<br />sheet title:
<br />sheet number:
<br />REVISIONS
<br />NO.DATE DESCRIPTION
<br />DESIGN
<br />DRAWN
<br />ISSUED
<br />APPROVED
<br />NS
<br />JT
<br />A2.2
<br />PROPOSED ELECTRICAL
<br />PLAN
<br />N&NC
<br />12
<br />4
<br />5
<br />
<br />EA
<br />S
<br />T
<br />
<br />WA
<br />L
<br />N
<br />U
<br />T
<br />
<br />ST
<br />R
<br />E
<br />E
<br />T
<br />,
<br />ST
<br />E
<br />
<br />11
<br />2
<br />PA
<br />S
<br />A
<br />D
<br />E
<br />N
<br />A
<br />,
<br />CA
<br />
<br />
<br />91
<br />1
<br />0
<br />6
<br />S
<br />L.1
<br />L.2
<br />CM SD
<br />FAN
<br />CM
<br />SD
<br />SD
<br />L.1
<br />L.1
<br />L.1
<br />L.1
<br />L.1
<br />L.1
<br />L.1L.1
<br />L.1L.1
<br />L.1
<br />L.1
<br />L.1
<br />L.1
<br />L.1
<br />L.1
<br />S SS
<br />SS
<br />SSS
<br />SS
<br />AFCI
<br />AFCI
<br />AFCI AFCI AFCI AFCI
<br />AFCI
<br />AFCIAFCIAFCI
<br />AFCI
<br />GFI
<br />GFI
<br />AFCI
<br />GFI GFI
<br />GFI
<br />GFI
<br />1
<br />A 2 .5
<br />1
<br />A 2 .5
<br />FAN
<br />SDSD
<br />SD
<br />SD
<br />SD
<br />CM
<br />WWF
<br />240VHEAT PUMP
<br />TANKLESS HEAT PUMP
<br />WATER HEATER
<br />(N)
<br />MI
<br />N
<br />I
<br />
<br />SP
<br />L
<br />I
<br />T
<br />(N) MINI SPLIT
<br />L.1L.1
<br />GFI GFI GFI GFI GFI
<br />S NEW SWITCH - BATHROOM SHALL HAVE AN
<br />OCCUPANCY SENSOR SWITCHES - FAN TO
<br />CONTINUE OPERATION FOR 10 MINUTES
<br />AFTER LIGHT SWITCHES OFF.
<br />HIGH EFFICACY EXTERIOR LED LIGHT-
<br />WITH ON/OFF SWITCH AS WELL AS
<br />PHOTOCONTROL AND AUTOMATIC TIME
<br />SWITCH CONTROL
<br />L.1
<br />L.2
<br />HIGH EFFICACY RECESSED
<br />LIGHT (40W LED)
<br />HIGH EFFICACY WATER-RESISTANT
<br /> RECESSED LIGHT
<br />WALL SCONCE OUTSIDES
<br />PENDANT LIGHTP
<br />LEGEND
<br />NEW DOORD1
<br />CARBON MONOXIDE DETECTORCM
<br />SMOKE DETECTORSD
<br />MIN. 50 CFM MECHANICAL
<br />EXHAUST FAN - ENERGYSTAR
<br />WITH HUMIDISTAT
<br />FAN
<br />EXISTING STUD WALL TO REMAIN
<br />NEW WINDOW
<br />NEW STUD WALL
<br />W 1
<br />ALL POWER AND LIGHTING OUTLETS IN FAMILY ROOMS ,
<br />PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,
<br />RECREATION ROOMS , HALLWAYS AND SIMILAR AREAS ARE
<br />TO BE PROTECTED BY A "COMBINATION AFCI BREAKER."
<br />KITCHENS, BATHROOMS, AND BASEMENTS ARE EXEMPT
<br />FROM THIS REQUIREMENT.
