Laserfiche WebLink
GSPublisherVersion 0.0.100.100 <br />4 <br />7 <br />1 <br />5 <br />& <br />4 <br />7 <br />1 <br />7 <br /> <br />W <br />. <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />, <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />N <br />E <br />W <br /> <br />A <br />D <br />D <br />I <br />T <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />N <br />E <br />W <br /> <br />A <br />D <br />U <br />sheet title: <br />sheet number: <br />REVISIONS <br />NO.DATE DESCRIPTION <br />DESIGN <br />DRAWN <br />ISSUED <br />APPROVED <br />NS <br />JT <br />A2.5 <br />PROPOSED SECTION; <br />WINDOW AND DOOR <br />SCHEDULE <br />N&NC <br />12 <br />4 <br />5 <br /> <br />EA <br />S <br />T <br /> <br />WA <br />L <br />N <br />U <br />T <br /> <br />ST <br />R <br />E <br />E <br />T <br />, <br />ST <br />E <br /> <br />11 <br />2 <br />PA <br />S <br />A <br />D <br />E <br />N <br />A <br />, <br />CA <br /> <br /> <br />91 <br />1 <br />0 <br />6 <br />1' <br />8' <br />4' <br />- <br />1 <br />" <br />12 <br />' <br />- <br />1 <br />1 <br />" <br />(N) NEW "A" CLASS ROOF <br />TO MATCH EXISTING <br />(N) NEW "A" CLASS ROOF <br />TO MATCH EXISTING <br />FIRST FLOOR HEIGHT <br />EL.=+1'-0" <br />RIDGE HEIGHT <br />EL.=+13'-1" <br />CEILING HEIGHT <br />EL.=+9'-0" <br />12 4124 <br />124 12 4 <br />(N) ADU BATHROOM <br />(N) <br />ATTIC <br />(N) ADU LIVING (N) ADU KITCHEN <br />(N)2"X4" DOUBLE <br />TOP PLATE <br />(N)STUCCO <br />(N)R15 INSULATION <br />(N)GYPSUM BOARD <br />(N)2"X4" DOUBLE <br />TOP PLATE <br />(N)STUCCO <br />(N)R15 INSULATION <br />(N)GYPSUM BOARD <br />(N)R38 INSULATION <br />(N)RAISED FOUNDATION <br />W/ R-19 INSULATION <br />(N) FOUNDATION(N) FOUNDATION <br />(N)R38 INSULATION <br />(N)RAISED FOUNDATION <br />W/ R-19 INSULATION <br />(N)RAISED FOUNDATION <br />W/ R-19 INSULATION <br />WINDOW SCHEDULE <br />MARK TO ROOM :NAME WIDTH HEIGHT HEAD HEIGHT FAMILY SWING <br />W1 (N) ADU BEDROOM 2'-6"4'-0"8'-0"Window -Single-Hung <br />W2 <br />SHGC <br />0,23 <br />U-FACTOR <br />0,3UP <br />NOTES <br />0,23 0,38'-0" <br />W3 0,23 0,34'-0"3'-4"8'-0"Window -Double-Sliding LEFT <br />W4 (N) ADU BATHROOM 0,23 0,31'-6"8'-0"Window -LEFT <br />W5 0,23 0,33'-0"8'-0"Window -Double-Sliding LEFT <br />(N) ADU BEDROOM 2'-6"4'-0"8'-0"Window -Single-Hung UP <br />(N) ADU BEDROOM <br />4'-0"Double-Sliding <br />(N) ADU KITCHEN 3'-0" <br />W 1 W 2 W 3 <br />W 4 <br />W 5 <br />D 1 D 2 D 3 D 5 D 6D4 <br />6'-8" <br />6' <br />6'-8" <br />3' <br />3'-8" <br />3' <br />3'4' <br />5'-2" <br />1'-6" <br />4' <br />3'-4" <br />3'-4" <br />2'-6" <br />2'-8" <br />4' <br />2'-6" <br />2'-8" <br />4' <br />2'-11 <br />" <br />1'-9" <br />10'4'-6"3' <br />6'-8" <br />6'-8" <br />6'-8" <br />3' <br />6'-8" <br />DOOR SCHEDULE <br />MARK FUNCTION WIDTH HEIGHT FAMILY SWING <br />D1 EXTERIOR 3'-0"6'-8"DOOR-EXTERIOR-HINGED RIGHT <br />TO ROOM: NAME <br />(N) ADU LIVING <br />NOTES <br />D2 EXTERIOR 6'-0"DOOR-EXTERIOR-SLIDER LEFT(N) ADU KITCHEN <br /> 1/4" = 1'-0" <br />1 1-1 SECTION <br />SCALE:- <br />GENERAL NOTES: <br />ANY ADDITION OR CHANGES MADE TO THE APPROVED EXTERIOR ELEVATION DESIGN <br />EITHER ON THE DRAWINGS OR DURING CONSTRUCTION WILL REQUIRE PLANNING <br />DIVISION AND BUILDING DIVISION