Laserfiche WebLink
HARDWARE GENERAL NOTES <br />1. ALL EXTERIOR DOORS REQUIRE THRESHOLDS AND <br />WEATHERSTRIPPING (INCLUDING SILLS). <br />2. ALL SWINGING DOORS (HOLLOW METAL, STAINLESS STEEL) <br />SHALL HAVE KICKPLATES. <br />3. ALL SWINGING DOORS (HOLLOW METAL, STAINLESS STEEL) <br />SHALL HAVE CLOSERS EXCEPT FOR JANITOR’S DOORS AND <br />DOUBLE DOORS. <br />4. PROVIDE DOOR STOPS ON ALL DOORS OPENING AGAINST <br />WALLS. <br />5. PROVIDE PANIC HARDWARE ON THE DOORS AS NOTED. <br />FLUSH PANEL <br />H. <br />I <br />. <br />C <br />. <br />W.I.C. <br />POWER <br />OPERATOR <br />BOTTOM OF DOOR TO BE <br />1'-0" ABOVE HEAD IN FULL <br />OPEN POSITION <br />DOOR PULL <br />PULL DOWN <br />ROPE <br />(2) 25" X 12" DOUBLE <br />GLAZED, SEALED <br />GLASS UNITS <br />H. <br />I <br />. <br />C <br />. <br /> <br />- <br /> <br />S <br />E <br />E <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />1' <br /> <br />- <br /> <br />0 <br />" <br />VE <br />R <br />I <br />F <br />Y <br />6' <br /> <br />- <br /> <br />0 <br />" <br />HASP AND <br />STAPLE LOCK <br />SECTIONAL DOOR (2 LITES) <br />TRACK OPTIONS: <br />-HIGH-LIFT <br />T1 <br />"HIGH LIFT" <br />TRACK PROFILE <br />FACE OF WALL <br />OR JAMB <br />COLUMN <br />2"W.I.C.2" <br />H. <br />I <br />. <br />C <br />. <br />2" <br />TYPE F1 <br />ARMOR PLEATS <br />SIDE PAD <br />GUIDE STRIPES <br />TRUCK RESTRAINT <br />OUTSIDE LIGHT BOX <br />REVERSE LETTER <br />CAUTION SIGN <br />CAUTION SIGN <br />124 125 <br />FINISH FLOOR ELEV. <br />0'-0" <br />+/ <br />- <br /> <br />5 <br />' <br /> <br />- <br /> <br />3 <br />" <br /> <br />V <br />E <br />R <br />I <br />F <br />Y <br />CAUTION <br />BACK IN OR <br />PULL OUT <br />ON GREEN <br />LIGHT ONLY <br />TRUCK DRIVERS WARNING SIGN <br />5/8" DIA. THREADED <br />SS ROD; 3 PER EACH <br />JAMB AND HEAD <br />INSULATED WALL <br />PANEL <br />DOCK <br />SEAL PAD <br />3" x 3" x 14 GA. <br />GALV. WASHER <br />CONT. SEALANT <br />EACH SIDE <br />26 GA. GALV. STEEL DUST <br />HOOD W/ FINISH TO <br />MATCH PANELS <br />FOAM-IN-PLACE <br />INSULATION <br />STEEL GIRT <br />10 GA. GALV. STEEL CLADDING, <br />RETURN & TACK WELD TO <br />GIRT. ATTACH TO PANEL W/ # <br />10 x 1" COUNTER-SUNK GALV. <br />SCREWS @ 1'-0" O.C. <br />ROUT OUT PANEL AND <br />INSTALL 4x PLASTIC LUMBER <br />BLOCKING. ATTACH TO <br />PANEL SKIN W/ 1-1/2" LONG <br />GALV. STEEL NAILS @ 6" O.C. <br />10 GA. GALV. STEEL ANCHOR <br />STRAP -LAG W/ GALV. <br />COUNTER-SUNK LAG SCREWS <br />3 PER EACH JAMB & HEAD <br />2" RIGID INSULATION <br />COMPLETELY FILL <br />JOINT WITH SEALANT <br />/E B-401-1 <br />SEALANT <br />METAL CLAD DOOR & <br />FRAME BY DOOR