Laserfiche WebLink
(N) BEDROOM <br />ATTIC <br />ACCESS <br />22" x 30" <br />(N) 100 AMP. <br />SUB-PANEL <br />WH <br />(E <br />) <br /> <br />3 <br />6 <br />" <br />3 <br />6 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />(E) PORCH <br />(E) KITCHEN <br />(E) BEDROOM 2 <br />(E) BEDROOM 3 <br />(E) BEDROOM 4 <br /> (E) BATH 1 <br />(E) BEDROOM 1 <br />(E) BATH 2 <br />ATTIC <br />ACCESS <br />F.A.U. <br />29'-0" <br />7'-8" <br />12'-11" <br />12'-0" <br />10'-1"23'-6"14'-0" <br />58'-1" <br />16'-5" <br />5'-7"26'-9"11'-2" <br />10'-8" <br />12'-0" <br />(E <br />) <br /> <br />4 <br />8 <br />" <br />4 <br />8 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />(E) 48"48" VINYL WINDOW <br />(E <br />) <br /> <br />4 <br />8 <br />" <br />4 <br />8 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />(E) 48"48" VINYL WINDOW <br />(E) 24"36" VINYL WINDOW(E) 60"36" VINYL WINDOW <br />(E <br />) <br /> <br />7 <br />2 <br />" <br />4 <br />8 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />(E) 96"80" VINYL SLIDING DOOR <br />(E) 36"12" VINYL WINDOW <br />(E <br />) <br /> <br />6 <br />0 <br />" <br />4 <br />8 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />(E <br />) <br /> <br />7 <br />2 <br />" <br />8 <br />0 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />D <br />O <br />O <br />R <br />(E) 48"48" VINYL WINDOW <br />UL 2034/2075 RATED <br />@ (E) HOUSE <br />COSD <br />SD <br />SDSD <br />SD <br />SD UL 217 RATED @ <br />(E) HOUSE (TYP.) <br />STACKED <br />W/D <br />10'-6" <br />2'-6" <br />6'-4" <br />21'-9" <br />5'-0" <br />3'-0" <br />3" <br />(N) BATH <br />(N) LIVING AREA <br />(N) KITCHEN <br />30" <br />1,024 SI <br />1' <br />- <br />4 <br />" <br />1' <br />- <br />6 <br />" <br />(N) JADU 100A <br />SUB-PANEL <br />(N <br />) <br /> <br />3 <br />- <br />G <br />A <br />N <br />G <br />PA <br />N <br />E <br />L <br />, <br />10 <br />0 <br />A <br /> <br />E <br />A <br />C <br />H <br />(E) DINING <br />AREA <br />(E <br />) <br /> <br />B <br />A <br />T <br />H <br /> <br />3 <br />FI <br />R <br />E <br />P <br />L <br />A <br />C <br />E <br />(E) LIVING AREA <br />STACKED <br />W/D <br />5'-0"3" <br />3'-0" <br />14 <br />SD-1 <br />TANKLESS GAS WH ON 1" <br />DEDICATED GAS LINE (TYP. 2) <br />ATTIC <br />ACCESS <br />22" x 30" <br />LUMINAIRES LOCATED <br />ABOVE BATHTUB OR <br />SHOWER SHALL BE <br />LISTED FOR WET <br />LOCATIONS <br />SMOKE DETECTOR IN <br />LIVING ROOM (WITHIN 20' <br />FROM THE COOK TOP) <br />SHALL BE IONIZED OR <br />PHOTOELECTRIC TYPE <br />WALLS AT SHOWERS <br />SHALL BE <br />TILE/CEMENT <br />PLASTER, MINIMUM 72" <br />ABOVE FLOOR. <br />HOOD VENT THROUGH ROOF, <br />400 CFM MIN., INSTALLED PER <br />MANU. SPECS. HOOD SHALL <br />COMPLY W/ ASHRAE 62.2(C) <br />(TYP. 2) <br />$ <br />WH <br />(N) BEDROOM <br />(N) LIVING AREA <br />(N) KITCHEN <br />(N <br />) <br /> <br />A <br />C <br />CO <br />N <br />D <br />E <br />N <br />S <br />E <br />R <br /> <br />O <br />N <br />3" <br /> <br />C <br />O <br />N <br />C <br />R <br />E <br />T <br />E <br /> <br />P <br />A <br />D <br />(N <br />) <br /> <br />A <br />C <br />CO <br />N <br />D <br />E <br />N <br />S <br />E <br />R <br /> <br />O <br />N <br />3" <br /> <br />C <br />O <br />N <br />C <br />R <br />E <br />T <br />E <br /> <br />P <br />A <br />D <br />14'-7" <br />9'-7" <br />2'-6" <br />STACKED <br />W/D <br />(N) ADU 100A <br />SUB-PANEL <br />S-AS-A <br />40 AMP. <br />40 AMP. <br />DUCTLESS MINI <br />SPLIT AC <br />DUCTLESS MINI <br />SPLIT AC <br />DUCTLESS MINI <br />SPLIT AC <br />DU <br />C <br />T <br />L <br />E <br />S <br />S <br /> <br />M <br />I <br />N <br />I <br />SP <br />L <br />I <br />T <br /> <br />A <br />C <br />SD <br />CO <br />SD <br />COSD <br />SD <br />$$ <br />$$ <br />AFCI (TYP.) <br />GFCI (TYP.) <br />AFCI (TYP.) <br />GFCI (TYP.) <br />$ <br />WR-GFCI <br />$3 <br />$3 <br />$3D $3 <br />$D <br />WR-GFCI <br />$ <br />$3 <br />$3 <br />$D <br />$VS <br />$ <br />AFCI (TYP.)AFCI (TYP.) <br />MAX. 48" MEASURED <br />FROM TOP, MIN. 15" <br />MEASURED FROM <br />BOTTOM OF BOX <br />ABOVE F.F. (TYP.) <br />$3D <br />$3 <br />AFCI (TYP.) <br />AFCI (TYP.) <br />18 <br />SD-1 <br />SPACE OF MIN 2.5’x2.5’x7’ TALL <br />FOR FUTURE INSTALLATION OF <br />A HEAT PUMP WATER HEATER <br />CONDENSATE DRAIN <br />THAT IS NO MORE THAN <br />2" HIGHER THAN THE <br />BASE OF THE INSTALLED <br />WATER HEATER <br />HEAT-PUMP READY WATER HEATER NOTES <br />1. A DEDICATED 125 VOLT, 20 AMP ELECTRICAL RECEPTACLE <br />CONNECTED TO A 120/240V 3 CONDUCTOR, 10 AWG COPPER <br />BRANCH CIRCUIT, WITHIN 3' OF THE WATER HEATER AND <br />ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTION; AND <br />2. BOTH ENDS OF THE UNUSED CONDUCTOR SHALL BE LABELED <br />"SPARE" AND BE ELECTRICALLY ISOLATED; AND <br />3. A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE <br />ELECTRICAL PANEL ADJACENT TO THE CIRCUIT FOR 125 VOLT, 20 <br />AMP ABOVE AND LABELED "FUTURE 240V USE"; AND <br />4. A CONDENSATE DRAIN THAT IS NO MORE THAN 2" HIGHER THAN <br />THE BASE OF THE INSTALLED WATER HEATER. <br />WH <br />CONDENSATE DRAIN <br />THAT IS NO MORE THAN <br />2" HIGHER THAN THE <br />BASE OF THE INSTALLED <br />WATER HEATER <br />SPACE OF MIN 2.5’x2.5’x7’ TALL <br />FOR FUTURE INSTALLATION OF <br />A HEAT PUMP WATER HEATER <br />S-B <br />S-B <br />(N) FLOOR PLAN <br />SCALE: 1/4" = 1'-0" <br />CARBON MONOXIDE AND SMOKE DETECTOR NOTES <br />SMOKE DETECTOR SHALL BE PROVIDED IN EACH SLEEPING ROOM <br />AND AREA GIVING ACCESS TO THE SLEEPING ROOMS <br />1. NEW CONSTRUCTION: CO AND SMOKE DETECTORS SHALL RECEIVE <br />THEIR PRIMARY POWER FROM BUILDING WIRING WITH BATTERY <br />BACKUP. <br />2. EXISTING MAIN HOUSE: BATTERY POWERED UL 2034/2075 RATED <br />CARBON MONOXIDE ALARM AND UL 217 RATED SMOKE ALARMS SHALL <br />BE INSTALLED IN MARKED LOCATIONS. <br />ELECTRICAL NOTES <br />1.PROVIDE ONE 20 AMP. CIRCUIT FOR BATHROOM OUTLETS. SUCH CIRCUIT SHALL HAVE NO OTHER <br />OUTLETS. <br />2.PROVIDE 2 DEDICATED GENERAL APPLIANCE CIRCUITS TO THE KITCHEN AREA. <br />3.ALL INSTALLED LUMINAIRES MUST BE HIGH EFFICACY IN ACCORDANCE WITH TABLE 150.0-A. <br />4.ALL RECEPTACLES IN BATHROOMS SHALL BE G.F.C.I. <br />5.SERVICE PANEL/METER UPGRADE OR NEW: OBTAIN LOCATION APPROVAL FROM THE ELECTRICAL <br />PROVIDER. <br />6.ALL BRANCH CIRCUITS SUPPLYING RECEPTACLE OUTLETS IN KITCHENS, BEDROOMS, FAMILY <br />ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, DENS, SUNROOMS, HALLWAYS, CLOSETS AND <br />SIMILAR ROOMS/AREAS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER (AFCI). <br />7.NON-HIGH EFFICACY LUMINAIRES SHALL BE SWITCHED ON A SEPARATE CIRCUIT FROM HIGH <br />EFFICACY LUMINAIRES. <br />8.ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED <br />HORIZONTALLY BY 24" . BACK AND SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT <br />AND BACKED WITH 2" MIN. MINERAL FIBER INSULATION. <br />9.ALL RECEPTACLE OUTLETS SHALL BE LISTED AS TAMPER-RESISTANT OUTLETS. <br />10.ALL OUTDOOR LIGHTING MOUNTED TO A RESIDENTIAL BUILDING SHALL BE HIGH EFFICACY LIGHTING <br />OR CONTROLLED BY A PHOTOCELL AND MOTION SENSOR COMBINATION. <br />PLUMBING NOTES <br />1.BATH FAN SHALL BE CONTROLLED BY HUMIDISTAT WITH ADJUSTMENT BETWEEN A RELATIVE <br />HUMIDITY RANGE 50-80%. <br />2.SHOWER WALLS ABOVE BATHTUB WITH SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, <br />NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 6' ABOVE FLOOR. <br />3.SHOWER COMPARTMENT SHALL BE MINIMUM 1,024 SQ. IN. AND SHALL BE CAPABLE OF <br />ENCOMPASSING A 30 IN. CIRCLE. <br />4.PROVIDE A 12"x12" MINIMUM ACCESS PANEL TO BATHTUB TRAP CONNECTION UNLESS PLUMBING IS <br />WITHOUT SLIP JOINTS (CPC 405.2). <br />5.ALL TOILETS SHALL BE 1.28 GPF, SHOWERHEADS 2.0 GPM, AND FAUCETS 1.2 GPM, KITCHEN FAUCET <br />1.8 GPM. <br />6.FOR SHOWERS OR TUB-SHOWERS MAX. TEMPERATURE OF 120 DEGREE TO BE PROVIDED BY THE <br />USE CONTROL VALVE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE. <br />7.ALL GLAZING IN ALL DOORS, BATH/SHOWER ENCLOSURES MUST BE IDENTIFIED BY A LABEL AS A <br />SAFETY GLAZING. <br />8.WALL COVERING IN SHOWERS AND TUBS TO BE CEMENT PLASTER OR TILE EQUAL TO 72" ABOVE <br />DRAIN. ENCLOSURES MUST BE OF APPROVED SAFETY GLAZING AND DOORS MUST SWING OUT OF <br />SHOWERS. WINDOWS IN ENCLOSURE WALLS SHALL BE LABELED SAFETY GLAZING WHEN LESS THAN <br />60" ABOVE THE DRAIN, TYPICAL FOR ALL BATHROOMS. <br />9.GREEN BOARD GYPSUM OR WATER RESISTANT GYPSUM BOARD SHALL NOT BE USED AS BACKING <br />FOR CEILING FINISH INSIDE BATHROOM DUE TO CONDENSATION OR VAPOR. <br />10.WATER HEATER: SIZE PER TITLE 24 WITH VENT THROUGH OUTSIDE. PROVIDE P&T RELIEF VALVE ON <br />WATER HEATER. PROVIDE SMITTY PAN WITH DRAIN INSULATION/CLEARANCE PER MANUFACTURER <br />SPECS. WATER HEATER TANK (IF USED) MUST BE ADEQUATELY BRACED TO RESIST SEISMIC <br />FORCES: PROVIDE 2 STRAPS, 1 STRAP AT TOP 1/3 OF TANK AND 1 STRAP AT BOTTOM 1/3 OF THE <br />TANK. <br />11.PLUMBING VENT TERMINATIONS SHALL BE AT LEAST 10' FROM FRESH AIR INTAKE OR VENTILATION. <br />12.B-VENTS SHALL TERMINATE AT LEAST 4' FROM FRESH AIR INTAKE OR VENTILATION. <br />WINDOW SCHEDULE <br />WINDOWS' U-FACTOR AND SHGC PER TITLE 24 SPECIFICATIONS. <br />A 48"x48" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME <br />B 60"x24" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME <br />C 36"x36" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME <br />DOOR SCHEDULE <br />1 30"x80" HOLLOW CORE DOOR <br />2 36"x80" SOLID CORE ENTRY DOOR W/ TEMPERED GLASS <br />3 60"x80" CLOSET SLIDING DOOR <br />4 72"x80" CLOSET SLIDING DOOR <br />5 24"x80" DOOR WITH LOUVERS AS DETAILED HEREON <br />BATHROOM NOTE <br />CEMENT, FIBER CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR <br />FIBER-REINFORCED