Laserfiche WebLink
8' <br />- <br />0 <br />" <br />12 <br />' <br />- <br />3 <br />1 4" <br />12 <br />4 <br />12 <br />4 <br />XXX1:XXXXXXXXXXAAABBB <br />Project Name <br />Rev.Desciption Date <br />Drawing Title <br />Project ID <br />D A T E <br />Drawing No. <br />09-23 <br />MI <br />K <br />H <br />A <br />I <br />L <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />CITY REVISION 4/01/24 <br />OW <br />N <br />E <br />R <br />: <br /> <br />H <br />A <br />N <br />Y <br /> <br />L <br />. <br /> <br />M <br />I <br />K <br />H <br />A <br />I <br />L <br />PH <br />O <br />N <br />E <br /> <br />: <br /> <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />6 <br />9 <br />6 <br />- <br />2 <br />7 <br />9 <br />7 <br />CITY REVISION 4/17/24 <br />CITY REVISION 10/24/24 <br />CITY REVISION 02/26/25 <br />A-2.2 <br />EL <br />E <br />V <br />A <br />T <br />I <br />O <br />N <br />S <br />SIDE - SOUTH ELEVATION <br />SCALE: 1/4" = 1'-0" <br />BACK - WEST ELEVATION <br />SCALE: 1/4" = 1'-0" <br />14 <br />' <br />- <br />8 <br />1 2" <br />11 <br />' <br />- <br />1 <br />0 <br />1 4"14 <br />' <br />- <br />8 <br />1 2" <br />30 YR. COMP. SHINGLES OVER 15 LB. FELT <br />UNDERLAYMENT CLASS 'A' RATED. ASPHALT <br />ROOFING SHINGLES ICC-ES AC438 TO MATCH <br />EXISTING BUILDING TYP. <br />EXISTING ROOF <br />LINE OF FINISH <br />FLOOR <br />LINE OF FINISH <br />GRADE <br />SIDE - NORTH ELEVATION <br />SCALE: 1/4" = 1'-0" <br />FRONT - EAST ELEVATION <br />SCALE: 1/4" = 1'-0" <br />ROOF JOINING LINEEXISTING ROOF <br />30 YR. COMP. SHINGLES OVER <br />15 LB. FELT UNDERLAYMENT <br />CLASS 'A' RATED. <br />ASPHALT ROOFING SHINGLES <br />ICC-ES AC438 TO MATCH <br />EXISTING BUILDING TYP. <br />12 <br />4 <br />8' <br />- <br />0 <br />" <br />12 <br />' <br />- <br />3 <br />1 4" <br />13 <br />' <br />- <br />6 <br />" <br />EXISTING 1x4 SURROUND <br />WRAP & STUCCO (TYP.)NEW 1x4 SURROUND <br />WRAP & STUCCO (TYP.) <br />TO MATCH EXISTING ON <br />COLOR AND SHAPE <br />EXISTING BUILDING <br />LINE <br />7/8" THK STUCCO (TYP.) <br />TO MATCH EXISTING <br />LINE OF FINISH <br />FLOOR <br />LINE OF FINISH <br />GRADE <br />30 YR. COMP. SHINGLES OVER <br />15 LB. FELT UNDERLAYMENT <br />CLASS 'A' RATED. <br />ASPHALT ROOFING SHINGLES <br />ICC-ES AC438 TO MATCH <br />EXISTING BUILDING TYP. <br />2x6 FASCIA BOARD w/ 26 <br />GA. G.I. DRIP EDGE. (TYP.) <br />TO MATCH EXISTING <br />F. <br />F <br />. <br /> <br />T <br />O <br /> <br />B <br />O <br />T <br />. <br /> <br />O <br />F <br /> <br />H <br />D <br />R <br />. <br />6' <br />- <br />1 <br />0 <br />" <br />8' <br />- <br />0 <br />" <br />14 <br />' <br />- <br />8 <br />1 2" <br />12 <br />4 <br />12 <br />4 <br />8' <br />- <br />0 <br />" <br />11 <br />' <br />- <br />1 <br />0 <br />1 4"14 <br />' <br />- <br />8 <br />1 2" <br />7/8" THK STUCCO (TYP.) <br />TO MATCH EXISTING <br />EXISTING LINE OF <br />FINISH FLOOR <br />LINE OF FINISH <br />GRADE <br />30 YR. COMP. SHINGLES OVER <br />15 LB. FELT UNDERLAYMENT <br />CLASS 'A' RATED. <br />ASPHALT ROOFING SHINGLES <br />ICC-ES AC438 TO MATCH EXISTING <br />BUILDING TYP. <br />2x6 FASCIA BOARD <br />w/ 26 GA. G.I. DRIP <br />EDGE. (TYP.) <br />TO MATCH EXISTING <br />EXISTING ROOFEXISTING ROOF <br />NEW 1x4 SURROUND <br />WRAP & STUCCO (TYP.) <br />TO MATCH EXISTING ON <br />COLOR AND SHAPE <br />12 <br />4 <br />EXISTING LINE OF <br />FINISH FLOOR <br />8' <br />- <br />0 <br />" <br />1' <br />- <br />2 <br />" <br />1' <br />- <br />2 <br />" <br />6' <br />- <br />1 <br />0 <br />" <br />F. <br />F <br />. <br /> <br />T <br />O <br /> <br />B <br />O <br />T <br />. <br /> <br />O <br />F <br /> <br />H <br />D <br />R <br />. <br />6' <br />- <br />1 <br />0 <br />" <br />F. <br />F <br />. <br /> <br />T <br />O <br /> <br />B <br />O <br />T <br />. <br /> <br />O <br />F <br /> <br />H <br />D <br />R <br />. <br />12 <br />4 <br />ROOF JOINING LINE EXISTING ROOF <br />30 YR. COMP. SHINGLES OVER <br />15 LB. FELT UNDERLAYMENT <br />CLASS 'A' RATED. <br />ASPHALT ROOFING SHINGLES <br />ICC-ES AC438 TO MATCH EXISTING <br />BUILDING TYP. <br />7/8" THK STUCCO (TYP.) <br />TO MATCH EXISTING <br />LINE OF FINISH <br />FLOOR <br />LINE OF FINISH <br />GRADE <br />30 YR. COMP. SHINGLES OVER <br />15 LB. FELT UNDERLAYMENT <br />CLASS 'A' RATED. <br />ASPHALT ROOFING SHINGLES <br />ICC-ES AC438 TO MATCH EXISTING <br />BUILDING TYP. <br />8' <br />- <br />0 <br />" <br />14 <br />' <br />- <br />8 <br />1 2" <br />2x6 FASCIA BOARD w/ 26 <br />GA. G.I. DRIP EDGE. (TYP.) <br />TO MATCH EXISTING <br />12 <br />4 <br />8' <br />- <br />0 <br />" <br />12 <br />' <br />- <br />3 <br />1 4" <br />13 <br />' <br />- <br />5 <br />1 2" <br />NEW 1x4 SURROUND <br />WRAP & STUCCO (TYP.) <br />TO MATCH EXISTING ON <br />COLOR AND SHAPE <br />FULLY TEMPERED <br />1' <br />- <br />2 <br />" <br />FLOOR VENTILATION CALCULATIONS <br />906 / 150 * 144 = 869.76 SQ. IN REQUIRED <br />REQUIRED <br />14 16X8 VENTS @ 64 SQ. IN EA. <br />PROVIDED <br />896 SQ. IN. PROVIDED <br />4 <br />16X8 UNDER <br />FLOOR VENT (TYP. <br />OF 14) <br />4 <br />1' <br />- <br />2 <br />" <br />4 <br />4 <br />4 <br />4 <br />4 <br />NOTE: <br />UNDER-FLOOR SPACES SHALL BE VENTILATED BY OPENINGS INTO <br />THEUNDER-FLOOR SPACE EXTERIOR WALLS. SUCH OPENINGS SHALL <br />HAVE A NET AREA OF NOT LESS THAN 1 SQUARE FOOT FOR EACH 150 <br />SQUARE FEET OFUNDER-FLOOR AREA. ONE VENTILATION OPENINGS <br />SHALL BE LOCATED WITHIN 3-FT. OF EACH CORNER OF THE BUILDING AND <br />PROVIDE CROSS VENTILATION.VENTILATION OPENINGS SHALL BE <br />COVERED WITH CORROSION RESISTANT MESH W/ LEAST DIMENSION NOT <br />EXCEEDING 1/4".