Laserfiche WebLink
UP <br />UP <br />UP <br /><250 FT. <br />LIFE SAFETY LEGEND: <br />EXIT DATA <br />TRAVEL <br />DISTANCE <br />Egress Width <br />Allowable Occupants <br />Actual Occupants <br />Comment <br />ADA Accessibility <br />FE <br />LOCATION <br />ACCESSIBLE EXIT <br />NUMBER <br />1 <br />SIGN DESCRIPTION <br />TACTILE SIGN WITH INTERNATIONAL SYMBOL OF <br />ACCESSIBILITY AND TEXT WORDING: "EXIT". <br />NON-ACCESSIBLE EXIT 2 TACTILE SIGN WITH INTERNATIONAL SYMBOL OF <br />ACCESSIBILITY, ARROW POINTING IN REVERSE <br />DIRECTION AND TEXT WORDING: "FOLLOW TO AN <br />ACCESSIBLE EXIT". <br />TACTILE SIGNAGE AT DOORS FOR ACCESSIBILITY <br />(INCLUDING MECHANICAL AND ELECTRICAL) <br />SIGNAGE NOTES: <br />1. ALL SIGNS INDICATED SHALL BE AS REQUIRED FOR ACCESSIBILITY PER THE 2022 <br />CALIFORNIA BUILDING CODE CHAPTER 11B, SECTION 11B-703.5, AND THE <br />SPECIFICATION. <br />2. ALL SIGNS FOR ACCESSIBILITY COMPLIANCE SHALL BE TACTILE SIGNS WITH <br />BRAILLE. REFER TO DETAILS FOR PLACEMENT. ALL FONTS AND SIZES SHALL MEET <br />THE REQUIREMENTS OF CHAPTER 11B, SECTION 11B-703.7.2.1 AND THE <br />SPECIFICATIONS. ALL SIGNS FOR ACCESSIBILITY SHALL INCLUDE THE <br />INTERNATIONAL SIGN FOR ACCESSIBILITY. <br />FIRE EXTINGUISHER LOCATIONS - <br />PORTABLE FIRE EXTINGUISHERS ARE REQUIRED PER SECTION <br />906. PER THE STATE FIRE CODE, FIRE EXTINGUISHERS WILL BE <br />PROVIDED FOR MODERATE HAZARD AS INDICATED:MINIMUM <br />PROVIDED CLASS 4A IN OFFICE AREA; 10A IN WAREHOUSE AREA. <br />1500 SF MAXIMUM AREA PER UNIT OF A 11,250 SF MAX PER FIRE <br />EXTINGUISHER. 75 FEET MAXIMUM TRAVEL DISTANCE TO <br />EXTINGUISHER. <br />FIRE EXTINGUISHERS ARE TO BE MOUNTED TO STEEL COLUMNS <br />AND WALLS ONLY. <br />MOUNT ON EITHER SIDE FACE OF COLUMN TO PROTECT IT FROM <br />FORKLIFT ACTIVITY. PROVIDE PROTECTION WHERE FIRE <br />EXTINGUISHERS ARE REQUIRED TO BE MOUNTED TO COLUMN <br />OR WALL FACE CLOSEST TO AISLE. <br />NOTE: ALL FIRE EXTINGUISHER LOCATIONS ARE SHOWN FOR <br />INTENT AND CODE COMPLIANCE -FINAL LOCATIONS ARE TO BE <br />COORDINATED WITH THE OWNER'S FINAL RACKING LAYOUT. <br />FIRE EXTINGUISHER <br />BRACKET MOUNTED <br />FIRE <br />E <br />X <br />T <br />I <br />N <br />G <br />U <br />I <br />S <br />H <br />E <br />R <br />1' <br /> <br />- <br /> <br />6 <br />" <br />4" <br />CO <br />N <br />T <br />R <br />A <br />C <br />T <br />O <br />R <br /> <br />T <br />O <br /> <br />V <br />E <br />R <br />I <br />F <br />Y <br />15 <br />' <br />- <br />0 <br />" <br /> <br />A <br />. <br />F <br />. <br />F <br />. <br />VINYL CUTOUT STICK- <br />ON SIGN <br />PROVIDE SIGN @ FIRE <br />EXTINGUISHER COLUMN <br />LOCATIONS <br />FIRE EXTINGUISHER SIGNAGE <br />CLEAR FLOOR AREA <br />CENTERED ON TACTILE <br />CHARACTERS <br />LOCATION OF TACTILE SIGNS AT DOORS <br />45° <br />45 <br />5 <br /> <br />M <br />M <br />18 <br />" <br /> <br />M <br />I <br />N <br />455 MM <br />18" MIN <br />FIG. 703.3.11 <br />SIGN <br />TEXT <br />SIGN <br />TEXT <br />15 <br />2 <br />5 <br /> <br />M <br />M <br />60 <br />" <br /> <br />M <br />A <br />X <br />12 <br />2 <br />0 <br /> <br />M <br />M <br />48 <br />" <br /> <br />M <br />A <br />X <br />HEIGHT OF TACTILE CHARACTERS ABOVE FLOOR OR GROUND <br />FIG. 703.3.10 <br />ROOM OCCUPANCY <br />MECHANICAL <br />STORAGE (S-1) <br />34" <br />226 <br />1 <br />NOT ACCESSIBLE <br />34" <br />226 <br />12 <br />ACCESSIBLE <br />18 <br />EXISTING EGRESS DOOR <br />TO BE MAINTAINED <br />EXISTING EGRESS DOOR <br />TO BE MAINTAINED <br />EXISTING EGRESS DOOR <br />TO BE MAINTAINED <br />EXISTING EGRESS DOOR <br />TO BE MAINTAINED <br />EXISTING EGRESS DOOR <br />TO BE MAINTAINED <br />TRAVEL DISTANCE <250' <br />PHASE -1 ADDITION PHASE -2 FUTURE ADDITION <br />1 <br />2 <br />FIRE EXTINGUISHER <br />TRAVEL DISTANCE <250' <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />G-003-1 <br />RBF <br />EJE <br />04/02/2024 <br />LIFE SAFETY PLAN <br />2350 PULLMAN ASPIRE BAKERY <br />2350 PULLMAN STREET <br />SANTA ANA, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />PULLMAN,LLC <br />Occupancy Schedule Phase 1 <br />Number Name Area <br />Area per <br />Occupant <br />Number of <br />Occupants <br />MECHANICAL <br />101 EXISTING ELECTRICAL ROOM 189 SF 300 SF 0.63 <br />189 SF 0.63 <br />STORAGE (S-1) <br />131 DOCK ADDITION 1,714 SF 500 SF 3.43 <br />1,714 SF 3.43 <br />1,903 SF 4.06 <br />3/32" = 1'-0"G-003-1 <br />1 LIFE SAFETY OVERALL FLOOR PLAN <br />NO. DATE DESCRIPTION <br />A 04/02/2024 ISSUED FOR PERMIT AND <br />CONSTRUCTION <br />REGISTERED PROFESSIONAL ENGINEER67268RICHARD MAURICE THIBEAULT <br />STATE OF CALIFORNIACIVIL <br />4/2/24 <br />2350 S Pullman St - <br />Phase I3/4/2025