RESIDENTIAL LIGHTING DESIGN GUIDE
<br />NEW WINDOW AND DOOR SCHEDULE
<br />CITY OF SANTA ANA
<br />�ld+ng Agency
<br />ALL NEW CONSTRUCTION SHALL
<br />BE DONE IN ACCORDANCE WITH THE 2022
<br />CALIFORNIA BUILDING,PLUMBING,MECHANICAL
<br />AND ELECTRICAL CODES, AND ALL LOCAL
<br />CODES AND ORDINANCES.ALL WORK SHALL
<br />COMPLY WITH THE CALIFORNIA BUILDING
<br />STANDARDS CODES FOUND IN THE STATE
<br />OF CALIFORNIATITLE 24.
<br />LIGHTAND VENTILATION PER CBC SECTION
<br />1202.MINIMUM OF 15 CFM OF OUTSIDE AIR PER
<br />OCCUPANT IS REQUIRED FOR VENTILATION.
<br />ALL WOOD CONSTRUCTION SHALL COMPLY
<br />WITH CODE SEC. 2308 AND MINIMUM NAILING
<br />WITH CODE TABLE 2304.9.1
<br />WALLS WITH PLUMBING WILL BE 2X6 STUDS.
<br />WALLS AROUND TUB AND SHOWERS TO BE
<br />FINISHED WITH HARD NON -ABSORBENT MATERIAL.
<br />TO 72" ABOVE DRAIN.
<br />A MINIMUM WIDTH OF 30 AND 24 SPACE IN FRONT
<br />IS REQUIRED IN ALL TOILETS.
<br />ELECTRICAL NOTES
<br />ALL ELECTRICAL TO COMPLY WITH N.E.C.
<br />AND LOCAL CODE AND REGULATIONS.
<br />1.-SMOKE DETECTORS ARE REQUIRED IN EACH
<br />EXISTING SLEEPING ROOM AND IN THE
<br />HALLWAY AREA SERVING EACH SLEEPING ROOM
<br />BATTERY OPERATED DETECTORS ARE ACEPTABLE
<br />FOR EXISTING CONSTRUCTION.
<br />2.-ALL BEDROOMS, FAMILYROOMS, LIVINGROOMS,
<br />DENS PARLORS, SUNROOMS, LIBRARIES, COMPUTER
<br />AND RECREATION ROOMS, AND HALLWAYS CIRCUITS
<br />(LIGHTING AND RECEPTACLES) MUST BE PROTECTED
<br />BY ARC FAULT CIRCUIT INTERRUPTER (A.F.C.I.).
<br />COMBINATION TYPE... KITCHEN, BATHROOMS AND
<br />BASEMENTS ARE EXEMPT FROM THIS REQUIREMEN.
<br />3.-PROVIDE FLOURESCENT LIGHTING IN BATHROOMS
<br />AND KITCHENS.
<br />4.-SMOKE DETECTORS TO BE POWERED BY 110V AND
<br />HARDWIRED WITH A BATTERY BACKUP AND
<br />SIMULTANEOUS ALARM.CONNECTED TO ALL SMOKE
<br />DETECTORS. CARBON MONOXIDE DETECTORS SHALL
<br />BE INTERCONECTED SUCH THAT THE ACTIVATION OF
<br />ONE ALARM WILL ACTIVATE ALL ALARMS.
<br />5.-ELECTRICAL FIXTURES INSTALLED ABOVE TUBS
<br />AND SHOWERS TO BE WATERPROOF.
<br />6.-ALL 125V SINGLE PHASE,15 AND 20 AMPHERE
<br />RECEPTACLES INSTALLED IN THE FOLLOWING
<br />LOCATIONS SHALL HAVE GROUND FAULT CIRCUIT
<br />INTERRUPTER PROTECTION:
<br />ALL RECEPTACLES LOCATED IN BATHROOMS,
<br />GARAGES,OUTDOORS SERVING COUNTERTOP
<br />IN KITCHENS AND IN WET BARS WITHIN 6' OF
<br />A SINK.
<br />7.-DUPLEX RECEPTACLES SHALL BE INSTALLED IN
<br />ALL LIVING AND SLEEPING ROOMS SO THAT NO
<br />POINT ALONG ANY LENGHT OF WALL 2'-0" OR
<br />GREATER IS MORE THAN 6-0" FROM ANY OUTLET IN
<br />THAT SPACE.
