Laserfiche WebLink
PAGE # <br />NOTES <br />AS NOTEDSCALE: <br />DATE: <br />PHONE: 323-448-4682 <br />GE <br />N <br />E <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br />AT <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />90 <br />7 <br /> <br />D <br />I <br />A <br />N <br />N <br />E <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />04/28/2025 <br />A. <br />1. <br />2. <br />B. <br />1. <br />2. <br />3. <br />4. <br />a. <br />b. <br />c. <br />5. <br />6. <br />7. <br />8. <br />9. <br />a. <br />b. <br />c. <br />d. <br />e. <br />f. <br />g. <br />C. <br />1. <br />a. <br />b. <br />c. <br />2. <br />3. <br />4. <br />D. <br />1. <br />2. <br />a. <br />b. <br />3. <br />4. <br />5. <br />6. <br />a. <br />b. <br />c. <br />7. <br />a. <br />b. <br />c. <br />d. <br />8. <br />IN ADDITION TO CODE, THE FOLLOWING SPECIFICATIONS AND STANDARDS APPLY TO <br />STRUCTURAL LUMBER AND RELATED CARPENTRY WORK FOR PROJECT: <br />NFPA NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. <br />WCLIB GRADING RULES NO. 16 OR APPLICABLE WWPA GRADING RULES. <br />MATERIAL QUALITY SHALL BE CONSISTENT WITH DESIGN ASSUMPTIONS. <br />STRUCTURAL LUMBER SHALL BE DOUGLAS FIR-LARCH (UNO). DOC PS 20. <br />MEMBER SIZES SPECIFIED ARE NOMINAL. STRUCTURAL LUMBER SHALL BE FINISHED <br />S4S (UNO). <br />STRUCTURAL LUMBER SHALL BE GRADE MARKED IN ACCORDANCE WITH <br />REFERENCED GRADING STANDARDS (UNO). <br />MINIMUM GRADES SHALL BE AS REQUIRED BY APPLICABLE STANDARDS BUT AT <br />LEAST EQUAL TO THE FOLLOWING: <br />2X WALL STUDS ONLY -- CONSTRUCTION GRADE <br />OTHER STUDS, JOISTS AND RAFTERS -- NO. 2 <br />BEAMS, POSTS AND ALL OTHER STRUCTURAL LUMBER -- NO. 1 OR BETTER <br />HIGHER LUMBER GRADES SHALL BE USED WHERE INDICATED. <br />NAILS SHALL BE COMMON WIRE NAILS (UNO). <br />BOLTS SHALLS BE M.B. WITH STANDARD MALLEABLE IRON OR STEEL PLATE <br />WASHERS UNDER ALL BOLT HEADS AND NUTS BEARING ON WOOD (UNO). <br />CONNECTION HARDWARE SHALL BE AS CALLED FOR. ALTERNATE PRODUCTS SHALL <br />BE SUBSTITUTED ONLY WITH THE APPROVAL OF SAA AND BUILDING DEPARTMENT. <br />MACHINE NAILING SYSTEMS SHALL BE SUBJECT TO SATISFACTORY DEMONSTRATION <br />AND TO THE ACCEPTANCE OF SAA AND BUILDING DEPARTMENT. <br />THE CONTRACTOR SHALL MAKE APPROPRIATE SUBMISSIONS, INCLUDING <br />TECHNICAL DATA, IN SUPPORT OF ANY PROPOSED MACHINE NAILING SYSTEM ON <br />REQUEST. <br />HEADS OR TOPS OF NAILS OR OTHER MACHINE DRIVEN FASTENERS SHALL NOT <br />PENETRATE THE SURFACE OF THE WOOD MORE THAN WOULD BE NORMAL FOR <br />HAND DRIVING. <br />LUMBER DAMAGED BY OVERDRIVING SHALL BE REMOVED AND REPLACED AT <br />THE CONTRACTOR'S EXPENSE. <br />PERSISTANT OVERDRIVING SHALL BE SUFFICIENT CAUSE FOR REJECTION OF A <br />MACHINE NAILING SYSTEM. <br />EDGE DISTANCES FOR MACHINE DRIVEN FASTENERS SHALL BE AS REQUIRED <br />FOR HAND DRIVING AND BY APPLICABLE CODES AND STANDARDS AND SHALL BE <br />CONSISTENT WITH THE NAILING SYSTEM MANUFACTURER'S <br />RECOMMENDATIONS. <br />ACCEPTANCE OF A MACHINE NAILING SYSTEM SHALL BE SUBJECT TO <br />CONTINUED SATISFACTORY PERFORMANCE. <br />MACHINE NAILING SHALL NOT BE USED WITH PLYWOOD LESS THAN 3/8" THICK. <br />APPROPRIATE PRECAUTIONS SHALL BE TAKEN TO ASSURE DURABILITY: <br />WOOD EXPOSED TO MOISTURE OR EARTH SHALL BE TREATED FOR PROTECTION <br />AGAINST DECAY AND TERMITE ATTACK OR SHALL BE FOUNDATION GRADE <br />REDWOOD. THIS REQUIREMENT SHALL APPLY TO: <br />ANY WOOD EMBEDDED IN OR IN DIRECT CONTACT