Laserfiche WebLink
GSPublisherVersion 0.0.100.100 <br />4 <br />7 <br />1 <br />5 <br />& <br />4 <br />7 <br />1 <br />7 <br /> <br />W <br />. <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />, <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />N <br />E <br />W <br /> <br />A <br />D <br />D <br />I <br />T <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />N <br />E <br />W <br /> <br />A <br />D <br />U <br />sheet title: <br />sheet number: <br />REVISIONS <br />NO.DATE DESCRIPTION <br />DESIGN <br />DRAWN <br />ISSUED <br />APPROVED <br />NS <br />JT <br />A2.2 <br />PROPOSED ELECTRICAL <br />PLAN <br />N&NC <br />12 <br />4 <br />5 <br /> <br />EA <br />S <br />T <br /> <br />WA <br />L <br />N <br />U <br />T <br /> <br />ST <br />R <br />E <br />E <br />T <br />, <br />ST <br />E <br /> <br />11 <br />2 <br />PA <br />S <br />A <br />D <br />E <br />N <br />A <br />, <br />CA <br /> <br /> <br />91 <br />1 <br />0 <br />6 <br />S <br />L.1 <br />L.2 <br />CM SD <br />FAN <br />CM <br />SD <br />SD <br />L.1 <br />L.1 <br />L.1 <br />L.1 <br />L.1 <br />L.1 <br />L.1L.1 <br />L.1L.1 <br />L.1 <br />L.1 <br />L.1 <br />L.1 <br />L.1 <br />L.1 <br />S SS <br />SS <br />SSS <br />SS <br />AFCI <br />AFCI <br />AFCI AFCI AFCI AFCI <br />AFCI <br />AFCIAFCIAFCI <br />AFCI <br />GFI <br />GFI <br />AFCI <br />GFI GFI <br />GFI <br />GFI <br />1 <br />A 2 .5 <br />1 <br />A 2 .5 <br />FAN <br />SDSD <br />SD <br />SD <br />SD <br />CM <br />WWF <br />240VHEAT PUMP <br />TANKLESS HEAT PUMP <br />WATER HEATER <br />(N) <br />MI <br />N <br />I <br /> <br />SP <br />L <br />I <br />T <br />(N) MINI SPLIT <br />L.1L.1 <br />GFI GFI GFI GFI GFI <br />S NEW SWITCH - BATHROOM SHALL HAVE AN <br />OCCUPANCY SENSOR SWITCHES - FAN TO <br />CONTINUE OPERATION FOR 10 MINUTES <br />AFTER LIGHT SWITCHES OFF. <br />HIGH EFFICACY EXTERIOR LED LIGHT- <br />WITH ON/OFF SWITCH AS WELL AS <br />PHOTOCONTROL AND AUTOMATIC TIME <br />SWITCH CONTROL <br />L.1 <br />L.2 <br />HIGH EFFICACY RECESSED <br />LIGHT (40W LED) <br />HIGH EFFICACY WATER-RESISTANT <br /> RECESSED LIGHT <br />WALL SCONCE OUTSIDES <br />PENDANT LIGHTP <br />LEGEND <br />NEW DOORD1 <br />CARBON MONOXIDE DETECTORCM <br />SMOKE DETECTORSD <br />MIN. 50 CFM MECHANICAL <br />EXHAUST FAN - ENERGYSTAR <br />WITH HUMIDISTAT <br />FAN <br />EXISTING STUD WALL TO REMAIN <br />NEW WINDOW <br />NEW STUD WALL <br />W 1 <br />ALL POWER AND LIGHTING OUTLETS IN FAMILY ROOMS , <br />PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, <br />RECREATION ROOMS , HALLWAYS AND SIMILAR AREAS ARE <br />TO BE PROTECTED BY A "COMBINATION AFCI BREAKER." <br />KITCHENS, BATHROOMS, AND BASEMENTS ARE EXEMPT <br />FROM THIS REQUIREMENT. <br />1 HOUR FIRE RATED WALL <br />WHOLE HOUSE FAN <br />WWF <br />GENERAL NOTES: <br />A. PANEL LOCATIONS <br />PANELS SHALL NOT BE LOCATED IN THE VICINITY OF EASILY IGNITABLE MATERIAL, SUCH AS <br />CLOTHES CLOSETS LCEC 240-24(D), OR IN BATHROOMS [CEC <br />240- 24(E)]. <br />В. NON-METTALIC SHEATHED CABLE [CEC 334] <br />NON-METALLIC SHEATHED CABLE SHALL BE: <br />1. PROTECTED BY RIGID METAL CONDUIT, INTERMEDIATE METAL CONDUIT , ELECTRICAL <br />METALLIC TUBING, SCHEDULE 80 PVC CONDUIT, TYPE RTRC MARKED