My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD - 2525 & 2527 S Birch St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Birch St
>
2525 S Birch St
>
HOLD - 2525 & 2527 S Birch St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:00:44 AM
Creation date
2/24/2026 5:00:15 AM
Metadata
Fields
Template:
Plan
Permit Number
101122275
Full Address
2525 S Birch St
Street Number
2525
Street Direction
S
Street Name
Birch
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
JO <br />B <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />AS NOTED <br />a <br />b <br />BZ 2/26/25 <br />DATE <br />SCALE <br />DRAWN <br />JOB <br />SHEET <br />REVISIONS BY <br />SHEET TITLE <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />/ <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br />25 <br />2 <br />5 <br /> <br />& <br /> <br />2 <br />5 <br />2 <br />7 <br /> <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />0002 <br />B.Z. <br />09.24.2024 <br />- <br />LE <br />G <br />A <br />L <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />AP <br />N <br />: <br />4 <br />1 <br />0 <br />- <br />3 <br />8 <br />1 <br />- <br />0 <br />6 <br />(714) 721 - 4067 <br />permitsync@gmail.com <br />PREPARED BY <br />BRYAN ZAMUDIO <br />09.01.2024 <br />BZ 3/28/25 <br />c BZ 4/24/25 <br />S <br />B <br />I <br />R <br />C <br />H <br /> <br />S <br />T <br />6 <br />WALL <br />DETAILS 2527 <br />TYPE 1 <br />25 GA. STUD <br />BASE CABINET, WALL HUNG <br />CABINET, SHELVES, LAVATORY, <br />GRAB BAR, ELECTRICAL PANEL, <br />TELEVISION, SURFACE <br />MOUNTED LIGHT FIXTURE <br />AND AS SHOWN. <br />6" X 25 GA. STL. STUD NOTCH & <br />FASTEN FLUSH TO STUDS W/ <br />(2) 8-18 WAFER HEAD SELF <br />DRILLING SCREWS PER STUD. <br />ALL BACKING TO SPAN <br />MINIMUM THREE STUDS. <br />TYPE 2 <br />20 GA. STUD <br />6" X 16 GA. STL. PLATE <br />FASTEN FLASH TO STUDS <br />W/ (2) 8-18 WAFER HEAD <br />SELF DRILLING SCREWS <br />PER STUD. ALL BACKING <br />TO SPAN MIN. THREE <br />STUDS. <br />ALL TOILET ACCESSORIES, <br />FIRE EXTINGUISHER <br />CABINET, WALL MOUNTED <br />TELEPHONE OUTLET, WALL <br />MOUNTED DOOR STOP, <br />WINDOW BLIND, AND AS <br />SHOWN. <br />NOTE: <br />3. <br />2. <br />1. EXTEND BACKING PLATES TO LAST STUD BEYOND FACE OF <br />FIXTURE OR ACCESSORY, TYP. <br />PROVIDE METAL SLEEVES THROUGH WALL FINISH AT <br />FIXTURE FASTENING, TYP. <br />ALL BACKING PLATES SHOWN OR NOT SHALL BE SCREWED <br />TO STUDS, TYP. <br />16" <br />16" <br />16" <br />16" <br />SEMI-RECESSED FIRE EXTINGUISHER <br />CABINET. VERIFY DEPTH AND WIDTH <br />REQ'D PER MANUFACTURER. <br />SEMI-RECESSED SOLID DOOR. PAINT <br />CABINET TO MATCH ADJACENT WALL <br />WITH