<br />1 HOUR FIRE RATED WALL
<br />WHOLE HOUSE FAN
<br />WWF
<br />GENERAL NOTES:
<br />A. PANEL LOCATIONS
<br />PANELS SHALL NOT BE LOCATED IN THE VICINITY OF EASILY IGNITABLE MATERIAL, SUCH AS
<br />CLOTHES CLOSETS LCEC 240-24(D), OR IN BATHROOMS [CEC
<br />240- 24(E)].
<br />В. NON-METTALIC SHEATHED CABLE [CEC 334]
<br />NON-METALLIC SHEATHED CABLE SHALL BE:
<br />1. PROTECTED BY RIGID METAL CONDUIT, INTERMEDIATE METAL CONDUIT , ELECTRICAL
<br />METALLIC TUBING, SCHEDULE 80 PVC CONDUIT, TYPE RTRC MARKED WITH THE SUFFIX -XW,
<br />OR OTHER MEANS WHEN CABLE IS EXPOSED OR SUBJECT TO PHYSICAL DAMAGE. [CEC
<br />334.15(B)]
<br />2. ROTECTED BY A 1/16-INCH STEEL PLATE OR SLEEVE OR BE NOT LESS THAN 1-1/4 INCH
<br />FROM THE NEAREST EDGE OF THE FRAMING MEMBER, WHEN INSTALLED THROUGH
<br />FRAMING MEMBERS. STEEL PLATES OR SLEEVES ARE REQUIRED ON ALL DOUBLE SHEAR
<br />WALLS WHEN CABLE IS INSTALLED EITHER THROUGH OR PARALLEL TO FRAMING MEMBERS
<br />[CEC 334.17, 300.4].
<br />3. PROTECTED BY GUARD STRIPS WITHIN 6 FEET OF AN ATTIC ACCESS WHEN NO
<br />PERMANENT STAIRS OR LADDERS ARE PROVIDED [CEC 334.23, 320.23] .
<br />4. PROTECTED BY GUARDI STRIPSLINTTHETENTIRE ATTIC WHENTPERMANENT
<br />STAIRS OR LADDERS ARE PROVIDED. ACCESS PANELS OR DOORS FROM THE SECOND
<br />FLOOR INTO THE ATTIC ARE CONSIDERED PERMANENT ACCESS AND GUARD STRIPS ARE
<br />REQUIRED IN THE ENTIRE ATTIC [CEC 320.23].
<br />5. HAVE A BENDING RADIUS NOT LESS THAN 5 TIMES THE DIAMETER OF THE CABLE [CEC
<br />334.24].
<br />6. SUPPORTED AT INTERVALS NOT EXCEEDING 4-1/2 FEET AND WITHIN 12''H OF EVERY
<br />OUTLET BOX, JUNCTION BOX, CABINET OR FITTING [CEC 334.30].
<br />C. CIRCUITS AND RECEPTACLES
<br />1. TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED AS SPECIFIED IN DWELLING
<br />UNITS IN ALL AREAS SPECIFIED IN 210.52 AND 550.13. [CEC 406.12]
<br />2. RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY
<br />WALL SPACE IS MORE THAN 6 FT. FROM AN OUTLET, INCLUDING ANY WALL SPACE 2 FT. WIDE
<br />OR GREATER. NOTE: A FIXED PANEL OF A SLIDING GLASS DOOR IS CONSIDERED WALL
<br />SPACE. [CEC 210.52(A)].