WITH CONCRETE OR <br />MASONRY. <br />ANY WOOD OTHER THAN WALL STUDS WITHIN ONE FOOT OF EARTH. <br />ANY FLOOR JOIST WITHIN 18" OF EARTH. <br />PRESSURE TREATMENT PROCESS SHALL BE APPROVED BY BUILDING DEPARTMENT <br />AND SAA. TREATMENT PROCESSES EFFECTING MATERIAL PROPERTIES SHALL NOT <br />BE USED ON STRUCTURAL LUMBER WITHOUT SAA'S WRITTEN APPROVAL. <br />ADDITIONALLY CUT ENDS OF LUMBERS MUST BE FIELD TREATED WITH AN <br />APPROPRIATE AGENT TO AVOID COMPROMISING DECAY RESISTENCE OF LUMBER. <br />LUMBER USED IN THE WORK SHALL BE KILN DRIED TO AVOID EXCESSIVE SHRINKAGE <br />OR WARPING. "GREEN" LUMBER WITH EXCESSIVE MOISTURE CONTENT SHALL NOT <br />BE USED IN THE WORK. <br />SUBFLOORS, ATTICS, PLENUMS, AND OTHER VOID SPACES SHALL BE <br />APPROPRIATELY VENTILATED. <br />QUALITY FRAMING PRACTICES SHALL BE EMPLOYED IN THE CONSTRUCTION: <br />WOOD COLUMNS AND POSTS SHALL BE SECURED IN POSITION AT TRUE END <br />BEARINGS DESIGNED TO PROTECT AGAINST DECAY OR OTHER DAMAGE. <br />STUDS FOR WALLS AND PARTITIONS SHALL BE AS REQUIRED BY APPLICABLE <br />STANDARDS OR SPECIFIC DETAILS, WHICHEVER ARE MORE RESTRICTIVE, BUT NO <br />LESS THAN: <br />2X4 AT 16" o.c. FOR ANY WALL OR PARTITION. <br />2X6 AT 16" o.c. FOR STUDS OVER 9'-0" HIGH, CARRYING COMBINED FLOOR LOADS <br />FROM MORE THAN ONE LEVEL OR EXTERIOR WALLS (UNO) <br />DOUBLE TOP PLATES MATCHING STUDS FOR SIZE AND GRADE SHALL BE PROVIDED <br />AT ALL WALLS (UNO). SPLICES IN PLATES, IF USED, SHALL BE STAGGERED NO LESS <br />THAN 4'-0" o.c. <br />4X6 OR BETTER HEADER BEAMS OR LINTELS SHALL BE PROVIDED AT ALL OPENINGS <br />IN WALLS AND PARTITIONS. <br />CONTINUOUS HORIZONTAL 2X FIRE BLOCKING OF DEPTH TO MATCH STUDS SHALL BE <br />PROVIDED AT FLOORS, CEILINGS, SOFFITS AND AT NO MORE THAN 8'-0" o.c. <br />VERTICALLY IN ALL STUD WALLS. <br />BORED HOLES IN STUDS SHALL BE PERMITTED ONLY WITHIN THE FOLLOWING <br />RESTRICTIONS: <br />HOLES SHALL NOT APPROACH WITHIN 3/4" OF EITHER EDGE OF THE STUD. <br />HOLES SHALL NOT OCCUR WIHIN 6" OF ANY OTHER BORED HOLE, CUT, NOTCH, <br />OR END OF THE STUD. <br />HOLE DIAMETER SHALL BE LIMITED TO 60% OF WIDTH AT NON-BEARING STUDS IN <br />INTERIOR PARTITIONS SUPPORTING ONLY THEIR OWN WEIGHT AND 40% OF <br />WIDTH AT ALL OTHER STUDS. <br />NOTCHING OF STUDS SHALL BE PERMITTED ONLY WITHIN THE FOLLOWING <br />RESTRICTIONS: <br />NOTCHES SHALL BE NEATLY MADE WITH PREDRILLED CORNERS AND WITHOUT <br />OVERCUTTING. <br />NOTCHES SHALL NOT OCCUR WITHIN 6" OF ANY OTHER NOTCH, CUT, BORED <br />HOLE, OR END OF THE STUD. <br />NOTCH DEPTH SHALL BE LIMITED TO 40% OF WIDTH AT NON-BEARING STUDS IN <br />INTERIOR PARTITIONS SUPPORTING ONLY THEIR OWN WEIGHT AND 25% OF <br />WIDTH AT ALL OTHER STUDS. <br />NOTCH WIDTH SHALL BE LIMITED TO TWICE MAXIMUM PERMITTED DEPTH BUT IN <br />NO CASE MORE THAN SIX INCHES. <br />ALL STUD WALLS SHALL BE BRACED BY ONE OF THE FOLLOWING METHODS: <br />STRUCTURAL LUMBER a. <br />b. <br />c. <br />d. <br />e. <br />10. <br />11. <br />12. <br />13. <br />14. <br />15. <br />16. <br />a. <br />b. <br />c. <br />17. <br />a. <br />b. <br />c. <br />18. <br />19. <br />20. <br />a. <br />b. <br />c. <br />21. <br />22. <br />a. <br />b. <br />c. <br />23. <br />24. <br />25. <br />26. <br />27. <br />28. <br />29. <br />30. <br />31. <br />a. <br />b. <br />c. <br />d. <br />32. <br />33. <br />1/2" GYPSUM BOARD SHEATHING WITH 5d COOLER NAILS AT 7" o.c. TO ALL <br />STUDS AND TOP AND BOTTOM PLATES AND AT 12" o.c. AT