Laserfiche WebLink
ROOF <br />SLOPE <br />±2:12 <br />ROOF <br />SLOPE <br />±2:12 <br />ROOF <br />SLOPE <br />±2:12 <br />ROOF <br />SLOPE <br />±2:12 <br />ROOF <br />SLOPE <br />±2:12 <br />ROOF <br />SLOPE <br />±2:12 <br />RO <br />O <br />F <br />SL <br />O <br />P <br />E <br />2% <br /> <br />M <br />I <br />N <br />W/D <br />SHOWER <br />T.V. <br />DINNING <br />2161 sq.in <br />372.7 sq.ft <br />12.4 sq.ft <br />23'-0" <br />21 <br />' <br />- <br />9 <br />" <br />18 <br />' <br />- <br />4 <br />" <br />3 <br />STACKED <br />OVEN <br />5 <br />1 <br />6 <br />6 <br />2 <br />3 <br />4 <br />4 <br />7 <br />1 2 3 4 5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />5' <br />- <br />3 <br />" <br />6' <br />- <br />1 <br />1 <br />" <br />1' <br />- <br />3 <br />" <br />2' <br />- <br />6 <br />" <br />3' <br />- <br />2 <br />" <br />3'-0" <br />6'-0" <br />3' <br />- <br />0 <br />" <br />LANDING <br />8 <br />11 <br />TEMP. GLAZING <br />2' <br />- <br />0 <br />" <br />2'-0" <br />60" TUB SHOWER <br />BEDROOM 2 <br />120.9 SQ.FT <br />21 <br />' <br />- <br />9 <br />" <br />2 <br />BEDROOM 1 <br />172.3 SQ.FT <br />54.1 SQ.FT <br />54.1 SQ.FT <br />BATH <br />23'-0" <br />2 <br />4 <br />2 <br />2'-8" <br />W.I.C <br />3 <br />BALCONY11 3' <br />- <br />4 <br />" <br />3'-0" <br />3' <br />- <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />15 <br />16 <br />17 <br />14 <br />5' <br />- <br />3 <br />" <br />LANDING <br />LANDING <br />W.I.C <br />9TEMP. GLAZING <br />TEMP. GLAZING <br />(E) 2-CAR GARAGE <br />DOOR <br />COMPRSSIBLE <br />ELEMENT <br />THRESHOLD <br />INTERIOR <br />FLOOR LEVEL <br />EXTERIOR FLOOR <br />OR LANDING LEVEL <br />7 <br />3 <br />4" <br />I <br />N <br />. <br /> M <br />A <br />X <br />. <br />12" <br />I <br />N <br />. <br />MI <br />N <br />DOOR SWINGS <br />DETAIL 1: THRESHOLD DETAIL <br />SCALE: NTS <br />2X FRAMING <br />SEE STRUCTURAL PLAN <br />5/8 " TYPE "X" GYPSUM <br />BOARD AT INTERIOR <br />PER PLAN <br />GRADE 'D' 60 MINUTE <br />BUILDING PAPER, (USE <br />TWO LAYERS WHEN <br />APPLIED OVER SOLID <br />PANELS) <br />RESILIENT CHANNELS <br />PERPENDICULAR TO <br />JOISTS AT 16 O.C. <br />EXTERIOR STUD WALL DETAIL <br />SCALE: NTS <br />3" Min. BATT <br />INSULATION (PER <br />PLAN) <br />EXTERIOR CEMENT <br />PLASTER ON CORROSION <br />RESISTANT METAL LATH <br />5/8 " TYPE "X" GYPSUM <br />BOARD AT INTERIOR <br />PER PLAN <br />ATTIC CALCULATIONS <br />PROVIDE ATTIC VENTS AT A RATE OF 1 S.Q. PER 150 FT OF AREA BEING VENTILATED, IF THE VENTILATION <br />IS ONLY BEING PROVIDED ON THE EAVES ONLY. IF AT LEAST 40 PERCENT BUT NOT MORE THAN 50 OF THE <br />VENTILAION IS BEING PROVIDED WITH IN 3 FEET MEASURED VERTICALLY FROM THE RIDGE OR HIGHEST <br />POINT OF THE AREA BEING VENTILATED . THE VENTILATION RAE CAN BE REDUCED TO 1S.F. FOR 300 S.F. <br />BEING SERVED. PROVIDE RAFTER SPACE VENTILATON. (CRC R806) <br />ATTIC AREA=0.00 S.F. <br />VENT AREA REQUIRED 69.00 S.F/150 S.F =.5 S.F.= 72 SQ-IN <br />VENT PROVIDED= (400.0 SQ-IN) OF DORMER <br />USE= (2) DORMERS (453.6 SQ-IN) <br /> NOTE:DORMER N.F.V.