<br />3. IN KITCHENS, BREAKFAST ROOMS, PANTRIES AND DINING ROOMS A MINIMUM OF 2-20A
<br />CIRCUITS SHALL BE PROVIDED [CEC 210.11(C)(1)]. COUNTER SPACE RECEPTACLES SHALL BE
<br />GFCI [CEC 210.8(A)] AND INSTALLED:
<br />- AT EACH WALL COUNTER SPACE THAT IS 12 IN. OR GREATER [CEC 210.52(C)(1)] :
<br />- NO MORE THAN 48 IN. OC. [CEC 210.52 (C)(1)];
<br />- MAXIMUM 24 IN. FROM THE END OF THE COUNTER [CEC 210.52 (C)(1)];
<br />- MAXIMUM 20 IN. ABOVE COUNTER SURFACE [CEC 210.52(C)(5)]
<br />-ON ISLAND COUNTER SPACES (ONE RECEPTACLE MIN.) NOT MORE THAN 12 IN. BELOW
<br />COUNTER SURFACE [CEC 210.52 (C)(5) EXCEPTION]. AN ISLAND WITH LESS THAN 12*H
<br />BEHIND A RANGE TOP OF SINK IS CONSIDERED AS DIVIDING THE COUNTERTOP INTO TWO
<br />SEPARATE SPACES [CEC 210.52(C)(2)].
<br />4. BATHROOMS SHALL HAVE A SEPARATE 20A CIRCUIT [CEC 210.11 (C)(3)] WITH AT LEAST ONE
<br />GFCI WALL RECEPTACLE WITHIN 36 IN. OF EACH BASIN [CEC 210.8(A)(1): CEC 210.52(D)].
<br />5, LAUNDRY ROOMS SHALL HAVE A SEPARATE 20A CIRCUIT WITH AT LEAST ONE RECEPTACLE
<br />SHALL BE PROVIDED [CEC 210.11(C)(2)]. ALL RECEPTACLES WITHIN 6 FT. OF THE SINK SHALL
<br />BE GFCI ICEC 210.8(A)(7)].
<br />6. IN GARAGES, AT LEAST ONE GFCI RECEPTACLE SHALL BE PROVIDED [CEC 210,52(G)]. ALL
<br />OTHER GARAGE RECEPTACLES EXCEPT THOSE DEDICATED TO AN APPLIANCE OR THAT ARE
<br />NOT READILY ACCESSIBLE SHALL BE GFCI. [CEC 210.8(A)(2)].
<br />7. IN HALLWAYS OF 10 FT. OR MORE IN LENGTH, AT LEAST ONE RECEPTACLE SHALL BE
<br />PROVIDED [CEC 210.52(H)].
<br />8. OUTDOOR OUTLETS SHALL BE GFCI [CEC 210.8(A) (3)]. ONE OUTLET SHALL BE INSTALLED
<br />AT THE FRONT OF THE DWELLING AND ONE AT THE REAR OF THE DWELLING. BALCONIES,
<br />DECKS, AND PORCHES THAT ARE ATTACHED TO THE DWELLING UNIT AND ARE ACCESSIBLE
<br />FROM INSIDE THE DWELLING UNIT SHALL HAVE AT LEAST ONE OUTLET, RECEPTACLES SHALL
<br />BE ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN 6-1/2 FT. ABOVE GRADE OR WALKING
<br />SURFACE [CEC 210.52 (E)]
<br />9. ALL CRAWL SPACE RECEPTACLES SHALL BE GFCI [CEC 210.8(A)(4)]
<br />10. ALL UNFINISHED BASEMENT RECEPTACLES SHALL BE GFCI UNLESS THEY ARE NOT
<br />READILY ACCESSIBLE OR ARE SERVICE A DEDICATED APPLIANCE [CEC 210.8(A) (5)].
<br />11. ALL RECEPTACLES WITHIN 6 FT. OF A WET BAR SHALL BE GFCI [CEC 210.8(4)(7)].
<br />12. ALL RECEPTACLES ON 15A OR 20A BRANCH CIRCUITS THAT SUPPLY FAMILY ROOMS ,
<br />DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,
<br />RECREATION ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE
<br />PROTECTED BY COMBINATION- TYPE ARC-FAULT CIRCUIT INTERRUPTERS (AFCI), INCLUDING
<br />SWITCHED OUTLETS [CEC 210.12 (A)].
<br />13. ALL RECEPTACLES SERVING APPLIANCES OR MOTORS WITH A RATING OF 1
<br />HP OR 6 AMPS SHALL BE ON A SEPARATE CIRCUIT .
