ELECTRICAL NOTES per 2019 California Electrical Code
<br />A. PANEL LOCATIONS
<br />B. NON-METTALIC SHEATED CABLE (CEC 334)
<br />C. CIRCUITS AND RECEPTACLES
<br />D. LIGHTING (CEC 210.70)
<br />E. FANS
<br />F. SMOKE ALARMS
<br />LIGHTING NOTES:
<br />NOTES:
<br />BATHROOM EXCHAUST FANS SEC.4.506.4 MECHANICAL EXCHAUST FANS WHICH EXCHAUST
<br />DIRECTLY FROM BATHROOM SHALL BE ENERGY STAR COMPLIANT, DUCTED TO TERMINATE OUTSIDE
<br />LATION SYSTEM.
<br />COVERS WHICH CLOSE WHEN THE FAN IS OFF THAT HAVE A MIN. INSULATION VALUE OF R-4.2
<br />THE BUILDING, AND CONTROLLED BY A READILY ACCESSIBLE HUMIDSTAT OR A WHOLE HOUSE VENTIL
<br />WHOLE HOUSE EXCHAUST FANS SEC.4.507.1 WHOLE HOUSE FANS SHALL HAVE INSULATED LOUVERS OR
<br />HEATING AND AIR CONDITIONING DESIGN SEC.4.507.2 SYSTEM SHALL BE SIZED,DESIGNED AND
<br />SPECIFIED ACCORDING TO ACCA,ASHRAE,OR EQUIVALENT DESIGN SOFTWARE OR METHODS.
<br />1. ALL (E) DIMENSIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL VERIFY ALL (E) DIMEN SIONS IN FIELD.
<br />5. LOCATION OF SMOKE DETECTORS (310.9.1) IN EACH SLEEPING AREA SHALL BE CENTRALLY LOCATED IN CORRIDOR (OR AREA) LEADING
<br />TO SLEEPING AREAS. SMOKE DETECTOR SHALL SOUND AN ALARM IN ALL SLEEPING AREAS.
<br />2. ALL EXTERIOR WINDOWS SHALL UTILIZE MULTIPLE GLAZED PANELS CONSISTING OF NOT LESS THAN DUAL PANE GLAZING.
<br />3. WINDOWS FOR EMERGENCY EGRESS OR RESCUE, SHALL BE OPERABLE FROM THE INSIDE TO PROVIDE A CLEAR OPENING OF 5.7 SQ.FT. MINIMUM. NET CLEAR
<br />OPENING WIDTH DIMENSION SHALL BE 20" AND 24" MINIMUM IN HEIGHT.SILL FINISHED HEIGHT NOT MORE THAN 44" ABOVE FINISHED FLOOR LEVEL.
<br />6. ALL GENERAL LIGHT AT KITCHEN AND BATH SHALL BE FLUORESCENT TYPE AND SHALL HAVE AN EF FICIENT OF NO LESS THAN 40 LUMENS
<br />PER WATT.
<br />2. SHOWERS AND TUB-SHOWERS COMBINATION SHALL BE PROVIDED WITH SEPERATE CONTROL VALVES FOR PRESSURE BALANCE.THE THERMO STATIC MIXING
<br />VALVE SHALL BE TYPE U.P.C. 420.
<br />3. PLUMBING FIXTURES WITH THE FOLLOWING MAXIMUM WATER USAGE'S SHALL BE INSTALLED IN THE ADDITION,WHERE APPLICABLE,AND IN EXISTING BATHS
<br />WASHROOMS, KITCHENS, LAUNDRY,ETC,,,
<br />a) WATER SAVING SHOWERHEADS SHALL HAVE A MAXIMUM FLOW OF 1.8 GAL PER MIN. AT 80 PSI. (CPC 408.2)
<br />b) WATER SAVING SINK AND LAVATORY FAUCETS SHALL HAVE A MAXIMUM FLOW OF 1.5 GALLONS PER MIN.AT 60 PSI.
<br />c) WATER CLOSETS SHALL NOT EXCEED 1.28 GALLONS PER FLUSH.
