My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HISTORIC-606 S Van Ness Ave Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Van Ness Ave
>
606 S Van Ness Ave Unit# 2
>
HISTORIC-606 S Van Ness Ave Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:00:55 AM
Creation date
2/24/2026 5:00:15 AM
Metadata
Fields
Template:
Plan
Permit Number
101123709
Full Address
606 S Van Ness Ave Unit# 2
Street Number
606
Street Direction
S
Street Name
Van Ness
Street Suffix
Ave
Unit Number
2
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
256
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)159 @ 9' 2 7/8"1641 (1.75")Passed (10%)--1.0 D + 1.0 L (All Spans) <br />Shear (lbs)138 @ 9"990 Passed (14%)1.00 1.0 D + 1.0 L (All Spans) <br />Moment (Ft-lbs)353 @ 4' 8 11/16"672 Passed (53%)1.00 1.0 D + 1.0 L (All Spans) <br />Live Load Defl. (in)0.120 @ 4' 8 11/16"0.301 Passed (L/903)--1.0 D + 1.0 L (All Spans) <br />Total Load Defl. (in)0.156 @ 4' 8 11/16"0.452 Passed (L/695)--1.0 D + 1.0 L (All Spans) <br />Member Length : 9' 3 5/8" <br />System : Ceiling <br />Member Type : Attic Joist <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 0/12 <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Floor/Ceiling <br />Live Factored Accessories <br />1 - Stud wall - DF 3.50"3.50"1.50"38 126 164 Blocking <br />2 - Stud wall - DF 1.75"1.75"1.50"37 122 159 Blocking <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)8' o/c <br />Bottom Edge (Lu)End Bearing Points <br />• Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. <br />Dead <br />Floor/Ceiling <br />Live <br />Vertical Load Location (Side)Spacing (0.90)(1.00)Comments <br />1 - Uniform (PSF)0 to 9' 3 5/8"16"6.0 20.0 CLG <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />CLG, CJ-9 <br />1 piece(s) 2 x 6 DF No.2 @ 16" OC <br />Page 163 of 213
The URL can be used to link to this page
Your browser does not support the video tag.