<br />14. FOR HVAC EQUIPMENT , A SEPARATE 15A OR 20A CIRCUIT WITH AN ACCESSIBLE
<br />RECEPTACLE AT THE EQUIPMENT SHALL BE PROVIDED WITHIN 25 FT. OF THE EQUIPMENT
<br />[CEC 210.63]. IF LOCATED IN AN UNDER-FLOOR AREA, THE RECEPTACLE SHALL BE GFCI [CEC
<br />210.8(4)].
<br />15. BASEMENTS, GARAGES AND ACCESSORY BUILDINGS. FOR A ONEFAMILY
<br />DWELLING, AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED IN THE AREAS
<br />SPECIFIED IN 210.52(G)(1) THROUGH (3)/ THESE RECEPTACLES SHALL BE IN ADDITION TO
<br />RECEPTACLES REQUIRED FOR SPECIFIC EQUIPMENT. [CEC210.521
<br />(1) GARAGES, IN EACH ATTACHED GARAGE AND IN EACH DETACHED GARAGE WITH
<br />ELECTRICAL POWER. THE BRANCH CIRCUIT SUPPLYING THIS RECEPTACLE(S) SHALL NOT
<br />SUPPLY OUTLETS OUTSIDE OF THE GARAGE, AT LEAST ONE RECEPTACLE OUTLET SHALL BE
<br />INSTALLED FOR EACH CAR SPACE.
<br />(2)ACCESSORY BUILDINGS. IN EACH ACCESSORY BUILDING WITH ELECTRIC POWER.
<br />(3) BASEMENT. IN EACH SEPARATE UNFINISHED PORTION OF A BASEMENT .
<br />D. LIGHTING [CEC 210.70]
<br />1. SWITCHED LIGHTING SHALL BE INSTALLED IN:
<br />- ALL HABITABLE ROOMS, BATHROOMS, HALLWAYS, AND STAIRWAYS AT EACH LEVEL ,
<br />- GARAGES,
<br />- AT ALL OUTDOOR ENTRANCES AND EXITS,
<br />- IN ALL ATTICS, UNDER FLOOR AREAS, UTILITY ROOMS AND BASEMENTS USED FOR
<br />STORAGE
<br />- NEAR HVAC EQUIPMENT IN ATTIC, UNDER FLOOR AREAS, ROOMS OR BASEMENTS. WITH A
<br />SWITCH AT THE ACCESS POINT.
<br />2. LIGHTING INSTALLED IN A CLOSET SHALL BE A SURFACE MOUNTED OR RECESSED
<br />FLUORESCENT FIXTURE OR A SURFACE MOUNTED INCANDESCENT FIXTURE WITH
<br />COMPLETELY ENCLOSED LAMPS OR RECESSED INCANDESCENT FIXTURE WITH COMPLETELY
<br />ENCLOSED LAMPS.
<br />SURFACE INCANDESCENT LIGHTING SHALL BE INSTALLED A MINIMUM OF 12 IN. FROM THE
<br />NEAREST POINT OF A STORAGE SPACE. SURFACE FLUORESCENT LIGHTING AND RECESSED
<br />LIGHTING SHALL BE INSTALLED A MINIMUM OF 6 IN. FROM THE NEAREST POINT OF A
<br />STORAGE SPACE. [CEC 410.16(C)]
<br />E. FANS
<br />EACH BATHROOM CONTAINING A BATHTUB, SHOWER, OR BATHTUB/SHOWER COMBINATION
<br />SHALL BE MECHANICALLY VENTILATED FOR PURPOSES OF. HUMIDITY CONTROL IN
<br />ACCORDANCE WITH THE CALIFORNIA MECHANICAL CODE AND THE CALIFORNIA GREEN
<br />BUILDING STANDARDS CODE.
