN LEGEND AND KEY NOTES: <br />0 EXISTING WALL <br />® NEW WALL <br />24"00" ATTIC ACCESS <br />❑1 DOOR THRESHOLD & LANDING, SEE DETAILS 5/A3. <br />ELECTRICAL LEGEND AND NOTES: <br />SD HARD WIRE WITH BATTERY BACKUP AND INTERCONNECTED <br />SMOKE ALARM PER R314 AND UL217 COMPLIANCE <br />© HARD WIRE WITH BATTERY BACKUP AND INTERCONNECTED CARBON <br />MONOXIDE DETECTOR PER R315 AND UL2034/2075 COMPLIANCE <br />RH 4" OR 6" RECESSED HIGH -EFFICACY LIGHT (LED LIGHTING, CERTIFIED TO THE <br />ENERGY COMMISSION) <br />EXTERIOR WALL MOUNTED HIGH -EFFICACY LUMINAIRE <br />TV CONNECTIONS WITH ELECTRICAL RECEPTACLE, ETHERNET <br />PORTS AND COAXIAL CABLES; COORDINATE W/ OWNER FOR <br />MOUNTING HEIGHT. <br />ELECTRICAL SWITCH <br />°$ DIMMER ELECTRICAL SWITCH <br />V$ ELECTRICAL SWITCH CONTROLLED BY VACANCY SENSOR <br />P$ ELECTRICAL SWITCH WITH PHOTOCONTROL/MOTION SENSOR <br />COMBINATION. SHALL BE HIGH EFFICACY LUMINARIES OR <br />BE CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR <br />COMBINATION WITH OVERRIDE. <br />DUPLEX RECEPTACLE, TEMPER RESISTANCE W/ ARC FAULT <br />CIRCUIT INTERRUPTER PROTECTION <br />GFI DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER. ALL <br />KITCHEN COUNTER RECEPTACLES SHALL BE COMBINATION AFCl/GFCI <br />�wP WATER PROOF DUPLEX RECEPTACLE WITH GROUND <br />FAULT INTERRUPTER CIRCUIT <br />DELTA BREEZ EXHAUST FAN, MODEL VFB25ACH: 80 CFM INTERMITTENT, 4" <br />DUCT AND MAX. OF 20 LF, 0.3 SONE. W/ HUMIDITY SENSOR CONTROL <br />10 20 AMP DEDICATED CIRCUIT IN BATHROOMS, TYP <br />TANKLESS WATER HEATER: 0.95 UEF, 200000 BTU/HR; ALSO PROVIDE <br />WEATHER-PROOF GFCI RECEPTACLE WITHIN 3' OF WATER HEATER <br />(�3 MINI SPLIT A/C -HEAT PUMP, SEE CF1R FORMS <br />® CARRIER GAS FURNACE OR SIMILAR: WITH AFUE=87% MIN. SEE DETAIL <br />2/A1 FOR CLEARANCE, ACCESS, SUPPORT LIGHTING AND RECEPTACLE <br />(�5 NEW 100 AMP SUBPANEL CONNECTING FROM MAIN DUAL 100 AMP <br />SERVICE PANEL. <br />© LAUNDRY CIRCUIT. SEPARTE CIRCUIT IS REQUIRED FOR LAUNDRY EQUIPMENT. <br />(�7 NEW STOVE HOOD VENT AS IAQ: BROAN NUTONE MANTRA AVSF136 SERIES: <br />375 CFM & 98.1% EFFICIENCY ® 1.5 SONES, 7" DUCT TO EXTERIOR AS PER <br />MANUFACTURER OR EQUAL W/ 280 CFM MINIMUM & 3 SONE. ADD LABELING <br />WITH FOLLOWING TEXT "THIS SWITCH CONTROLS THE INDOOR AIR QUALITY <br />VENTILATION FOR THE HOME. LEAVE IT ON UNLESS THE OUTDOOR AIR <br />QUALITY IS VERY POOR." <br />® HOOD & STOVE GFI RECEPTACLE AND DEDICATED 240V STOVE RECEPTACLE <br />@9 REFRIGERATOR RECEPTACLE & WATER VALVE OUTLET <br />10 DISH WASHER & GARBAGE DISPOSER GFI RECEP. W/ SWITCH <br />11 WHOLE HOUSE FAN: INSTALL "QUIETCOOL" MODEL QC ES-2250 WITH <br />= 2492 CFM; OR SIMILAR W/ AIRFLOW RATE = 2492 CFM MIN. <br />12 IAQ VENTILATION WITH "NUTONE" MODEL ZN80ML <br />CONTINUEOUSLY VENTED, AIRFLOW RATE = 80 CFM, 15 LF MAX <br />4"0 DUCT TO OUTSIDE, 0.3 SONE; OR SIMILAR WITH MIN 80 CFM <br />& 1 SONE. PROVIDE LABELING ON SWITCH CONTROLS: "SWITCH <br />FOR THE INDOOR AIR QUALITY VENTILATION FOR THE HOME. <br />LEAVE SWITCH IN THE 'ON' POSITION AT ALL TIMES UNLESS THE <br />OUTDOOR AIR QUALITY IS VERY POOR." <br />/o QROFKSS <br />co i <br />O C64806 crn <br />EXP 6/30/2025 <br />lF OF CAL\F�� <br />Q <br />0 <br />w <br />C7 <br />z <br />N <br />Q <br />W <br />� <br />C7 <br />U <br />�OCZ <br />��O <br />Q <br />J <br />CV 0 <br />Z <br />,� <br />O <br />Ova <br />LL_ <br />w <br />,.LJOOzCL_ <br />= <br />co <br />CO <br />Q O <br />-t <br />(J-) Cz <br />I+i <br />Zw <br />o <br />q <br />Wz <br />� <br />�o <br />w <br />O <br />� <br />H <br />H <br />w <br />w <br />r� <br />DRAWN BY: <br />F.L. <br />CHECK'D BY: <br />F.L. <br />SCALE: <br />AS NOTED <br />JOB NO.: <br />PCN #: <br />SHEET <br />r N UTIL <br />�O 1 /4 = 1 - 0 <br />TY P LAN -1ST FLOOR <br />