Laserfiche WebLink
SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />DATE ISSUED: <br />PROJECT NO: <br />10/23/2023 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br />A <br />S <br />T <br /> <br />C <br />E <br />N <br />T <br />R <br />A <br />L <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />DESCRIPTION DATE <br />2022-40198 <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />As Noted <br />SHEET <br />NUMBER: <br />Valve Number <br />Valve Size <br /># <br /># <br /># <br />IRRIGATION MISCELLANEOUS EQUIPMENT <br />IRRIGATION UTILITIES <br />IRRIGATION CONTROLLER <br />IRRIGATION PIPING <br />PIPE SIZE <br />DRIPLINE TUBING or 1/2" PVC0 - 5 GPM <br />ZONE FLOW <br />8.1 - 13 GPM <br />1 1/2" PVC <br />5 - 8 GPM 3/4" PVC <br />1 1/4" PVC13.1 - 22 GPM <br />22.1 - 30 GPM <br />1" PVC <br />VALVE KEY:DRIPLINE SUPPLY/EXHAUST LATERAL PIPE SIZING: <br />SUB-SURFACE IRRIGATION <br />TL050MFV-1 FLUSH VALVE. INSTALL VALVE INSIDE 6" ROUND VALVE BOX, ONE AT THE FAR <br />END/LOW SIDE OF EACH PLANTER DRIP LINE LATERAL. INSTALL MINIMUM OF ONE FLUSH VALVE <br />PER MAXIMUM OF 800' OF TUBING. MULTIPLE FLUSH VALVES MAY BE REQUIRED WITHIN DRIP LINE <br />LAYOUT. ALWAYS INSTALL VALVES IN OPPOSITE DIRECTIONS OF THE PVC/DRIP CONNECTION <br />MANIFOLD. REFER TO MANUFACTURER SPECIFICATIONS AND INSTALLATION GUIDELINES. <br />NETAFIM <br />65AR1B1-B AIR/VACUUM RELIEF VALVE - INSTALL AIR RELIEF ASSEMBLY INSIDE A 6" ROUND VALVE <br />BOX AT THE HIGH POINT OF EACH PLANTER, MIN. 1 PER 500' OF DISTRIBUTION TUBING. USING AIR <br />RELIEF LATERAL, CONNECT AIR RELIEF VALVE TO ALL DRIP LINE LATERALS WITHIN THE <br />ELEVATED AREA. REFER TO MANUFACTURER SPECIFICATIONS AND INSTALLATION GUIDELINES. <br />MULTIPLE ARV'S MAY BE REQUIRED PER RCV WITHIN UNDULATING AREAS, VERIFY QUANTITY <br />PRIOR TO STARTING WORK, FLUSH VALVES and AIR RELIEF VALVES SHOWN DIAGRAMMATICALLY, <br />INSTALL VALVE BOX 18" FROM PAVING AND AT HIGH POINTS OF PLANTER AREA. <br />NETAFIM <br />RAINBIRD ECO-INDICATOR INSTALLED ON EVERY STATION.NO SYMBOL <br />NO SYMBOL <br />NO SYMBOL <br />EXISTING MAINLINE, PROTECT-IN-PLACE <br />NON-PRESSURE LATERAL SCH. 40 PVC PIPE. FOR SIZES 3/4" - 2" W/ PVC SCH. 40 FITTINGS - BURY <br />MIN. 12" BELOW GRADE, SEE DETAIL FOR SLEEVING AND DEPTHS. SEE PLAN FOR SLEEVING <br />LOCATIONS. SEE PLAN FOR PIPE SIZES. <br />AS APPROVED <br />PVC PIPE SCH. 40 SLEEVING, TWICE THE DIAMETER OF PIPE OR WIRE BUNDLE CARRIED - EXTEND <br />18" BEYOND EDGE OF PAVING & PLACE BELOW ALL PAVING, HARDSCAPE, ETC., AND AS DIRECTED <br />BY OWNER'S AUTHORIZED REPRESENTATIVE. <br />S S <br />S S <br />AS APPROVED <br />AS