<br />d) KITCHEN FAUCETS SHALL NOT EXCEED 1.8 GALLONS PER MINUTE AT 60 PSI.
<br />WARM AIR FURNACES ARE PROHIBITED IN BED ROOMS OR BATHROOMS UNLESS THEY ARE PROTECT VENT HEATER.
<br />12. GLAZING IN HAZARDOUS LOCATIONS SHALL BE TEMPERED.91.2406.4:
<br />A.INGRESS AND EGRESS DOORS
<br />B.PANELS IN SLIDING OR SWINGING DOORS
<br />C.DOORS AND ENCLOSURE FOR HOT TUB, BATH TUB SHOWERS (ALSO GLAZING IN WALL ENCLO SING THESE COMPARTMENTS WITHIN 5' OF STANDING
<br />SURFACE)
<br />D.IF WITHIN 2' OF VERTICAL EDGE OF CLOSED DOOR AND WITHIN 5' OF STANDING SURFACE.
<br />E.IN WALL ENCLOSING STAIRWAY LANDING
<br />F.GUARDS AND HANDRAILS.
<br />8. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLD WITH A MINIMUM FALL OF 6 INCHES WITHIN THE FIRST 10 FEET
<br />(R401.3)
<br />9. VEHICULAR ACCESS DOORS SHALL COMPLY WITH SECTION (R612.4).
<br />11. PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE
<br />OF NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA U1 FOR THE SPECIES, PRODUCT,PRESERVATIVE
<br />AND END USE. PRESERVATIVES SHALL BE LISTED IN SECTION 4 OF AWPA U1.
<br />12 PROVIDE ANTI GRAFFITI FINISH WITHIN THE FIRST 9 FEET ,MEASURED FROM THE GRADE,AT EXTERIOR WALLS AND DOORS EXCEPTION: MAINTENANCE OF
<br />BUILDING AFFIDAVIT IS RECORDED BY THE OWNER TO COVENANT AND AGREE WITH THE CITY OF LOS ANGE LES TO REMOVE ANY GRAFFITI WITHIN 7-DAYS
<br />OF THE GRAFFITI BEING APPLIED (6306).
<br />3. SHOWER AND TUB ENCLOSURES SHALL BE TEM PERED (CBC 2406.4) WINDOWS AT SHOWERS AND TUBS SHALL BE TEMPERED. USE WATERPROOF 70" HIGH
<br />SHOWER WALL WITH HIGH ABSORBENT FINISH (CBC 80.1.3)FLOORS AND WALLS IN WATER CLOSET COMPARTMENTS AND SHOWERS SHALL COMPLY WITH
<br />SECTION 807.1.1 THROUGH 807. 1.4 AND 807.2.
<br />A. FIXED AND OPERSBLE PANELS OF SWINGING, SLIDING AND BI-FOLD DOORS ASSEMBLIES.
<br />B. GLAZING IN A INDIVDUAL FIXED OROPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24" INCH ARC OR EITHER
<br />VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE.
<br />D. GLAZING IN RAILINGS.
<br />E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS. WHIRPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EDGE
<br />OF THE GLAZING IS LESS 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING.
<br />Panels shall not be located in the vicinity of easily ignitable material, such as clothes, or in bathroom ( CEC 240-24(D) ).
<br />1.Protected by rigid metal conduit,intermediate metal conduit,electrical metallic tubing,schedule 80 PVC Conduit, pipe,or other
<br />means when cable is exposed or subject to physical damage. (CEC 334.15(b) ).
<br />2.Protected by a 1/16 inch steel plate or sleeve,or be not less than 1-1/4 inch fromthe nearest edge of the framing member,When installed
<br />through framing members. Steel plates or sleeves are required on all double shear walls when cable is installed either through or
<br />parrallel to framing members (CEC 334.17 ).
<br />3.Protected by guard strip with 6 feet of attic when no permanent stairs or ladders are provided (CEC 334.23, 320.23).
