RESIDENTIAL LIGHTING DESIGN GUIDE <br />NEW WINDOW AND DOOR SCHEDULE <br />CITY OF SANTA ANA <br />�ld+ng Agency <br />ALL NEW CONSTRUCTION SHALL <br />BE DONE IN ACCORDANCE WITH THE 2022 <br />CALIFORNIA BUILDING,PLUMBING,MECHANICAL <br />AND ELECTRICAL CODES, AND ALL LOCAL <br />CODES AND ORDINANCES.ALL WORK SHALL <br />COMPLY WITH THE CALIFORNIA BUILDING <br />STANDARDS CODES FOUND IN THE STATE <br />OF CALIFORNIATITLE 24. <br />LIGHTAND VENTILATION PER CBC SECTION <br />1202.MINIMUM OF 15 CFM OF OUTSIDE AIR PER <br />OCCUPANT IS REQUIRED FOR VENTILATION. <br />ALL WOOD CONSTRUCTION SHALL COMPLY <br />WITH CODE SEC. 2308 AND MINIMUM NAILING <br />WITH CODE TABLE 2304.9.1 <br />WALLS WITH PLUMBING WILL BE 2X6 STUDS. <br />WALLS AROUND TUB AND SHOWERS TO BE <br />FINISHED WITH HARD NON -ABSORBENT MATERIAL. <br />TO 72" ABOVE DRAIN. <br />A MINIMUM WIDTH OF 30 AND 24 SPACE IN FRONT <br />IS REQUIRED IN ALL TOILETS. <br />ELECTRICAL NOTES <br />ALL ELECTRICAL TO COMPLY WITH N.E.C. <br />AND LOCAL CODE AND REGULATIONS. <br />1.-SMOKE DETECTORS ARE REQUIRED IN EACH <br />EXISTING SLEEPING ROOM AND IN THE <br />HALLWAY AREA SERVING EACH SLEEPING ROOM <br />BATTERY OPERATED DETECTORS ARE ACEPTABLE <br />FOR EXISTING CONSTRUCTION. <br />2.-ALL BEDROOMS, FAMILYROOMS, LIVINGROOMS, <br />DENS PARLORS, SUNROOMS, LIBRARIES, COMPUTER <br />AND RECREATION ROOMS, AND HALLWAYS CIRCUITS <br />(LIGHTING AND RECEPTACLES) MUST BE PROTECTED <br />BY ARC FAULT CIRCUIT INTERRUPTER (A.F.C.I.). <br />COMBINATION TYPE... KITCHEN, BATHROOMS AND <br />BASEMENTS ARE EXEMPT FROM THIS REQUIREMEN. <br />3.-PROVIDE FLOURESCENT LIGHTING IN BATHROOMS <br />AND KITCHENS. <br />4.-SMOKE DETECTORS TO BE POWERED BY 110V AND <br />HARDWIRED WITH A BATTERY BACKUP AND <br />SIMULTANEOUS ALARM.CONNECTED TO ALL SMOKE <br />DETECTORS. CARBON MONOXIDE DETECTORS SHALL <br />BE INTERCONECTED SUCH THAT THE ACTIVATION OF <br />ONE ALARM WILL ACTIVATE ALL ALARMS. <br />5.-ELECTRICAL FIXTURES INSTALLED ABOVE TUBS <br />AND SHOWERS TO BE WATERPROOF. <br />6.-ALL 125V SINGLE PHASE,15 AND 20 AMPHERE <br />RECEPTACLES INSTALLED IN THE FOLLOWING <br />LOCATIONS SHALL HAVE GROUND FAULT CIRCUIT <br />INTERRUPTER PROTECTION: <br />ALL RECEPTACLES LOCATED IN BATHROOMS, <br />GARAGES,OUTDOORS SERVING COUNTERTOP <br />IN KITCHENS AND IN WET BARS WITHIN 6' OF <br />A SINK. <br />7.-DUPLEX RECEPTACLES SHALL BE INSTALLED IN <br />ALL LIVING AND SLEEPING ROOMS SO THAT NO <br />POINT ALONG ANY LENGHT OF WALL 2'-0" OR <br />GREATER IS MORE THAN 6-0" FROM ANY OUTLET IN <br />THAT SPACE. <br />8.