APPROVED <br />NOTE: <br />PRESSURE RELIEF VALVES SHALL BE INSTALLED AT ALL IRRIGATION MAINLINE PIPING <br />"DEAD-ENDS" AND "RIGHT ANGEL" TURNS TO PREVENT WATER HAMMER DAMAGE TO PIPE AND <br />FITTINGS. USE THRUST BLOCKS TO PREVENT WATER HAMMER WHERE NECESSARY. <br />Valve Flow <br />(GPM) <br />RAINBIRD <br />DRIPLINE TREE RING - XFS-CV DRIPLINE TUBING .6 GPH EMITTERS AT 12" ON CENTER SPACING. TUBING <br />SHALL BE INSTALLED ON GRADE W/ 9" WIRE STAKES FOUR (4) FEET ON CENTER; VERIFY THE <br />LAYOUT AND CENTER SPACING IN THE FIELD PRIOR TO STARTING WORK. INSTALL ON GRADE DRIP <br />IRRIGATION SYSTEM PER MANUFACTURER'S SPECIFICATIONS. SEE DETAIL. ON SEPERATE VALVE <br />THAN SHRUB DRIPLINE. ENSURE ALL PIECES OF DRIP TUBING HAVE EMITTERS IN THEM AND NO <br />BLANK SECTIONS ARE USED IN THE ASSEMBLY OF DRIP RING. <br />POC DOMESTIC SERVICE LINE by OTHERS. <br />NEW GATE VALVE, T-113NIBCO <br />DRIP LINE LAYOUT NOTE: NOT ALL SUPPLY/EXHAUST LATERALS SHOWN ON PLAN for GRAPHIC <br />CLARITY - INSTALL LATERALS per MANUFACTURER'S SPECIFICATIONS and RECOMMENDATIONS TO <br />AVOID LOW PRESSURE THROUGH DRIPPERLINE and CONNECTIONS.* <br />USE RAINBIRD FITTINGS FOR CONNECTION BETWEEN PVC LATERAL LINES AND INLINE DRIP <br />TUBING. <br />XFD-06-18 DRIPLINE TUBING 0.6 GPH EMITTERS AT 12" ON CENTER SPACING - ALL TUBING <br />SHALL BE INSTALLED ON GRADE W/ 9" W/TUBING STAKES FOUR (4) FEET ON CENTER; VERIFY <br />THE LAYOUT AND CENTER SPACING IN THE FIELD PRIOR TO STARTING WORK. INSTALL ON <br />GRADE DRIP IRRIGATION SYSTEM per MANUFACTURER'S SPECIFICATIONS. <br />RAINBIRD <br />PAIGENO SYMBOL <br />DS1000 DIRECT BURIAL WATER-PROOF WIRE CONNECTORS FOR USE ON ALL WIRE <br />CONNECTIONS <br />IRRIGATION 'CONTROL' WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED) <br />NO SYMBOL SPEARS <br />PAIGENO SYMBOL IRRIGATION 'COMMON' WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED) <br />PAIGENO SYMBOL IRRIGATION 'SPARE' WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED) <br />EXISTING RE-USE AND REWIRE EXISTING CONTROLLER, FIELD VERIFY ACTUAL LOCATION <br />EXISTING MAINLINE TO BE RELOCATED. FIELD VERIFY CUT AND CAP REQUIRMENTS.EXISTING <br />AS APPROVED NEW MAINLINE AND CONTROL WIRES - FIELD VERIFY LOCATION, SIZE, AND DEPTH OF TIE-INS TO <br />EXISTING MAINLINE. SIZE TO MATCH EXISTING. LOCATED IN PLANTING AREAS. <br />BURY MIN. 24" BELOW GRADE . <br />RAINBIRD RAIN BIRD XCZ-100-PRB-COM , WIDE FLOW DRIP CONTROL KIT FOR COMMERCIAL APPLICATIONS. <br />1IN. BALL VALVE WITH 1IN. PESB VALVE AND 1IN. PRESSURE REGULATING 40PSI QUICK-CHECK <br />BASKET FILTER. 