<br />4.Protected by guard strips in entire attic when permanent stairs or ladders are provided. Access panels or doors from the second floor into the
<br />attic are cinsidered permanent access and guard strips are required in the entire attic.
<br />5.Have a bending raduis not less than 5 times the diameter of the cable (CEC 334.24) ).
<br />6.Supported at intervals not exceeding 4 1/2 feet and within 12" of every outlet box,cabinet or fitting (CEC 334.30) .
<br />1.Receptacles shall be installed so that no point along the floor line in any wall space is more than 6ft. from an outlet,including any wall space
<br />2 ft.wide or greater. Note: A fixed panel of a sliding glass door is considered wall space. (CEC 210.52(A) ).
<br />2.In kitchens,breakfast rooms,pantries,and dining rooms a minimum of 2-20A circuits shall be provided (CEC 210.11(c)(1) ). Counter
<br />space receptacles shall be GFCI (CEC210.8(A) ). and installed:
<br />At each wall counter space that is 12 in or greater (CEC 210.52(C)(1) );
<br />No more than 48 in oc. (CEC 210.52(C)(1);
<br />Maximum 24 in from the end of the counter (CEC 210.52(C)(1) ).
<br />Maximum 20 in above counter surface (CEC 210.52(C)(5) ).
<br />On island counter spaces (one receptacle min.)not more than 12 in below counter surface (CEC
<br />210.52.11(C)(5) EXCEPTION). An island with less than 12'" behind the range top of sink is con sidered as dividing the countertop
<br />into two seperate spaces (CEC210.52(C)(2) ).
<br />On peninsular counter spaces (one receptacle min.)not more than 12 in below counter surface (CEC 210.52(C)(5)
<br />Exception).
<br />3.Bathroom shall have a seperate 20A circuit (CEC210.11(C)(3) with at least one GFCI wall receptacle within 36 in of each basin (CEC
<br />210.8(A)(1); (CEC 210.52(D).
<br />4.Laundry rooms shall have a seperate 20A circuit with at least one receptacle shall be provided (CEC 210.11(C)(2) ).All receptacles within 6
<br />ft. of the sinkshall be GFC I (CEC 210.8.(A)(7) ).
<br />5.In garages,at least one GFCI receptacle shall be provided (CEC210.52.(G) ). All other garage recep tacle except those dedicated to an
<br />appliance or that are not accessible shall be GFCI.(CEC 210.8(A)(2).
<br />6.In hallway of 10 ft or more in length at least one receptacle shall be provided ( CEC 210.52(H) ).
<br />7.Outdoor outlets shall be GFCI (CEC 210.8(3) ).One outlet shall be installed at the front of the dwelling and one at the rear of the dwelling.Receptacles
<br />shall be accessible at grade level and not more than 6 1/2 ft above grade (CEC 210.52(E) ).
<br />8.All crawl space receptacle shall be GFCI (CEC 210.8(A)(4) ).
<br />9.All unfinished basement receptacles shall be GFCI unless they are not readily accessible or are service a dedicated appliances (CEC 210.8(A)(5) ).
<br />10.All receptacles with 6 ft of a wet bar shall be GFCI (CEC 210.8(A)(7) ).
<br />11. All receptacles on 15A or 20A branch circuits that supply family rooms,dining rooms,living rooms,parlors,
<br />libraries,dens,bedrooms,sunrooms,recreation rooms,closets, hallways, or similar rooms,or areas shall beprotected by combination-type Arc-fault
<br />Circuit Interrupters (AFCI),including switched outlets(CEC 210.12(B) ).
<br />12.All receptacles serving appliances or motors with a rating of 1 HP or 6 amps shall be on a seperate circuits.
<br />13.For HVAC equipment,a seperate 15A or 20A circuit with an accessible receptacle at the equipment shall be provided within 25 ft of the equipment
<br />(CEC 210.63).If located in an under floor area.The receptacle shall be GFCI (CEC 210.8(4) ).
<br />1.Switched lighting shall be installed in: from an outlet,including any wall space 2 ft.wide or greater. Note: A fixed panel of a sliding glass door
<br />All habitable rooms, Bathrooms,Hallways,and Stairways at each level.
