My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FLOOD ZONE - 4610 W Melric Dr & 406 S Andres Pl - Plan
PBA
>
Building
>
ProjectDox
>
A
>
Andres Pl
>
406 S Andres Pl
>
FLOOD ZONE - 4610 W Melric Dr & 406 S Andres Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:00:54 AM
Creation date
2/24/2026 5:00:16 AM
Metadata
Fields
Template:
Plan
Permit Number
101124032
Full Address
406 S Andres Pl
Street Number
406
Street Direction
S
Street Name
Andres
Street Suffix
Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />Planning and Building Agency <br />SM, = F,,S, = 1.593 (for the short period of 0.2 second) <br />SM1 = F,Si = null* (for the 1-second period) <br />• Design Spectral Response Accelerations: <br />SD, = 2/3 SM, = 1.062 (for the short period of 0.2 second) <br />SD1 = 2/3 SK = null* (for the 1-second period) <br />• PGA = 0.568 <br />* Please see ASCE 7-16, Section 11.4.8. <br />Please see APPENDIX C for additional seismic parameters, as needed. <br />Approved <br />FOR PERMIT ISSUANCE <br />Master ID: <br />Date: <br />Note: In general, the structural consultant of record for this project should review the <br />seismic parameters provided in this report and the 2022 CBC to evaluate the seismic <br />design. Final selection of design coefficients should be made by the structural consultant <br />based on the local laws and ordinances, expected structure response, and the desired level <br />of conservatism. <br />The civil/structural design engineer should consult with the project geotechnical <br />consultant, if additional geotechnical information is needed for structural seismic design. <br />Faults <br />No active faults are known to exist within or near the site. The probability of primary <br />surface rupture or deformation at the site is, therefore, considered very low. <br />The site is not designated to be located within the Special Studies/Earthquake Zone under <br />the Alquist-Priolo Special Studies Act. <br />Liquefaction Potential <br />As previously mentioned, for conservative purposes, the subject site is assumed to be <br />subject to the liquefaction. Therefore, the owner(s) of this property should be aware of <br />the risks associated with the potential liquefaction such as structural distress due to the <br />potential differential settlement caused by the potential liquefaction. <br />As previously mentioned, for conservative purposes, a strengthened / stiffened <br />foundation system (having thicker slabs with more reinforcements and deeper and <br />wider footings with more reinforcement as recommended in this report) should be <br />used for support of the proposed structure. <br />Page 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.