0.3 GPM-20 GPM <br />EXISTING EXISTING REMOTE CONTROL VALVE, PROTECT-IN-PLACE <br />RAINBIRD NEW QUICK COUPLER, 5-LRC-1" (26 <br />34) LOCKING RUBBER COVER, 1-PIECE BODY <br />RAINBIRD RAIN BIRD RWS-B-C W/ RWS-SOCK 1400 SERIES <br />ROOT WATERING SYSTEM WITH 4IN. DIAMETER X 36IN. LONG WITH LOCKING GRATE, SEMI-RIGID MESH TUBE. CHECK <br />VALVE AND SAND SOCK. RAIN BIRD BUBBLER OPTION AS INDICATED: 1401 0.25 GPM, 1402 0.5 GPM, 1404 1.0 GPM, 1408 2 <br />GPM. <br />NO SYMBOL <br />L5.001 <br />LANDSCAPE <br />IRRIGATION <br />NOTES AND <br />LEGENDS <br />EXTRA WIRE NOTE <br />GENERAL IRRIGATION NOTES <br />1.THE IRRIGATION SYSTEM DESIGN IS BASED ON A MINIMUM OPERATING PRESSURE OF 70 PSI AT THE POC. <br />CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION. IF A DIFFERENT PRESSURE IS FOUND, <br />REPORT IMMEDIATELY TO OWNER. <br />2.PIPE SIZES SHALL CONFORM TO THOSE SHOWN ON THE DRAWING, NO SUBSITTUTIONS OF SMALLER PIPE SIZES <br />SHALL BE PERMITTED, BUT SUBSTITUTIONS OF LARGER SIZES MAY BE APPROVED. ALL DAMAGED AND REJECTED <br />PIPE SHALL BE BE REMOVED FROM THE SITE AT THE TIME OF REJECTION. <br />3.ALL SPRINKLER HEADS SHALL BE SET PERPENDICULAR TO FINISH GRADE UNLESS OTHERWISE SPECIFIED. <br />4.THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS AND VALVES FOR OPTIMUM <br />COVERAGE WITH MINIMAL OVERSPRAY ONTO WALKS, STREETS, WALLS, AND ETC. <br />5.THE IRRIGATION DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR <br />CLARIFICATION ONLY AND SHALL BE INSTALLED WITHIN PLANTING AREAS WHEREVER POSSIBLE. <br />6.IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO BECOME FAMILIAR WITH ALL GRADE <br />DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, STRUCTURES, AND UTILITIES. THE IRRIGATION <br />CONTRACTOR SHALL REPAIR OR REPLACE ALL ITEMS DAMAGED BY THEIR WORK. WORK SHALL BE COORDINATED <br />WITH OTHER CONTRACTORS FOR THE LOCATION AND INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER <br />ROADWAYS, PAVING, AND ETC. <br />7.DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE <br />FIELD THAT UNKNOWN OBSTRUCTIONS, GRADE DIFFERENCES, OR DIFFERENCES ON SITE EXIST THAT ARE NOT <br />SHOWN ON THE PLANS. SUCH OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF <br />THE OWNER'S AUTHORIZED REPRESENTATIVE. IN THE EVENT THAT NOTIFICATION IS NOT PERFORMED, THE <br />IRRIGATION CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY. <br />8.ALL SPRINKLER EQUIPMENT NOT DETAILED OR SPECIFIED SHALL BE INSTALLED AS PER MANUFACTURER'S <br />RECOMMENDATIONS AND SPECIFICATIONS. <br />9.THE IRRIGATION CONTRACTOR SHALL INSTALL ANTI-DRAIN VALVES ON ALL HEADS IN AREAS WHERE FINISH GRADE <br />EXCEEDS 4:1, WHERE POST VALVE SHUT