<br />Garages
<br />At all outdoor entrances and exits.
<br />In all attics, under floor areas,utility rooms,and basement used for storage.
<br />Near HVAC equipment in attic,under floor areas,rooms or basements,with a
<br />switch at the access point.
<br />2.Lighting installed in a closet shall be a surface mounted or recessed flourescent fixture or a surface mounted incandescent fixture with
<br />completely enclosed lamps.surface incandescent lighting shall be installed a minimum of 12 in. from the nearest point of a storage space.
<br />Surface fluorescent lighting and recessed lighting shall be installed a minimum of 6 in. from the nearest point of a storage space (CEC
<br />410.8(D).
<br />In bathrooms containing tubs or showers,a fan capable of exhausting 50 cfm shall be installed (Energy Standards 150 (0).
<br />In new construction,smoke alarms shall recieve their primary power from the building wiring.The wiring shall be permanent and installed
<br />without a disconnecting switch other than those required for over current protection (CRC R314.4).
<br />2. BATHROOMS, GARAGES, LAUNDRY ROOMS, OR UTILITY ROOMS MUST HAVE FLUORESCENT OR HIGH EFFICACY LIGHTING,OR AN OCCUPANT
<br />SENSOR WITH A MANUAL-ON/OFF FEATURE MAY BE INSTALLED.
<br />3. BEDROOMS,LIVING ROOMS,FAMILY ROOMS,AND OTHER ROOMS USED FOR LIVING AND SLEEPING MUST HAVE FLUORESCENT OR HIGH
<br />EFFICACY LIGHTING,OR AN OCCUPANT SENSOR WITH A MANUAL -ON/OFF FEATURE OR DIMMER MAY BE INSTALLED.
<br />4. EXTERIOR LIGHTING MUST BE FLUORESCENT OR HIGH EFFICACY OR AN OCCUPANT SENSOR WITH AN INTEGRAL PHOTO CONTROL MAY
<br />BE INSTALLED.
<br />1. THE FLOW RATES FOR ALL NEW PLUMBING FIXTURES SHALL COMPLY WITH THE MAXIMUM FLOW RATE SPECIFIED IN SECTION 4.303.1
<br />2. WHEN THE SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, AND/OR OTHER OUTLETS CONTROLLED BU A SINGLE VALVE SHALL
<br />NOT EXCEED 2.0 GALLONS PER MINUTE AT 80 PSI, THE SHOWER SHALL BE DESIGNED TO ONLY ALLOW ONE SHOWERHEAD TO BE
<br />OPERATED AT A TIME.
<br />ROOF NOTES:
<br />ARCHITECTURAL PLAN NOTES:
<br />1. KITCHEN RANGE HOODS SHALL BE INSTALLED FOR COOKING FACILITIES WITH AN APPROVED FORCED-DRAFT SYSTEM OF VENTILATION VENTED TO THE
<br />OUTSIDE OF THE BUILDING. DUCTS USED FOR DOMESTIC KITCHEN RANGE VENTILATION SHALL BE OF METAL, OR OTHER APPROVED MATERIAL, AND SHALL
<br />HAVE SMOOTH INTERIOR SURFACES. DUCTS FOR DOMESTIC RANGE HOODS SHALL ONLY SERVE COOKING APPLIANCES. (CMC 504.3; 3:& 150.0 (o) 1G, 2B)
<br />KITCHEN NOTES:
<br />4. ELEMENTS SHOWN ON THIS PLAN ARE NEW UNLESS LABELED AS EXISTING "(E)" OR SHOWN ON THE EXISTING FLOOR PLAN.
<br />7. DOORS AND WINDOWS SHALL BE CENTERED ON WALLS AS SHOWN, UNLESS SPECIFICALLY DIMENSIONED.
<br />BATHROOM NOTES:
<br />1. BATHROOMS SHALL BE PROVIDED WITH MECHANICAL VENTILATION OF 50 CFM INTERMITTENT OR 20 CFM CONTINUOUS.