=100 SQ-IN <br />(N) 2'X4' SLIDING WINDOW U-0.3 SHG-0.23 <br />DUAL GLAZE - TEMP <br />3 <br />FLOOR PLAN <br />AND DEMO PLAN <br />A-2 <br />WALL LEGEND <br />DEMO WALL <br />PROPOSED WALL <br />NOTE: <br />a.All emergency escape and rescue openings <br />shall have a minimum clear opening of 5.7 square <br />feet with a <br />minimum net clear opening height of 24 <br />inches and width of 20 inches (R310.2.1). <br />b. Where a window is provided as the <br />emergency escape and rescue opening, it shall <br />have the bottom of the clear <br />opening not greater than 44 inches measured <br />from the floor (R310.2.2). <br />c. Emergency escape and rescue openings <br />shall be clear of any obstruction and operational <br />from the inside of the <br />room without the use of keys, tools or special <br />knowledge (R310.1.1 <br />d.NFRC window labels to be removed only by <br />owners after final building inspection <br />e. 13 oz. face wt. carpet (31 oz. tot) and 40 oz. <br />jutted pad, or 48 oz. foam rubber, or 3/8" rebonded <br /> urethane foam (4 pcf), or ½" urethane foam <br />(2.4 pcf). <br />f. 2. Type and spacing of resilient channels <br />and the attachment of channels and gypsum board <br />or lath <br /> shall be as required for fire ratings. <br />g. 3. Sheet vinyl and linoleum floor coverings <br />with 1/8" minimum thickness resilient backing may <br /> be substituted for carpet and padding in <br />kitchen and bathroom areas, if ceilings are on <br />resilient channels. <br />h. 4. The mineral fiber insulation shall have a <br />thermal resistance R value of 11 or greater as <br />determined <br /> by Federal Specification HH-I-521E. <br />GLAZING NOTES: <br /> The following shall be considered specific <br />hazardous locations requiring safety glazing per <br />Section R308: <br /> a. Glazing in fixed and operable panels of <br />swinging, sliding, and bifold doors. <br /> b. Glazing in fixed or operable panels <br />adjacent to a door where the bottom exposed <br />edge of the glazing is less than 60 inches above <br />the <br /> walking surface and it meets either of <br />the following conditions: <br /> 1. Where the glazing is within 24 inches of <br />either side of the door in the plane of the door in <br />a <br /> closed position. <br /> 2. Where the glazing is on a wall <br />perpendicular to the plane of the door in a closed <br />position and within 24 inches of the hinge side <br />on an <br /> in-swinging door. <br /> c. Window glazing in an individual fixed or <br />operable panel, that meets all of the following <br />conditions: <br /> 1. The exposed area of an individual pane <br />is larger than 9 square feet. <br /> 2. The bottom edge is less than 18 inches <br />above the floor. <br /> 3. The top edge is more than 36 inches <br />above the floor. <br /> 4. One or more walking surfaces are <br />within 36 inches, measured horizontally and in a <br />straight line, of the glazing. <br /> d. Glazing in guards, railings, structural <br />baluster panels, and nonstructural in-fill panels, <br />regardless of area or height above a walking <br /> surface. <br /> e. Glazing in walls, enclosures or fences <br />containing or facing hot tubs, spas, whirlpools, <br />saunas, steam rooms, bathtubs, showers, and <br /> indoor or outdoor swimming pools, <br />where all of the following conditions are present: <br /> 1. The bottom edge of the glazing is less <br />than 60 inches above any standing or walking <br />surface. <br /> 2. The glazing is within 60 inches, <br />measured horizontally and in a straight line, from <br />the water’s edge of a hot tub, spa, whirlpool, <br /> bathtub, or swimming pool, or from the <br />edge of a shower, sauna or steam room. <br /> f. Glazing adjacent to stairs and ramps <br />where the bottom exposed edge is less than 36 <br />inches above the plane of the adjacent walking <br /> surface of stairways, landings between <br />flights of stairs, and ramps, unless the glazing is <br />36 inches or moremeasured horizontally from <br /> the walking surface, or a rail is <br />designed per Section R308.4.6. <br /> g. Glazing adjacent to the landing at the <br />bottom of a stairway where the glazing is less <br />than 36 inches above the landing and within a <br /> 60-inch horizontal arc less than 180 <br />degrees from the bottom treadnosing, unless the <br />glazing is more than 18 inches from a <br />protective guard per Section R312. <br />WINDOW SCHEDULE <br />DOOR SCHEDULE <br />(N) 3' X 6'-8" exterior glass double door, U-0.3 <br />SHG-0.23 Dual Glaze - TEMP <br />A PROJECT FOR: <br />PROJECT ADDRESS: <br />SHEET TITLE <br />DATE: <br />SHEET: <br />PROJECT INFO <br />PROJECT # <br />DRAWN BY: <br />CHECKED BY: <br />SCALE: <br />AS SHOWN <br />AT <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br />DW <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />74 <br />0 <br /> <br />W <br /> <br />S <br />t <br />. <br /> <br />A <br />N <br />D <br />R <br />E <br />W <br />S <br /> <br />P <br />L <br />A <br />C <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />- <br />2 <br />6 <br />2 <br />1 <br />REVISED BY: <br />REVISIONS: <br />DATE:BY: <br />PROJECT: <br />REVISED BY: <br />DESIGNER: YMMAR BROWN <br />ENGINEER: VISAL TE <br />(N) 5' X 6' SLIDING WINDOW U-0.3 SHG-0.23 <br /> DUAL GLAZE - TEMP <br />(N) 3'X4' SLIDING WINDOW U-0.3 SHG-0.23 <br />DUAL GLAZE - TEMP <br />2 <br />1 <br />2 <br />1 <br />1 OWNER TO PROVIDE SHOWER HEAD AND FIXTURES. <br />PROVIDE A 24" X 30" CLEAR SPACE IN FRONT OF WATER CLOSE. <br />DOUBLE SINK WITH GARBAGE DISPOSAL. <br />LANDING 3'x3' (4" CONCRETE SLAB) WITH#4 REBAR WITH 18" O.C. <br />EACH WAY. <br />PIECE FIBERGLASS SHOWER/TUB COMBO W/ TEMPERED GLASS. <br />SHOWER COMPARTMENT REGARDLESS OF SHAPE, SHALL HAVE A <br />MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES AND <br />SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH CIRCLE, <br />THE DIMENSIONS SHALL BE MAINTAINED TO A POINT OF 70 INCHES <br />ABOVE THE SHOWER DRAIN OUTLET WITH NO <br />PROTRUSIONS OTHER THAN THE VALVE(S), SHOWERHEAD, SOAP <br />DISH, SHELVES, AND SAFETY GRAB BARS, OR RAILS. (CPC 408.6) <br />STACKED WASHER DRYER, PROVIDE METAL PAN WITH DRAIN TO <br />DRAIN OR DAY LIGHT <br />CONDENSER, PROVIDE A A 3' X 3'X4" CONCRETE PAD W. #4 REBAR <br />3 MIN. EACH WAY <br />ASPHALT SHINGLE TIMBERLINE ESR1475 TO MATCH (E) HOME <br />TMP STANDING METAL SEAM ROOFING PANEL ESR5046 <br />HANDRAILS SHALL BE A MIN FOR 34" AND A MAX OR 38" ABOVE <br />EACH FLIGHT OF STAIR MEASURE VERTICALLY FROM LINE <br />CONNECTING EACH LEADING EDGE. SHALL BE CONTINUOUS FROM <br />THE FIRST RISER TO THE LAST RISER. <br />FUTURE HEAT PUMP WATER HEATER (2.5'X2.5'X7') <br />WALL LINE TO BE DEMOLISHED. <br />WALL LINE