WITH THE SUFFIX -XW, <br />OR OTHER MEANS WHEN CABLE IS EXPOSED OR SUBJECT TO PHYSICAL DAMAGE. [CEC <br />334.15(B)] <br />2. ROTECTED BY A 1/16-INCH STEEL PLATE OR SLEEVE OR BE NOT LESS THAN 1-1/4 INCH <br />FROM THE NEAREST EDGE OF THE FRAMING MEMBER, WHEN INSTALLED THROUGH <br />FRAMING MEMBERS. STEEL PLATES OR SLEEVES ARE REQUIRED ON ALL DOUBLE SHEAR <br />WALLS WHEN CABLE IS INSTALLED EITHER THROUGH OR PARALLEL TO FRAMING MEMBERS <br />[CEC 334.17, 300.4]. <br />3. PROTECTED BY GUARD STRIPS WITHIN 6 FEET OF AN ATTIC ACCESS WHEN NO <br />PERMANENT STAIRS OR LADDERS ARE PROVIDED [CEC 334.23, 320.23] . <br />4. PROTECTED BY GUARDI STRIPSLINTTHETENTIRE ATTIC WHENTPERMANENT <br />STAIRS OR LADDERS ARE PROVIDED. ACCESS PANELS OR DOORS FROM THE SECOND <br />FLOOR INTO THE ATTIC ARE CONSIDERED PERMANENT ACCESS AND GUARD STRIPS ARE <br />REQUIRED IN THE ENTIRE ATTIC [CEC 320.23]. <br />5. HAVE A BENDING RADIUS NOT LESS THAN 5 TIMES THE DIAMETER OF THE CABLE [CEC <br />334.24]. <br />6. SUPPORTED AT INTERVALS NOT EXCEEDING 4-1/2 FEET AND WITHIN 12''H OF EVERY <br />OUTLET BOX, JUNCTION BOX, CABINET OR FITTING [CEC 334.30]. <br />C. CIRCUITS AND RECEPTACLES <br />1. TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED AS SPECIFIED IN DWELLING <br />UNITS IN ALL AREAS SPECIFIED IN 210.52 AND 550.13. [CEC 406.12] <br />2. RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY <br />WALL SPACE IS MORE THAN 6 FT. FROM AN OUTLET, INCLUDING ANY WALL SPACE 2 FT. WIDE <br />OR GREATER. NOTE: A FIXED PANEL OF A SLIDING GLASS DOOR IS CONSIDERED WALL <br />SPACE. [CEC 210.52(A)]. <br />3. IN KITCHENS, BREAKFAST ROOMS, PANTRIES AND DINING ROOMS A MINIMUM OF 2-20A <br />CIRCUITS SHALL BE PROVIDED [CEC 210.11(C)(1)]. COUNTER SPACE RECEPTACLES SHALL BE <br />GFCI [CEC 210.8(A)] AND INSTALLED: <br />- AT EACH WALL COUNTER SPACE THAT IS 12 IN. OR GREATER [CEC 210.52(C)(1)] : <br />- NO MORE THAN 48 IN. OC. [CEC 210.52 (C)(1)]; <br />- MAXIMUM 24 IN. FROM THE END OF THE COUNTER [CEC 210.52 (C)(1)]; <br />- MAXIMUM 20 IN. ABOVE COUNTER SURFACE [CEC 210.52(C)(5)] <br />-ON ISLAND COUNTER SPACES (ONE RECEPTACLE MIN.) NOT MORE THAN 12 IN. BELOW <br />COUNTER SURFACE [CEC 210.52 (C)(5) EXCEPTION]. AN ISLAND WITH LESS THAN 12*H <br />BEHIND A RANGE TOP OF SINK IS CONSIDERED AS DIVIDING THE COUNTERTOP INTO TWO <br />SEPARATE SPACES [CEC 210.52(C)(2)]. <br />4. BATHROOMS SHALL HAVE A SEPARATE 20A CIRCUIT [CEC 210.11 (C)(3)] WITH AT LEAST ONE <br />GFCI WALL RECEPTACLE WITHIN 36 IN. OF EACH BASIN [CEC 210.8(A)(1): CEC 210.52(D)]. <br />5, LAUNDRY ROOMS SHALL HAVE A SEPARATE 20A CIRCUIT WITH AT LEAST ONE RECEPTACLE <br />SHALL BE PROVIDED [CEC 210.11(C)(2)]. ALL RECEPTACLES WITHIN 6 FT. OF THE SINK SHALL <br />BE GFCI ICEC 210.8(A)(7)]. <br />6. IN GARAGES, AT LEAST ONE GFCI RECEPTACLE SHALL BE PROVIDED [CEC 210,52(G)]. ALL <br />OTHER GARAGE RECEPTACLES EXCEPT THOSE DEDICATED TO AN APPLIANCE OR THAT ARE <br />NOT READILY ACCESSIBLE SHALL BE GFCI. [CEC 210.8(A)(2)]. <br />7. IN HALLWAYS OF 10 FT. OR MORE IN LENGTH, AT LEAST ONE RECEPTACLE SHALL BE <br />PROVIDED [CEC 210.52(H)]. <br />8. OUTDOOR OUTLETS SHALL BE GFCI [CEC 210.8(A) (3)]. ONE OUTLET SHALL BE INSTALLED <br />AT THE FRONT OF THE DWELLING