-DUPLEX RECEPTACLES SHALL BE INSTALLED IN <br />KITCHENS AT EACH COUNTER SPACE 12" OR WIDER, <br />AND SO THAT NO POINT ALONG ANY LENGHT OF <br />COUNTER IS MORE THAN 4'-0" FROM ANY OUTLET. <br />9.-ONE DUPLEX GFI RECEPTACLE SHALL BE <br />PROVIDED FOR EACH LAVATORY IN BATHROOMS. <br />BATHROOM RECEPTACLE OUTLETS SHALL BE <br />ALL BEDROOMS, FAMILYROOMS, LIVINGROOMS, <br />DENS PARLORS, SUNROOMS, LIBRARIES, <br />COMPUTER AND RECREATION ROOMS, AND <br />HALLWAYS CIRCUITS (LIGHTING AND <br />RECEPTACLES) MUST BE PROTECTED BY <br />ARC FAULT CIRCUIT INTERRUPTER (A.F.C.I.). <br />COMBINATION TYPE... KITCHEN, BATHROOMS <br />AND BASEMENTS ARE EXEMPT FROM THIS <br />REQUIREMEN. [CEC210.12(B)] <br />GLAZING NOTE: <br />GLAZING IN SWINGING, AND SLIDING DOORS <br />9 SQUARE FEET OR LESS SHALL BE A MINIMUM <br />CATEGORY CLASSIFICATION OF I (CPSC 16 CFR <br />1201) AND II WHEN MORE THAN 9 SQUARE FEET <br />OF SLIDING (CPSC 16 CFR 1201) .... [TABLE <br />R308.3.1(1), R308.3(1)] <br />ESCAPE WINDOW NOTE: <br />IN EVERY SLEEPING ROOM AND BASEMENT, <br />PROVIODE ONE OPENABLE ESCAPE WINDOW <br />MEETING ALL OF THE FOLLOWING: <br />A. AN OPENABLE AREA OF NOT LESS THAN <br />5.7 SQUARE FEET; <br />B. A MINIMUM 24 INCH CLEAR OPENABLE HEIGHT; <br />C. A MINUMUM CLEAR OPENABLE WIDTH OF 20 <br />INCHES; <br />D. A SILL HEIGHT NOT OVER 44 INCHES ABOVE <br />THE FLOOR. <br />NOTE: <br />20" X 24" DOES NOT EQUAL 5.7 <br />SQUARE FEET REFER TO THE <br />0f OPENABLE ILLUSTRATION FOR MINIMUM <br />w AREA DIMENTIONS REQUIRED FOR <br />0 OPENABLE AREA. <br />5.7 SQ. FT. <br />N MINIMUM OPENABLE <br />NET CLEAR AREA 24" <br />OPENING 5.7 SQ. FT. CLEAR <br />MINIMUM MIN. <br />I 20" NET d I 34" CLEAR .I <br />F CL R F MINIMUM <br />OPENABLE _ <br />C7 <br />WIDTH w xQ <br />_2 <br />J <br />J_ V <br />FLOOR LEVEL <br />WINDOW EGRESS DETAIL <br />SUPPLIED BY AT LEAST ONE 20AMP BRANCH <br />DOOR EGRESS NOTE <br />CIRCUIT, SUCH CIRCUITS SHALL HAVE NO OTHER <br />OUTLETS. <br />NOT LESS THAN ONE EGRESS DOOR SHALL BE PROVIDED <br />10.-ONE DUPLEX GFI RECEPTACLE EACH SHALL BE <br />PROVIDED AT. -FRONT OF DWELLING,REAR OF <br />FOR EACH DWELLING UNIT. THE EGRESS DOOR SHALL BE <br />DWELLING AND IN GARAGE. <br />SIDE -HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT <br />11.-HALLWAYS EXCEEDING 10'-0" IN LENGHT SHALL <br />BE PROVIDED WITH MIN. OF ONE DUPLEX <br />LESS THAN 32 INCHES WHERE MEASURED BEETWEEN THE <br />RECEPTACLE. <br />FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN <br />12.