Laserfiche WebLink
<br />Current Date: 4/1/2024 3:48 PM <br />Units system: English <br />Design Results <br />Reinforced Concrete Footings <br />______________________________________________________________________________________________________________________________ <br />GENERAL INFORMATION: <br />Global status :OK <br />Design Code :ACI 318-2014 <br />Footing type :Spread <br />Column type :Steel <br />Geometry <br />Length :5.00 [ft] <br />Width :5.00 [ft] <br />Thickness :2.00 [ft] <br />Base depth :3.00 [ft] <br />Base area :25.00 [ft2] <br />Footing volume :50.00 [ft3] <br />Base plate length :12.00 [in] <br />Base plate width :12.00 [in] <br />Column length :12.00 [in] <br />Column width :4.00 [in] <br />Column location relative to footing g.c.:Centered <br />Materials <br />Concrete, f'c :5.00 [Kip/in2]Steel, fy :60.00 [Kip/in2] <br />Concrete type :Normal Epoxy coated :No <br />Concrete elasticity modulus :4030.51 [Kip/in2]Steel elasticity modulus :29000.00 [Kip/in2] <br />Unit weight :0.15 [Kip/ft3] <br />Soil <br />Modulus of subgrade reaction :200.00 [Kip/ft3] <br />Unit weight (wet):0.11 [Kip/ft3] <br />Page1 <br />5387 JAMB COLUMN FOOTING ON COLUMN LINE N3 <br />15.150 <br />2350 S Pullman St - <br />Phase I3/4/2025