MANUF. <br />STL. COLUMN -SEE <br />STRUCTURAL DRAWINGS <br />3" x 3" x 14 GA. GALV. <br />STEEL WASHER <br />PVC WEATHERSTRIPPING <br />RETURN 1" & TACK <br />WELD TO TUBE <br />FOAM-IN-PLACE INSULATION <br />10 GA. GALV. STEEL CLADDING <br />ROUT OUT PANEL AND INSTALL 4x <br />PLASTIC LUMBER BLOCKING. <br />ATTACH TO PANEL SKIN W/ 1-1/2" <br />LONG GALV. STEEL NAILS @ 6" O.C. <br />COUNTERSUNK GALV. SCREWS <br />1" LONG @ 1'-0" O.C. (TYPICAL) <br />GALV. STEEL ANCHOR STRAP -LAG <br />W/ GALV. COUNTER-SUNK LAG <br />SCREWS 3 PER EACH JAMB & HEAD <br />DOCK SEAL PAD <br />5/8" DIA. THREADED <br />S.S. THRU-BOLT, 3 PER <br />EACH JAMB AND HEAD <br />INSULATED <br />WALL PANEL <br />INSULATED METAL PANEL - <br />SEE PLANS FOR THICKNESS <br />DOOR AS SCHEDULED SEALANT (TYP.) <br />FRAME AS SCHEDULED, <br />THERMALLY BROKEN AT <br />EXTERIOR CONDITIONS <br />2" <br />5 3/4" <br />1/2" DIA. STAINLESS STEEL RODS @ <br />12" O.C., COUNTERSUNK <br />26 GA. GALV. STEEL TRIM W/ <br />FINISH TO MATCH PANELS <br />2x6 PLASTIC LUMBER BLOCKING <br />ROUT OUT PANEL AND INSTALL 4x <br />PLASTIC LUMBER BLOCKING. <br />ATTACH TO PANEL SKIN W/ 1-1/2" <br />LONG GALV. STEEL NAILS @ 6" O.C. <br />AT EXTERIOR HEAD <br />CONDITIONS -26 GA. GALV. <br />STEEL HOOD 4'-6" WIDE; COLOR <br />TO MATCH PANELS. FASTEN <br />THRU BUTYL TAPE W/ FAB-LOK <br />FASTENERS W/ PAINTED HEADS <br />@ 6" O.C.; HOOD MUST EXTEND <br />BEYOND DOOR AND FRAME <br />RUBBER CLOSURE STRIP <br />SEALANT AT EXTERIOR HEAD <br />CONDITIONS - COMPLETELY <br />FILL JOINT WITH SEALANT <br />FOAM INSULATION <br />/E B-401-1 <br />FINISH FLOOR <br />B-600-1 <br />H <br />G <br />B-600-1 <br />E <br />B-600-1 <br />SEE DOOR SCHEDULE <br />SE <br />E <br /> <br />D <br />O <br />O <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />F <br />B-600-1 <br />7 7/8" <br />DOOR SIDE <br />12" <br />INSULATED METAL WALL PANEL <br />10GA GALV. BENT PLATE <br />CONT. SEALANT, BOTH <br />SIDES (TYP.) <br />T <br />= <br /> <br />4 <br />" <br />T <br />+ <br /> <br />1 <br />/ <br />8 <br />" <br /> <br />( <br />C <br />L <br />R <br />. <br />) <br />4 <br />1 <br />/ <br />8 <br />" <br /> <br />1/2" DIA ASTM A307 GALVANIZED <br />THRU BOLT AT 24" O.C. <br />RAPID ROLL <br />DOOR TRACK <br />7 7/8" <br />DOOR SIDE <br />12" <br />INSULATED METAL WALL <br />PANEL <br />10GA GALV. BENT <br />PLATE <br />CONT. SEALANT, BOTH <br />SIDES (TYP.) <br />T <br />= <br /> <br />4 <br />" <br />T <br />+ <br /> <br />1 <br />/ <br />8 <br />" <br /> <br />( <br />C <br />L <br />R <br />. <br />) <br />4 <br />1 <br />/ <br />8 <br />" <br /> <br />1 1/2"4" <br />1" <br />2" <br />GALV. CLIP ANGLE 3" X 3" X 