TO BE RETAINED. <br />GARAGE DOOR TO BE DEMOLISHED. <br />SEE DETAIL 1 ON SHEET A-2 <br />DURABLE, NON-ABSORBENT FINISH <br />MATERIAL W/ DEX-O-TREX (ESR-1757) <br />UNDERSIDE OF EAVE OVERHANG <br />SHALL BE 1-HR FIRE RATED PER <br />DETAIL 1 ON SHEET A-3. <br />SEE DETAIL-3 ON SHEET A-3. <br />(MINIMUM 1 HANDRAIL ON ONE SIDE <br />REQUIRED). <br />3 <br />5 <br />2 <br />6 <br />7 <br />8 <br />NOTE LEGEND <br />10 <br />4 <br />9 <br />ALL PLUMBING FIXTURES SHALL COMPLY TO SENATE BILL 407 <br />WATER LINE OF TYPE "L" COPPER <br />WATER CONSERVING PLUMBING FIXTURES & FITTINGS AS DEFINED BY <br />2019 CALIFORNIA BUILDING CODE (SECTION 4.303) ARE: <br />1.28 GALL/FLUSH TOILET <br />2.0 GALLON/MINUTE SINGLE SHOWER HEAD AT 80 PSI* <br />1.2 GALLON /MINUTE LAVATORY FAUCETS AT 60 PSI <br />1.8 GALLON/MINUTE KITCHEN FAUCETS AT 60 PSI <br />PLUMBING REQUIREMENTS <br />WHERE STATIC PRESSURE IN THE WATER SUPPLY PIPING IS EXCEEDING <br />80 PSI AN APPROVED PRESSURE REGULATOR PROCEEDED BY AN <br />ADEQUATE STRAINER SHALL BE INSTALLED. (CPC SEC 608.2) <br />GENERAL <br />PROVIDE WATER SYSTEM WITH A PRESSURE REGULATOR, CHECK <br />VALVE, BACKFLOW PREVENTER OR OTHER NORMALLY CLOSED DEVICE <br />THAT PREVENTS DISSIPATION OF BUILDING PRESSURE BACK INTO THE <br />WATER MAIN, WITH AN EXPANSION TANK. CPC SEC. 608.2 & 608.3 <br />THE DISCHARGE PIPING SERVING A TEMPERATURE RELIEF VALVE, PRESSURE RELIEF <br />OR COMBINATION OF BOTH SHALL BE PROVIDED WITH A DRAIN, NOT SMALLER <br />THAN THE RELIEF VALVE OUTLET, SHALL DISCHARGE INDEPENDENTLY BY GRAVITY <br />THROUGH AN AIR GAP INTO THE DRAINAGE SYSTEM OR EXTEND OUTSIDE THE <br />BUILDING WITH THE END OF THE PIPE NOT MORE THAN 2’ FEET NOR LESS THAN 6” <br />INCHES ABOVEGROUND AND POINTING DOWNWARD AND DISCHARGE IN A MANNER <br />THAT DOES NOT CAUSE PERSONAL INJURY (CPC SEC. 608.5) <br />30" CLR <br />24" CLR <br />15" <br />15" <br />24" <br />SCALE: 1/4" = 1'-0" <br />ROOF PLAN <br />(N) 4'X6'8" SLIDING WINDOW U-0.3 SHG-0.23 <br />DUAL GLAZE - TEMP <br />4 <br />(N) 32" X 6'-8" hollow core interior pocket door3 <br />SCALE: 1/4" = 1'-0" <br />(N) 2ND FLOOR PLAN <br />SCALE: 1/4" = 1'-0" <br />(N) 1ST FLOOR PLAN <br />(N) 3'X5' SLIDING WINDOW U-0.3 SHG-0.23 <br />DUAL GLAZE - TEMP <br />5 <br />5 2 <br />2 <br />3 <br />4 <br />4 <br />5 5 <br />6 <br />7 <br />12 <br />8 <br />SCALE: 1/4" = 1'-0" <br />(E) FLOOR/DEMO PLAN <br />6 (N) 3'0"X8' FIXED WINDOW U-0.3 SHG-0.23 <br />DUAL GLAZE - TEMP <br />4 (N) 8'X8' FIXED DOOR U-0.3 SHG-0.23 <br />DUAL GLAZE - TEMP <br />A-A <br />A-4 <br />A-A <br />A-4 <br />9 <br />B- <br />B <br />A- <br />4 <br />B- <br />B <br />A- <br />4 <br />10/16/2024 <br />YB <br />7 (N) 1'6"X5' FIXED WINDOW U-0.3 SHG-0.23 <br />DUAL GLAZE - TEMP <br />(N) 3' X 6'-8" exterior glass single door, U-0.3 <br />SHG-0.23 Dual Glaze - TEMP (N) 2'0"X5' FIXED WINDOW U-0.3 SHG-0.23 <br />DUAL GLAZE - TEMP <br />(N) 2'6"X2' FIXED WINDOW U-0.3 SHG-0.23 <br />DUAL GLAZE - TEMP <br />8 <br />9 <br />EXISTING WALL <br />FIRST FLOOR ADDITION AREA <br />1 <br />11 <br />11 <br />11 <br />12 <br />13 <br />12 <br />12 <br />13 <br />14 <br />13 <br />14 <br />15 <br />15 <br />15 <br />SEE SHEET A-4 FOR ALL ELECTRICAL <br />REQUIREMENTS/NOTES-CALLOUTS. <br />16 <br />16 <br />17 <br />17 17 <br />18 <br />18 <br />18