My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD - 4806 W Jason Ln & Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
J
>
Jason Ln
>
4806 W Jason Ln
>
HOLD - 4806 W Jason Ln & Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:00:58 AM
Creation date
2/24/2026 5:00:14 AM
Metadata
Fields
Template:
Plan
Permit Number
102122901
102122902
Full Address
4806 W Jason Ln
4806 W Jason Ln Unit# 2
Street Number
4806
Street Direction
W
Street Name
Jason
Street Suffix
Ln
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />®® <br />n <br />x <br />Q <br />co © o0 <br />rn <br />ELECTRICAL RECEPTACLE OUTLET, <br />SWITCH, DOORBELL & CONTROL HEIGHTS <br />6 <br />PR❑VIDE 2x <br />BL❑CKING BETWEEN <br />STUDS FOR FUTURE <br />GRAB BARS 24" MIN <br />o <br />PR❑VIDE 2: <br />BL❑CKING I <br />STUDS FOR <br />GRAB BARS <br />12" 42" MIN , <br />MAX <br />PR❑VIDE 2x <br />BL❑CKING BETWEEN <br />STUDS FOR FUTURE <br />GRAB BARS <br />SIDE WALL <br />6" MAX <br />TUB BACK WALL <br />PROVIDE 2x <br />[BL❑CKING BETWEEN <br />STUDS FOR FUTURE <br />GRAB BARS <br />FULL WIDTH AT THE <br />z SHOWER STALL WALLS <br />rn <br />6" MAX <br />40" MIN <br />16" <br />BACK WALL <br />-PR❑VIDE 2x <br />BL❑CKING BETWEEN <br />STUDS FOR FUTURE <br />GRAB BARS <br />PR❑VIDE ADDITI❑NAL <br />BACKING FOR FOLD <br />AWAY GRAB BAR <br />PR❑VIDE 2x <br />24" MIN BL❑CKING BETWEEN <br />STUDS FOR FUTURE <br />GRAB BARS <br />E. <br />rn <br />N i"7 <br />TUB HEAD END WALL <br />PR❑VIDE 2x <br />BL❑CKING BETWEEN <br />STUDS FOR FUTURE <br />GRAB BARS <br />z - z <br />F. 7'. b�� ..... / <br />Q <br />Q <br />N <br />N <br />rM <br />rr) <br />SHOWER CONTROL END SIDE WALL SHOWER BACK <br />WALL SHOWER SIDE WALL <br />AGING -IN -PLACE AND FALL PREVEN11ON NOTES: <br />NEWLY CONSTRUCTED DWELLINGS SUBJECT TO THE REQUIREMENTS OF THIS CODE SHALL BE DESIGNED <br />R327.1.2 ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING <br />AND CONSTRUCTED IN ACCORDANCE WITH SECTIONS R327.1.1 THROUGH R327.1.4. <br />CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE <br />USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM THE <br />R327.1.1 REINFORCEMENT FOR GRAB BARS. AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE <br />TOP OF THE OUTLET BOX AND NOT LESS THAN 15" MEASURED FROM THE BOTTOM <br />PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. <br />OF THE OUTLET BOX ABOVE THE FINISHED FLOOR. <br />1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE <br />ENFORCING AGENCY. <br />R327.1.3 INTERIOR DOORS <br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER OR OTHER <br />EFFECTIVE 7/1/2024, AT LEAST ONE BATHROOM AND ONE BEDROOM ON THE ENTRY <br />CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE <br />LEVEL SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF NOT LESS THAN <br />LOCATED BETWEEN 32" AND 394" ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. <br />32", MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM <br />3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR <br />THE CLOSED POSITION; OR, IN THE CASE OF A TWO- OR THREE-STORY SINGLE <br />ONE SIDE WALL AND THE BACK WALL. <br />FAMILY DWELLING, ON THE SECOND OR THIRD FLOOR OF THE DWELLING IF A <br />4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />BATHROOM OR BEDROOM IS NOT LOCATED ON THE ENTRY LEVEL. <br />5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH <br />END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A <br />R327.1.4 DOORBELL BUTTONS <br />LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6" ABOVE <br />DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48" <br />THE BATHTUB RIM. <br />ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL <br />EXCEPTIONS: <br />BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES <br />1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF <br />ARE REQUIRED TO BE INSTALLED ABOVE 48" MEASURED FROM THE EXTERIOR FLOOR <br />ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF <br />OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE <br />FLOOR MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY <br />PROVIDED AT A HEIGHT NOT EXCEEDING 48" ABOVE EXTERIOR FLOOR OR LANDING, <br />THE ENFORCING AGENCY. <br />MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. <br />2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE -FABRICATED SHOWER <br />ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORY INSTALLED GRAB BARS OR <br />WHEN FACTORY INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB <br />BARS SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR MOUNTED <br />GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />4. BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE <br />INSTALLATION OF REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR <br />INSTALLATION OF FLOOR MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE <br />METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS <br />INSTALLED ON CONCRETE SLAB FLOORS. <br />AGING —IN —PLACE & <br />FALL PREVENTION <br />ADDITION EXISTING <br />WEST ELEVATION <br />1 /4" = 1'-0" <br />ROOF <br />Cyg141►[e] <br />NOTE: ADU CONVERSION SHALL <br />MAINTAINED SAME COLOR, MATERIAL AND <br />ARCHITECTURAL STYLE AS EXISTING SFD. <br />EXISTING <br />ADDITIONNOTE: <br />EASTELEVATION <br />ADU CONVERSION HALL <br />MAINTAINED SAME COLORS MATERIAL AND <br />1 /4" = 1 ' — O" <br />ARCHITECTURAL STYLE AS EXISTING SFD. <br />12 <br />4 <br />Eull <br />00 00 <br />co <br />ro I <br />N <br />ADDITION EXISTING <br />NORTH ELEVATION <br />1 /4" = 1'-0" <br />ROOF PROPOSED ELEVATION LEGEND AND NOTES: <br />El EXG FASCIA BO�TO OR�egar d <br />2 EXISTING'ROOFAVG TO REMAIN <br />CEIL G d 3 EFISTE 13JAIRTAINI SSUANC <br />I <br />N ® GARAGE DOOR INFILL WITH STUCCO FINISH TO <br />II MATCH EXISTING HOUSE IN STYLE AND COLORING <br />z 0 NEW WINDOW & DOOR TO MATCH EXISTING H IN STYLE AND COLORING <br />1 a rN ASCIA BOARD TO MATCH EXISTING <br />D � NEW ROOFING TO MATCH EXISTING <br />ADU FLR <br />NOTE: ADU CONVERSION SHALL <br />MAINTAINED SAME COLOR, MATERIAL AND <br />ARCHITECTURAL STYLE AS EXISTING SFD. <br />lflNEW ADDRESS WITH UNIT NUMBERING IN FRONT OF ADU <br />AND AT FRONT OF (E) MAIN HOUSE WITH CONTRACT <br />COLORING TO BACKGROUND. NUMBERING SHALL BE 4" <br />MIN HIGH AND r STROKE WIDTH. <br />EXISTING I, <br />n <br />NOTE: ADU CONVERSION HALL <br />S O U T H ELEVATION MAINTAINED SAME COLORS MATERIAL AND <br />1 /4" = 1 '- O" ARCHITECTURAL STYLE AS EXISTING SFD. <br />ROOF <br />FINIS RRADE <br />SECTION A <br />_f <br />NOTE: ADU CONVERSION SHALL 1/4" <br />MAINTAINED SAME COLOR, MATERIAL AND <br />ARCHITECTURAL STYLE AS EXISTING SFD. <br />1 "I <br />�o QROF KSS /p�! <br />C64806 crn <br />EXP 6/30/2025 <br />sr C l V <br />qTF OF CAO��� <br />Q <br />O <br />F—' <br />z <br />W <br />O <br />N <br />~ <br />LLJ <br />Lu <br />O o <br />06 <br />zzZNQ <br />J <br />—i <br />g)(s) <br />� <br />—zz<z <br />(1)OOUO <br />Q <br />Q <br />> <br />� <br />QLLj <br />Q <br />LL <br />U <br />Q9 <br />J <br />—I <br />LlJ <br />w0Oz� <br />w <br />= <br />03 <br />co <br />QC) <br />O <br />x <br />o <br />� <br />e <br />q <br />q <br />z <br />FH <br />Wz <br />Zo <br />w <br />H <br />H <br />w <br />w <br />Q <br />DRAWN BY: <br />F.L. <br />CHECK'D BY: <br />F.L. <br />SCALE: <br />AS NOTED <br />JOB NO.: <br />PCN #: <br />SHEET <br />A2a <br />
The URL can be used to link to this page
Your browser does not support the video tag.