<br />4. BATHTUB AND SHOWER FLOORS, WALLS ABOVE BATHTUBS WITH A SHOWERHEAD, AND SHOWER COMPARTIMENTS SHALL BE FINISHED WITH A
<br />NONABSORBENT SURFACE EXTENDING TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR.
<br />5. ACCESS TO BATHROOM FIXTURES: WATER CLOSETS SHALL BE SET AT LEAST 15" FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION. THE CLEAR SPACE
<br />IN FRONT OF ANY WATER CLOSET SHALL BE NOT LESS THAN 24".
<br />9. SHOWER COMPARTMENTS SHALL HAVE A MINIMUM FINISHED INTERIOR OF 1,024 SQ. IN. AND SHALL BE CAPABLE OF ENCOMPASSING A 30"
<br />CIRCLE.
<br />7. SHOWER SHALL BE PROVIDED WITH MIXING VALVE THAT WILL PROVIDE SCALD AND THERMAL SHOCK PROTECTION IN ACORDANCE WITH ASSE 1016
<br />OR ASME A112.18.1/SCA B125.1. (CPC. 408.3)
<br />e) INSULATION OF DOMESTIC HOT WATER PIPING SHALL BE IN ACCORADNCE WITH CPC SECTION 609.11.1 ANS SECTION 609.11.2
<br />5. EXTERIOR LANDING OR FLOOR AT EXTERIOR DOORS SHALL BE A MAXIMUM OF 7-3/4" BELOW THE TOP THRESHOLD THE THE DOOR DOES NOT SWING OUT
<br />OVER THE LANDING OR FLOOR. IF DOOR SWINGS OUTWARD, A LANDING SHALL BE 1.5" MAXIMUM BELOW THE TOP OF THRESHOLD. LANDINGS AT DOORS
<br />SHALL HAVE A LENGTH MEASURED IN DIRECTION OF TRAVEL NOT LESS THAN 36". LANDINGS SHALL SLOPE AWAY FROM THE DWELLING AT 2% MAXIMUM
<br />(SLOPE.11.3)
<br />SAFETY GLAZING IS REQUIRED IN THE FOLLOWING LOCATIONS:
<br />6. SHOWER CONTROL - CONTROL VALVES AND SHOWERHEADS SHALL BE LOCATED ON THE SIDE OF SHOWER COMPARTMENTS OR OTHERWISE
<br />ARRANGED SO THAT THE SHOWERHEAD DOES NOT DISCHARGE DIRECTLY AT THE ENTRANCE OF THE COMPARTMENT SO THAT THE BATHER CAN
<br />ADJUST THE VALVES PRIOR TO STEPPING INTO THE SHOWER SPRAY (CPC 408.9)
<br />8. SHOWER THRESHOLD SHALL BE NO LESS THAN 2" ABOVE THE SHOWER DRAIN. THE FINISHED FLOOR OF THE RECEPTOR SHALL SLOPE UNIFORMLY
<br />FROM THE SIDES TOWARDS THE DRAIN NO LESS THAN1/4"" PER FOOT AND NO MORE THAN 1/2" PER FOOT (CPC408.5)
<br />10. BATHROOM AND EXHAUST FAN(S) SHALL BE OF THE FALLOWING.
<br />a. ENERGY STAR COMPLIANT
<br />b. BE DUCTED TO TERMINATE OUTSIDE THE BUILDING
<br />c. BE RATED FOR SOUND AT A MAXIMUM OF 3 ZONE
<br />d. SWITCHED SEPARATELY FROM LIGHTING.
<br />a. KITCHEN VENTED RANGE HOOD.
<br />i HERS VERIFICATION OF AIRFLOW AND SOUND RATING
<br />ii MINIMUM AIRFLOW OF 100 CFM
<br />iii MAXIMUM ZONE RATING. OF 3.0
<br />C. GLAZING IN AN INDIVUAL FIXED OR OPERABLE PANEL THAT MEET ALL OF THE FOLLOWING CONDITIONS:
<br />1) EXPOSED AREA OF AN INDIVUAL PANE GREATER THAN 9 SQUARE FEET.
