Laserfiche WebLink
CL <br />CL <br />A A <br />2 1/2" ID CONDUIT <br />HYDRAULIC LINES <br />(BY CONTRACTOR) <br />3/4" ID CONDUIT <br />LOW VOLTAGE SWITCHES <br />(BY CONTRACTOR) <br />VB420-11FF-SF <br />BUMPERS w/ RISERS <br />AND BACK PLATES <br />(BY VENDOR) <br />3/4" CONDUIT FOR <br />INCOMING POWER <br />(BY CONTRACTOR) <br />EQUIPMENT EXCLUSION <br />AREA (SEE NOTE 5) <br />3/4" CONDUIT <br />APS-2000 <br />(BY CONTRACTOR) <br />(2) 3/4" CONDUITS FOR <br />DOOR POWER & CONTROLS <br />(BY CONTRACTOR) <br />MIN. 4" OF SLACK <br />IN ELECTRICAL LINE <br />1/2" ID CONDUIT TO <br />OUTSIDE LIGHTS <br />(BY CONTRACTOR) <br />24V COMPACT LED LIGHTS & SIGN <br />(SUPPLIED BY VENDOR) <br />(INSTALLED BY VENDOR) <br />3/4" CONDUIT FOR <br />LOADING LIGHT <br />(BY CONTRACTOR) <br />JUNCTION BOX (BY CONTRACTOR) <br />3 1/2" DEEP MAXIMUM <br />WATER TIGHT <br />3/4" DIA X 6" <br />WEDGE ANCHOR <br />MOVE ON <br />GREENONLY <br />709-832 R3 <br />MOVE ON <br />ONLYGREEN <br />CAUTION <br />6" <br />SECTION D-D(SCALED 2X) <br />TYPICAL CONTROL INSTALLATION <br />(ALL CONDUIT AND INTERCONNECTION <br />BY OTHERS) <br />DOOR DOOR <br />3/4" CONDUIT FOR <br />INCOMING POWER <br />(BY CONTRACTOR) <br />HYDRAULIC POWER <br />UNIT AND SOLENOIDS <br />(SUPPLIED BY KELLEY) <br />(INSTALLED BY CONTRACTOR) <br />3/4" CONDUIT FOR <br />INCOMING POWER <br />(BY CONTRACTOR) <br />3/4" CONDUIT FOR <br />HYDRAULIC POWER UNIT <br />(BY CONTRACTOR) <br />2 1/2" ID CONDUIT <br />HYDRAULIC LINES <br />(BY CONTRACTOR) <br />3/4" ID CONDUIT <br />LOW VOLTAGE SWITCHES <br />(BY CONTRACTOR) <br />2 1/2" ID CONDUIT <br />HYDRAULIC LINES <br />(BY CONTRACTOR) <br />3/4" ID CONDUIT <br />LOW VOLTAGE SWITCHES <br />(BY CONTRACTOR) <br />BOLT-ON STANCHION <br />(SUPPLIED BY VENDOR) <br />(INSTALLED BY CONTRACTOR) <br />CONTROL PANEL <br />(SUPPLIED BY KELLEY) <br />(INSTALLED BY CONTRACTOR) <br />3/4" CONDUIT FOR <br />APS-2000 <br />(BY CONTRACTOR) <br />3/4" CONDUIT FOR <br />DOOR CONTROLS <br />(BY CONTRACTOR) <br />3/4" CONDUIT FOR <br />APS-2000 <br />(BY CONTRACTOR) <br />3/4" CONDUIT FOR <br />DOOR POWER <br />(BY CONTRACTOR) <br />(2) 3/4" CONDUITS FOR <br />DOOR POWER & CONTROLS <br />(BY CONTRACTOR) <br />3/4" ID CONDUIT <br />LOW VOLTAGE SWITCHES <br />(BY CONTRACTOR) <br />3/4" ID CONDUIT <br />LOADING LIGHT <br />(BY CONTRACTOR) <br />3/4" CONDUIT FOR <br />LOADING LIGHT <br />(BY CONTRACTOR) <br />1/2" CONDUIT FOR <br />OUTSIDE LIGHT <br />(BY CONTRACTOR) <br />1/2" CONDUIT FOR <br />OUTSIDE LIGHT <br />(BY CONTRACTOR) <br />NOTES: <br />1. ELECTRICAL CONTRACTOR MUST ENSURE THAT ALL ELECTRICAL <br />CONDUIT AND WIRING MEETS LOCAL ELECTRICAL CODES. <br />2. ALL CONDUIT SIZES ARE MINIMUM. <br />3. ALL CONDUIT SHOWN FOR REFERENCE ONLY. <br />4. GENERAL CONTRACTOR SHALL ENSURE EQUIPMENT <br />INSTALLATION MEETS ALL APPLICABLE BUILDING CODES. <br />5. DO NOT PLACE BOLLARDS OR AOTHER EQUIPMENT IN <br />EQUIPMENT EXLUSION AREA OF VSL'S. <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />E-401-1 <br />ARL <br />SEL <br />04/02/2024 <br />ELECTRICAL <br />DETAILS <br />2350 Pullman WSS OCTA Aspire <br />Bakeries <br />2350 Pullman Street <br />Santa Ana, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />Pullman,LLC <br />NO.DATE DESCRIPTION <br />A 04/02/2024 ISSUED FOR PERMIT AND <br />CONSTRUCTION <br />NO SCALEE-401-1 <br />A DOCK LEVELER DETAIL <br />REGISTERED PROFESSIONAL ENGINEER24467 <br />STEPHEN E LASLO <br />STATE OF CALIFORNIA <br />4/2/24 <br />2350 S Pullman St - <br />Phase I3/4/2025