Laserfiche WebLink
LANDING <br />FOUNDATION PLAN SCHEDULE SYMBOL DESCRIPTIONS <br />SCALE: 1/4"=1'-0"FOUNDATION PLAN1 <br />INDICATES SHEARWALL TYPE <br />FOR SHEARWALL SCHEDULE <br />SEE 1/S1.21 <br />INDICATES MINIMUM <br />LENGTH OF SHEARWALL <br />SWXX <br />(#'-#") <br />INDICATES HOLDOWN TYPE X <br />INDICATES STEEL SECTION POST <br />MARK, ALL POSTS ARE <br />STEEL SECTION UNO ON PLANS <br />INDICATES WOOD POST MARK, <br />SEE POST SCHEDULE <br />C# <br />HDU <br />X <br /># <br />S#.##INDICATES SECTION <br />INDICATES SHEET NUMBER <br />INDICATES DETAIL <br />NUMBER ON THE SHEET <br />INDICATES TYP. 12" WIDE <br />FOUNDATION UNO ON PLAN <br />INDICATES HANGER <br />S#.## <br /># <br />INDICATES CALLOUT <br />#INDICATES REVISION ON <br />DRAWINGS <br />INDICATES VIEW# <br />S#.## <br />INDICATES LOAD BEARING WALL <br />BW <br />SOG REQUIREMENT NOTES <br />FOUNDATION PLAN NOTES <br />SW1 <br />(13'-10") <br />SW1 <br />(2'-8") <br />WS <br />P <br />(1 <br />7 <br />' <br />- <br />3 <br />" <br />) <br />SW <br />1 <br />(1 <br />3 <br />' <br />- <br />0 <br />" <br />) <br />WS <br />P <br />(2 <br />5 <br />' <br />- <br />9 <br />" <br />) <br />12" <br />12 <br />" <br />12" <br />12 <br />" <br />12" <br />12 <br />" <br />12" <br />12" <br />SEE NOTE A <br />SW1 <br />(8'-2")16 <br />" <br />1 <br />S1.01 <br />TYP <br />5 <br />S1.01 <br />TYP <br />1 <br />S1.01 <br />TYP <br />S1.01 <br />2 <br />REVIEW THE PLAN NOTES AND <br />PERFORM FIELD CONDITION <br />ASSESSMENT AND VERIFICATION <br />PRIOR TO COMMENCING THE WORK. <br />1. SOIL SUBGRADE REQUIREMENTS, ELEVATION AND SLOPING OF FOUNDATIONS AND SOG, AND <br />CONSTRUCTION REQUIREMENTS ARE NOT PART OF THIS SCOPE OF WORK OR THE LIABILITY OF THE <br />STRUCTURAL ENGINEER. <br />2. IF GEOTECHNICAL REPORT OR CIVIL DWGS. ARE AVAILABLE, CONTRACTOR SHALL REVIEW AND FOLLOW <br />THE GEOTECHNICAL REPORT AND CIVIL DWG. FOR THE CONSTRUCTION OF SOIL SUBGRADE AND SOG. <br />3. IN THE ABSENCE OF GEOTECHNICAL REPORT, OR CIVIL REPORT AND DWGS. THE DETAILS SHOWN ON <br />THESE DWGS. MAY BE CONSIDERED BY THE OWNER/GC ON THEIR OWN RISK. STRUCTURAL ENGINEER <br />SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES THAT MAY OCCUR DUE TO USING THESE <br />RECOMMENDATIONS.THESE ARE GENERAL RECOMMENDATIONS FOR THE CONSTRUCTION OF SOIL <br />SUBGRADE. THESE DETAILS DO NOT CONSIDER THE ACTUAL FIELD CONDITIONS. <br />3.1. SOG AND FOUNDATIONS SHALL BE CONTINUOUSLY SUPPORTED ON UNDISTURBED OR ENGINEERED <br />FILL SOIL. <br />3.2. THE AREA WITHIN THE SOG AND FOUNDATION WALLS SHALL HAVE ALL VEGETATION, TOP SOIL AND <br />FOREIGN MATERIAL REMOVED. <br />3.3. FILL MATERIAL SHALL BE FREE OF VEGETATION AND FOREIGN MATERIAL. THE FILL SHALL BE <br />COMPACTED TO ENSURE UNIFORM SUPPORT OF THE SOG, FOUNDATION, AND THE FILL DEPTHS SHALL NOT <br />EXCEED 24 IN FOR CLEAN SAND OR GRAVEL AND 8 IN FOR EARTH. <br />3.4. AT SOG AREA, REINFORCING STEEL SHALL BE SUPPORTED TO REMAIN IN PLACE FROM THE CENTER TO <br />MIDDLE FOURTH OF THE SLAB FOR THE DURATION OF THE CONC. PLACEMENT. <br />3.5. SCARIFY TOP 12" OR RECOMPACT 4' OVEREXCAVATION PRIOR TO TRENCHING FOR THE UTILITY <br />AND/OR FOUNDATION. 