<br />2) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR
<br />3) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR
<br />4) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING.
<br />A MINIMUM OF 50% OF THE LUMINARIES IN A KITCHEN MUST BE FLUORESCENT OR HIGH EFFICACY.
<br />PLUMBING NOTES:
<br />13. EMERGENCY ESCAPE AND RESCUE OPENINGS: BASEMENTS, HABITABLE ATTICS, AND EVERY SLEEPING ROOM SHALL BE PROVIDED WITH AN OPERABLE EMERGENCY
<br />ESCAPE AND RESCUE OPENING. THE BOTTOM OF THE CLEAR OPENING SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR. OPENINGS SHALL OPEN DIRECTLY
<br />INTO A PUBLIC WAY, OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY. WHEN LOCATED AT THE GRADE FLOOR, THE NET CLEAR OPENING SHALL BE AT
<br />LEAST 5 SQ. FT. ELSEWHERE, THE NET CLEAR OPENING SHALL BE AT LEAST 5.7 SQ. FT. THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24". THE MINIMUM NET
<br />CLEAR OPENING WIDTH SHALL BE 20". OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS, OR SPECIAL
<br />KNOWLEDGE. BARS, GRILLES, COVERS, SCREENS OR SIMILAR DEVICES ARE PERMITTED TO BE PLACED OVER EMERGENCY ESCAPE AND RESCUE OPENINGS, PROVIDED
<br />THE MINIMUM NET CLEAR OPENING SIZE COMPLIES AS DESCRIBED ABOVE. SUCH DEVICES SHALL BE RELEASABLE OR REMOVABLE FROM THE INSIDE WITHOUT THE
<br />USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR FORCE GREATER THAN THAT WHICH IS REQUIRED FOR NORMAL OPERATION OF THE ESCAPE AND RESCUE
<br />OPENING. SECURITY BARS (BURGLAR BARS) SHALL COMPLY WITH CALIFORNIA REFERENCED STANDARDS CODE (TITLE 24, PART 12) CHAPTER 12-3.
<br />14. WINDOW SILLS, FALL PROTECTION: WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72" ABOVE THE FINISHED GRADE OR SURFACE
<br />BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24" ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE
<br />WINDOW IS LOCATED. OTHERWISE, OPENINGS SHALL NOT ALLOW THE PASSAGE OF A 4" DIAMETER SPHERE, OR A CODE-COMPLIANT FALL PREVENTION OR
<br />OPENING LIMITING DEVICE SHALL BE PROVIDED.
<br />15. ATTIC ACCESS: AN ATTIC ACCESS SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. 30" MINIMUM HEADROOM IS REQUIRED
<br />ABOVE THE ACCESS OPENING. THE ROUGH-FRAMED OPENING SHALL BE AT LEAST 22" x 30". WHEN EQUIPMENT IS LOCATED IN THE ATTIC, THE ACCESS
<br />OPENING SHALL BE AT LEAST AS LARGE AS THE LARGEST COMPONENT OF THE EQUIPMENT.
<br />16. WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
<br />AND CARBON MONOXIDE ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS. (CRC R314.2.2 & R315.2.1) SMOKE ALARMS SHALL BE PROVIDED IN EACH
<br />BEDROOM, OUTSIDE EACH BEDROOM IN THE IMMEDIATE VICINITY AND ON EVERY LEVEL. (CRC R314.3) CARBON MONOXIDE ALARMS SHALL BE PROVIDED
<br />OUTSIDE EACH BEDROOM IN THE IMMEDIATE VICINITY AND ON EVERY LEVEL. (CRC R315.3) ALL SMOKE DETECTORS 10 YEARS OR OLDER SHALL BE REPLACED.
<br />1. RECESSED DOWNLIGHT LUMINAIRES IN CEILING . IN ADDITION TO COMPLYING WITH 150.0 (k) LUMINAIRIES RECESSED INTO CEILINGS
<br />SHALL MEET ALL OF OF THE FALLIWING REQUIREMENTS.