-PROVIDE POWER AND SWITCHED LIGHT FIXTURE <br />IN ATTIC ADJACENT TO ACCESS PANEL. <br />90 DEGRES. THE CLEAR HEIGHT OF THE DOOR OPENING <br />13.-ELECTRICAL CONTRACTOR TO SPECIFY <br />SHALL BE NOT LESS THAN 78 INCHES IN HEIGHT MEASURED <br />GROUNDING ELECTRODE SYSTEM BOND TO GAS AND <br />WATER PIPING. <br />FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF THE <br />14.-"ALL ELECTRICAL OUTLETS SHALL BE <br />STOP. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY <br />LISTED TAMPER RESISTANT RECEPTACLES" <br />(CEC 406.4 D.5) <br />WITH THESE MINIMUM DIMENSIONS. EGRESS DOORS SHALL <br />INSTALLED <br />BE READILY OPENABLE FROM INSIDE THE DWELLING WITOUT <br />IN ORKMANTSHALLBE <br />IN A NEAT AND WORKMANLIKE MANNER" <br />(CEC 2022 SECTION 110.12) <br />THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. <br />16.-"ALL LIGHTS SHALL BE DESIGNED AND LOCATED <br />SO THAT DIRECT RAYS ARE CONFINED TO THE <br />SMOKE DETECTORS <br />PROPERTY" <br />PROVIDE SMOKE DETECTORS IN THE AREAS LEADING TO <br />BEDROOMS.WHEN MORE THAN ONE SMOKE ALARM IS <br />PLUMBING NOTES <br />REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL <br />DWELLING UNIT THE ALARM DEVICES SHALL BE <br />ALL PLUMBING TO COMPLY WITH LOCAL CODE <br />AND REGULATIONS. <br />INTERCONNECTED IN SUCH A MANNER THAT THE <br />1.-ALL WATER CLOSETS IN THIS BUILDING TO BE <br />ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE <br />STATE OF CALIFORNIA DEPARTMENT OF HOUSING <br />AND MAXIMUM 1.28 GALLONS PER FLUSH. <br />ALARMS IN THE INDIVIDUAL UNIT. <br />2.-CONTROL VALVES FOR SHOWER AND TUB/SHOWER <br />SMOKE DETECTORS TO BE POWERED BY 110V AND <br />SHALL BE THE PRESSURE BALANCE OT THERMOSTATIC <br />MIXING VALVE TYPE. <br />HARDWIRED WITH A BATTERY BACKUP AND SIMULTANEOUS <br />3.-PROVIDE P&T RELEIF VALVE AT WATER HEATER. <br />ALARM. CONNECTED TO ALL SMOKE DETECTORS. <br />4.-PROVIDE BACKFLOW PREVENTER AT ALL HOSE <br />BIBBS. <br />WILL BE INSTALLED AND MAINTAINED ACCORDING TO <br />5.-MECHANICAL VENTILATION, WHERE OCCURS AT <br />MANUFACTER'S INSTRUCTIONS. <br />TOILET COMPARTMENTS, BATHROOMS AND LAUNDRY <br />ROOMS SHALL BE CAPABLE OF PROVIDING 5AIR <br />SMOKE ALARMS SHALL BE LISTED AND LABELED IN ACCORDANCE <br />CHANGES PER HOUR MIN. <br />WITH UL 217. <br />SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM <br />THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY <br />BATHROOM WALL COVERING NOTE <br />RA(;Kl IP <br />WALL COVERING TO BE CEMENT PLASTER, TILE <br />OR APPROVED EQUAL TO 72" ABOVE DRAIN AT <br />SHOWER OR TUB WITH SHOWERS. MATERIALS <br />OTHER THAN