90% COMPACTION REPORT IS REQUIRED AT THE OF FOUNDATION INSPECTION. <br />DAMP PROOFING, BASE COURSE AND PRE-SATURATION ARE REQUIRE. <br />3.6. PROVIDE 5" SLAB ON GRADE REINFORCED WITH #4 AT 18" ON CENTERS EACH WAY OVER 4" BASE OF <br />1 <br />2" OR LARGER CLEAN AGGREGATE WITH 10 MIL VAPOR RETARDER IN DIRECT CONTACT WITH CONCRETE. <br />SLAB SHAL BE TIED-IN TO CONTINUOUS 12" WIDE x 24" (MINIMUM EMBEDMENT INTO FIRM SOIL) <br />FOUNDATION. <br />4. PROVIDE CONTROL JOINTS AT CL. OF CONC. OR STEEL COLUMNS IF NO CONSTRUCTION JOINTS OCCUR. <br />5. CONTRACTOR TO SUBMIT A JOINTING PLAN TO ARCHITECT FOR REVIEW. <br />6. THE TOP SURFACE OF FOUNDATIONS SHALL BE LEVEL ,UNO ON ARCH. DWG. <br />7. THE BOTTOM SURFACE OF FOUNDATION AND SOG SHALL NOT HAVE A SLOPE EXCEEDING ONE UNIT VER. <br />IN 12 UNITS HOR. <br />8. UNO ON PLANS OR TYPICAL DETAILS, NO HOR. CONSTRUCTION SHALL BE PERMITTED IN THE <br />FOUNDATIONS. ALL OTHER CONSTRUCTION JOINTS SHALL BE SUBMITTED TO SEOR AND ARCH FOR <br />REVIEW. <br />POST SCHEDULE UNO ON PLAN <br />MARK POST SIZE <br />C44 4x4 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />HDU <br />2HDU <br />2 <br />C44 <br />C44 <br />HDU <br />2 <br />HDU <br />2 <br />HDU <br />2 <br />C44 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />HDU <br />2C44 <br />C44 <br />HDU <br />2 <br />HDU <br />2 <br />C44HDU <br />2 <br />HDU <br />2 <br />C44 <br />C44HDU <br />2 <br />12 <br />" <br />1 <br />A <br />B <br />C <br />D <br />2 3 4 <br />NOTE A: <br />5" SOG W/#4@18"O.C. EACH WAY. SEE SOG REQUIREMENT NOTES FOR CAPILLARY <br />BREAK REQUIREMENTS. <br />12 <br />" <br />LANDING SEE DETAIL 9/S1.01 <br />C44 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />1 . T HES E D R A W I N G AR E BASE D O N T HE B EST A VAI L AB L E SO U R C E S AND D O N O T A DD R ES S T HE F IELD <br />CONDITIONS. THE CONTR ACTOR SHALL V ERIFY ALL FIELD CONDITIONS AND ALL EXISTING STRUCTURAL <br />E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y <br />DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR <br />AND SEO R . N O W OR K SHAL L BE P E RFOR MED IN T HE AFF E CT ED A REAS UNTIL TH E DIS CR EP ANC I E S AR E <br />RESOLVED. <br />2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS SHALL <br />BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR WALLS, <br />BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY IDENTIFIED. <br />3 . CO NT R A C T O R I S S O L E L Y R E S P O NS IB L E F O R P R O T E C T I O N O F A L L ST R U C T U R AL, N O N S T R U C T UR A L , <br />ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED <br />FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR <br />SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR OWNER. <br />4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN <br />CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER <br />DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS <br />INTO THE SHOP DRAWINGS AND FIELD WORK. <br />5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND <br />LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, <br />WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND SHALL <br />NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM OTHER <br />PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. <br />6. FOR CONSTRUCTION NOTES AND TYPICAL SYMBOLS DESCRIPTIONS, SEE S0 SERIES SHEETS. <br />7. FOR TYPICAL DETAILS, SEE S1 SERIES SHEETS. DETAILS AND SCHEDULES INDICATED AS 'TYPICAL' MAY <br />NOT BE SPECIFICALLY REFERENCED ON DRAWINGS. DETERMINE WHERE EACH