OFF DRAINING OF THE IRRIGATION SYSTEM OCCURS, OR AS DIRECTED <br />BY THE OWNER'S AUTHORIZED REPRESENTATIVE. <br />TWO (2) EXTRA PILOT WIRES, YELLOW IN COLOR, <br />SHALL BE PROVIDED AND TERMINATED IN THE <br />FURTHEST BOX IN THE CONTROLLER. ALL EXTRA <br />WIRES SHALL BE LOOPED IN THE VALVE BOX WITH 24" <br />MINIMUM. BUNDLE ALL EXTRA WIRES IN CONTROLLER. <br />SLEEVING NOTES <br />1.IRRIGATION PIPE AND LOW VOLTAGE CONTROL VALVE WIRE SHALL BE SLEEVED <br />UNDER PAVING. <br />2.SLEEVES TO BE AT MINIMUM TWICE THE DIAMETER OF THE PIPE SLEEVED. <br />3.PRESSURE MAINLINE SLEEVES SHALL BE ACCOMPANIED WITH A MINIMUM 1" WIRE <br />SLEEVE. <br />4.SLEEVES TO EXTEND A MINIMUM 12" BEYOND PAVING. <br />5.PROTECT ALL SLEEVE ENDS TO PROHIBIT SOIL FROM ENTERING THE SLEEVE. <br />6.IRRIGATION CONTRACTOR TO COORDINATE SLEEVING WITH THE HARDSCAPE <br />CONTRACTOR PRIOR TO INSTALLATION OF ANY HARDSCAPE. <br />7.REFER TO LEGEND FOR SLEEVE SPECIFICATION. <br />WATER AUDIT NOTE: <br />THE CONTRACTOR WILL CONDUCT AN IRRIGATION AUDIT USING A CERTIFIED IRRIGATION AUDITOR, AFTER THE FINAL <br />FIELD OBSERVATION HAS BEEN COMPLETED AND ALL IRRIGATION COMPONENTS ARE <br />INSTALLED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND THE IRRIGATION SYSTEM IS ACCEPTED BY <br />THE PROJECT LANDSCAPE ARCHITECT FOR MAINTENANCE. <br />THE IRRIGATION AUDIT WILL BE CONDUCTED IN ACCORDANCE WITH THE FOLLOWING SCHEDULE: <br />1. PLACE FLAGS AT EACH HEAD IN THE ZONE. <br />2. MEASURE SPACING AND MARK MID-POINTS BETWEEN HEADS. <br />3. PLACE WATER MEASURING RECEPTACLES. <br />4. TAKE READINGS OF WATER LEVEL IN RECEPTACLES AND RECORD RESULTS. <br />5. MEASURE HEAD PRESSURE IN EACH ZONE AND RECORD RESULTS. <br />6. AFTER COMPLETING ZONE ADVANCE TO NEXT ZONE AND REPEAT PROCEDURE. <br />7. SUBMIT THE RESULTS OF THE AUDIT TO THE PROJECT ARCHITECT. <br />THE IRRIGATION MAINTENANCE SCHEDULE TASKS LISTED BELOW ARE INTENDED AS MINIMUM STANDARDS AND MORE <br />FREQUENT ATTENTION MAY BE REQUIRED DEPENDING ON THE PARTICULAR SITE CONDITIONS. <br />MAINTENANCE TASK <br />1. CONTROLLER CABINET - OPEN CABINET, CLEAN OUT DEBRIS, <br />AND REPLACE BATTERY AS NECESSARY. CHECK WIRING AND <br />REPAIR AS NEEDED. CHECK CLOCK AND RESET, IF NECESSARY. <br />2. IRRIGATION SCHEDULE - ADJUST SCHEDULE FOR SEASONAL <br />VARIATIONS AND OTHER CONDITIONS WHICH MAY AFFECT THE <br />AMOUNT OF WATER NEEDED TO MAINTAIN PLANT HEALTH. <br />ADJUST AS NECESSARY. <br />3. POC - VISUALLY INSPECT COMPONENTS FOR LEAKS, PRESSURE <br />SETTINGS, SETTLEMENT OR OTHER DAMAGE AFFECTING THE <br />OPERATION OF A COMPONENT REPAIR AS NEEDED. <br />4. REMOTE CONTROL VALVES, ISOLATION