1/4" <br />X 4" LONG W/(1) 5/8" DIA. ASTM <br />F1554-36 GALV. ANCHOR ROD <br />W/ 4" EMBED. USING HILTI HIT <br />HY200V3 ADHESIVE <br />1/8" <br />TYP. - 3 SIDES <br />1/2" DIA ASTM A307 GALVANIZED <br />THRU BOLT AT 24" O.C. <br />RAPID ROLL DOOR TRACK <br />12 <br />" <br /> <br />12" FOR ERECTION <br />1/4" GAP INSULATED METAL WALL PANEL <br />10GA GALV. BENT <br />PLATE HEADER <br />FILL GAP W/ URETHANE <br />SEALANT <br />GALV. CLIP ANGLE 4" X 4" X <br />1/4" X 5 1/2" LONG W/(2) 5/8" <br />DIA. GALV. NUTS @ 3" <br />SPACING, SHOP WELDED <br />TO THE TOP FOR THE <br />HEADER ATTACHMENT. <br />1/8" <br />TYP. <br />CUT WEB OF BENT PLATE <br />JAMB AT UPPER <br />INSULATED METAL PANEL <br />GALV. THRU BOLTS FOR <br />DOOR ATTACHMENT - <br />COORD. W/ DOOR <br />MANUFACTURER <br />(2) 5/8" DIA. GALV. ASTM <br />A307 BOLTS. THREAD <br />INTO SHOP WELDED <br />NUTS ABOVE. <br />10GA GALV. BENT <br />PLATE JAMB <br />NOTES: <br />1. THIS DETAIL IS LOOKING AT <br />THE DOOR SIDE OF THE FRAME <br />1 1/2" <br />7 <br />7 <br />/ <br />8 <br />" <br />DO <br />O <br />R <br /> <br />S <br />I <br />D <br />E <br />12 <br />" <br /> <br />INSULATED METAL WALL PANEL <br />10GA GALV. BENT <br />PLATE <br />CONT. SEALANT, BOTH <br />SIDES (TYP.) <br />T = 4" <br />T + 1/8" (CLR.) <br />4 1/8" <br />1/2" DIA ASTM A307 <br />GALVANIZED THRU <br />BOLT AT 24" O.C. <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />B-600-1 <br />RBF <br />EJE <br />04/02/2024 <br />DOOR SCHEDULE, <br />ROOM SCHEDULE <br />AND DOOR DETAILS <br />2350 PULLMAN ASPIRE BAKERY <br />2350 PULLMAN STREET <br />SANTA ANA, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />PULLMAN,LLC <br />DOOR SCHEDULE <br />Door No. <br />Door Size <br />Type Door Material <br />Frame/Track <br />Type Frame Material <br />Details Hardware <br />Door <br />Operation <br />Armored <br />Floor Joint Fire Rating CommentsWidth Height Thickness Head Jamb Guard Set Security <br />Heater <br />Cable <br />101.1 3' - 0" 7' - 0" 1 3/4" Flush Panel Insul. Hollow Metal F1 Insul. Hollow Metal MATCH EXIST MATCH EXIST REUSE FRAME OR PROVIDE NEW AS REQ. <br />131.1 3' - 0" 7' - 0" 1 3/4" Flush Panel Insul. Hollow Metal F1 Insul. Hollow Metal A/B-600-1 A/B-600-1 <br />131.2 7' - 0" 10' - 0" Cased Opening - Galvanized Steel D/B-600-1 D/B-600-1 <br />131.3 9' - 0" 10' - 0" 2" Sectional High-Lift (2 Lites) Galvanized Steel T1 Galvanized Steel B/B-600-1 C/B-600-1 Electric <br />ROOM FINISH SCHEDULE <br />ROOM <br />NO.ROOM NAME AREA FLOOR FINISH <br />BASE <br />FINISH <br />WALLS CEILING <br />FINISH <br />FIRE RATED <br />ENCLOSURE COMMENTSNORTH EAST SOUTH WEST <br />101 EXISTING ELECTRICAL ROOM 