<br />8.-DUPLEX RECEPTACLES SHALL BE INSTALLED IN
<br />KITCHENS AT EACH COUNTER SPACE 12" OR WIDER,
<br />AND SO THAT NO POINT ALONG ANY LENGHT OF
<br />COUNTER IS MORE THAN 4'-0" FROM ANY OUTLET.
<br />9.-ONE DUPLEX GFI RECEPTACLE SHALL BE
<br />PROVIDED FOR EACH LAVATORY IN BATHROOMS.
<br />BATHROOM RECEPTACLE OUTLETS SHALL BE
<br />ALL BEDROOMS, FAMILYROOMS, LIVINGROOMS,
<br />DENS PARLORS, SUNROOMS, LIBRARIES,
<br />COMPUTER AND RECREATION ROOMS, AND
<br />HALLWAYS CIRCUITS (LIGHTING AND
<br />RECEPTACLES) MUST BE PROTECTED BY
<br />ARC FAULT CIRCUIT INTERRUPTER (A.F.C.I.).
<br />COMBINATION TYPE... KITCHEN, BATHROOMS
<br />AND BASEMENTS ARE EXEMPT FROM THIS
<br />REQUIREMEN. [CEC210.12(B)]
<br />GLAZING NOTE:
<br />GLAZING IN SWINGING, AND SLIDING DOORS
<br />9 SQUARE FEET OR LESS SHALL BE A MINIMUM
<br />CATEGORY CLASSIFICATION OF I (CPSC 16 CFR
<br />1201) AND II WHEN MORE THAN 9 SQUARE FEET
<br />OF SLIDING (CPSC 16 CFR 1201) .... [TABLE
<br />R308.3.1(1), R308.3(1)]
<br />ESCAPE WINDOW NOTE:
<br />IN EVERY SLEEPING ROOM AND BASEMENT,
<br />PROVIODE ONE OPENABLE ESCAPE WINDOW
<br />MEETING ALL OF THE FOLLOWING:
<br />A. AN OPENABLE AREA OF NOT LESS THAN
<br />5.7 SQUARE FEET;
<br />B. A MINIMUM 24 INCH CLEAR OPENABLE HEIGHT;
<br />C. A MINUMUM CLEAR OPENABLE WIDTH OF 20
<br />INCHES;
<br />D. A SILL HEIGHT NOT OVER 44 INCHES ABOVE
<br />THE FLOOR.
<br />NOTE:
<br />20" X 24" DOES NOT EQUAL 5.7
<br />SQUARE FEET REFER TO THE
<br />0f OPENABLE ILLUSTRATION FOR MINIMUM
<br />w AREA DIMENTIONS REQUIRED FOR
<br />0 OPENABLE AREA.
<br />5.7 SQ. FT.
<br />N MINIMUM OPENABLE
<br />NET CLEAR AREA 24"
<br />OPENING 5.7 SQ. FT. CLEAR
<br />MINIMUM MIN.
<br />I 20" NET d I 34" CLEAR .I
<br />F CL R F MINIMUM
<br />OPENABLE _
<br />C7
<br />WIDTH w xQ
<br />_2
<br />J
<br />J_ V
<br />FLOOR LEVEL
<br />WINDOW EGRESS DETAIL
<br />SUPPLIED BY AT LEAST ONE 20AMP BRANCH
<br />DOOR EGRESS NOTE
<br />CIRCUIT, SUCH CIRCUITS SHALL HAVE NO OTHER
<br />OUTLETS.
<br />NOT LESS THAN ONE EGRESS DOOR SHALL BE PROVIDED
<br />10.-ONE DUPLEX GFI RECEPTACLE EACH SHALL BE
<br />PROVIDED AT. -FRONT OF DWELLING,REAR OF
<br />FOR EACH DWELLING UNIT. THE EGRESS DOOR SHALL BE
<br />DWELLING AND IN GARAGE.
<br />SIDE -HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT
<br />11.-HALLWAYS EXCEEDING 10'-0" IN LENGHT SHALL
<br />BE PROVIDED WITH MIN. OF ONE DUPLEX
<br />LESS THAN 32 INCHES WHERE MEASURED BEETWEEN THE
<br />RECEPTACLE.