ALL OTHER STUDS. <br />EDGE BLOCKING NOT REQUIRED. <br />OTHER SHEAR RESISTING FINISH APPROVED BY BUILDING DEPARTMENT FOR <br />EQUAL OR GREATER SHEAR STRENGTH THAN ITEM (a) ABOVE. <br />1X6 LET IN DIAGONAL BRACING AT NO MORE THAN 25'-0" o.c. ALONG WALL <br />ANGLED TO CROSS AT LEAST FOUR STUD SPACES IN WALL HEIGHT, WITH 2-8d <br />NAILS AT EACH STUD AND AT TOP AND BOTTOM PLATES. <br />APPROVED STEEL STRAP BRACING SIMILAR TO ITEM (c) ABOVE. <br />5/16" PLYWOOD PANELS AT LEAST 4'-0" WIDE AND EXTENDING FULL HEIGHT OF <br />WALL AT NO MORE THAN 25'-0" o.c. WITH 6d NAILS AT 6" o.c. TO STUDS AT <br />VERTICAL SHEET EDGES AND TO TOP AND BOTTOM PLATES AND AT 12" o.c. AT <br />ALL OTHER STUDS. EDGE BLOCKING NOT REQUIRED. <br />BEAMS OR GIRDERS SUPPORTED BY HANGERS OR STRUCTURAL STEEL SHALL <br />HAVE AT LEAST 3" OF FIRM BEARING IN A DETAIL APPROVED BY SAA (UNO). <br />BEAMS OR GIRDERS SUPPORTED BY CONCRETE OR MASONRY SHALL HAVE AT <br />LEAST 4" OF FIRM BEARING ON SOUND MATERIAL (UNO). <br />BEAMS OR GIRDERS SUPPORTED BY TIMBER SHALL HAVE FULL BEARING ACROSS <br />THE SECTION OF THE POST, GIRDER OR OTHER SUPPORT (UNO). <br />JOISTS OR RAFTERS SUPPORTED BY METAL HANGERS SHALL HAVE AT LEAST 1%% <br />30 1/2" OF FIRM BEARING (UNO). <br />JOISTS OR RAFTERS SUPPORTED BY CONCRETE OR MASONRY SHALL HAVE AT <br />LEAST 3" OF FIRM BEARING ON SOUND MATERIAL (UNO). <br />JOISTS OR RAFTERS SUPPORTED BY TIMBER SHALL HAVE FULL BEARING ACROSS <br />THE WIDTH OF BEAMS OR GIRDERS OR THE TOP PLATES OF STUD WALLS OR <br />SHALL BE ALIGNED WITH AND FACE NAILED TO STUDS AND SUPPORTED BY A 1X4 <br />RIBBON STRIP (UNO). <br />STABILITY BRACING SHALL BE PROVIDED AT NO MORE THAN 10'-0" o.c. FOR <br />RAFTERS AND 8'-0" FOR JOISTS IN ONE OF THE FOLLOWING WAYS: <br />CONTINUOUS 2X3 CROSS BRIDGING. <br />CONTINUOUS FULL DEPTH BLOCKING. <br />APPROVED METAL BRIDGING. <br />STABILITY BRACING SHALL BE PROVIDED FOR JOISTS AND RAFTERS AT ALL <br />SUPPORTS IN ONE OF THE FOLLOWING WAYS: <br />CONTINUOUS FULL DEPTH BLOCKING. <br />FULL NAILING OF A HANGER APPROVED FOR ROTATIONAL RESTRAINT. <br />END NAILING TO A RIM JOIST OR RAFTER. <br />RAFTERS OR JOISTS WITH COMMON INTERIOR BEARINGS SHALL BE LAPPED AT <br />LEAST 4" OVER SUPPORT AND ATTACHED TO ONE ANOTHER WITH 3-16d NAILS. <br />FLOOR JOISTS UNDER PARTITIONS PARALLEL TO THEIR SPAN SHALL BE DOUBLED <br />(UNO). <br />DOUBLED JOISTS OR OTHER VERTICALLY LAMINATED MEMBERS SHALL BE <br />SECURELY INTERCONNECTED ALONG THEIR ENTIRE LENGTH. <br />FASTENERS SHALL BE PLACED AT TOP AND BOTTOM QUARTER POINTS OF <br />DEPTH AND STAGGERED. <br />FASTENERS FOR 2X MEMBERS LESS THAN 12" DEEP MAY BE 16d NAILS AT 12" <br />o.c. (UNO). <br />FASTENERS FOR OTHER MEMBERS SHALL BE 1/2" DIAMETER BOLTS AT 24" o.c. <br />(UNO). <br />STRUCTURAL FRAMING MEMBERS SHALL NOT BE NOTCHED WITHOUT SAA'S <br />SPECIFIC APPROVAL. <br />BORED HOLES IN JOISTS OR RAFTERS SHALL BE PERMITTED ONLY WITHIN THE <br />FOLLOWING RESTRICTIONS: <br />HOLES SHALL NOT APPROACH WITHIN 2" OF EITHER EDGE OF THE MEMBER. <br />HOLES SHALL NOT OCCUR WIHIN 12" OF ANY OTHER HOLE OR OF THE END OF <br />THE MEMBER. <br />HOLE DIAMETER SHALL BE LIMITED TO ONE-THIRD OF DEPTH. <br />END JOINTS IN ADJACENT BOARDS IN LUMBER SHEATHING SHALL BE SEPARATED <br />BY AT LEAST TWO SUPPORT SPACES AND AT LEAST TWO BOARDS SHALL <br />SEPARATE ANY TWO JOINTS ON THE SAME SUPPORT. <br />NAILS DRIVEN PERPENDICULAR TO GRAIN SHALL BE USED IN FAVOR OF TOE NAILS <br />WHENEVER