My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2350 S Pullman St-Phase I-DEF 1-Concrete Foundation Underpinning - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Pullman St
>
2350 S Pullman St
>
2350 S Pullman St-Phase I-DEF 1-Concrete Foundation Underpinning - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:02:31 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20184030
30147790
40139535
101120904
101120905
101120906
Full Address
2350 S Pullman St
Street Number
2350
Street Direction
S
Street Name
Pullman
Street Suffix
St
Jump to thumbnail
< previous set
next set >
Text box
ID:
1
Creator:
Import Agent
Created:
2/24/2026 5:02 AM
Modified:
2/12/2026 9:25 AM
Text:
09-
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1630
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1 2 <br />D <br />E <br />F <br />G <br />H <br />J <br />N3 <br />N1 <br />N4 <br />N5N6 <br />N2 <br />NBNCNDNENF <br />EXISTING <br />CONDENSING UNIT TO <br />BE REMOVED AND <br />DISCARDED <br />DEMO PICTURE 3 <br />DEMO PICTURE 2 <br />DEMO PICTURE 1 <br />RECLAIM ALL REFRIGERANT AND <br />OIL PRIOR TO ANY DEMOLITION <br />COMMENCING. REMOVE ALL <br />CONTROL WIRING AND CONDUIT <br />THAT ARE EXTERNAL TO THE <br />BUILDING. FIELD VERIFY. <br />DEMOLISH AND REMOVE EXISTING R-404 <br />LIQUID AND SUCTION HEADERS IN THE <br />BUILDING. ALL NEW R448 PIPING WILL GO <br />UP THROUGH THE CEILING AND ROOF TO <br />NEW REFRIGERANT MAINS LOCATED ON <br />THE ROOF. FIELD VERIFY <br />DOCK ADDITION <br />131 <br />EXISTING <br />ELECTRICAL <br />ROOM <br />101 <br />EXISTING <br />COOLER <br />102 <br />EXISTING <br />FREEZER <br />103 <br />1. VISIT AND INSPECT THE JOB SITE PRIOR TO BIDDING AND BECOME FAMILIAR <br /> WITH ALL EXISTING CONDITIONS. INCLUDE THE COST OF THE WORK REQUIRED <br /> TO ACCOMMODATE THE EXISTING CONDITIONS IN THE BID PROPOSAL. <br />2. REMOVE WITH CARE ALL EQUIPMENT TO BE RELOCATED. REPAIR OR REPLACE <br /> DAMAGED EQUIPMENT AS REQUIRED. <br />3. COORDINATE DISPOSITION OF ALL REMOVED EQUIPMENT WITH THE OWNER. <br />4. TERMS: <br /> ABANDONED: REFERS TO REFRIGERATION EQUIPMENT AND SYSTEMS WHICH <br /> ARE NO LONGER IN USE AND ARE TO BE DE-ENERGIZED AND <br /> LEFT IN PLACE. <br /> REMOVAL: REFERS TO REFRIGERATION EQUIPMENT AND SYSTEMS WHICH ARE <br /> NOT TO BE REUSED AND ARE TO BE REMOVED FROM THE JOB <br /> SITE AND DISPOSED OF AS DIRECTED BY THE OWNER. <br />5. REMOVE EXISTING REFRIGERATION PIPING AND EQUIPMENT AS INDICATED BY <br /> AND CAP REFRIGERATION PIPING TO REMAIN. <br />6. PROVIDE TEMPORARY PROVISIONS FOR ALL EXISTING AND / OR NEW REFRIG <br /> PIPING AND REFRIGERATION SYSTEMS TO MAINTAIN SERVICE IN ADJACENT <br /> AREAS. TEMPORARY PROVISIONS INCLUDE BUT ARE NOT LIMITED TO PIPING, <br /> VALVES AND MISCELLANEOUS MATERIALS AS REQUIRED TO SUPPORT EXISTING <br /> REFRIGERATION SYSTEMS. <br />7. PROVIDE MATERIALS TO MATCH EXISTING CONSTRUCTION UNLESS SPECIFIED <br /> ELSEWHERE IN THESE CONTRACT DOCUMENTS. PROVIDE MATERIALS THAT <br /> COMPLY WITH CODE AND THEIR INTENDED FUNCTION. <br />8. PROVIDE ALL MATERIALS, RENTALS AND EQUIPMENT NECESSARY FOR THE <br /> REQUIRED DEMOLITION, REMOVAL AND RELOCATION OF EXISTING EQUIPMENT. <br />9. COORDINATE ALL REFRIGERATION SYSTEM SHUT DOWNS WITH THE OWNER. <br />10. PROVIDE TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN <br /> SERVICE DURING CONSTRUCTION. WHEN PERFORMING WORK ON ENERGIZED <br /> EQUIPMENT USE PERSONNEL EXPERIENCED IN SUCH OPERATIONS. <br />11. CONNECT EQUIPMENT THAT IS EXISTING AND THAT IS TO REMAIN TO THE NEW <br /> SYSTEM AS REQUIRED TO MAINTAIN ITS PROPER OPERATION. <br />12. PATCH WALL OPENINGS FROM