VALVES AND QUICK <br />COUPLER VALVES - VISUALLY INSPECT FOR LEAKS, SETTLEMENT, <br />WIRE CONNECTIONS AND PRESSURE SETTINGS. REPAIR OR <br />ADJUST AS NEEDED. <br />5. MAINLINE AND LATERALS - VISUALLY INSPECT FOR LEAKS OR <br />SETTLEMENT OF TRENCH. <br />6. SPRINKLERS - VISUALLY CHECK FOR ANY BROKEN, MISSALIGNED <br />OR CLOGGED HEADS, HEADS WITH INCORRECT ARC, INADEQUATE <br />COVERAGE OR OVERSPRAY AND LOW HEAD DRAINAGE. REPAIR AS <br />NEEDED. <br />7. FILTERS AND STRAINERS - VISUALLY CHECK FOR LEAKS AND BROKEN <br />FITTINGS. CLEAN AND FLUSH SCREENS. <br />AUDIT SHALL BE IN ACCORDANCE WITH THE LATEST STATE OF CALIFORNIA LANDSCAPE WATER MANAGEMENT <br />PROGRAM AS DESCRIBED IN THE LATEST LANDSCAPE IRRIGATION AUDITOR HANDBOOK. THE LANDSCAPE IRRIGATION <br />AUDITS TO BE CONDUCTED BY A QUALIFIED INDIVIDUAL AND THE AUDIT SCHEDULE SHALL BE CONDUCTED AT LEAST <br />ONCE EVERY FIVE YEARS IN ACCORDANCE WITH THE REQUIREMENTS OF TITLE 20, DIVISION 1. <br />FREQUENCY <br />QUARTLEY <br />MONTHLY <br />QUARTERLY <br />QUARTERLY <br />QUARTERLY <br />WEEKLY <br />MONTHLY <br />IRRIGATION AUDIT SCHEDULES: <br />1.AT A MINIMUM, AUDITS SHALL BE IN ACCORDANCE WITH THE LATEST STATE OF CALIFORNIA <br />LANDSCAPE WATER MANAGEMENT PROGRAM AS DESCRIBED IN THE LANDSCAPE IRRIGATION <br />AUDITOR HANDBOOK, PREPARED FOR THE CALIFORNIA DEPARTMENT OF WATER <br />RESOURCES, WATER CONSERVATION OFFICE, THE ENTIRE DOCUMENT, WHICH IS HEREBY <br />INCORPORATED BY REFERENCE. <br />3. THE SCHEDULE SHALL PROVIDE FOR LANDSCAPE IRRIGATION AUDITS TO BE CONDUCTED BY <br />A QUALIFIED INDIVIDUAL AS DETERMINED BY THE DIRECTOR AT LEAST ONCE EVERY FIVE <br />YEARS IN ACCORDANCE WITH THE REQUIREMENTS OF TITLE 20, DIVISION 1. <br />IRRIGATION MAINTENANCE SCHEDULES: <br />1.MAINTENANCE SCHEDULES. A REGULAR MAINTENANCE SCHEDULE SATISFYING THE <br />FOLLOWING CONDITIONS SHALL BE SUBMITTED AS PART OF THE LANDSCAPE <br />DOCUMENTATION PACKAGE. <br />2.LANDSCAPE SHALL BE MAINTAINED TO ENSURE WATER EFFICIENCY. A REGULAR <br />MAINTENANCE SCHEDULE SHALL INCLUDE, BUT NOT BE LIMITED TO, CHECKING, ADJUSTING, <br />AND REPAIRING IRRIGATION EQUIPMENT, RESETTING THE AUTOMATIC CONTROLLER, <br />AERATING AND DETHATCHING TURF AREAS, REPLENISHING MULCH, FERTILIZING, PRUNING, <br />AND WEEDING IN ALL LANDSCAPE AREAS. <br />3.WHENEVER POSSIBLE, REPAIR OF IRRIGATION EQUIPMENT SHALL BE DONE WITH THE <br />ORIGINALLY SPECIFIED MATERIALS OR THEIR EQUIVALENTS. <br />4.A LANDSCAPE IRRIGATION AUDIT SCHEDULE AS REQUIRED IN CHAPTER 20.09 OF TITLE 20 <br />MAY BE RECOMMENDED. THE MAXIMUM PERIOD BETWEEN AUDITS SHALL BE FIVE YEARS. <br />505 E Central Ave <br />#B11/6/2024