<br />F. SMOKE ALARMS
<br />IN NEW CONSTRUCTION, SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM
<br />THE BUILDING WIRING. THE WIRING SHALL BE PERMANENT AND INSTALLED WITHOUT A
<br />DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT PROTECTION
<br />[CRC R314.4, CBC 907.2.10,5].
<br />CLOTHES DRYER NOTES:
<br />1. A MINIMUM OF 4" MOISTURE EXHAUST DUCT MUST BE PROVIDED [MC 504.4.2]
<br />2. DRYER EXHAUST CANNOT EXCEED 14 FT WITH A MAX OF TWO 90 DEGREE ELBOWS LCMC
<br />504.4.2.1]
<br />3. A FLEXIBLE DUCT CANNOT EXTEND MORE THAN 6 FT. AND CANNOT BE CONCEALED [CMC
<br />504.4.2.2]
<br />PLUMBING NOTE:
<br />PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(c), ALL NON- COMPLIANT PLUMBING FIXTURES
<br />SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES.
<br />NOTE:
<br />1. INTERIOR STAIRWAYS SHALL BE PROVIDED WITH ARTIFICIAL LIGHT SOURCE LOCATED IN THE
<br />IMMEDIATE VICINITY OF EACH LANDING OF THE STAIRWAY, CAPABLE OF ILLUMINATING TREADS AND
<br />LANDINGS AT LEAST 1-FOOT CANDLE MEASURED AT THE CENTER OF TREADS AND, LANDINGS. (CRC
<br />R303.7, CBC 1204.4).
<br />BATHROOM NOTES:
<br />1. THE WATER CLOSET SHALL HAVE A CLEARANCE OF 30 INCHES WIDE (15 INCHES ON CENTER) AND 24
<br />INCHES IN FRONT. (CPC 402.5) WHERE THE WATER CLOSET (OR OTHER PLUMBING FIXTURE COMES
<br />INTO CONTACT WITH THE WALL OR FLOOR, THE JOINT SHALL BE CAULKED AND SEALED TO BE
<br />WATERTIGHT. (CPC 402.2)
<br />2. SHOWER STALLS SHALL BE A MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES, BE CAPABLE
<br />OF ENCOMPASSING A 30 INCH DIAMETER CIRCLE. ANY DOORS SHALL SWING OUT OF THE ENCLOSURE
<br />HAVE A CLEAR OPENING OF 22 INCHES MINIMUM. (CPC 408.5, 408.6)
<br />PLUMBING NOTE:
<br />PER SECTION 301.1.1 CALGREEN AND CIVIL CODE 1101.3(c), ALL NON- COMPLIANT PLUMBING FIXTURES
<br />SHALL BE REPLACED WITH WATER-CONSERVING PLUMBING FIXTURES.
<br />NOTES:
<br />9. Water Heating system (water heater) ˆ¢â‹â (Section 150.0(n))
<br />a. Systems using gas or propane water heaters to serve individual dwelling units shall designate a space at least 2.5 feet by 2.5 feet wide and 7 feet tall
<br />suitable for the future installation of a heat pump water heater (HPWH) by meeting either A or B listed under Section 150.0(n).
<br />A. If the designated space is within 3 feet from the water heater:
<br />i. A dedicated 125 volt, 20 amp electrical receptacle that is connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG copper branch circuit,
<br />within 3 feet from the water heater.
<br />Heat pump space heater (furnace) ready: System using gas furnace to serve individual dwelling units shall include a dedicated 240 volt, minimum 30 amps
<br />branch circuit wiring shall be installed within 3-ft from the furnace for a future heat pump space heater installation
<br />Electric cooktop ready: System using gas to serve individual dwelling units shall include the following shall include a dedicated 240 volt, minimum 50 amps
<br />circuit wiring shall be installed within 3-ft from the cooktop for a future electric cooktop installation.
<br />- 1/4" = 1'-0"
<br />1 PROPOSED ELECTRICAL PLAN
<br />SCALE:
<br />NO
<br />R
<br />T
<br />H
|