AND ONE AT THE REAR OF THE DWELLING. BALCONIES, <br />DECKS, AND PORCHES THAT ARE ATTACHED TO THE DWELLING UNIT AND ARE ACCESSIBLE <br />FROM INSIDE THE DWELLING UNIT SHALL HAVE AT LEAST ONE OUTLET, RECEPTACLES SHALL <br />BE ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN 6-1/2 FT. ABOVE GRADE OR WALKING <br />SURFACE [CEC 210.52 (E)] <br />9. ALL CRAWL SPACE RECEPTACLES SHALL BE GFCI [CEC 210.8(A)(4)] <br />10. ALL UNFINISHED BASEMENT RECEPTACLES SHALL BE GFCI UNLESS THEY ARE NOT <br />READILY ACCESSIBLE OR ARE SERVICE A DEDICATED APPLIANCE [CEC 210.8(A) (5)]. <br />11. ALL RECEPTACLES WITHIN 6 FT. OF A WET BAR SHALL BE GFCI [CEC 210.8(4)(7)]. <br />12. ALL RECEPTACLES ON 15A OR 20A BRANCH CIRCUITS THAT SUPPLY FAMILY ROOMS , <br />DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, <br />RECREATION ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE <br />PROTECTED BY COMBINATION- TYPE ARC-FAULT CIRCUIT INTERRUPTERS (AFCI), INCLUDING <br />SWITCHED OUTLETS [CEC 210.12 (A)]. <br />13. ALL RECEPTACLES SERVING APPLIANCES OR MOTORS WITH A RATING OF 1 <br />HP OR 6 AMPS SHALL BE ON A SEPARATE CIRCUIT . <br />14. FOR HVAC EQUIPMENT , A SEPARATE 15A OR 20A CIRCUIT WITH AN ACCESSIBLE <br />RECEPTACLE AT THE EQUIPMENT SHALL BE PROVIDED WITHIN 25 FT. OF THE EQUIPMENT <br />[CEC 210.63]. IF LOCATED IN AN UNDER-FLOOR AREA, THE RECEPTACLE SHALL BE GFCI [CEC <br />210.8(4)]. <br />15. BASEMENTS, GARAGES AND ACCESSORY BUILDINGS. FOR A ONEFAMILY <br />DWELLING, AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED IN THE AREAS <br />SPECIFIED IN 210.52(G)(1) THROUGH (3)/ THESE RECEPTACLES SHALL BE IN ADDITION TO <br />RECEPTACLES REQUIRED FOR SPECIFIC EQUIPMENT. [CEC210.521 <br />(1) GARAGES, IN EACH ATTACHED GARAGE AND IN EACH DETACHED GARAGE WITH <br />ELECTRICAL POWER. THE BRANCH CIRCUIT SUPPLYING THIS RECEPTACLE(S) SHALL NOT <br />SUPPLY OUTLETS OUTSIDE OF THE GARAGE, AT LEAST ONE RECEPTACLE OUTLET SHALL BE <br />INSTALLED FOR EACH CAR SPACE. <br />(2)ACCESSORY BUILDINGS. IN EACH ACCESSORY BUILDING WITH ELECTRIC POWER. <br />(3) BASEMENT. IN EACH SEPARATE UNFINISHED PORTION OF A BASEMENT . <br />D. LIGHTING [CEC 210.70] <br />1. SWITCHED LIGHTING SHALL BE INSTALLED IN: <br />- ALL HABITABLE ROOMS, BATHROOMS, HALLWAYS, AND STAIRWAYS AT EACH LEVEL , <br />- GARAGES, <br />- AT ALL OUTDOOR ENTRANCES AND EXITS, <br />- IN ALL ATTICS, UNDER FLOOR AREAS, UTILITY ROOMS AND BASEMENTS USED FOR <br />STORAGE <br />- NEAR HVAC EQUIPMENT IN ATTIC, UNDER FLOOR AREAS, ROOMS OR BASEMENTS. WITH A <br />SWITCH AT THE ACCESS POINT. <br />2. LIGHTING INSTALLED IN A CLOSET SHALL BE A SURFACE MOUNTED OR RECESSED <br />FLUORESCENT FIXTURE OR A SURFACE MOUNTED INCANDESCENT FIXTURE WITH <br />COMPLETELY ENCLOSED LAMPS OR RECESSED INCANDESCENT FIXTURE WITH COMPLETELY <br />ENCLOSED LAMPS. <br />SURFACE INCANDESCENT LIGHTING SHALL BE INSTALLED A MINIMUM OF 12 IN. FROM THE <br />NEAREST POINT OF A STORAGE SPACE. SURFACE FLUORESCENT LIGHTING AND RECESSED <br />LIGHTING SHALL BE INSTALLED A MINIMUM OF 6 IN. FROM THE NEAREST POINT OF A <br />STORAGE SPACE. [CEC 410.16(C)] <br />E. FANS <br />EACH BATHROOM CONTAINING A BATHTUB, SHOWER, OR BATHTUB/SHOWER COMBINATION <br />SHALL BE MECHANICALLY VENTILATED