<br />FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN
<br />12.-PROVIDE POWER AND SWITCHED LIGHT FIXTURE
<br />IN ATTIC ADJACENT TO ACCESS PANEL.
<br />90 DEGRES. THE CLEAR HEIGHT OF THE DOOR OPENING
<br />13.-ELECTRICAL CONTRACTOR TO SPECIFY
<br />SHALL BE NOT LESS THAN 78 INCHES IN HEIGHT MEASURED
<br />GROUNDING ELECTRODE SYSTEM BOND TO GAS AND
<br />WATER PIPING.
<br />FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF THE
<br />14.-"ALL ELECTRICAL OUTLETS SHALL BE
<br />STOP. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY
<br />LISTED TAMPER RESISTANT RECEPTACLES"
<br />(CEC 406.4 D.5)
<br />WITH THESE MINIMUM DIMENSIONS. EGRESS DOORS SHALL
<br />INSTALLED
<br />BE READILY OPENABLE FROM INSIDE THE DWELLING WITOUT
<br />IN ORKMANTSHALLBE
<br />IN A NEAT AND WORKMANLIKE MANNER"
<br />(CEC 2022 SECTION 110.12)
<br />THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.
<br />16.-"ALL LIGHTS SHALL BE DESIGNED AND LOCATED
<br />SO THAT DIRECT RAYS ARE CONFINED TO THE
<br />SMOKE DETECTORS
<br />PROPERTY"
<br />PROVIDE SMOKE DETECTORS IN THE AREAS LEADING TO
<br />BEDROOMS.WHEN MORE THAN ONE SMOKE ALARM IS
<br />PLUMBING NOTES
<br />REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL
<br />DWELLING UNIT THE ALARM DEVICES SHALL BE
<br />ALL PLUMBING TO COMPLY WITH LOCAL CODE
<br />AND REGULATIONS.
<br />INTERCONNECTED IN SUCH A MANNER THAT THE
<br />1.-ALL WATER CLOSETS IN THIS BUILDING TO BE
<br />ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE
<br />STATE OF CALIFORNIA DEPARTMENT OF HOUSING
<br />AND MAXIMUM 1.28 GALLONS PER FLUSH.
<br />ALARMS IN THE INDIVIDUAL UNIT.
<br />2.-CONTROL VALVES FOR SHOWER AND TUB/SHOWER
<br />SMOKE DETECTORS TO BE POWERED BY 110V AND
<br />SHALL BE THE PRESSURE BALANCE OT THERMOSTATIC
<br />MIXING VALVE TYPE.
<br />HARDWIRED WITH A BATTERY BACKUP AND SIMULTANEOUS
<br />3.-PROVIDE P&T RELEIF VALVE AT WATER HEATER.
<br />ALARM. CONNECTED TO ALL SMOKE DETECTORS.
<br />4.-PROVIDE BACKFLOW PREVENTER AT ALL HOSE
<br />BIBBS.
<br />WILL BE INSTALLED AND MAINTAINED ACCORDING TO
<br />5.-MECHANICAL VENTILATION, WHERE OCCURS AT
<br />MANUFACTER'S INSTRUCTIONS.
<br />TOILET COMPARTMENTS, BATHROOMS AND LAUNDRY
<br />ROOMS SHALL BE CAPABLE OF PROVIDING 5AIR
<br />SMOKE ALARMS SHALL BE LISTED AND LABELED IN ACCORDANCE
<br />CHANGES PER HOUR MIN.
<br />WITH UL 217.
<br />SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM
<br />THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY
<br />BATHROOM WALL COVERING NOTE
<br />RA(;Kl IP
<br />WALL COVERING TO BE CEMENT PLASTER, TILE
<br />OR APPROVED EQUAL TO 72" ABOVE DRAIN AT
<br />SHOWER OR TUB WITH SHOWERS. MATERIALS
<br />OTHER THAN STRUCTURAL ELEMENTS SHALL BE
<br />MOISTURE RESISTANT.GLASS ENCLOSURE
<br />DOORS AND PANELS MUST BE LABELED
<br />CATEGORY 11.SWING DOOR OUTWARD. NET AREA
<br />OF SHOWER RECEPTOR SHALL BE NOT LESS THAN
<br />1,024 SQ. IN. OF FLOOR AREA, AND ENCOMPASS 30"
<br />DIAMETER CIRCLE.