TYPICAL DETAIL OR <br />SCHEDULE APPLIES BEFORE PROCEEDING WITH WORK. <br />8. SEE ARCH./CIVIL DWGS. FOR CONCRETE SLAB ELEVATIONS, DEPRESSIONS, SLOPES, OPENINGS, CURBS, <br />DRAINS, TRENCHES, SLAB EDGE LOCATIONS, ETC., AND FOR WALL OVERALL DIMENSIONS, LOCATIONS OF <br />OPENINGS, ETC., NOT INDICATED ON STRUCTURAL DWGS. <br />9. HOLD-DOWNS& ANCHORS HARDWARE MUST BE SECURED IN PLACE PRIOR TO CALLING FOR FOUNDATION <br />INSPECTION. WET SETTING ANCHORS IS PROHIBITED. <br />10. APPROVED PLATE WASHERS SHALL BE USED FOR HOLD-DOWN CONNECTOR BOLTS INTO WOOD FRAMING. <br />HOLD-DOWNS SHALL BE FINGER TIGHT AND 1/2 WRENCH TURN JUST PRIOR TO COVERING WALL FRAMING. <br />11. STANDING WATER SHALL BE REMOVED FROM THE FOUNDATION EXCAVATIONS PRIOR TO THE CONCRETE <br />PLACING. <br />12. UNO IN ARCH./CIVIL DWGS. SURFACE OUTSIDE THE HOUSE NEEDS TO HAVE 5% SLOPE (UNPAVED <br />SURFACE) & 2% SLOPE (PAVED SURFACE) AWAY FROM THE STRUCTURE. <br />13. ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT-DIPPED <br />ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. <br />14. MINIMUM EDGE DISTANCE FOR ANCHOR BOLTS SHALL BE 1-3/4". ALL ANCHOR BOLTS SHALL INCLUDE A <br />MINIMUM 0.229"X3"X3" STEEL PLATE WASHER. THE HOLE IN THE PLATE WASHER SHALL BE PERMITTED TO <br />BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16" LARGER THAN THE BOLT DIAMETER AND A SLOT <br />LENGTH NOT TO EXCEED 1-3/4", PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE <br />WASHER AND THE NUT. THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM <br />PLATE ON THE SIDE(S) FOR SHEATHING WITH SHEAR DESIGN VALUES EXCEEDING 400PLF. <br />15. THE FOUNDATION PLAN SHOWS THE GENERAL LAYOUT OF THE FOUNDATION. FOR LOCALIZED SIZE <br />CHANGES AT THE HOLD-DOWNS, REFER TO TYPICAL DETAILS. AT ALL HOLD-DOWN LOCATIONS, <br />FOUNDATION SHALL BE CONSTRUCTED WITH THE DIMENSIONS SPECIFIED IN TABLE FOR HOLD-DOWN <br />ANCHOR SCHEDULE SEE SHEET S1.01. <br />16. ALL WOOD MEMBERS IN CONTACT WITH MASONRY AND CONCRETE SHALL BE PRESSURE-TREATED AND <br />CONFORM TO THE REQUIREMENT OF "AWPA U1" FOR CATEGORY UC4A OR BETTER. <br />17. WOOD AND WOOD BASED MATERIALS USED RAISED FLOOR SYSTEMS INCLUDING JOISTS AND BEAMS <br />SHALL CONFORM TO THE REQUIREMENTS OF "AWPA U1" FOR CATEGORY UC3B OR HIGHER. <br />18. NO HORIZONTAL COLD JOINTS OTHER THAN THE LOCATIONS SHOWN ON THESE DRAWINGS SHALL BE <br />PERMITTED IN FOUNDATION CONSTRUCTION. ALL CONSTRUCTION JOINTS SHALL BE SUBMITTED TO SEOR <br />FOR REVIEW. <br />19. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED <br />NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLKG SHALL <br />BE PROVIDED AT PLYWD JOINTS FOR ALL WALLS. <br />20. SPECIAL SOIL CONDITIONS AND PROPERTIES SUCH AS LIQUEFACTION ZONES; ADJACENT TO OR WITHIN <br />AREAS PRONE TO LANDSLIDE, SLOPED LOTS GREATER THAN 1 UNIT VERTICAL UNITS HORIZONTAL ARE NOT <br />INCLUDED IN THIS SCOPE OF WORKS AND NOT CONSIDERED FOR FOUNDATION DESIGN. OWNER SHALL <br />HIRE A SOIL ENGINEER TO VERIFY THESE CONDITIONS AND THEIR EFFECTS ON STRUCTURAL ELEMENTS. <br />21. CONSTRUCTION BELOW THE RAISED FLOOR AND AT CRAWL SPACE INCLUDING LUMBERS AND TIMBERS <br />SHALL BE GRADE 1 OR BETTER , JOISTS & BEAM THAT ARE AT LEAST 18" ABOVE GROUND SHALL BE <br />CATEGORY 3B OR HIGHER AND POSTS, SILL PLATES AND BEAMS AND JOISTS LESS THAN 18" ABOVE THE <br />GROUND SHALL BE CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. <br />22. ALL CRIPPLE WALLS SHALL BE BRACED. <br />23. ALL TOP AND BOTTOM CONTINUAL/ LONGITUDINAL BARS IN STRIP FOUNDATIONS SHALL HAVE <br />STANDARD HOOKS AT THE ENDS. <br />24. ALL TOP AND BOTTOM DISCONTINUED/ LOCAL BARS ( IN BOTH DIRECTIONS ) AT THE PAD/ <br />ISOLATED FOUNDATIONS SHALL HAVE STANDARD HOOKS AT THE ENDS. <br />25. ALL SOG BARS SHALL HAVE STANDARD HOOKS AT THE ENDS. <br />26. FOR DRAINAGE LAYOUT AND REQUIREMENTS, SEE ARCHITECTURAL/CIVIL DRAWINGS. DRAINAGE IS NOT <br />INCLUDED IN STRUCTURAL ENGINEER'S SCOPE OF WORK. <br />27. WHERE THE STEEL COLUMNS ARE EXPOSED TO WEATHER, BASE PLATES AND COLUMNS UP TO 12" ABOVE <br />THE CONCRETE SLAB SHALL BE COATED WITH MIN. 2 COATS OF MACROPOXY 646. <br />28. ALL PERMANENT STEELS IN CONTACT WITH WEATHER SHALL BE PROTECTED FOR CORROSION. <br />29.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL <br />OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO <br />SEOR. <br />30. FOR ALL BASE PLATES AND STEELS THAT ARE OUTSIDE OR UNDER GROUND, APPLY MIN. 2 COATS OF <br />MACROPOXY 646 WITH MINIMUM 8 MILS THICKNESS. <br />31. THE LOCATION, DIMENSIONS, AND SPECIFIC REQUIREMENTS FOR MECHANICAL EQUIPMENT PADS, <br />INCLUDING HEAT PUMP UNITS AND CONDENSERS, SHALL BE COORDINATED BY THE ARCHITECT WITH THE <br />MECHANICAL ENGINEER, EQUIPMENT MANUFACTURER, AND OTHER RELEVANT DISCIPLINES. FINAL PAD <br />DIMENSIONS, CLEARANCES, ANCHORAGE REQUIREMENTS, AND EQUIPMENT LOADS SHALL BE PROVIDED BY <br />THE MECHANICAL ENGINEER AND/OR MANUFACTURER. <br />32. THE STRUCTURAL ENGINEER OF RECORD (SEOR) SHALL PROVIDE THE STRUCTURAL DESIGN OF THE PAD <br />(E.G., THICKNESS, REINFORCEMENT) BASED SOLELY ON THE MECHANICAL LOADING AND LOCATION <br />INFORMATION FURNISHED BY OTHERS. THE SEOR ASSUMES NO RESPONSIBILITY FOR DETERMINING <br />EQUIPMENT LOCATION, UTILITY COORDINATION, ACCESSIBILITY, SERVICE CLEARANCE, VIBRATION <br />ISOLATION, OR CONFORMANCE WITH MECHANICAL/ELECTRICAL CODES. <br />33. ANY CHANGE IN EQUIPMENT WEIGHT, CONFIGURATION, OR LAYOUT SHALL BE COMMUNICATED TO THE <br />SEOR FOR VERIFICATION OF STRUCTURAL ADEQUACY PRIOR TO CONSTRUCTION. <br />C44HDU <br />2 <br />MI <br />N <br />. <br /> <br />3 <br />' <br />- <br />0 <br />" <br />UN <br />O <br /> <br />O <br />N <br /> <br />H <br />D <br />U <br /> <br />D <br />E <br />T <br />A <br />I <br />L <br />FOUNDATION <br />WIDENING AT <br />HOLD-DOWNS(TYP.) <br />SEE HDU DETAIL <br />HDU <br />2 <br />C44 <br />SW1 <br />(8'-6") <br />C44 <br />W/B <br />C <br />4 <br />0 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />1 <br />DATE: <br />P.M.: <br />DRAWN BY: <br />JOB NO.: <br />30211 Avenida de las Banderas, Suite 200, Rancho Santa <br />Margarita, California, 92688 <br />909-257-7040 WWW.BNDESIGNBUILDINC.COM <br />THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF BN <br />DESIGN BUILD AND SHALL NOT BE USED FOR ANY OTHER WORK <br />EXCEPT BY AGREEMENT WITH BN DESIGN BUILD. <br />D E SI GN <br />B U I L D <br />CNI <br />UNIT 2, 606 S VAN <br />NESS AVE, <br />SANTA ANA, <br />CA 92701 <br />ACCESSORY <br /> DWELLING <br /> UNIT <br />REV DATE REMARKS <br />M.A. <br />ISSUED FOR PERMIT12.17.20240 <br />07.13.2025 <br />20241149 <br />ISSUED PER CITY COMMENT07.13.20251 <br />S2.01 <br />FOUNDATION PLAN <br />07/15/2025 <br />EXP. 06-30-2026