Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)174 @ 0 3281 (1.50")Passed (5%)--1.0 D + 1.0 L (All Spans) <br />Shear (lbs)112 @ 7"2310 Passed (5%)1.00 1.0 D + 1.0 L (All Spans) <br />Moment (Ft-lbs)142 @ 1' 7 1/2"1715 Passed (8%)1.00 1.0 D + 1.0 L (All Spans) <br />Vert Live Load Defl. (in)0.000 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 L (All Spans) <br />Vert Total Load Defl. (in)0.003 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 1.0 L (All Spans) <br />Lat Member Reaction (lbs)137 @ 3' 3"N/A Passed (N/A)1.60 1.0 D + 0.6 W <br />Lat Shear (lbs)102 @ 5"3696 Passed (3%)1.60 1.0 D + 0.6 W <br />Lat Moment (Ft-lbs)111 @ mid-span 1839 Passed (6%)1.60 1.0 D + 0.6 W <br />Lat Deflection (in)0.005 @ mid-span 0.108 Passed (L/999+)--1.0 D + 0.6 W <br />Bi-Axial Bending 0.11 1.00 Passed (11%)1.60 1.0 D + 0.6 W <br />Member Length : 3' 3" <br />System : Wall <br />Member Type : Header <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Lateral deflection criteria: Wind (L/360) <br />•A 0.3% decrease in the moment capacity has been added to account for lateral stability. <br />•Applicable calculations are based on NDS. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Floor Live Factored Accessories <br />1 - Trimmer - DF 1.50"1.50"1.50"153 22 174 None <br />2 - Trimmer - DF 1.50"1.50"1.50"153 22 174 None <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)End Bearing Points <br />Bottom Edge (Lu)End Bearing Points <br />Lateral Connections <br />Supports Stud Size Stud Material Connector Type/Model Quantity Nailing <br />Left 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 <br />Right 2X Douglas Fir-Larch Nails 8d (0.113" x 2 1/2") (Toe)2 <br />Dead Floor Live <br />Vertical Loads Location Tributary <br />Width <br />(0.90)(1.00)Comments <br />0 - Self Weight (PLF)0 to 3' 3"N/A 4.9 -- <br />1 - Uniform (PSF)0 to 3' 3"8"6.0 20.0 CLG <br />2 - Uniform (PSF)0 to 3' 3"5'17.0 -WALL <br />• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (8' 6"), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (95), Risk Category(II), Wind Zone (4), GCpi <br />(+/- 0.18), Effective Wind Area determined using full member span and trib. width. <br />• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. <br />Wind <br />Lateral Load Location Tributary Width (1.60)Comments <br />1 - Uniform (PSF)Full Length 8' 6"16.5 (7'/2)+5' <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />CLG, HDR-2 <br />1 piece(s) 4 x 6 DF No.2 <br />Page 124 of 213