POSSIBLE. <br />WHEN TOE NAILS MUST BE USED, THEY SHALL BE DRIVEN AT AN ANGLE OF <br />APPROXIMATELY THIRTY DEGREES TO THE FACE AND STARTED APPROXIMATELY <br />ONE-THIRD OF THEIR LENGTH FROM THE END OF THE PIECE. <br />IMPROPERLY INSTALLED TOE NAILS SHALL NOT BE CONSIDERED AS HAVING <br />STRUCTURAL VALUE AND MEMBERS DAMAGED BY IMPROPER TOE NAILING SHALL <br />BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE. <br />BOLT HOLES, INCLUDING THOSE AT SILL ANCHORS, SHALL BE NO LESS THAN 1/32" <br />AND NO MORE THAN 1/16" LARGER THAN THE NOMINAL DIAMETER OF THE <br />FASTENER (UNO). OVERSIZE BOLT HOLES SHALL BE SUFFICIENT CAUSE FOR <br />REJECTION OF THE WORK. <br />THE CONTRACTOR SHALL VERIFY AND RETIGHTEN ALL BOLTS PRIOR TO <br />APPLICATION OF FINISH OR TO OTHER CONSTRUCTION WHICH WOULD MADE THEM <br />INACCESSIBLE. <br />NEITHER BOLTS, LAG SCREWS NOR WOOD SCREWS SHALL BE HAMMERED OR <br />OTHERWISE DRIVEN INTO PLACE. DRIVING OF SUCH MEMBERS SHALL BE <br />SUFFICIENT CAUSE FOR REJECTION OF THE FASTENING. <br />FRAMING HARDWARE SHALL BE INSTALLED WITH PROPER SIZE, LOCATION AND <br />NUMBER OF FASTENERS IN ACCORDANCE WITH MANUFACTURER'S <br />RECOMMENDATIONS AND CONDITIONS OF RELEVANT APPROVALS. <br />SILL PLATES AT STUD WALLS SHALL BE PROPERLY DETAILED AND ANCHORED: <br />SILLS SHALL BE 3X MINIMUM (UNO). <br />SILLS BEARING ON MASONRY OR CONCRETE SHALL BE SECURED IN POSITION <br />WITH NO LESS THAN 1/2" ANCHOR BOLTS AT 48" o.c. MAXIMUM WITH AT LEAST 7" <br />EMBEDMENT INTO SOUND CONCRETE OR MASONRY GROUT. <br />SILL ANCHOR BOLTS SHALL BE PROVIDED WITHIN 9" OF EACH END OF EACH <br />PIECE AND NO PIECE SHALL HAVE LESS THAN TWO BOLTS. <br />SILL ANCHOR BOLTS SHALL BE ARRANGED TO AVOID INTERFERENCE WITH <br />FRAMING WHENEVER POSSIBLE. <br />WHERE GYPSUM BOARD, PLYWOOD OR OTHER STRUCTURAL SHEATHING IS <br />SPECIFIED IN THE STRUCTURAL DRAWINGS, JOINTS SHALL NOT BE TAPED OR <br />FINISH APPLIED UNTIL ATTACHMENT TO SUPPORTING FRAMING HAS BEEN <br />INSPECTED AND APPROVED. <br />WHERE PLASTER OR STUCCO IS SPECIFIED IN THE STRUCTURAL DRAWINGS, <br />APPLICATION SHALL NOT BEGIN UNTIL LATH TYPE AND ATTACHMENT TO <br />SUPPORTING FRAMING HAS BEEN INSPECTED AND APPROVED. <br />A. <br />1. <br />B. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />FOUNDATION EXCAVATION AND CONSTRUCTION SHALL BE ACCOMPLISHED IN A <br />MANNER CONSISTENT WITH DESIGN ASSUMPTIONS: <br />FOOTINGS SHALL BE FOUNDED NO LESS THAN TWO FEET (2'-0") BELOW LOWEST <br />ADJACENT FINISH GRADE, SLAB OR PAVEMENT AND BE EMBEDDED INTO NATIVE <br />SOIL OR CERTIFIED COMPACTED FILL. <br />ALL EXCAVATION AND GRADING OPERATIONS SHALL BE CONDUCTED IN ACCORDANCE <br />WITH REQUIREMENTS OF GOVERNING AUTHORITIES AND IN A MANNER CONSISTENT <br />WITH QUALITY CONSTRUCTION STANDARDS. <br />EXCAVATIONS SHALL BE LAID BACK OR SHORED AS REQUIRED FOR SAFETY AND <br />STABILITY AT ALL STAGES OF THE WORK. <br />ADEQUATE PROVISIONS FOR DRAINAGE AND REMOVAL OF RAINWATER, AND <br />GROUNDWATER IF PRESENT, SHALL BE INCORPORATED INTO TEMPORARY SLOPES <br />OR GRADED SURFACES IN ORDER TO PRESERVE STABILITY AND PROTECT <br />AGAINST ILLEGAL, DANGEROUS, UNSIGHTLY, OR OTHERWISE INAPPROPRIATE RUN- <br />OFF. <br />BACKFILL WHICH WILL SUPPORT STRUCTURAL LOADS SHALL BE PLACED IN LIFTS <br />AND COMPACTED TO AT LEAST 95% OF MAXIMUM DENSITY UNDER THE <br />SUPERVISION OF GEOTECHNICAL ENGINEER. <br />BACKFILL SHALL NOT BE PLACED AGAINST NEW RETAINING STRUCTURES UNTIL <br />THEY AND THEIR SUPPORTS HAVE ACHIEVED THEIR DESIGN STRENGTH UNLESS <br />APPROPRIATE TEMPORARY SUPPORTS ARE PROVIDED. <br />COMPACTION METHODS USED FOR BACKFILL BEHIND RETAINING STRUCTURES <br />SHALL TAKE SURCHARGE OF THOSE STRUCTURES INTO CONSIDERATION. <br />APPROPRIATE TEMPORARY SUPPORTS SHALL BE PROVIDED AS NECESSARY. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR TO THE SATISFACTION OF <br />OWNER, LANDLORD, ARCHITECT, BUILDING DEPARTMENT, AND SAA OF ANY <br />DAMAGE TO RETAINING STRUCTURES CAUSED BY PREMATURE BACKFILLING, <br />COMPACTION EFFORTS, OR OTHER CONSTRUCTION SURCHARGE. <br />CONCRETE SHALL NOT BE PLACED IN EXCAVATIONS CONTAINING STANDING <br />WATER WITHOUT PRIOR APPROVAL. REQUESTS FOR SUCH APPROVAL SHALL <br />INCLUDE DETAILED DESCRIPTION OF APPROPRIATE WET PLACEMENT <br />PROCEDURES THAT SHALL BE SUBJECT TO THE APPROVAL OF GEOTECHNICAL <br />ENGINEER, BUILDING DEPARTMENT, AND SAA AND WHICH, IF APPROVED, SHALL BE <br />STRICTLY FOLLOWED. <br />EXCAVATIONS AND FOUNDATIONS <br />A. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />B. <br />1. <br />2. <br />3. <br />4. <br />5. <br />C. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />IN ADDITION TO CODE, THE FOLLOWING SPECIFICATIONS AND STANDARDS APPLY TO <br />STRUCTURAL CONCRETE WORK FOR PROJECT: <br />ACI BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318). <br />ACI CODE OF STANDARD PRACTICE. <br />ASTM C33 FOR AGGREGATE (UNO). <br />ASTM C330 FOR AGGREGATE FOR STRUCTURAL LIGHTWEIGHT CONCRETE (AS <br />SPECIFIED). <br />ASTM C150 TYPE I OR II FOR CEMENT. ALL STRUCTURAL CONCRETE IN CONTACT <br />WITH SOIL SHALL BE MADE WITH TYPE II CEMENT. <br />ASTM C260 FOR AIR ENTRAINING ADMIXTURES WHERE SPECIFIED OR ADDED AT <br />CONTRACTOR'S OPTION. <br />ASTM C494 FOR WATER-REDUCING, RETARDING, ACCELERATING, WATER- <br />REDUCING AND RETARDING OR WATER-REDUCING AND ACCELERATING <br />ADMIXTURES WHERE SPECIFIED OR ADDED AT CONTRACTOR'S OPTION. <br />ASTM C618 FOR FLY ASH OR OTHER POZZOLANIC ADMIXTURES WHERE SPECIFIED <br />OR ADDED AT CONTRACTOR'S OPTION. NO MORE THAN 15% OF THE TOTAL <br />CEMENT CONTENT IN ANY STRUCTURAL CONCRETE MIX SHALL BE SUCH MATERIAL <br />(UNO). <br />ASTM C94 FOR READY-MIXED CONCRETE. ALL STRUCTURAL CONCRETE SHALL BE <br />DELIVERED TO THE SITE READY-MIXED. <br />STRUCTURAL CONCRETE SHALL BE OF SPECIFIED TYPES AND STRENGTHS AND OF <br />QUALITY COMPATIBLE WITH THE REQUIREMENTS OF THE WORK. <br />ALL STRUCTURAL CONCRETE SHALL HAVE AN ULTIMATE COMPRESSIVE STRENGTH <br />OF AT LEAST 3000 PSI AT THE AGE OF 28 DAYS (UNO). STRUCTURAL CONCRETE <br />FOR THIS PROJECT DESIGNED USING 2500 PSI BUT CONTRACTOR TO PLACE 3000 <br />PSI MATERIAL (NO SPECIAL INSPECTION REQUIRED). <br />ALL STRUCTURAL CONCRETE SHALL BE STONE TYPE WITH A FULLY CURED <br />DENSITY BETWEEN 140 AND 150 PCF (UNO). <br />STRUCTURAL LIGHTWEIGHT CONCRETE, WHERE SPECIFIED, SHALL HAVE A FULLY <br />CURED DENSITY BETWEEN 110 AND 120 PCF (UNO). <br />SLUMPS OF STRUCTURAL CONCRETE SHALL BE AS SMALL AS PRACTICAL FOR THE <br />INTENDED APPLICATION AND SHALL COMPLY WITH RECOMMENDATIONS OF <br />REFERENCED STANDARDS AND LIMITATIONS OF THE MIX DESIGN. <br />NO CONCRETE WITH MEASURED SLUMP GREATERTHAN SIX INCHES SHALL BE <br />USED IN THE WORKWITHOUT THE SPECIFIC WRITTEN APPROVAL OF SAA.SLUMP <br />MAY BE MEASURED AT POINT OF PLACEMENT. <br />GROUT AND DRYPACK SHALL BE TREATED AS STRUCTURAL CONCRETE AND SHALL BE <br />SUBJECT TO ALL APPLICABLE REQUIREMENTS