DECAL READING: "FIRE <br />EXTINGUISHER" IN BLACK LETTERS. <br />METAL STUDS <br />5/8" GYP. BD. <br />NOTE: <br />1. ALL FIRE EXTINGUISHER SHALL <br />HAVE A VALID STATE FIRE <br />MARSHALL CERTIFICATION TAG <br />AFFIXED. <br />2. MAINTAIN FIRE RATING OF <br />PARTITION AT RATED WALL. <br />VIF <br />THERMOSTAT <br />TELEPHONE <br />WALL MOUNTED <br />STACK ONE ON TOP <br />DIMMER SWITCHES, <br />OF ANOTHER IF <br />NEEDED. <br />MIN. DISTANCE BETWEEN BOXES. <br />CLOSE TOGETHER MOUNT WITH <br />WHERE OUTLETS ARE SHOWN <br />MI <br />N <br />. <br />U. <br />O <br />. <br />N <br />. <br />MAX. <br />HANDLE <br />LEVER <br />46 <br />" <br /> <br />@ <br /> <br />S <br />I <br />D <br />E <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />C <br />H <br />OUTLETS SHOWN WITH A HEIGHT <br />GREATER THEN +30" ARE TO BE <br />MOUNTED VERTICALLY. WHERE OUTLETS <br />ARE SHOWN CLOSE TOGETHER MOUNT <br />WITH MIN. DISTANCE BETWEEN BOXES. <br />6" <br />12" <br />4" <br />5'-0" CLEAR TYP. <br />80 <br />" <br /> <br />( <br />6 <br />' <br />- <br />6 <br />" <br />) <br />44 <br />" <br /> <br />@ <br /> <br />F <br />R <br />O <br />N <br />T <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />C <br />H <br />48 <br />" <br />M <br />A <br />X <br />. <br />18 <br />" <br />30 <br />" <br /> <br />T <br />O <br /> <br />4 <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />2" <br />2" <br />DECK ABOVE <br />BASE WHERE OCCURS, <br />REFER TO FINISH PLAN. <br />WHERE CARPET OCCURS <br />3-5/8" x 20GA. METAL TRACK SECURED TO <br />STRUCTURE ABOVE W/ 1/4" x 2" POWER <br />ACTIVATED DRIVE PIN @ 2'-0" O.C. IN <br />ACCORDANCE W/ "HILTI" I.C.C. ESR #1663/ <br />LARR #25646. <br />METAL STUD-I.C.C. ESR-1166P / LARR 25889. <br />3-5/8" x 20GA. METAL FLOOR TRACK SECURED <br />TO STRUCTURE BELOW W/ 1/4" x 2" POWER <br />ACTIVATED DRIVE PIN @ 2'-0" O.C. IN <br />ACCORDANCE W/ "HILTI"- I.C.C.ES/ ESR #1663/ <br />LARR #25646. <br />NOTE: ADD 3M FIRE BARRIER SEALANT CP <br />25WB+.UL #1479 WHERE REQUIRED FOR ONE <br />HOUR RATED. <br />R8 BATT INSULATION WHERE REQ. <br />1/4" GAP, FILL WITH ACOUSTICAL SEALANT <br />AT BOTH SIDES CONT. DOW CHEMICAL LARR <br />#24637 (APPLIES TO F WALL ONLY) <br />NOTE: ADD 3M FIRE BARRIER SEALANT CP <br />25WB+.UL #1479 WHERE REQUIRED FOR ONE <br />HOUR RATED. <br />1/4" GAP, FILL WITH ACOUSTICAL SEALANT <br />AT BOTH SIDES CONT. DOW CHEMICAL LARR <br />#24637 (APPLIES TO F WALL ONLY) <br />S <br />S <br />PROVIDE THIS ADDITIONAL <br />SPACE IF DOOR IS EQUIPPED <br />WITH BOTH A LATCH AND A <br />CLOSER <br />TYP. LIGHT SWITCH LOCATION AT <br />SOLID WALL AT 48" AFF <br />CLEAR AT INTERIOR DOORS <br />CLEAR AT EXTERIOR DOORS <br />TYPICAL SWITCH LOCATION AT 48" <br />AFF FOR DOOR WITH SIDELIGHT <br />PUSH SIDE <br />FRONT APPROACH <br />PULL SIDE <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />18" MIN. <br />24" MIN. <br />9" <br />1'-0" <br />USG - SA923 "DRYWALL/STEEL FRAMED SYSTEM" <br />19'0"d* <br />15'0"d* <br />13'3"d <br />20'9"f <br />16'6"d <br />14'6"d <br />20'0"d <br />16'0"d <br />14'0"d <br />L/120 <br />L/240 <br />L/360 <br />24" <br />TYPICAL LIMITING HEIGHTS - INTERIOR STUD FRAMING <br />L/120 <br />L/240 <br />L/360 <br />L/120 <br />L/240 <br />L/360 <br />212ST20 2 1/2"16" <br />358ST20 3 5/8" <br />L/120 <br />L/240 <br />L/360 <br />16"L/120 <br />L/240 <br />L/360 <br />24" <br />20 gauage (.0329 min.) <br />358ST25 3 5/8" <br />L/120 <br />L/240 <br />L/360 <br />24" <br />16"L/120 <br />L/240 <br />L/360 <br />L/120 <br />L/240 <br />L/360 <br />212ST25 2 1/2"16" <br />24" <br />L/120 <br />L/240 <br />L/360 <br />24"L/120 <br />L/240 <br />L/360 <br />25 gauage (.0179 min.) <br />158ST25 1 5/8" <br />Stud <br />design. <br />Stud <br />width <br />16" <br />Stud <br />spacing <br />Allow. <br />defl. <br />9'9"d <br />8'6"d <br />13'3"f <br />11'3"f <br />10'3"d <br />16'6"d* <br />13'0"d* <br />11'6"d <br />18'6"d <br />14'9"d <br />13'0"d <br />17'9"d <br />14'0"d <br />12'3"d <br />16'3"f <br />13'0"d <br />11'3"d <br />15'6"d <br />12'3"d <br />10'9"d <br />23'0"d <br />18'3"d <br />16'0"d <br />24'0"d <br />19'0"d <br />16'6"d <br />14'6"d* <br />11'6"d <br />10'0"d <br />21'9"d* <br />17'3"d* <br />15'0"d* <br />13'6"f <br />13'6"f <br />13'0"d <br />13'6"f <br />13'6"f <br />12'3"d <br />9'6"d <br />16'9"f <br />16'0"d <br />14'0"d <br />16'9"f <br />16'9"f <br />14'9"d <br />13'6"f* <br />12'9"d* <br />11'0"d <br />16'9"f* <br />14'6"d* <br />12'9"d* <br />8'3"d <br />7'3"d <br />10'9"d <br />9'6"d 10'6"d <br />8'3"d <br />13'9"f <br />12'6"d <br />10'9"d <br />11'3"f <br />10'9"d <br />13'9"f <br />13'6"d <br />11'9"d <br />8'9"f <br />8'3"d <br />7'3"d <br />9'0"d <br />8'9"f <br />8'9"f <br />8'0"d <br />13'9"d <br />11'0"d <br />9'9"d <br />11'3"f <br />8'9"f <br />7'3"d <br />6'3"d <br />10'9"f <br />Partition, <br />one layer <br />Partition, <br />two layers <br />10'3"d <br />TABLE 8 <br />Furring, one <br />layer <br />USG FOOTNOTE: <br />LIMITING HEIGHT FOR 1/2" OR 5/8" THICK GYPSUM PANELS AND 5 PSF UNIFORM LOAD <br />PERPENDICULAR TO PARTITION OR FURRING. USE ONE-LAYER HEIGHTS FOR <br />UNBALANCED ASSEMBLIES; USE TWO-LAYER HEIGHTS FOR MULTI-LAYER ASSEMBLIES. <br />FOR FURRING, STUD ATTACHED TO TOP AND BOTTOM RUNNERS AND FREE-STANDING UP <br />TO 12-FT. HEIGHT. *STUDS EXCEEDING 12-FT. HEIGHT REQUIRE MID-HEIGHT ANCHOR TO <br />EXTERIOR WALL. ASSEMBLIES WITHOUT FACE PANELS AND CHASE WALL PARTITIONS <br />REQUIRE VERTICAL CROSS BRACES 4FT. O.C. MAX. LIMITING CRITERIA d-DEFLECTION, <br />f-BENDING STRESS, v-END REACTION SHEAR. CONSULT LOCAL CODE AUTHORITY FOR <br />LIMITING CRITERIA. <br />IMPORTANT: THE "TYPICAL" PHYSICAL AND STRUCTURAL PROPERTIES AND APPLICABLE <br />TABLES PUBLISHED IN THIS FOLDER REPRESENT CHARACTERISTICS AND/OR STEEL STUDS <br />CURRENTLY AVAILABLE FROM A GROUP OF STEEL STUD MANUFACTURES. CONSULT STUD <br />MANUFACTURE'S PHYSICAL AND STRUCTURAL PROPERTIES, STUD THICKNESSES AND <br />LIMITING HEIGHT TABLES TO DETERMINE FINAL STUD SELECTION. <br />NOTE: GENERAL CONTRACTOR TO PROVIDE ALTERNATE OR EQUAL <br />PRODUCT MATERIAL SPECIFICATION IF USG SA923 "DRYWALL/STEEL <br />FRAMED SYSTEM" IS NOT UTILIZED FOR THIS PROJECT. <br />LARR 25163 <br />3M FIRE BARRIER PUTTY <br />CONT. ACOUSTICAL SEALANT <br />CONCRETE SLAB <br />BOTH SIDES <br />4 <br />- <br />1 LAYER 5/8" TYPE "X" GYP. BD. EA. SIDE FROM <br />SLAB TO SLAB SEAL ALL PENETRATIONS <br />3 5/8" X 20 GA. METAL STUDS @ 16" O.C. <br />FROM SLAB TO SLAB <br />20 GA. METAL RUNNER AMMO SHOT W/ <br />HILTI ANCHORS @ 24" O.C. (TYP.) <br />NOTE: <br />2" WALL ANGLE @ PERIMETER & SLAB <br />TO SLAB PARTITIONS IN LOS ANGELES. <br />NOTES: <br />1. ALL GYP. BD. SHEETS ARE TO <br />RUN VERTICALLY <br />2. NO JOINTS EXCEPT @ STUDS <br />3. SEAL ALL PENETRATIONS <br />4. ALL HVAC DUCTS <br />PENETRATING WALL SHALL <br />RECEIVE APPROPRIATELY SIZED <br />FIRE DAMPERS <br />NOTE: <br />CAULK AROUND ALL <br />PENETRATIONS WITH FIRE <br />PROOF CAULKING <br />FRICTION FIT FIBERGLAS ACOUSTIC <br />INSULATION (FULL HEIGHT OF GYP. BD.) <br />WOOD STRUCTURE ABOVE <br />GYP. BOARD CLOSER (AS REQUIRED) TO SEAL <br />ALL VOIDS WHERE PERPENDICULAR TO DECK <br />3 5/8" X 20 GA. METAL <br />STUDS @ 24" O.C. <br />(TEST NO. NGC2438, <br />DESIGN NO. BASED ON <br />T-3296) <br />3 5/8" X 20 GA. METAL <br />STUDS @ 24" O.C. <br />ATTACHED TO METAL <br />STUDS WITH 4 #10 <br />SELF TAPPING <br />SCREWS <br />3 5/8" X 20 GA. METAL <br />TRACK SHOT NAILED <br />TO CONC. SLAB AS <br />REQUIRED (TYP ALL <br />WALLS) <br />DEMISING WALL <br />EXISTING FLOORING <br />SYSTEM <br />REFER TO SHEET RCP <br />FOR LIGHT FIXTURE <br />SEE PLAN A-2.0 <br />8' <br />- <br />0 <br />" <br />4 <br />- <br />TOP TRACK. <br />TOP OF WALL <br />CORNER BRACING; SEE #3/- <br />WALL TYPE "A" IN <br />PLAN VIEW (TOP <br />TRACK) <br />NOTES: <br />1.CORNER BRACING NOT REQUIRED WHEN <br />LENGTH OF WALL IS 10'-0" OR LESS. <br />2.NOT USED. <br />3.BRACING SHALL BE: <br /> 6'-0" OR LESS: <br /> 3 5/8" X 20 GA. MTL STUD FLAT WITH (3) # 8 <br />S.M.S. EA END TO TOP