<br />LANDING NOTE:
<br />A LANDING WITH A WIDTH NOT LESS THAN THE
<br />WIDTH OF THE DOOR AND LENGTH IN THE
<br />DIRECTION OF TRAVEL OF NOT LESS THAN 36
<br />INCHES,WILL BE PROVIDED ON EACH SIDE OF
<br />DOORS.THE ELEVATION OF LANDING SHALL
<br />NOT EXCEED 1 1/2 INCH DIFFERENCE THAN
<br />THE THRESHOLD OF THE DOORWAY (7 3/4 INCH
<br />IF DOOR DOES NOT SWING OVER THE LANDING
<br />OR STEPS) IN EACH DIRECTION. [CRC R311.3.11
<br />LUMINARIES GENERAL NOTES:
<br />1.-PERMANENTLY INSTALLED LUMINARIES IN:
<br />2.-KITCHENS SHALL HIGH EFFICACY LUMINARIES
<br />WITH SEPARATED CIRCUIT.
<br />3.-BATH ROOMS, GARAGES, LAUNDRY ROOMS AND
<br />UTILITY ROOMS SHALL BE HIGH EFFICACY
<br />LUMINARIES, AND CONTROLLED BY AN OCCUPANT
<br />SENSOR.
<br />4.-OTHER THAN IN KITCHENS,BATHROOMS,GARAGES,
<br />LAUNDRY ROOMS AND UTILITY ROOMS SHALL BE
<br />HIGH EFFICACY LUMINARIES,OR CONTROLLED BY
<br />DIMMER SWITCH, AND CONTROLLED BY AN OCCUPANT
<br />SENSOR.
<br />5.-OUTDOOR LIGHTING MOUNTED TO THE BUILDING
<br />SHALL BE HIGH EFFICACY AND CONTROLLED BY
<br />A PHOTO CONTROL/MOTION SENSOR.
<br />CARBON MONOXIDE
<br />PROVIDE CARBON MONOXIDE SENSORS IN THE AREAS
<br />LEADING TO BEDROOMS.
<br />WHEN MORE THAN ONE CARBON MONOXIDE ALARM IS
<br />REQUIRED TO BE INSTALLED WITHIN THE DWELLING
<br />UNIT OR SLEEPING UNIT THE ALARM SHALL BE
<br />INTERCONNECTED IN SUCH A MANNER THAT THE
<br />ACTIVATION OF ONE ALARM SHALL ACTIVATE ALL OF
<br />THE ALARMS IN THE INDIVIDUAL UNIT.
<br />PROVIDE CARBON MONOXIDE ALARMS
<br />IN DWELLING UNITS AND IN SLEEPING
<br />UNITS WITHIN WHICH BURNING APPLIANCES
<br />ARE INSTALLED AND IN DWELLING UNITS
<br />THAT HAVE ATTACHED GARAGES. SHALL BE
<br />INSTALLED OUTSIDE EACH SLEEPING AREA,
<br />ON EVERY LEVEL OF A DWELLING UNIT.
<br />CARBON MONOXIDE ALARMS SHALL COMPLY WITH
<br />SPECIFIC LOCATION REQUIREMENTS PER NFPA 72
<br />SECTION 29.8.3.4
<br />CARBON MONOXIDE ALARMS PROVIDED SHALL BE
<br />LISTED AND LABELED IN ACCORDANCE WITH UL 2034.
<br />CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR
<br />PRIMARY POWER FROM THE BUILDING WIRING AND SHALL
<br />BE EQUIPPED WITH A BATTERY BACK UP.
<br />CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED
<br />SO THAT ACTIVATION OF ONE ALARM WILL ACTIVATE ALL
<br />ALARMS WITHIN THE DWELLING UNIT.