189 SF ETR ETR ETR ETR ETR ETR ETR PATCH AND REPAIR ALL FINISHES ADJACENT TO DEMO/NEW CONSTRUCTION AS REQ TO MATCH EXIST <br />104 EXISTING PACKAGING Not Enclosed ETR ETR ETR/IMP ETR ETR ETR ETR PATCH AND REPAIR ALL FINISHES ADJACENT TO DEMO/NEW CONSTRUCTION AS REQ TO MATCH EXIST <br />131 DOCK ADDITION 1714 SF SC CONC. CURB IMP IMP TXT/IMP IMP EXP PATCH AND REPAIR ALL FINISHES ADJACENT TO DEMO/NEW CONSTRUCTION AS REQ TO MATCH EXIST <br />ROOM FINISHES - BASE LEGEND <br />ID PRODUCT <br />CONC. CURB CONCRETE CURB - SEE WALL SECTIONS FOR SIZES <br />STL. ANGLE STEEL ANGLE <br />ROOM FINISHES - FLOORING LEGEND <br />ID PRODUCT <br />SC SEALED CONCRETE <br />MBG METAL BAR GRATING <br />ROOM FINISHES - WALL FINISH LEGEND <br />ID PRODUCT <br />INSULATED METAL PANEL <br />IMP INSULATED METAL PANEL <br />MISCELLANEOUS <br />ETR EXISTING TO REMAIN <br />TXT EXISTING CONC. PANEL COATING SYSTEM - SEE PAINT SPECS <br />ROOM FINISHES - GENERAL FLOORING NOTES <br />1 SUBMIT ALL SAMPLES TO INTERIOR DESIGNER OR ARCHITECT FOR REVIEW & APPROVAL. <br />2 FLOORING TRANSITIONS: TRANSITION TO OCCUR DIRECTLY UNDERNEATH DOOR (TRANSITION NOT VISIBLE IN EITHER <br />ROOM). <br />3 ALL HARD SURFACE FLOORING AND GROUT TO BE CLEANED & SEALED ACCORDING TO MANUFACTURER'S RECOMMENDED <br />PROCEDURES. <br />4 ALL NEW FLOOR DRAIN COVER PLATES TO BE SQUARE. <br />5 WHERE CONCRETE WALL MATERIAL OCCUR, NO FLOOR BASE TO BE INSTALLED. <br />ROOM FINISHES - GENERAL PAINTING AND DECORATING NOTES <br />1 SUBMIT ALL SAMPLES TO INTERIOR DESIGNER OR ARCHITECT FOR REVIEW & APPROVAL. <br />2 ALL WALL VENTS TO BE PAINTED SPECIFIED WALL COLOR OR PAINT TO MATCH WALL COVERING. <br />DOOR TYPES TRACK PROFILESDOOR FRAME TYPES <br />1/4" = 1'-0"B-600-1 <br />1 DOCK DOOR LIGHTS/SIGNAGE <br />1 1/2" = 1'-0"B-600-1 <br />B DOOR HEAD - DOCK DOOR IN IMP W/ SEAL <br />1 1/2" = 1'-0"B-600-1 <br />C DOOR JAMB - DOCK DOOR IN IMP WITH SEAL <br />1 1/2" = 1'-0"B-600-1 <br />A DOOR HEAD/JAMB - PERSONNEL IN IMP <br />1/4" = 1'-0"B-600-1 <br />D <br />INTERIOR OVERHEAD DOOR & <br />OPENING IN IMP ELEVATION <br />1 1/2" = 1'-0"B-600-1 <br />E <br />FRAMING DETAIL - JAMB W/ 10GA <br />WRAP <br />1 1/2" = 1'-0"B-600-1 <br />F <br />FRAMING DETAIL - JAMB TO FLOOR <br />W/ 10GA. WRAP <br />1 1/2" = 1'-0"B-600-1 <br />H <br />FRAMING DETAIL - HEADER TO JAMB <br />W/ 10GA. WRAP <br />1 1/2" = 1'-0"B-600-1 <br />G <br />FRAMING DETAIL - HEAD W/ 10GA. <br />WRAP <br />NO. DATE DESCRIPTION <br />A 04/02/2024 ISSUED FOR PERMIT AND <br />CONSTRUCTION <br />REGISTERED PROFESSIONAL ENGINEER67268RICHARD MAURICE THIBEAULT <br />STATE OF CALIFORNIACIVIL <br />4/2/24 <br />2350 S Pullman St - <br />Phase I3/4/2025