TRACK. <br /> 6'-1" TO 10'-0": <br /> DOUBLE 3 5/8" X 20 GA. MTL STUDS ONE LAID <br />FLAT, WITH (3) #8 S.M.S. EACH END TO TOP <br />TRACK AND ONE LAID ON END WITH #8 <br />S.M.S. @ 24" O.C. TO FLAT STUD W/ (2) #8 <br />S.M.S. EA. END TO TOP TRACK. <br />SE <br />E <br /> <br />N <br />O <br />T <br />E <br /> <br />1 <br />6' <br />- <br />0 <br />" <br /> <br />U <br />. <br />N <br />. <br />O <br />. <br /> <br />T <br />O <br /> <br />1 <br />0 <br />' <br /> <br />M <br />A <br />X <br />. <br />SE <br />E <br /> <br />N <br />O <br />T <br />E <br /> <br />3 <br />45° <br />6' <br />- <br />0 <br />" <br /> <br />U <br />. <br />N <br />. <br />O <br />. <br /> <br />T <br />O <br /> <br />1 <br />0 <br />' <br /> <br />M <br />A <br />X <br />. <br />SE <br />E <br /> <br />N <br />O <br />T <br />E <br /> <br />3 <br />AT BRACING GREATER <br />THAN 6'-0" ONLY. <br />DBL.MTL STUD BRACE <br />W/ (4) #8 S.M.S. @ 24' O.C. <br />TO FLAT STOP & (2) #8 S.M.S. <br />@ EA. END TO TOP TRACK <br />45° <br />CE <br />I <br />L <br />I <br />N <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br /> <br />( <br />1 <br />0 <br />' <br />- <br />0 <br />" <br />) <br />2' <br />- <br />1 <br />0 <br />" <br />COUNTERTOP <br />AND BACKSPLASH <br />- PL-1 <br />- <br />13 <br />3'-0" <br />REMOVABLE <br />PANEL - PL-1 <br />4" <br />PAINT <br />PAINT <br />PLASTIC LAMINATED <br />SUPPORT, TYP. - PL-1 <br />(open)B-1 <br />9" <br />10'-0" <br />SIM <br />REMOVABLE PANEL <br />1 <br />1 <br />/ <br />2 <br />" <br />8"MIN. <br />2' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br />2' <br />- <br />1 <br />0 <br />" <br />M <br />A <br />X <br />9" <br /> <br />M <br />I <br />N <br />. <br />2'-0" <br />11"MIN. <br />COUNTERTOP AND <br />BACKSPLASH PER <br />ELEVATIONS. <br />GARBAGE DISPOSAL, <br />WHERE APPLIES <br />INSULATE DRAIN, HOT <br />WATER WHEN EXPOSED <br />P- LAM INTERIOR <br />@ EXPOSED SURFACES <br />2' <br />- <br />5 <br />" <br />M <br />I <br />N <br />17" MIN. <br />6" MIN. <br />11 TYP. LIMITING HEIGHTS <br />NTS <br />4 SILL/PLATE CONNECTION <br />Scale : 1" = 1'-0" <br />5 STANDARD FIRE EXTINGUISHER CABINETS <br />Scale : 1-1/2" = 1'-0" <br />8 WALL BACKING DETAILS <br />NTS <br />9 TYP. OUTLETS MOUNTING HEIGTHS <br />Scale : 3/8" = 1'-0" <br />6 TYPICAL DOOR CLEARANCES <br />Scale : 1/2" = 1'-0" <br />2 WALL TYPE D <br />Scale : 1" = 1'-0" <br />1 WALL TYPE A <br />Scale : 1" = 1'-0" <br />3 CORNER BRACING DETAIL TYP <br />Scale : N.T.S. <br />12 MILLWORK @ BREAK ROOM <br />Scale: 1/2"=1'-0" <br />13 ACCESSIBLE SINK SECTION <br />Scale : 1" = 1'-0"
The URL can be used to link to this page
Your browser does not support the video tag.