<br />ROOM NAME
<br />MANDATORY LIGHTING MEASURES
<br />KITCHEN
<br />HIGH EFFICACY
<br />AND
<br />MANUAL -ON OCCUPANCY SENSOR
<br />OR DIMMER
<br />BATHROOM, GARAGE,
<br />HIGH EFFICACY
<br />LAUNDRY ROOM
<br />AND
<br />UTILITY ROOM
<br />MANUAL -ON OCCUPANCY OR VACANT SENSOR
<br />ALL OTHER INTERIOR
<br />HIGH EFFICACY
<br />ROOMS (E.G., LIVING
<br />AND
<br />ROOM, DINING ROOM,
<br />MANUAL -ON OCCUPANCY SENSOR
<br />BEDROOMS, HALLWAYS)
<br />OR
<br />EXCEPT CLOSET AND HALLWAYS LESS
<br />DIVER
<br />THAN 70 SQ. FT.
<br />OUTDOOR LIGHTING
<br />HIGH EFFICACY
<br />ATTACHED TO BUILDINGS
<br />AND
<br />MANUAL -ON OCCUPANCY SENSOR > PHOTOCONTROL
<br />ELECTRIC LEGEND
<br />SINGLE POLE SWITCH
<br />&
<br />110V DUPLEX OUTLET
<br />SMOKE DETECTOR
<br />HARD WIRE W/BATTERY
<br />BACKUP
<br />LIGHT FIXTURE
<br />HIGH EFFICACY
<br />ll
<br />/I I�GFI
<br />11 OV DUPLEX OUTLET GFI
<br />VACANCY SENSOR LIGHT
<br />OR OCCUPANCY SENSOR
<br />S
<br />VACANCY SENSOR SWITCH
<br />S
<br />MOTION SENSOR CONTROL
<br />O
<br />CARBON MONOXIDE
<br />co
<br />ALARM
<br />®
<br />EXHAUST FAN
<br />EXHAUST VENT TO BE:
<br />NUTONE 50 to 80 CFM MODEL 744 RNL CEILING MOUNT
<br />BATH FAN WITH 3 INCHES DUCT FLEXIBLE PIPE
<br />DIRECTED TO OUTSIDE THROUGH ROOF (MAX
<br />70 FEET WITHOUT ELBOWS PER ASHRA STANDARD 62.2
<br />TABLE 7.1) WITH A MAXIMUM SOUND RATING OR 2 SONE
<br />FOR INTERMITTENT OPERATION.
<br />�`L
<br />��
<br />/I IVIGFI
<br />BE INSTALLED SO THAT NO POINT ALONG
<br />THE WALL LINE IS MORE THAN 24 INCHES.
<br />[CEC 210.52(C)(1)]
<br />VACANCY SENSOR LUMINAIRE NOTE
<br />IN BATHROOMS, GARAGES, LAUNDRY ROOMS,
<br />PANTRIES AND UTILITY/STORAGE ROOMS, AT
<br />LEAST ONE LUMINAIRE SHALL BE CONTROLLED
<br />BY AN OCCUPANT OR VACANCY SENSOR.
<br />LUMINARIES FOR CLOSETS MORE THAN 70 SQ. FT.
<br />SHALL BE CONTROLLED WITH DIMMERS OR
<br />VACANCY SENSOR.
<br />co
<br />DRYER VENTS DUCT NOTE
<br />DUCTS FOR DRYER VENTS SHALL BE A MINIMUM
<br />OF 4" IN DIAMETER. THE EXHAUST DUCT SHALL
<br />NOT EXCEED A TOTAL COMBINED HORIZONTAL
<br />AND VERTICAL LENGHT OF 14 FEET, INCLUDING
<br />TWO 90-DEGREE ELBOWS. TWO FEET SHALL BE
<br />DEDUCTED FOR EACH 90-DEGREE ELBOW IN
<br />EXCESS OF TWO.
<br />ALL OUTLETS FOR DWELLINGS, OTHER THAN THOSE
<br />COVERED IN 210.8 (A) (3), EXCEPTION TO (3), THAT
<br />ARE SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS
<br />RATED 150 VOLTS TO GROUND OR LESS, 50 AMPERES
<br />OR LESS, SHALL HAVE GROUND -FAULT CIRCUIT
<br />-INTERRUPTER PROTECTION FOR PERSONNEL.