DEMOLISHED REFRIGERATION PIPING AND <br /> REMOVED REFRIGERATION CONTROL WIRING CONDUITS TO MATCH EXISTING <br /> PLANT WALL FINISH. <br />13. THE REFRIGERATION CONTRACTOR SHALL REPAIR ALL EXISTING INSULATION <br /> THAT IS DAMAGED OR ALTERED DURING CONSTRUCTION. <br />14. DEMOLITION DRAWINGS ARE INTENDED TO INDICATE THE GENERAL SCOPE AND <br /> INTENT OF THE DEMOLITION WORK REQUIRED AND SHOULD NOT LIMIT, IN ANY <br /> WAY, THE FULL SCOPE OF THE DEMOLITION WORK. DEMOLITION WORK INCLUDES <br /> REMOVAL OF ALL EXISTING REFRIGERATION CONDENSING SYSTEM REFRIGERANT, <br /> EQUIPMENT, VALVES, PIPING, CONTROL, CONTROL WIRING, CONDUITS, HANGERS <br /> AND LOOSE FURNISHING NOT PREVIOUSLY REMOVED BY THE OWNER THAT IS <br /> REQUIRED TO ACCOMPLISH THE INTENT OF THE CONSTRUCTION DOCUMENTS. <br />15. THE OWNER SHALL HAVE THE OPTION OF KEEPING ANY OR ALL SALVAGEABLE ITEMS <br /> REMOVED FROM THE BUILDING. <br />16. CONTRACTORS ARE RESPONSIBLE FOR REVIEWING THE COMPLETE SET OF <br /> CONSTRUCTION DOCUMENTS INCLUDING THE SPECIFICATIONS AND TO CHECK AND <br /> VERIFY EXISTING CONDITIONS TO DETERMINE AND UNDERSTAND THE FULL SCOPE <br /> OF THE DEMOLITION WORK. NO ADDITIONAL COMPENSATION WILL BE CONSIDERED <br /> FOR WORK THAT COULD BE REASONABLY INFERRED FROM REVIEW OF THE <br /> CONSTRUCTION DOCUMENTS AND THE EXISTING FIELD CONDITIONS. <br />17. THE REFRIGERATION CONTRACTOR IS RESPONSIBLE FOR ALL WALL AND ROOF <br /> PENETRATIONS AND ANY REPAIRS REQUIRED FROM THE REMOVAL OF EXISTING PIPING <br /> THAT IS TO BE REMOVED. PATCH EXISTING WITH SIMILAR CONSTRUCTION TO MATCH <br /> EXISTING CONDITIONS. <br /> <br />REFRIGERATION DEMOLITION GENERAL NOTES : <br />DRAWN BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />CHECKED BY: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET ISSUE DATE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <br />SHEET NUMBER <br />THE INFORMATION CONTAINED ON THIS AND ANY <br />RELATED DOCUMENT SHALL NOT BE USED FOR <br />ANY PURPOSE OTHER THAN THE CONVEYANCE <br />OF INFORMATION FOR THE STATED CLIENT AND <br />PROJECT WITHOUT THE EXPRESS WRITTEN <br />CONSENT OF THE ENGINEER. <br />ANY INFORMATION TRANSFERRED OR UTILIZED <br />IN AUTOCAD .DWG FORMAT SHALL BE USED FOR <br />REFERENCE ONLY <br />WEBBER/SMITH Associates, Inc. <br />20 Wright Avenue <br />Lititz, Pennsylvania 17543 <br />Phone: 717.625.4140 <br />Email:info@webbersmith.com <br />SHEET TITLE: <br />FOR <br />DRAWING STATUS <br />FINAL <br />PROJECT NUMBER <br />www.webbersmith.com <br />SEAL <br />RD100-1 <br />PJS <br />JSD <br />04/02/2024 <br />FLOOR PLAN - <br />DEMOLITION <br />2350 Pullman WSS OCTA Aspire <br />Bakeries <br />2350 Pullman Street <br />Santa Ana, CA 92705 <br />CA <br />5387 <br />© 2024 WEBBER/SMITH Associates, Inc., All Rights Reserved <br />2350 <br />Pullman,LLC <br />1/8" = 1'-0"RD100-1 <br />1 FLOOR PLAN - DEMOLITION <br />EXISTING PIPE TO BE REMOVED <br />BACK TO FACE OF EXISTING <br />BUILDING WALL AND COVERED <br />WITH NEW GRATED OPENING <br />EXISTING PIPE TO BE REMOVED <br />BACK TO FACE OF EXISTING <br />BUILDING WALL AND COVERED <br />WITH NEW GRATED OPENING <br />DEMO PICTURE 1 <br />DEMO PICTURE 2 <br />DEMO PICTURE 3 <br />CAP EXISTING PIPES AT WALL. <br />1 2 <br />EXISTING FACILITY <br />KEY PLAN REFERENCE <br />NORTH <br />TRUE <br />NORTH <br />NO. DATE DESCRIPTION <br />A 04/02/2024 ISSUED FOR PERMIT AND <br />CONSTRUCTION <br />REGISTERED PROFESSIONAL ENGINEER33478 <br />JAMES S DEPEW <br />STATE OF CALIFORNIAMECHANICAL <br />4/2/24 <br />2350 S Pullman St - <br />Phase I3/4/2025
The URL can be used to link to this page
Your browser does not support the video tag.