STRUCTURAL ELEMENTS SHALL BE <br />MOISTURE RESISTANT.GLASS ENCLOSURE <br />DOORS AND PANELS MUST BE LABELED <br />CATEGORY 11.SWING DOOR OUTWARD. NET AREA <br />OF SHOWER RECEPTOR SHALL BE NOT LESS THAN <br />1,024 SQ. IN. OF FLOOR AREA, AND ENCOMPASS 30" <br />DIAMETER CIRCLE. <br />LANDING NOTE: <br />A LANDING WITH A WIDTH NOT LESS THAN THE <br />WIDTH OF THE DOOR AND LENGTH IN THE <br />DIRECTION OF TRAVEL OF NOT LESS THAN 36 <br />INCHES,WILL BE PROVIDED ON EACH SIDE OF <br />DOORS.THE ELEVATION OF LANDING SHALL <br />NOT EXCEED 1 1/2 INCH DIFFERENCE THAN <br />THE THRESHOLD OF THE DOORWAY (7 3/4 INCH <br />IF DOOR DOES NOT SWING OVER THE LANDING <br />OR STEPS) IN EACH DIRECTION. [CRC R311.3.11 <br />LUMINARIES GENERAL NOTES: <br />1.-PERMANENTLY INSTALLED LUMINARIES IN: <br />2.-KITCHENS SHALL HIGH EFFICACY LUMINARIES <br />WITH SEPARATED CIRCUIT. <br />3.-BATH ROOMS, GARAGES, LAUNDRY ROOMS AND <br />UTILITY ROOMS SHALL BE HIGH EFFICACY <br />LUMINARIES, AND CONTROLLED BY AN OCCUPANT <br />SENSOR. <br />4.-OTHER THAN IN KITCHENS,BATHROOMS,GARAGES, <br />LAUNDRY ROOMS AND UTILITY ROOMS SHALL BE <br />HIGH EFFICACY LUMINARIES,OR CONTROLLED BY <br />DIMMER SWITCH, AND CONTROLLED BY AN OCCUPANT <br />SENSOR. <br />5.-OUTDOOR LIGHTING MOUNTED TO THE BUILDING <br />SHALL BE HIGH EFFICACY AND CONTROLLED BY <br />A PHOTO CONTROL/MOTION SENSOR. <br />CARBON MONOXIDE <br />PROVIDE CARBON MONOXIDE SENSORS IN THE AREAS <br />LEADING TO BEDROOMS. <br />WHEN MORE THAN ONE CARBON MONOXIDE ALARM IS <br />REQUIRED TO BE INSTALLED WITHIN THE DWELLING <br />UNIT OR SLEEPING UNIT THE ALARM SHALL BE <br />INTERCONNECTED IN SUCH A MANNER THAT THE <br />ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF <br />THE ALARMS IN THE INDIVIDUAL UNIT. <br />PROVIDE CARBON MONOXIDE ALARMS <br />IN DWELLING UNITS AND IN SLEEPING <br />UNITS WITHIN WHICH BURNING APPLIANCES <br />ARE INSTALLED AND IN DWELLING UNITS <br />THAT HAVE ATTACHED GARAGES. SHALL BE <br />INSTALLED OUTSIDE EACH SLEEPING AREA, <br />ON EVERY LEVEL OF A DWELLING UNIT. <br />CARBON MONOXIDE ALARMS SHALL COMPLY WITH <br />SPECIFIC LOCATION REQUIREMENTS PER NFPA 72 <br />SECTION 29.8.3.4 <br />CARBON MONOXIDE ALARMS PROVIDED SHALL BE <br />LISTED AND LABELED IN ACCORDANCE WITH UL 2034. <br />CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR <br />PRIMARY POWER FROM THE BUILDING WIRING AND SHALL <br />BE EQUIPPED WITH A BATTERY BACK UP. <br />CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED <br />SO THAT ACTIVATION OF ONE ALARM WILL ACTIVATE ALL <br />ALARMS