<br />Z JV
<br />5}
<br />=Zx
<br />N
<br />(E) HUNG
<br />VINYL
<br />2'-6" x 4'-6"
<br />CLOSET
<br />141
<br />4'-0"
<br />J
<br />}
<br />Z
<br />> cnc _
<br />wU)` o
<br />ILLX A I
<br />oW T_
<br />? Ilk
<br />19
<br />nJN
<br />_}x
<br />- Z,
<br />n >o
<br />LU <
<br />10'-8'/2"
<br />SYMBOL
<br />SIZE
<br />DESCRIPTION
<br />MATERIAL
<br />U-FACTOR
<br />SHGC
<br />E4'0
<br />"X 4'0"
<br />DBL PANE HUNG
<br />VINYL
<br />0.28
<br />0.22
<br />WINDOW
<br />�1
<br />2'8"X 6'8"
<br />HOLLOW INTERIOR
<br />WOOD
<br />DOOR
<br />2
<br />2'6"X 6'8"
<br />HOLLOW INTERIOR
<br />WOOD
<br />DOOR
<br />E3'0"X
<br />6'8"
<br />CLOSET
<br />WOOD
<br />DOOR
<br />F
<br />J
<br />4'0"X 6'8"
<br />CLOSET
<br />WOOD
<br />DOOR
<br />(E) HUNG (E) HUNG
<br />VINYL VINYL
<br />2'-0" x 3'-0" 2'-0" x 3'-0"
<br />0 0
<br />(E) KITCHEN
<br />NEW BEDROOM
<br />35'-3"
<br />33'-911 1'-611
<br />DRYER
<br />DUCT
<br />O 4-
<br />M (N)
<br />O�
<br />ZW
<br />1= Uj
<br />SL)O
<br />wU
<br />(E) WALL
<br />(E) DINING AREA
<br />o
<br />\ CV
<br />00
<br />o \
<br />10'-5 9/16"
<br />C
<br />CV '
<br />6'-0"
<br />OPENING
<br />L
<br />(E) LIVING ROOM.
<br />V-0" x 4'-6" 4'-6" x 4'-6" 1'4" 4'-6" V-0" x 4'-6"
<br />(E) HUNG (E) FIXED (E) UNG (E) HUNG
<br />VINYL VINYL VI YL VINYL
<br />(E) PORCH
<br />33'-9"
<br />0
<br />LO
<br />4TER HEA
<br />3'-0" x 4'-6"
<br />(E) BEDROOM #2
<br />24"x30" CLEAR SPACE
<br />IN FRONT OF THE TOILET.
<br />THE SINK CANNOT ENCROACH
<br />INTO THE CLEAR SPACE,
<br />2'-8" 2'-6"
<br />shower
<br />pO4'-6"
<br />V
<br />00
<br />(N) BAT (p
<br />HALLWAY 24"� II
<br />N
<br />ATT 6
<br />�CESS
<br />(E) BEDROOM #1
<br />V-0" x 4'-6" 1'-0" A 4'-6" 4'-6" x 4'-6" V-0" x 4'-6"
<br />(E) HUNG (E) H NG (E) FIXED (E) HUNG
<br />VINYL VI YL VINYL VINYL
<br />co of
<br />"toJ
<br />X_ -IZ
<br />o�>
<br />Mw
<br />a
<br />zo (7
<br />Z
<br />xZ Z
<br />oW >
<br />�0_
<br />1'-6
<br />r
<br />LO
<br />rel
<br />FOR PERMIT ISSUANCE
<br />Mas er ID:
<br />Dat
<br />E
<br />0
<br />O
<br />0
<br />0
<br />ru
<br />Ln
<br />Ln
<br />0
<br />E
<br />Ev *,
<br />AN
<br />qm
<br />ID
<br />c?
<br />0
<br />v
<br />N
<br />u �
<br />> v
<br />N
<br />N O
<br />Am 0) 2-
<br />O
<br />V J
<br />O
<br />UJ��^N
<br />VJ
<br />wz(n
<br />u
<br />z00<
<br />Z
<br />O
<br />O
<br />�!�/^�
<br />V)
<br /><
<br />uj
<br />mCOZ
<br />v ,
<br />Z
<br />L.I.
<br />O
<br />O
<br />J
<br />LL•
<br />W
<br />Z
<br />D RAW N
<br />O.M.
<br />CHECKED
<br />DATE
<br />02-27-2025
<br />SCALE
<br />AS NOTED
<br />JOB NO.
<br />2507
<br />SHEET NO.
<br />A-3
<br />
|