<br />a.BE LISTED, AS DEFINED IN SECTION 100.0, FOR ZERO CLEARANCE INSULATION CONTACT (IC) BY UNDERWRITERS LABORATORIES OR
<br />OTHER NATIONALLY RECOGNIZED TESTING/RATING LABORATORY: AND
<br />b.HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WITH AIR LEAKAGE LESS THAN 2.0 CFM AT 75 PASCALS WHEN TESTED IN
<br />ACCORDANCE WITH ASTM E283. AN EXHAUST FAN HOUSING SAHALL NOT BE REQUIERD TO BE CERTIFIED AIRTIGHT: AND
<br />c. BE SEALED WITH A GASKET OR KAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING, AND HAVE ALL AIR LEAK PATHS BETWEEN
<br />CONDITIONED AND UNCONDITIONED SPACES SEALED WITH A GASKET OR CAULK: AND
<br />d. SHALL NOT CONTAIN SCREW BASE SOCKETS.
<br />6. THE MINIMUM WIDTH OF HALLWAYS SHALL BE AT LEAST 3 FT.
<br />1. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLD DOORS.
<br />2. GLAZING IN A FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24" ARC OF THE DOOR IN A CLOSED
<br />POSITION, AND WHOSE BOTTOM EDGE IS LESS THAN 60" ABOVE THE WALKING SURFACE.
<br />3. GLAZING IN A FIXED OR OPERABLE PANEL MEETING ALL OF THE FOLLOWING CONDITIONS: THE EXPOSED AREA OF AN INDIVIDUAL PANE IS LARGER THAN 9
<br />SQ. FT.; AND THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 18" ABOVE THE FLOOR; AND THE TOP EDGE OF THE GLAZING IS MORE THAN 36" ABOVE THE
<br />FLOOR; AND A WALKING SURFACE IS WITHIN 36" OF THE GLAZING.
<br />4. ALL GLAZING IN RAILINGS.
<br />5. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM
<br />EXPOSED EDGE OF GLAZING IS LESS THAN 60" MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE.
<br />6. GLAZING IN WALLS AND FENCES ADJACENT TO INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING
<br />IS LESS THAN 60" ABOVE A WALKING SURFACE AND WITHIN 60" OF THE WATER'S EDGE.
<br />9. SAFETY GLAZING SHALL BE PROVIDED WITH A MANUFACTURER'S DESIGNATION OR LABEL AS REQUIRED BY THE CODE.
<br />10. SAFETY GLAZING REQUIRED TO BE PERMANENTLY MARKED (ETCHED) AS REQUIRED BY CRC R.308.1.
<br />8. GLAZING ADJACENT TO STAIRWAYS WITHIN 60" HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE EXPOSED SURFACE
<br />OF THE GLAZING IS LESS THAN 60" ABOVE THE NOSE OF THE TREAD.
<br />7. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36" HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE
<br />GLAZING IS LESS THAN 60" ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE.
<br />11. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY GLAZING COMFORMING TO THE HUMAN IMPACT LOADS OF SECTION R308.3
<br />(SEE EXCEPTIONS)
<br />(R308.4).
<br />1. ROOF ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH THE CODE AND THE APPROVED MANUFACTURER'S INSTALLATION INSTRUCTIONS SUCH
<br />THAT THE ROOF ASSEMBLY SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. FLASHINGS SHALL BE INSTALLED IN A MANNER THAT PREVENTS
<br />M0ISTURE FROM ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH M0ISTURE PERMEABLE MATERIALS AND AT INTERSECTIONS WITH
<br />PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE.
<br />2. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE PROVIDED BY VENTILATING
<br />OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATION OPENINGS SHALL BE SCREENED WITH A CORROSION-RESISTANT
<br />MESH HAVING 1/16" - 1/8" OPENINGS.