REVIEW AND APPROVAL AND MAY RESULT IN A <br />DELAY OF THE PROJECT OR THE REMOVAL OF NON-APPROVED WORK. <br />GLAZING NOTES: <br />GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY GLAZING CONFORMING TO THE <br />HUMAN IMPACT LOADS OF SECTION R308.5 (SEE EXCEPTIONS) (R308.4) <br />A. FIXED AND OPERABLE PANELS OF SWINGING , SLIDING AND BI-FOLD DOOR ASSEMBLIES. <br />B. GLAZING IN AN INDIVIDUAL FIXED OPERABLE PANEL ADUACENT TO A DOOR WHERE THE <br />NEAREST VERTICAL EDGE IS WITHIN 24-INCH ARC OF EITHER VERTICAL EDGE OF THE <br />FLOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE <br />FLOOR OF WALING SURFACE. <br />C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE <br />FOLLOWING CONDITIONS: <br />ili. EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. <br />iiv. BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />v. TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />vi. ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING <br />D. GLAZING IN GUARDS AND RAILINGS. <br />E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, <br />STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EDGE <br />AS THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING <br />FOR WALKING SURFACE. <br />F. GLAZING IN WALLS AND FENCES ADJACENT TO INDOOR AND OUTDOOR SWIMMING <br />POOLS, HOT TUBS AND SPAS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 <br />INCHES ABOVE A WALKING SURFACE AND WITHIN SO INCHES, MEASURED HORIZONTALLY <br />AND IN STRAIGHT LINE OF THE WATER'S EDGE. <br />G. GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 <br />INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, <br />LANDINGS BETWEEN FLIGHTS OF STAIRS AND RAMPS <br />H. GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE <br />GLAZING IS LESS THAN 36 INCHES ABOVE THE LANDING AND WITHIN <br />60 INCH HORIZONTAL ARC LESS THAN 180 DEGREES FROM THE BOTTOM TREAD NOSING <br />(R304.2). <br />I. SKYLIGHTS AND SLOPED GLAZING SHALL COMPLY WITH SECTION R308.6 <br />NOTES: <br />THE NERC TEMPORARY LABEL DISPLAYED ON WINDOWS AND SKYLIGHTS (INCL. TUBULAR) <br />MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED <br />1. ALL GLAZING TO BE LOW-E DUAL GLAZED GLASS - EXTERIOR FLOOR TO CEILING <br />WINDOWS AND DOORS TO BE TEMPERED <br />2. WINDOWS LOCATED IN SHOWERS SHALL BE TEMPERED AND SPECIFIED FOR USE IN <br />SHOWER (WET RATED). CONTRACTOR TO INSTALL SHOWER WATERPROOFING MEMBRANE <br />OVER WINDOW JAMB AND CAULK COMPLETELY AROUND WINDOW/TILE JOINT <br />3. ALL NEW METAL FINISH TO MATCH EXISTING <br />4. ALL NEW WINDOWS TO MATCH WINDOW CONFIGURATION AND GLAZING COLOR <br />5. EXTERIOR WINDOWS AND DOORS SHALL HAVE A U-FACTOR OF 0.23 AND AN SHGC OF 0.3 <br />6. DOOR AND WINDOW OPENINGS ON EAST AND WEST EXTERIOR WALLS MUST BE WITH 3/4- <br />HOUR FIRE ASSEMBLIES. <br />2640SH 2640SH 4034LS 4016LS 3030LS 3068 6068 <br />TEMPERED <br />TEMPERED <br />D3 INTERIOR 3'-0"DOOR-INTERIOR-HINGED RIGHT(N) ADU BATHROOM <br />D4 INTERIOR 3'-0"DOOR-INTERIOR-HINGED LEFT(N) ADU BEDROOM <br />D5 INTERIOR 4'-6"DOOR-INTERIOR-HINGED <br />RIGHT <br />(N) ADU LAUNDRY <br />D6 INTERIOR 10'-0"DOOR-INTERIOR-SLIDER(N) ADU CLOSET <br />6'-8" <br />6'-8" <br />6'-8" <br />6'-8" <br />6'-8" <br />3068 4668 100683068 <br />TEMPERED