Laserfiche WebLink
DINING <br />CL <br />O <br />S <br />E <br />T <br />BEDROOM <br />ELECTRICAL LIGHTING PLAN <br />SCALE: 1/4" = 1'-0" <br />KITCHEN <br />LIVING ROOM <br />BATH <br />S2 <br />S2 <br />S2 <br />S3 <br />S3 <br />50 CFM <br />PROPOSED MECHANICAL, PLUMBING <br />5. <br />6 <br /> <br />G <br />P <br />M <br />It/C <br />SCHEDULE <br />SYMBOL DESCRIPTION <br /> SUB PANEL <br /> LIGHT, CEILING MOUNTED <br /> LIGHT, WALL MOUNTED <br /> RECESSED LIGHT, CEILING MOUNTED <br />S1 SINGLE SWITCH <br />S2 DOUBLE SWITCH <br />S3 TRIPLE SWITCH <br /> SINGLE OUTLET, TAMPER RESISTANT <br /> DUPLEX OUTLET, TAMPER RESISTANT <br /> W/ ARC FAULT RESISTANT <br /> DUPLEX OUTLET, TAMPER RESISTANT <br /> W/ GROUND FAULT INTERRUPTER <br /> DUPLEX OUTLET GROUND FAULT <br /> INTERRUPTER W/ WATERPROOF <br /> AIR CONDITION-HEATER OUTLET/MINI SPLIT <br /> GAS LINE <br /> EXHAUST FAN 50 CFM <br /> BATTERY OPERATED SMOKE DETECTOR <br /> CARBON MONOXIDE DETECTOR <br /> INTERNET/CABLE OUTLET <br />TR <br />TR/AFP <br />TR/GFI <br />TR/GFI <br />WP <br />AC/H <br />GAS <br />SPECIAL NOTES: <br />1. CARBON MONOXIDE AND SMOKE ALARMS ARE <br />REQUIRED FOR ALTERATIONS, REPAIRS OR ADDITIONS <br />WHERE A PERMIT VALUATION EXCEEDS $1,000 (R314 & <br />R315) <br />2. CARBON MONOXIDE ALARMS SHALL BE PROVIDED IN <br />EXISTING DWELLINGS OR SLEEPING UNITS THAN HAVE <br />ATTACHED GARAGES OR FUEL BURNING APPLIANCES, <br />LOCATE SUCH ALARMS OUTSIDE OF EACH SEPARATE <br />DOWELING UNIT SLEEPING AREA IN THE IMMEDIATE <br />VICINITY OF THE BEDROOMS <br />3. SMOKE ALARMS SHALL BE INSTALLED IN EACH <br />SLEEPING ROOM AND OUTSIDE OF EACH SEPARATE <br />SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE <br />BEDROOMS. NEW CONSTRUCTIONS 120 VOLT WITH <br />BATTERY BACKUP OPERATED AND INTERCONNECTED. <br />EXISTING CONSTRUCTION BATTERY OPERATED <br />4. COMBINATION TYPE ARC FAULT CIRCUIT <br />INTERRUPTERS (AFCI) SHALL BE INSTALLED IN ALL <br />DWELLING UNIT FAMILY ROOMS, LIVING ROOMS, <br />BEDROOMS, CLOSET, HALLWAY AND SIMILAR <br />ROOMS/AREAS <br />5. ALL REQUIRED 15 20 AMPERE RECEPTACLES LISTED IN <br />SECTION 210.52 FOR DWELLING UNITS SHALL BE <br />LISTED TAMPER RESISTANT RECEPTACLES <br />6. SMOKE DETECTORS AND CARBON MONOXIDE <br />DETECTORS ARE TO BE INTERCONNECTED PER CRC <br />314.4 AND 315.5 <br />7. SMOKE DETECTORS AND CARBON MONOXIDE <br />DETECTORS SHALL RECEIVE THEIR PRIMARY POWER <br />FROM THE BUILDING WIRING AND WILL HAVE A <br />BATTERY BACKUP PER CRC 314.6 AND 3155.6 <br />DINING <br />CL <br />O <br />S <br />E <br />T <br />BEDROOM <br />CONVENIENCE OUTLET PLAN <br />SCALE: 1/4" = 1'-0" <br />KITCHEN <br />LIVING ROOM <br />BATH <br />AC/H <br />AC/H <br />GAS <br />TR,AFP <br />TR,AFPTR,AFP <br />TR,AFP <br />TR,AFP <br />TR,GFITR,GFI <br />TR,AFP <br />TR,GFI <br />TR,GFI <br />PROPOSED <br />50 CFM <br />TR,GFI <br />TR,GFI TR,GFI <br />5. <br />6 <br /> <br />G <br />P <br />M <br />SCHEDULE <br />SYMBOL DESCRIPTION <br />A - TANKLESS WATER HEATER 9.5 GPM, 199,900 BTU <br /> NAT. GAS, FOR 3 BATHROOM HOMES. <br />B - TANKLESS WATER HEATER 8.4 GPM, 157,000 BTU <br /> NAT. GAS, FOR 2-3 BATHROOM HOMES. <br />C - TANKLESS WATER HEATER 5.6 GPM, 150,000 BTU <br /> NAT. GAS, FOR 1-2 BATHROOM HOMES. <br />5.6 GPM <br />A - EXHAUST FAN 50-70 CFM, UP TO 70 SQ. FT.; <br /> VENTED TO OUTSIDE AIR <br />B - EXHAUST FAN 70-100 CFM, UP TO 100 SQ. FT.; <br /> VENTED TO OUTSIDE AIR <br />C - EXHAUST FAN 100 CFM UP, 100 SQ. FT.; UP; <br /> VENTED TO OUTSIDE AIR <br />50 CFM <br />CALIFORNIA ENERGY CODE 150 <br />>1500 <br />>1000 - 1500 <br />750 - 1000 <br /><750 <br />TABLE 150.0 G <br />KITCHEN RANGE HOOD AIRFLOW RATES (CFM) AND ASTM E3087 CAPTURE <br />EFFICIENCY (CE) RATINGS ACCORDING TO DWELLING UNIT FLOOR AREA AND <br />KITCHEN RANGE FUEL TYPE <br />SYMBOL DWELLING UNIT <br />FLOOR AREA (S.F.) <br />50% CE or 110 CFM <br />50% CE or 110 CFM <br />50% CE or 130 CFM <br />50% CE or 160 CFM <br />70% CE or 130 CFM <br />80% CE or 250 CFM <br />85% CE or 280 CFM <br />85% CE or 280 CFM <br />HOOD OVER <br />ELECTRIC RANGE <br />HOOD OVER NATURAL <br />GAS RANGE <br />CALIFORNIA ELECTRICAL CODE <br />OW <br />N <br />E <br />R <br />DR <br />A <br />W <br />I <br />N <br />G <br /> <br />T <br />I <br />T <br />L <br />E <br />PR <br />O <br />J <br />E <br />C <br />T <br />90 <br />7 <br /> <br />S <br /> <br />F <br />L <br />O <br />W <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />DE <br />N <br />N <br />O <br />X <br /> <br />M <br />A <br />N <br />A <br />G <br />E <br />M <br />E <br />N <br />T <br />, <br /> <br />L <br />L <br />C <br />25 <br />4 <br />9 <br />5 <br /> <br />R <br />O <br />D <br />E <br />O <br /> <br />C <br />I <br />R <br />C <br />L <br />E <br />, <br />LA <br />G <br />U <br />N <br />A <br /> <br />H <br />I <br />L <br />L <br />S <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />5 <br />3 <br />2024-A003 <br />06/12/2024 <br />S.A. <br />7/ <br />6 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />2 <br />: <br />5 <br />4 <br /> <br />P <br />M <br />1st Ver - 06/16/2025 <br />. <br />SCARLET <br />ALMIRANTE <br />DESIGNER <br />1 <br />2nd Ver - 06/28/20252 <br />A3.1 <br />ME <br />P <br /> <br />P <br />L <br />A <br />N <br />S <br /> <br />& <br /> <br />N <br />O <br />T <br />E <br />S <br />AS NOTED <br />DESIGNER <br />SCARLET