WITHIN THE DWELLING UNIT. <br />ROOM NAME <br />MANDATORY LIGHTING MEASURES <br />KITCHEN <br />HIGH EFFICACY <br />AND <br />MANUAL -ON OCCUPANCY SENSOR <br />OR DIMMER <br />BATHROOM, GARAGE, <br />HIGH EFFICACY <br />LAUNDRY ROOM <br />AND <br />UTILITY ROOM <br />MANUAL -ON OCCUPANCY OR VACANT SENSOR <br />ALL OTHER INTERIOR <br />HIGH EFFICACY <br />ROOMS (E.G., LIVING <br />AND <br />ROOM, DINING ROOM, <br />MANUAL -ON OCCUPANCY SENSOR <br />BEDROOMS, HALLWAYS) <br />OR <br />EXCEPT CLOSET AND HALLWAYS LESS <br />DIVER <br />THAN 70 SQ. FT. <br />OUTDOOR LIGHTING <br />HIGH EFFICACY <br />ATTACHED TO BUILDINGS <br />AND <br />MANUAL -ON OCCUPANCY SENSOR > PHOTOCONTROL <br />ELECTRIC LEGEND <br />SINGLE POLE SWITCH <br />& <br />110V DUPLEX OUTLET <br />SMOKE DETECTOR <br />HARD WIRE W/BATTERY <br />BACKUP <br />LIGHT FIXTURE <br />HIGH EFFICACY <br />ll <br />/I I�GFI <br />11 OV DUPLEX OUTLET GFI <br />VACANCY SENSOR LIGHT <br />OR OCCUPANCY SENSOR <br />S <br />VACANCY SENSOR SWITCH <br />S <br />MOTION SENSOR CONTROL <br />O <br />CARBON MONOXIDE <br />co <br />ALARM <br />® <br />EXHAUST FAN <br />EXHAUST VENT TO BE: <br />NUTONE 50 to 80 CFM MODEL 744 RNL CEILING MOUNT <br />BATH FAN WITH 3 INCHES DUCT FLEXIBLE PIPE <br />DIRECTED TO OUTSIDE THROUGH ROOF (MAX <br />70 FEET WITHOUT ELBOWS PER ASHRA STANDARD 62.2 <br />TABLE 7.1) WITH A MAXIMUM SOUND RATING OR 2 SONE <br />FOR INTERMITTENT OPERATION. <br />�`L <br />�� <br />/I IVIGFI <br />BE INSTALLED SO THAT NO POINT ALONG <br />THE WALL LINE IS MORE THAN 24 INCHES. <br />[CEC 210.52(C)(1)] <br />VACANCY SENSOR LUMINAIRE NOTE <br />IN BATHROOMS, GARAGES, LAUNDRY ROOMS, <br />PANTRIES AND UTILITY/STORAGE ROOMS, AT <br />LEAST ONE LUMINAIRE SHALL BE CONTROLLED <br />BY AN OCCUPANT OR VACANCY SENSOR. <br />LUMINARIES FOR CLOSETS MORE THAN 70 SQ. FT. <br />SHALL BE CONTROLLED WITH DIMMERS OR <br />VACANCY SENSOR. <br />co <br />DRYER VENTS DUCT NOTE <br />DUCTS FOR DRYER VENTS SHALL BE A MINIMUM <br />OF 4" IN DIAMETER. THE EXHAUST DUCT SHALL <br />NOT EXCEED A TOTAL COMBINED HORIZONTAL <br />AND VERTICAL LENGHT OF 14 FEET, INCLUDING <br />TWO 90-DEGREE ELBOWS. TWO FEET SHALL BE <br />DEDUCTED FOR EACH 90-DEGREE ELBOW IN <br />EXCESS OF TWO. <br />ALL OUTLETS FOR DWELLINGS, OTHER THAN THOSE <br />COVERED IN 210.8 (A) (3), EXCEPTION TO (3), THAT <br />ARE SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS <br />RATED 150 VOLTS TO GROUND OR LESS, 50 AMPERES <br />OR LESS, SHALL HAVE GROUND -FAULT CIRCUIT <br />-INTERRUPTER PROTECTION FOR PERSONNEL. <br />Z JV <br />5} <br />=Zx <br />N <br />(E) HUNG <br />VINYL <br />2'-6" x 4'-6" <br />CLOSET <br />141 <br />4'-0" <br />J <br />} <br />Z <br />> cnc _ <br />wU)` o <br />ILLX A I <br />oW T_ <br />? Ilk <br />19 <br />nJN <br />_}x <br />- Z, <br />n >o <br />LU < <br />10'-8'/2" <br />SYMBOL <br />SIZE <br />DESCRIPTION <br />MATERIAL <br />U-FACTOR <br />SHGC <br />E4'0 <br />"X 4'0" <br />DBL PANE HUNG <br />VINYL <br />0.28 <br />0.22 <br />WINDOW <br />�1 <br />2'8"X 6'8" <br />HOLLOW INTERIOR <br />WOOD <br />DOOR <br />2 <br />2'6"X 6'8" <br />HOLLOW INTERIOR <br />WOOD <br />DOOR <br />E3'0"X <br />6'8" <br />CLOSET <br />WOOD <br />DOOR <br />F <br />J <br />4'0"X 6'8" <br />CLOSET <br />WOOD <br />DOOR <br />(E) HUNG (E) HUNG <br />VINYL VINYL <br />2'-0" x 3'-0" 2'-0" x 3'-0" <br />0 0 <br />(E) KITCHEN <br />NEW BEDROOM <br />35'-3" <br />33'-911 1'-611 <br />DRYER <br />DUCT <br />O 4- <br />M (N) <br />O� <br />ZW <br />1= Uj <br />SL)O <br />wU <br />(E) WALL <br />(E) DINING AREA <br />o <br />\ CV <br />00 <br />o \ <br />10'-5 9/16" <br />C <br />CV ' <br />6'-0" <br />OPENING <br />L <br />(E) LIVING ROOM. <br />V-0" x 4'-6" 4'-6" x 4'-6" 1'4" 4'-6" V-0" x 4'-6" <br />(E) HUNG (E) FIXED (E) UNG (E) HUNG <br />VINYL VINYL VI YL VINYL <br />(E) PORCH <br />33'-9" <br />0 <br />LO <br />4TER HEA <br />3'-0" x 4'-6" <br />(E) BEDROOM #2 <br />24"x30" CLEAR SPACE <br />IN FRONT OF THE TOILET. <br />THE SINK CANNOT ENCROACH <br />INTO THE CLEAR SPACE, <br />2'-8" 2'-6" <br />shower <br />pO4'-6" <br />V <br />00 <br />(N) BAT (p <br />HALLWAY 24"� II <br />N <br />ATT 6 <br />�CESS <br />(E) BEDROOM #1 <br />V-0" x 4'-6" 1'-0" A 4'-6" 4'-6" x 4'-6" V-0" x 4'-6" <br />(E) HUNG (E) H NG (E) FIXED (E) HUNG <br />VINYL VI YL VINYL VINYL <br />co of <br />"toJ <br />X_ -IZ <br />o�> <br />Mw <br />a <br />zo (7 <br />Z <br />xZ Z <br />oW > <br />�0_ <br />1'-6 <br />r <br />LO <br />rel <br />FOR PERMIT ISSUANCE <br />Mas er ID: <br />Dat <br />E <br />0 <br />O <br />0 <br />0 <br />ru <br />Ln <br />Ln <br />0 <br />E <br />Ev *, <br />AN <br />qm <br />ID <br />c? <br />0 <br />v <br />N <br />u � <br />> v <br />N <br />N O <br />Am 0) 2- <br />O <br />V J <br />O <br />UJ��^N <br />VJ <br />wz(n <br />u <br />z00< <br />Z <br />O <br />O <br />�!�/^� <br />V) <br />< <br />uj <br />mCOZ <br />v , <br />Z <br />L.I. <br />O <br />O <br />J <br />LL• <br />W <br />Z <br />D RAW N <br />O.M. <br />CHECKED <br />DATE <br />02-27-2025 <br />SCALE <br />AS NOTED <br />JOB NO. <br />2507 <br />SHEET NO. <br />A-3 <br />