GYPSUM BACKERS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND <br />SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS. <br />(N <br />) <br /> <br />F <br />L <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />SHEET <br />A3 <br />REVISION <br />DATE BY <br />1 <br />2 <br />3 <br />PROJECT ENGINEER <br />BEN PHAN <br />10822 WOODWARD LN <br />GARDEN GROVE, CA 92840 <br />TEL: (714) 251 4537 <br />ELEC. BOX HEIGHT <br />N.T.S. <br />AGING-IN-PLACE NOTES <br />A. REINFORCEMENT FOR GRAB BARS - AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH <br />REINFORCEMENT INSTALLED IN ACCORDANCE WITH CRC R327.1. <br />1) REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING <br />AGENCY. <br />2) REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER (1-1/2 INCH BY 7-1/4 INCH ACTUAL <br />DIMENSION) OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. <br />REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES AND 39-1/4 INCHES ABOVE THE FINISHED FLOOR, FLUSH <br />WITH THE WALL FRAMING. <br />3) WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE <br />WALL AND THE BACK WALL. <br />4) SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />5) BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE <br />BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE <br />PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. <br />6) WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB <br />BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR <br />ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. <br />7) REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND <br />BATHTUB WALL PANELS WITH INTEGRAL FACTORY- INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED <br />REINFORCEMENT FOR GRAB BARS IS PROVIDED. <br />8) SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS SHALL BE <br />PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE <br />METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />9) BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF <br />REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB <br />BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />10) REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS INSTALLED ON <br />CONCRETE SLAB FLOORS. <br />B. DOCUMENTATION FOR GRAB BAR REINFORCEMENT - INFORMATION AND/OR DRAWINGS IDENTIFYING THE <br />LOCATION OF GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND MAINTENANCE MANUAL IN <br />ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.4. (CRC R327.1.1.1) <br />C. ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS - ELECTRICAL RECEPTACLE OUTLETS, <br />SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO <br />BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET <br />BOX AND NOT LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. <br />(CRC R327.1.2). EXCEPTIONS: <br />1) DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON CEILING FANS AND <br />CEILING LIGHTS; AND CONTROLS LOCATED ON APPLIANCES. <br />2) RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE ON A WALL SPACE WHERE THE <br />DISTANCE BETWEEN THE FINISHED FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A WINDOW, <br />IS LESS THAN 15 INCHES. <br />D. DOORBELL BUTTONS - DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES <br />(1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. <br />WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 <br />INCHES (1219.2 MM) MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR <br />CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR <br />OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. (CRC R327.1.4) <br />WATER HEATER - DRYER - <br />F.A.U. DOOR DETAIL <br />N.T.S. <br />SD <br />LEGEND <br />GFCI RECEPTACLE <br /> WR GFCI WEATHER RESISTANT RECEPTACLE <br />TAMPER RESISTANT RECEPTACLE, 120V SINGLE PHASE, 20A, <br /> CONTROLLED BY ARC-FAULT CIRCUIT INTERRUPTER (AFCI) <br />240V DEDICATED OUTLET, AMPERAGE AS INDICATED IN PLAN <br />CEILING-MOUNT RECESS LIGHT <br />OUTDOOR WALL-MOUNT LIGHT FIXTURE W/ PHOTOCELL & MOTION SENSOR <br /> $LIGHT SWITCH WITH DIMMER (D) WHERE INDICATED <br /> $3 3-WAY LIGHT SWITCH WITH DIMMER (D) WHERE INDICATED <br /> $vs VACANCY SENSOR LIGHT SWITCH <br /> $W/D WASHER/DRYER DISCONNECT SWITCH, 20A, INSTALL PER MANU. SPECS. <br />EXHAUST FAN (100 CFM MINIMUM) W/ HUMIDITY CONTROL <br />IN-SINK DISPOSAL <br />AIR REGISTER ON CEILING <br />SMOKE DETECTOR <br />CARBON MONOXIDE DETECTOR <br />4" DRYER VENT W/ DAMPER, TERMINATED 30" ABOVE F.F. ON OUTSIDE WALL <br />4" DRYER EXHAUST VENT W/ APPROVED WALL STRAP, TERMINATED ABOVE <br />ROOF THROUGH APPROVED FLASHING, VENT 14' LONG MAX., 2 ELBOWS MAX. <br /> W/H 240V-50 GAL. WATER HEATER TANK, RHEEMTM MODEL XE50T10H22U <br /> W CLOTHES WASHER <br /> D CLOTHES DRYER <br />HOSE BIB WITH ANTI-SIPHON VALVE <br />AIR RETURN ON CEILING <br />ROOF-MOUNT ATTIC VENT <br />IAQ FAN (PER TITLE 24), 80 CFM MINIMUM <br />CO <br />18" <br />18" <br />PER PLAN <br />100 SQ. IN. MIN. ON <br />EACH LOUVER @ <br />TOP AND BOTTOM <br />80" <br />15" <br />MIN. <br />48" <br />MAX. <br />F.F. <br />OW <br />N <br />E <br />R <br />SU <br /> <br />Q <br />U <br />A <br />N <br /> <br />L <br />E <br />TE <br />L <br />: <br /> <br />( <br />9 <br />4 <br />9 <br />) <br /> <br />5 <br />2 <br />9 <br /> <br />1 <br />9 <br />9 <br />9 <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />MA <br />I <br />N <br /> <br />U <br />N <br />I <br />T <br />: <br /> <br />7 <br />4 <br />6 <br /> <br />S <br /> <br />D <br />E <br />M <br />I <br />N <br />G <br /> <br />S <br />T <br />JA <br />D <br />U <br />: <br /> <br />7 <br />4 <br />6 <br /> <br />S <br /> <br />D <br />E <br />M <br />I <br />N <br />G <br /> <br />S <br />T <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />AD <br />U <br />: <br /> <br />7 <br />4 <br />6 <br /> <br />S <br /> <br />D <br />E <br />M <br />I <br />N <br />G <br /> <br />S <br />T <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />3 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />DATE 03/25/2024 <br />CO <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />O <br />F <br /> <br />4 <br />4 <br />8 <br /> <br />S <br />F <br /> <br />A <br />D <br />U <br />AN <br />D <br /> <br />4 <br />4 <br />2 <br /> <br />S <br />F <br /> <br />J <br />A <br />D <br />U <br />NEW WALL, 2x4 STUDS @ <br />16" O.C. U.N.O. <br />EXISTING STUD WALL <br />WALL LEGEND <br />WALL W/ STC-50 AND 1-HOUR FIRE RATED <br />746 S Deming St, Unit# 2 <br />& 31/23/2025