FOR PURPOSES OF. HUMIDITY CONTROL IN <br />ACCORDANCE WITH THE CALIFORNIA MECHANICAL CODE AND THE CALIFORNIA GREEN <br />BUILDING STANDARDS CODE. <br />F. SMOKE ALARMS <br />IN NEW CONSTRUCTION, SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM <br />THE BUILDING WIRING. THE WIRING SHALL BE PERMANENT AND INSTALLED WITHOUT A <br />DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION <br />[CRC R314.4, CBC 907.2.10,5]. <br />CLOTHES DRYER NOTES: <br />1. A MINIMUM OF 4" MOISTURE EXHAUST DUCT MUST BE PROVIDED [MC 504.4.2] <br />2. DRYER EXHAUST CANNOT EXCEED 14 FT WITH A MAX OF TWO 90 DEGREE ELBOWS LCMC <br />504.4.2.1] <br />3. A FLEXIBLE DUCT CANNOT EXTEND MORE THAN 6 FT. AND CANNOT BE CONCEALED [CMC <br />504.4.2.2] <br />PLUMBING NOTE: <br />PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(c), ALL NON- COMPLIANT PLUMBING FIXTURES <br />SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES. <br />NOTE: <br />1. INTERIOR STAIRWAYS SHALL BE PROVIDED WITH ARTIFICIAL LIGHT SOURCE LOCATED IN THE <br />IMMEDIATE VICINITY OF EACH LANDING OF THE STAIRWAY, CAPABLE OF ILLUMINATING TREADS AND <br />LANDINGS AT LEAST 1-FOOT CANDLE MEASURED AT THE CENTER OF TREADS AND, LANDINGS. (CRC <br />R303.7, CBC 1204.4). <br />BATHROOM NOTES: <br />1. THE WATER CLOSET SHALL HAVE A CLEARANCE OF 30 INCHES WIDE (15 INCHES ON CENTER) AND 24 <br />INCHES IN FRONT. (CPC 402.5) WHERE THE WATER CLOSET (OR OTHER PLUMBING FIXTURE COMES <br />INTO CONTACT WITH THE WALL OR FLOOR, THE JOINT SHALL BE CAULKED AND SEALED TO BE <br />WATERTIGHT. (CPC 402.2) <br />2. SHOWER STALLS SHALL BE A MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES, BE CAPABLE <br />OF ENCOMPASSING A 30 INCH DIAMETER CIRCLE. ANY DOORS SHALL SWING OUT OF THE ENCLOSURE <br />HAVE A CLEAR OPENING OF 22 INCHES MINIMUM. (CPC 408.5, 408.6) <br />PLUMBING NOTE: <br />PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(c), ALL NON- COMPLIANT PLUMBING FIXTURES <br />SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES. <br />NOTES: <br />9. Water Heating system (water heater) ˆ¢â‹â (Section 150.0(n)) <br />a. Systems using gas or propane water heaters to serve individual dwelling units shall designate a space at least 2.5 feet by 2.5 feet wide and 7 feet tall <br />suitable for the future installation of a heat pump water heater (HPWH) by meeting either A or B listed under Section 150.0(n). <br />A. If the designated space is within 3 feet from the water heater: <br />i. A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit, <br />within 3 feet from the water heater. <br />Heat pump space heater (furnace) ready: System using gas furnace to serve individual dwelling units shall include a dedicated 240 volt, minimum 30 amps <br />branch circuit wiring shall be installed within 3-ft from the furnace for a future heat pump space heater installation <br />Electric cooktop ready: System using gas to serve individual dwelling units shall include the following shall include a dedicated 240 volt, minimum 50 amps <br />circuit wiring shall be installed within 3-ft from the cooktop for a future electric cooktop installation. <br />- 1/4" = 1'-0" <br />1 PROPOSED ELECTRICAL PLAN <br />SCALE: <br />NO <br />R <br />T <br />H