OF THESE NOTES (UNO). <br />GROUT SHALL BE A HIGH-STRENGTH SHRINKAGE-COMPENSATING ("NONSHRINK") <br />CEMENTITIOUS MATERIAL OBTAINING AN ULTIMATE COMPRESSIVE STRENGTH OF <br />AT LEAST 5000 PSI ATTHE AGE OF 28 DAYS WHEN TESTED IN ACCORDANCE WITH <br />ASTM C109. <br />GROUT SHALL BE A PRE-ENGINEERED PRODUCT ACCEPTABLE TO BUILDING <br />DEPARTMENT AND SAA. <br />GROUT SHALL BE DELIVERED TO THE SITE PREMIXED IN MANUFACTURERS <br />ORIGINAL PACKAGING. ONLY WATER SHALL BE ADDED ON SITE. GROUT SHALL BE <br />PREPARED AND PLACED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />GROUT SHALL BE MIXED TO A UNIFORM FLUID CONSISTENCY, POURED INTO <br />FORMS AS REQUIRED, AND CHAINED OR RODDED TO ASSURE THAT ALL VOIDS ARE <br />FILLED. <br />GROUT CONTAINING METALLIC ADMIXTURES SHALL NOT BE USED WITHOUT THE <br />WRITTEN APPROVAL OF BOTH ARCHITECT AND SAA. <br />DRYPACK, WHERE SPECIFIED, SHALL BE GROUT MIXED TO A STIFF CLAY-LIKE <br />CONSISTENCY. CARE SHALL BE TAKEN TO ASSURE UNIFORMITY PRIOR TO <br />PLACEMENT. <br />EXISTING CONCRETE OR OTHER POROUS SURFACES AGAINST WHICH GROUT OR <br />DRYPACK IS TO BE PLACED SHALL BE MOISTENED TO PREVENT PREMATURE <br />DEHYDRATION OF THE MATERIAL. <br />INSPECTION REQUIREMENTS FOR STRUCTURAL GROUT AND DRYPACK SHALL BE <br />AS FOR STRUCTURAL CONCRETE EXCEPT THAT CUBES RATHER THAN CYLINDERS <br />MAY BE TAKEN FOR COMPRESSIVE STRENGTH TESTING. <br />CONSISTENCY, POURED INTO FORMS AS REQUIRED, AND CHAINED OR RODDED TO <br />ASSURE THAT ALL VOIDS ARE FILLED. <br />GROUT CONTAINING METALLIC ADMIXTURES SHALL NOT BE USED WITHOUT THE <br />WRITTEN APPROVAL OF BOTH ARCHITECT AND SAA. <br />DRYPACK, WHERE SPECIFIED, SHALL BE GROUT MIXED TO A STIFF CLAY-LIKE <br />CONSISTENCY. CARE SHALL BE TAKEN TO ASSURE UNIFORMITY PRIOR TO <br />PLACEMENT. <br />EXISTING CONCRETE OR OTHER POROUS SURFACES AGAINST WHICH GROUT OR <br />DRYPACK IS TO BE PLACED SHALL BE MOISTENED TO PREVENT PREMATURE <br />DEHYDRATION OF THE MATERIAL. <br />STRUCTURAL CONCRETE <br />D. <br />1. <br />2. <br />3. <br />4. <br />5. <br />E. <br />1. <br />2. <br />a. <br />b. <br />• <br />• <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />F. <br />1. <br />2. <br />3. <br />4. <br />5. <br />G. <br />1. <br />2. <br />3. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR MIX DESIGNS. <br />MIX DESIGNS FOR CONCRETE WITH SPECIFIED STRENGTH UP TO 2500 PSI MAY BE <br />BY SUPPLIER AND NEED NOT BE SUBMITTED FOR REVIEW PRIOR TO USE. <br />MIX DESIGNS FOR CONCRETE WITH SPECIFIED STRENGTH GREATER THAN 2500 PSI <br />SHALL BE BY A CALIFORNIA LICENSED CIVIL ENGINEER IN THE EMPLOY OF A <br />CERTIFIED INDEPENDENT TESTING LABORATORY ACCEPTABLE TO BUILDING <br />DEPARTMENT AND SAA. COSTS OF SUCH DESIGN SHALL BE BORNE BY THE <br />CONTRACTOR. <br />CALCIUM CHLORIDE OR OTHER ADMIXTURES CONTAINING CHLORIDE OTHER THAN <br />AS AN IMPURITY SHALL NOT BE USED IN STRUCTURAL CONCRETE WITHOUT THE <br />WRITTEN APPROVAL OF SAA. <br />COPIES OF EACH MIX DESIGN, BEARING THE SEAL AND SIGNATURE OF THEIR <br />DESIGNER AND ACCOMPANIED BY CERTIFIED RESULTS OF 7 AND 28 DAY TRIAL <br />BATCH CYLINDER TEST RESULTS, SHALL BE SUBMITTED TO BUILDING DEPARTMENT <br />AND SAA NO LESS THAN TWO WORKING DAYS BEFORE USE. <br />COPIES OF THE MIX DESIGN SHALL BE PRESENT AT BATCH PLANT AND JOB SITE <br />PRIOR TO USE. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING PROPER PREPARATIONS <br />PRIOR TO THE PLACEMENT OF STRUCTURAL CONCRETE. <br />THE CONTRACTOR SHALL DESIGN AND CONSTRUCT COMPETENT FORMS AS <br />REQUIRED AND SHALL BE SOLELY RESPONSIBLE FOR THEIR ADEQUACY. <br />REINFORCEMENT SHALL BE PLACED AS CLOSE TO THE SURFACE OF CONCRETE AS <br />PERMITTED WHILE MAINTAINING MINIMUM COVER AS FOLLOWS (UNO): <br />AT SURFACES CAST AGAINST EARTH -- THREE INCHES (3"). <br />AT SURFACES EXPOSED TO EARTH OR WEATHER: <br />FOR #6 OR LARGER BARS -- TWO INCHES (2"). <br />FOR #5 AND SMALLER -- ONE AND ONE-HALF INCHES (1-1/2"). <br />PROJECTING CORNERS OF EXPOSED CONCRETE STRUCTURAL MEMBERS SHALL <br />BE FORMED WITH 3/4" CHAMFER (UNO). <br />REINFORCING STEEL, ANCHOR BOLTS, AND OTHER INSERTS SHALL BE SECURED IN <br />POSITION BEFORE CONCRETE PLACEMENT. SETTING DURING OR AFTER <br />PLACEMENT SHALL NOT BE PERMITTED (UNO). <br />EXCEPT FOR SIMPLE, SYMMETRICAL, UNIFORM CONFIGURATIONS, THE <br />CONTRACTOR SHALL PREPARE REINFORCEMENT PLACEMENT DRAWINGS. COPIES <br />OF THESE DRAWINGS SHALL BE AVAILABLE FOR REFERENCE ON SITE AT LEAST <br />ONE WORKING DAY BEFORE PLACEMENT OF CONCRETE AND BEFORE ANY <br />INSPECTION OF THE REINFORCEMENT OR FORMWORK. <br />THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES BEFORE PLACEMENT OF <br />CONCRETE TO ASSURE PROPER INCORPORATION OF REQUIRED SLEEVES, <br />INSERTS, CURBS, DEPRESSIONS AND SIMILAR ITEMS. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL COSTS OF <br />CORRECTIVE ACTION IN CASE OF ITEMS IMPROPERLY LOCATED OR OMITTED FROM <br />CONCRETE PLACEMENT. <br />THE CONTRACTOR SHALL SUBMIT SKETCHES SHOWING SIZE AND LOCATION OF <br />ANY REQUIRED SLEEVE, INSERT, DEPRESSION, OR OTHER MODIFICATION TO <br />STRUCTURAL CONCRETE NOT SHOWN IN THESE STRUCTURAL DESIGN DRAWINGS <br />TO SAA FOR REVIEW AND SHALL OBTAIN ITS APPROVAL BEFORE PLACEMENT. <br />CONCRETE SHALL BE PLACED, FINISHED, AND CURED IN ACCORDANCE WITH THE <br />RECOMMENDATIONS OF REFERENCED STANDARDS. <br />STRUCTURAL CONCRETE WITH SPECIFIED STRENGTH GREATER THAN 2500 PSI <br />SHALL BE PLACED UNDER THE CONTINUOUS SUPERVISION OF A DEPUTY <br />INSPECTOR LICENSED BY BUILDING DEPARTMENT. THIS INSPECTOR'S WORK <br />SHALL INCLUDE PRE-PLACEMENT INSPECTION OF FORMWORK, REINFORCEMENT <br />AND EMBEDDED ITEMS. <br />EXISTING CONCRETE AGAINST WHICH NEW CONCRETE IS TO BE PLACED SHALL BE <br />ROUGHENED TO AT LEAST 1/4" AMPLITUDE TO EXPOSE COARSE AGGREGATE, <br />SANDBLASTED OR OTHERWISE THOROUGHLY CLEANED BY AN APPROVED <br />METHOD, MOISTENED AND SCOURED WITH A CEMENT/WATER PASTE IMMEDIATELY <br />PRIOR TO PLACEMENT OF NEW MATERIAL. <br />COLD JOINTS IN STRUCTURAL CONCRETE SHALL BE MADE AT LOCATIONS <br />INDICATED IN DESIGN DRAWINGS OR APPROVED BY SAA. INCORPORATION OF <br />UNAPPROVED JOINTS SHALL BE SUFFICIENT CAUSE FOR REJECTION OF WORK. <br />CURING COMPOUNDS, IF USED, SHALL BE OF APPROVED TYPES. THE <br />CONTRACTOR SHALL OBTAIN WRITTEN APPROVAL OF CURING COMPOUNDS <br />PROPOSED FOR USE ON SURFACES TO RECEIVE FINISH FROM THE FINISH <br />MANUFACTURER PRIOR TO APPLICATION. <br />FORMS SHALL BE KEPT DAMP AND STRUCTURAL CONCRETE SURFACES EXPOSED <br />TO THE ENVIRONMENT SHALL BE MOIST CURED OR OTHERWISE PROTECTED <br />AGAINST PREMATURE DEHYDRATION FOR AT LEAST 72 HOURS AFTER PLACEMENT. <br />CONCRETE SHALL BE TESTED AND INSPECTED IN ACCORDANCE ACI-318 <br />REQUIREMENTS BY QUALIFIED TECHNICIANS UNDER THE SUPERVISION OF A LICENSED <br />CIVIL ENGINEER. <br />FOUR TEST CYLINDERS FROM EACH 150 YARDS, OR FRACTION THEREOF, POURED <br />IN ANY ONE