<br />3. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1 /150 OF THE AREA OF THE SPACE VENTILATED. REDUCTION TO 1/300 IS PERMITTED IF
<br />BETWEEN 50% AND 80% OF THE VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE, AT LEAST 3 FEET ABOVE
<br />EAVE OR CORNICE VENTS. AS BARRIER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. WHERE EAVE OR CORNICE VENTS ARE INSTALLED,
<br />INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF 1" SPACE SHALL BE PROVIDED BETWEEN ll-lE INSULATION AND THE
<br />ROOFSHEATHING AND AT THE LOCATION OF THE VENT.
<br />4. AN ALTERNATIVE, THE NET FREE CROSS-VENTILATING AREA MAY BE REDUCED TO 1/300 WHEN A CLASS I OR II VAPOR
<br />* KITCHEN
<br />MIN. 50% LUMINARIES TO BE HIGH EFFICACY ON SEPARATE SWITCH.
<br />* BATHROOMS & LAUNDRY ROOM ALL LUMINARIES SHALL EITHER BE HIGH EFFICACY OR SHALL BE CONTROLLED BY AN OCCUPANT SENSOR.
<br />* OTHER ROOMS ALL LUMINARIES SHALL EITHER BE HIGH EFFICACY OR SHALL BE CONTROLLED BY AN OCCUPANT SENSOR OR DIMMER. CLOSETS
<br />THAT ARE LESS THAN 70 SQ ARE EXEMPT FROM THIS
<br />REQUIREMENT.* OUTDOOR LIGHTING
<br />ALL LUMINARIES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINARIES OR
<br />SHALL BE CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR
<br />COMBINATION.* OCCUPANCY SENSORS MUST HAVE NO MANUAL OVERRIDE, 30 MINUTE MAXIMUM TIMER AND BE MICROWAVE/ULTRASONIC OR PASSIVE
<br />INFRA-RED TYPE OCCUPANCY SENSOR LAYOUT MUST BE SHOWN ON PLANS.
<br />* HIGH EFFICACY LUMINARIES MUST BE PIN BASED.
<br />* RECEPTACLES IN ALL ROOMS SHALL BE AFCI PROTECTED.
<br /> ALL RECEPTACLE OUTLETS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLE PER CEC 406.11.
<br />* RECESSED LIGHT FIXTURES INSTALLED IN A RATED CEILING SHALL BE RATED(IC),
<br />(AT) AIR TIGHT, AND GASKETED OR CAULKED BETWEEN THE HOUSING AND CEILING.
<br />Project number
<br />Date
<br />Drawn by
<br />Checked by
<br />THIS DESIGN AND DRAWINGS, ARE
<br />COPYRIGHT PROTECTED AND ARE
<br />THE EXCLUSIVE PROPERTY OF J&C BUILDERS INC,
<br />THEY SHALL BE
<br />NO USED, MODIFIED DUPLICATED IN
<br />WHOLE OR IN ANY MANNER, NOR
<br />ASSIGNED TO A THIRD PARTY WITHOUT
<br />THE WRITTEN AUTHORIZATION
<br />OF J&C BUILDERS INC.
<br />APPROVAL STAMP
<br />OWNER
<br />CONTACT PERSON
<br />Jose Zambrano
<br />1117 SANTA FE AVE. #100
<br />LONG BEACH CA 90813
<br />MOBILE:562 522 3549
<br />EMAIL:info@jchomebuilders.net
<br />DESIGNER
<br />J&C BUILDERS INC
<br />1117 SANTA FE AVE. #100
<br />LONG BEACH CA 90813
<br />MOBILE:562 522 3549
<br />EMAIL:info@jchomebuilders.net
<br />T-24
<br />CONSULTANTS
<br />J&C Builders
<br />05-E-01
<br />GENERAL NOTES
<br />0001
<br />909 S Pacific Ave,
<br />Santa Ana, CA 92703
<br />02-13-2025
<br />Convert 360 ft² garage
<br />+150 ft² Add for a total
<br />of 510 ft² ADU
<br />Juan Silva
<br />949-232-3265
<br />No.Description Date
|