Laserfiche WebLink
- 03 - <br />INTERIOR SWING DOOR <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />SAFETY <br />GLAZING <br />- 01 - <br />EXTERIOR <br /> SINGLE MULTI-LITE FRENCH DOOR <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />- 04 - <br />INTERIOR LOUVER DOOR <br />(MIN. OPENING OF 100SF) <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />- 05 - <br />INTERIOR SWING DOOR <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />- 06 - <br />INTERIOR POCKET DOOR <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />- 07- <br />INTERIOR CLOSET DOOR <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />- 02- <br />INTERIOR CLOSET DOOR <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />MINIMUM SIZE <br />WINDOW FOR 24" CLEAR WIDTH <br />MINIMUM SIZE <br />WINDOW FOR 24" CLEAR HEIGHT <br />FINISH FLOOR <br />EGRESS WINDOW REQUIREMENTS PER CRC. SECTION 1029 <br />OPENABLE <br />AREA = MIN. <br />5.7 SF NET <br />AREA 2' - 0" <br />3' <br /> <br />- <br /> <br />5 <br />" <br />3' <br /> <br />- <br /> <br />8 <br />" <br />2' - 10" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />3' <br /> <br />- <br /> <br />8 <br />" <br />CLRCLR <br />CL <br />R <br />CL <br />R <br />MA <br />X <br />MA <br />X <br />FLOOR <br />SLAB ON GRADE <br />VINYL PLANKS <br />UNDERLAYMENT <br />CAST-IN-PLACE CONCRETE <br />NOTES: <br />1. IN BATHROOMS USE CERAMIC <br />TILE IN PLACE OF VINYL <br />CEILING <br />TYPICAL <br />WOOD FRAMING, INSULATED <br />GYPSUM WALL BOARD 1/2" <br />EXTERIOR WALL <br />TYPICAL 2x4EWP4 <br />HOUSE WRAP <br />SIDING ON MESH <br />PLYWOOD, SHEATHING GRADE 5/8" <br />WOOD FRAMING, INSULATED <br />GYPSUM WALL BOARD 1/2" <br />NOTES: <br />1. INSULATION: MIN. R-15, MINERAL <br />WOOL OR FIBERGLASS <br />ROOF <br />ASPHALT SHINGLE <br />WOOD FRAMING <br />PLYWOOD, SHEATHING <br />GRADE 5/8" <br />UNDERLAYMENT <br />ASPHALT ROOFING SHINGLE <br />INTERIOR WALL <br />TYPICAL IW4 <br />GYPSUM WALL BOARD 1/2" <br />WOOD FRAMING <br />GYPSUM WALL BOARD 1/2" <br />NOTES: <br />1. IN BATHROOMS USE WATERPROOF <br />CEMENT BACKER BOARDS OR GREENBOARDS. <br />2. USE CEMENT BACKER BOARDS IN WALL <br />AREAS IN DIRECT CONTACT WITH WATER. <br />INTERIOR WALL <br />TYPICAL IW6 <br />GYPSUM WALL BOARD 1/2" <br />WOOD FRAMING <br />GYPSUM WALL BOARD 1/2" <br />NOTES: <br />1. IN BATHROOMS USE WATERPROOF <br />CEMENT BACKER BOARDS OR GREENBOARDS. <br />2. USE CEMENT BACKER BOARDS IN WALL <br />AREAS IN DIRECT CONTACT WITH WATER. <br />EXTERIOR SINGLE-HUNG <br />WINDOW -01- <br />EGRESS <br />VI <br />F <br />3' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />5 1/2" <br />2" <br />3 <br />1 <br />/ <br />2 <br />" <br />EXTERIOR SINGLE-HUNG <br />WINDOW -02- <br />SAFETY <br />GLAZING <br />VI <br />F <br />4' <br />- <br />0 <br />" <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />5 1/2" <br />2" <br />3 <br />1 <br />/ <br />2 <br />" <br />EXTERIOR SINGLE-HUNG <br />WINDOW -03- <br />VI <br />F <br />3' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />SE <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />SEE SCHEDULE <br />5 1/2" <br />2" <br />3 <br />1 <br />/ <br />2 <br />" <br />SAFETY <br />GLAZING24" MIN. OPENING <br />DATE: <br />P.M.: <br />DRAWN BY: <br />JOB NO.: <br />26081 Merit Cir, STE 111 <br />Laguna Hills, CA 92653 <br />909-257-7040 WWW.BNDESIGNBUILDINC.COM <br />THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN <br />DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK <br />EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. <br />D ES I GNBUILDCNI <br />7/ <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />1 <br />1 <br />: <br />1 <br />8 <br />: <br />2 <br />1 <br /> <br />A <br />M <br />A4.0 <br />B.N. <br />F.M. <br />WINDOW & DOOR <br />SCHED., TYPES,& <br />NOTES <br />07.11.24 <br />2024001108 <br />UNIT 2, 606 S VAN <br />NESS AVE, <br />SANTA ANA, CA <br />92701 <br />ACCESSORY <br />DWELLING <br />UNIT <br />DOOR <br />NUMBER <br />NAME. <br />TYPE <br />DOOR DIMENSION DOOR MATERIAL & FINISH <br />FRAME MATERIAL & <br />FINISH <br />HARDWARE <br />HARDWARE <br />W H T MATERIAL FINISH <br />GLASS <br />FINISH MATERIAL FINISH EX <br />I <br />T <br /> <br />D <br />E <br />V <br />I <br />C <br />E <br />FI <br />R <br />E <br />- <br />R <br />A <br />T <br />E <br />D <br />01 FRENCH Door 3' - 0"7' - 0"2"WOOD AND GLASS FF CLEAR FF U - FACTOR 0.3, SHGC 0.23 <br />02 CLOSET Door 4' - 0"6' - 8"1 3/4"WOOD FF FF <br />04 LOUVER Door 2' - 8"6' - 8"1 3/4"WOOD FF FF <br />05 SWING Door 2' - 8"6' - 8"1 3/4"WOOD FF FF <br />06 POCKET Door 2' - 4"6' - 8"1 3/4"WOOD FF FF <br />07 CLOSET Door 7' - 0"6' - 8"1 3/4"WOOD FF FF <br />DOOR TYPES <br />DOOR SCHEDULEDOOR SCHEDULE 1. ALL MOUNTING ACCESSORIES SHALL BE PROVIDED ACCORDING TO MANUFACTURER'S <br />REQUIREMENTS. AND MUST COMPLY WITH CBC 1010.1.9 <br />2. DOORS/WINDOWS MANUFACTURER, MODEL AND DETAILS ARE FOR DESIGN PURPOSES AND SHALL BE <br />VERIFIED WITH THE PROJECT CONTACT. <br />3. DURING CONSTRUCTION AND INSTALLATION ANY DOORS AND WINDOWS CAN BE REPLACED WITH <br />EQUIVALENT BRAND AND MODEL PROVIDED IT MEETS ALL THE REQUIREMENTS FOR: <br />A. ENERGY PERFORMANCE; <br />B. EGRESS (IF APPLICABLE); <br />C. TEMPERED GLAZING (IF APPLICABLE); <br />D. SIZE (GLAZED AREA FOR NATURAL LIGHT ACCESS); <br />E. DOES NOT IMPACT