DAY, SHALL BE SECURED AND TESTED BY AN INDEPENDENT TESTING <br />AGENCY; ONE TO BE TESTED AT 7 DAYS, TWO AT 28 DAYS, AND THE FOURTH HELD <br />IN RESERVE. <br />QUALIFIED FIELD TESTING TECHNICIANS SHALL PERFORM TESTS ON FRESH <br />CONCRETE AT THE JOB SITE, PREPARE SPECIMENS REQUIRED FOR CURING <br />UNDER FIELD CONDITIONS, PREPARE SPECIMENS REQUIRED FOR TESTING IN THE <br />LABORATORY, AND RECORD THE TEMPERATURE OF THE FRESH CONCRETE WHEN <br />PREPARING SPECIMENS FOR STRENGTH TESTS. QUALIFIED LABORATORY <br />TECHNICIANS SHALL PERFORM ALL REQUIRED LABORATORY TESTS. <br />THE CONTRACTOR SHALL REMOVE AND REPLACE ANY CONCRETE WHICH FAILS TO <br />ATTAIN SPECIFIED STRENGTH IN 28 DAYS IF SO DIRECTED BY THE ENGINEER OF <br />RECORD. ANY DEFECTS IN THE HARDENED CONCRETE SHALL BE SATISFACTORILY <br />REPAIRED OR THE HARDENED CONCRETE SHALL BE REPLACED. <br />A. <br />1. <br />2. <br />3. <br />B. <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />C. <br />D. <br />IN ADDITION TO CODE, THE FOLLOWING SPECIFICATIONS AND STANDARDS APPLY TO <br />THE MANUFACTURE, FABRICATION AND INSTALLATION OF REINFORCING STEEL IN <br />STRUCTURAL CONCRETE AND/OR MASONRY WORK FOR PROJECT: <br />CRSI HANDBOOK. <br />ASTM A615 GRADE 60 FOR ALL REINFORCING STEEL (UNO). <br />ASTM A185 FOR COLD DRAWN WELDED WIRE FABRIC (UNO). 4.AWS D1.4 FOR <br />WELDING OF REINFORCING STEEL. <br />QUALITY DETAILING AND CONSTRUCTION STANDARDS SHALL BE OBSERVED. <br />REINFORCEMENT SHALL BE TRACEABLE FROM SOURCE TO SITE AND SHALL BE <br />SAMPLED AND TESTED TO CONFIRM PHYSICAL PROPERTIES AS REQUIRED BY <br />BUILDING DEPARTMENT OR OTHERWISE NOTED IN THE PROJECT SPECIFICATION. <br />REINFORCEMENT DELIVERED TO THE SITE SHALL BE ACCOMPANIED BY <br />APPROPRIATE TESTING REPORTS AND CERTIFICATION, INCLUDING EVIDENCE OF <br />CONFORMANCE WITH SPECIAL DUCTILITY REQUIREMENTS SPECIFIED ABOVE. <br />LACK OF CERTIFICATION OR INADEQUATE CERTIFICATION SHALL BE SUFFICIENT <br />CAUSE FOR REJECTION OF MATERIAL. UNCERTIFIED OR INADEQUATELY CERTIFIED <br />MATERIAL SHALL NOT BE STORED AT THE SITE OR USED IN THE WORK AND IF <br />DELIVERED TO THE SITE SHALL BE IMMEDIATELY REMOVED. <br />SUBJECT TO SAA'S WRITTEN APPROVAL, REINFORCEMENT NOT MEETING THE <br />SPECIAL DUCTILITY REQUIREMENTS SPECIFIED ABOVE (NOTE 2) MAY BE PERMITTED <br />IN LOCATIONS NOT SUBJECT TO YIELDING UNDER SEISMIC LOAD. <br />BARS SHALL BE COLD BENT AS DETAILED OR OTHERWISE NECESSARY AROUND PINS <br />OF REQUIRED RADIUS. REBENDING OF BARS SHALL NOT BE PERMITTED (UNO). <br />BENDS SHALL BE MADE IN SHOP WHENEVER POSSIBLE. BENDING OF IN PLACE BARS <br />IN ANY MANNER WHICH MIGHT CAUSE STRESS TO EXISTING CONCRETE SHALL NOT <br />BE PERMITTED (UNO). <br />RUST, GREASE, MILL SCALE OR OTHER MATERIAL WHICH MIGHT EFFECT BOND TO <br />CONCRETE SHALL BE REMOVED IN AN APPROVED MANNER WITHOUT DAMAGE TO <br />THE REINFORCEMENT AND BEFORE PLACEMENT OF CONCRETE. <br />SEE CONCRETE NOTES FOR PLACEMENT DRAWING REQUIREMENTS. <br />WELDING OF REINFORCEMENT IS NOT PERMITTED, UNLESS SPECIFICALLY DETAILED IN <br />THE CONSTRUCTION DOCUMENTS. <br />ADDITIONAL TRIM AND CRACK CONTROL STEEL MAY BE REQUIRED DURING THE <br />PROGRESS OF THE WORK. AN ALLOWANCE OF AT LEAST ONE PERCENT BY WEIGHT OF <br />THE TOTAL REINFORCEMENT SHALL BE SET ASIDE FOR THIS PURPOSE. SUCH STEEL <br />SHALL BE FABRICATED AND PLACED AT SAA'S DIRECTION. <br />REINFORCING STEEL <br />S-002 <br />DIGITALLY STAMPED AND SIGNED 8.19.2024 <br />EXP: 9.30.2025