THE STRUCTURAL PLAN. <br />4. PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR TO VERIFY MANUFACTURER'S <br />RECOMMENDATIONS <br />FOR, BUT NOT LIMITED TO, ROUGH OPENING SIZES AND INSTALLATION PRIOR TO COMMENCING THE <br />FRAMING. <br />5. PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR TO VERIFY ALL WINDOW DIMENSIONS, <br />MODELS, ROUGH OPENINGS IN THE FRAMING DURING CONSTRUCTION AND TEMPERED GLAZING <br />REQUIREMENTS PRIOR TO ORDERING DOORS AND WINDOWS FOR THE PROJECT. <br />6. ALL DOORS AND WINDOWS SHALL BE INSTALLED AND WATERPROOFED ACCORDING TO THESE PLANS <br />AND MANUFACTURER'S RECOMMENDATIONS. <br />7. ALL WINDOWS AND DOORS WITH GLAZING SHALL HAVE THE CERTIFYING LABEL ATTACHED, SHOWING <br />U-VALUE. THE LABEL SHALL BE NOT REMOVED UNTIL THE FINAL INSPECTION. <br />EMERGENCY ESCAPE (EGRESS) WINDOWS (CBC 1030 and CRC R310.1) <br />1. AT LEAST ONE WINDOW IN EACH BEDROOM IS REQUIRED TO MEET THESE REQUIREMENTS: <br />A. MINIMUM NET 5.7 SQFT OF OPENABLE AREA; <br />B. MINIMUM NET 20" CLEAR WIDTH WHEN OPEN; <br />C. MINIMUM NET 24": CLEAR HEIGHT WHEN OPEN; <br />D. MAXIMUM HEIGHT OF 44" FROM THE FINISHED FLOOR TO THE BOTTOM OF THE CLEAR OPENING; <br />TEMPERED GLAZING REQUIREMENTS (CBC 2406 and CRC 308.1, R308.4) <br />1. ALL DOORS WITH GLAZING SHALL BE OF TEMPERED GLAZING. <br />2. WINDOW GLAZING REQUIREMENTS ARE INDICATED ON THE FLOOR PLAN SHEET A2.0. <br />3. PROJECT CONTACT AND/OR THEIR LICENSED CONTRACTOR TO VERIFY TEMPERED GLAZING <br />REQUIREMENTS PRIOR TO WINDOW ORDERING AND INSTALLATION, SEE THE REQUIREMENTS BELOW. <br />4. TEMPERED GLAZING SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: <br />A. WITHIN A 2’ ARC OF EITHER THE EDGE OF A DOOR AND WHERE THE BOTTOM EXPOSED EDGE OF THE <br />GLAZING IS LESS THAN 60” ABOVE THE <br />WALKING SURFACE. <br />B. ADJACENT TO A BOTTOM STAIR LANDING WHERE GLAZING IS LESS THAN 36 INCHES ABOVE THE <br />LANDING AND WITHIN 60 INCHES <br />HORIZONTALLY OF THE LANDING. <br />C. ADJACENT TO STAIRS WHERE GLAZING IS LOCATED LESS THAN 36 INCHES ABOVE THE PLANE OF THE <br />ADJACENT WALKING SURFACE. <br />D. WITHIN A PORTION OF WALL ENCLOSING A TUB/SHOWER WHERE THE BOTTOM EXPOSED EDGE OF <br />THE GLAZING IS LESS THAN 60 INCHES <br />ABOVE THE STANDING SURFACE AND DRAIN INLET. <br />E. WITHIN 60 INCHES OF A TUB/SHOWER WHERE THE GLAZING IS LESS THAN 60 INCHES ABOVE THE <br />WALKING SURFACE. <br />F. ANY GLAZING MEETING ALL THE FOLLOWING CONDITIONS: <br />A. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET <br />B. EXPOSED BOTTOM EDGE IS LESS THAN 18 INCHES ABOVE THE FINISHED FLOOR <br />C. EXPOSED TOP EDGE IS GREATER THAN 36 INCHES ABOVE THE FINISHED FLOOR <br />D. WHERE A WALKING SURFACE IS WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING <br />5. WHERE REQUIRED, TEMPERED GLAZING (EXCEPT TEMPERED SPANDREL GLASS) SHALL BE <br />PERMANENTLY IDENTIFIED BY A MANUFACTURER MARKING THAT IS PERMANENTLY APPLIED AND <br />CANNOT BE REMOVED WITHOUT BEING DESTROYED (E.G. SAND BLASTED, ACID ETCHED, CERAMIC <br />FIRED, LASER ETCHED, OR EMBOSSED). A LABEL SHALL BE PERMITTED IN LIEU OF THE MANUFACTURER ’ <br />S DESIGNATION. <br />1. USE 5⁄8" GYPSUM BOARD THROUGHOUT THE BUILDING. <br />2. DRYWALL (SHEETROCK) IS THE INTERIOR FINISH MOST COMMONLY USED IN RESIDENTIAL <br />CONSTRUCTION. THE FOLLOWING GUIDELINES PERTAIN TO ITS <br />APPLICATION. SAME APPLIES TO WATERPROOF CEMENT WALL BOARDS. <br />3. WALLBOARD SHALL NOT BE INSTALLED UNTIL WEATHER PROTECTION FOR THE INSTALLATION IS <br />PROVIDED. <br />4. WHEN PRACTICAL, WALLBOARD SHOULD BE APPLIED FIRST TO THE CEILINGS, AND THEN TO WALLS. <br />SHEETS SHOULD BE BROUGHT INTO CONTACT BUT <br />NOT FORCED INTO PLACE. SPACES BETWEEN SHEETS SHOULD NOT EXCEED 1/4" AND TAPERED EDGES <br />SHOULD BE PLACED NEXT TO EACH OTHER WHEREVER POSSIBLE. <br />5. CUTOUTS FOR ELECTRICAL OUTLETS, PIPES, FIXTURES OR OTHER SMALL OPENINGS SHOULD BE CUT <br />OUT NEATLY WITH A MAXIMUM CLEARANCE OF 1/4". <br />IF THERE ARE ANY GAPS EXCEEDING 1/4", THEY MUST BE FILLED WITH TAPING COMPOUND AND <br />DRYWALL TAPE. <br />6. NAILING: <br />A. NAILS SHOULD BE DRIVEN SO THAT THE HEAD LIES IN A SMALL DIMPLE FORMED BY THE LAST BLOW <br />OF THE HAMMER. TAKE CARE NOT TO <br />FRACTURE THE BOARD WHEN NAILING. FRACTURES OF THE WALLBOARD CAUSED BY OVER DRIVING <br />MUST BE CORRECTED BY ADDITIONAL <br />NAILING. NAILS MUST BE BETWEEN 3/8" AND 1" FROM THE EDGES, AND NAILS ON ADJACENT EDGES <br />SHOULD BE OPPOSITE EACH OTHER. IF YOU <br />ARE USING THE SINGLE NAILING SYSTEM, THE NAILS SHOULD BE SPACED 7" ON CENTER ON THE <br />CEILINGS AND 8" ON CENTER ON THE WALLS. THE <br />DOUBLE NAILING SYSTEM IS ALSO PERMITTED. GROUPS OF TWO NAILS 2 - 2 1/2" APART ARE SPACED 12" <br />ON CENTER IN THIS SYSTEM. APPROVED <br />SCREWS MAY ALSO BE USED TO APPLY WALLBOARD. <br />B. SCREWS MUST BE PLACED 3/8" FROM THE END OR EDGES OF THE BOARD AND SPACED 12" ON <br />CENTER. SCREWS MUST BE USED FOR FASTENING <br />WALLBOARD AT POCKET DOORS. <br />C. FASTENERS AT THE TOP AND BOTTOM PLATES OF VERTICAL ASSEMBLIES, OR THE EDGES AND ENDS <br />OF HORIZONTAL ASSEMBLIES <br />PERPENDICULAR TO SUPPORTS, AND AT THE WALL LINE MAY BE OMITTED EXCEPT ON SHEAR- <br />RESISTING ELEMENTS OR FIRE RESISTIVE <br />ASSEMBLIES. ALL EDGES OF BRACED WALL PANELS AND FIREWALLS MUST BE NAILED TO FRAMING. <br />7. CORNERS: <br />A. ALL METAL REINFORCED CORNERS MUST FIT SNUGLY AGAINST WALLBOARD AND SHOULD BE NAILED <br />APPROXIMATELY 12" ON CENTER. <br />B. ALL "L" EDGE METAL TRIM SHOULD BE NAILED EVERY 6". PAPERBACK CORNER BEAD IS ACCEPTABLE <br />IF INSTALLED IN ACCORDANCE WITH THE <br />MANUFACTURER'S INSTRUCTIONS. <br />8. BATHROOM: <br />A. WATERPROOF CEMENT WALL BOARD SHALL BE USED IN THE BATHROOM AND BACKED WITH A VAPOR <br />BARRIER. <br />9. DRYWALL FASTENERS: <br />A. 6D CEMENT-COATED BOX NAIL, OR 1 7/8" DRYWALL NAIL <br />B. SCREWS SHALL BE LONG ENOUGH FOR THE FULL-DIAMETER PORTION TO PENETRATE INTO WOOD <br />FRAMING NOT LESS THAN 5/8 INCH AND <br />THROUGH METAL FRAMING NOT LESS THAN 1/4 INCH. <br />DOORS AND WINDOWS DOORS AND WINDOWS <br />SCHEDULE NOTES:SCHEDULE NOTES: <br />ROOM FINISHES NOTES:ROOM FINISHES NOTES: <br />DRYWALL:DRYWALL: <br />1. SEE FINISH SCHEDULE FOR FINISH INFORMATION ON SPECIFIC ROOMS. <br />2. BATHROOM TILES AND UNDERLAYMENT SHALL BE TYPE AND COLOR AS SELECTED BY PROJECT <br />CONTACT. <br />3. FLOOR PLANKS SHALL BE TYPE AND COLOR AS SELECTED BY PROJECT CONTACT. <br />4. TOP OF PLANK FLOOR TO BE FLUSH WITH TOP OF BATHROOM TILE FLOORING. <br />5. KITCHEN COUNTER-TOPS, SPLASH AND CABINETRY SHALL BE COLOR AND FINISH AS SELECTED BY <br />PROJECT CONTACT. <br />6. CONSULT PROJECT CONTACT FOR ALL INTERIOR TRIM INCLUDING, BUT NOT LIMITED TO, CEILING <br />MOLDINGS, LIGHTING MOLDINGS, WOOD BASES AND DOOR AND WINDOW CASINGS. <br />TYPICAL ASSEMBLIESTYPICAL ASSEMBLIES <br />CONTRACTOR TO VERIFY ALL SIZES IN THE FIELD PRIOR TO ORDERING DOORS. <br />GRAY LAMINATE ARCHITECTURAL <br />ROOFING SHINGLES <br />WOOD SIDING <br />MATCH EXISTING <br />0' <br /> <br />- <br /> <br />4 <br />" <br />ALL NEW EXTERIOR DOORS SHALL BE FRENCH MULTI-LITE DOORS. <br />ALL WINDOWS SHALL HAVE A 5.5 ” TRIM WIDTH, 2 ” SILL, AND 3.5 ” APRON <br />TO MATCH THE EXISTING BUILDINGS. <br />Window Schedule <br />Window Type Width Height Sill Height Finish Comments <br />01 3' - 0"4' - 0"3' - 0"VINYL U - FACTOR 0.3, SHGC 0.23 <br />02 2' - 0"3' - 0"4' - 0"VINYL U - FACTOR 0.3, SHGC 0.23 <br />03 2' - 6"4' - 0"3' - 0"VINYL U - FACTOR 0.3, SHGC 0.23 <br />WINDOW TYPESWINDOW TYPES <br />WINDOW SCHEDULEWINDOW SCHEDULE CONTRACTOR TO VERIFY ALL SIZES IN THE FIELD PRIOR TO ORDERING WINDOWS. <br />THE NEW WINDOWS WILL MATCH THE EXISTING WINDOW TRIM <br />FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS FOR <br />VERIFICATION OF THE BUILDING INSPECTOR.” 110.6(A)(5) <br />REV DATE REMARKS <br />1 10.03.2024 City Correction <br />2 06.25.2025 City Correction <br />OFF-WHITE COLOR MATCH THE PROPOSED WINDOWS FOR THE PRIMARY DWELLING <br />2 <br />2 <br />2