My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
RAINBIRD REMOTE CONTROL VALVE <br />WITH FILTER REGULATOR <br />IRRIGATION VALVE BOX: HEAT <br />STAMP LID WITH 'RCV' IN 2" LETTERS <br />WATERPROOF CONNECTORS (2) <br />18"-24" COILED WIRE TO <br />CONTROLLER <br />FINISH GRADE AT ADJACENT <br />SURFACE (TURF OR MULCH) <br />SCH. 80 CLOSE NIPPLE, MATCH SIZE <br />TO VALVE <br />PVC SLIP X FPT UNION <br />ISOLATION VALVE, SIZE AND TYPE <br />PER PLAN <br />BRICK SUPPORTS (4) <br />FILTER FABRIC - WRAP TWICE <br />AROUND BRICK SUPPORTS <br />3/4" WASHED GRAVEL - 4" MIN. DEPTH <br />IRRIGATION LATERAL <br />MAINLINE LATERAL AND FITTINGS <br />LEGEND <br />MIN. 1" <br /> CLR. <br />PLAN VIEW <br />SECTION VIEW <br />6 <br />13 <br />1 <br />13 <br />12 <br />11 <br />10 <br />9 <br />8 <br />7 <br />6 <br />5 <br />4 <br />3 <br />2 <br />1 <br />SCALE: 1 1 <br />2"= 1'=0" <br />13 <br />10 <br />5 <br />12 <br />7 <br />6 <br />4 3 <br />7 <br />8 <br />6 <br />7 <br />8 <br />6 <br />7 <br />12 <br />13 <br />2 <br />9 <br />2" <br />1" MIN <br />6" <br />MIN <br />4 <br />1 <br />2 <br />3 <br />5 <br />76 <br />9 <br />8 <br />1 <br />3 <br />4 <br />5 <br />7 <br />LEGEND <br />FINISH GRADE <br />BREAK-OFF GROVES 3 <br />PLACES - 4" TYP. <br />VALVE BOX. SEE <br />SPECIFICATIONS. <br />GATE VALVE W/ HANDWHEEL <br />LINE SIZE <br />PRESSURE MAINLINE SUPPLY <br />LINE PER SPECS. <br />2 COMPACTED SUBGRADE <br />6 SCH 80 P.V.C. NIPPLES, TYP. <br />8 3 <br />4" CRUSHED ROCK 8" DEPTH <br />9 COMMON RED BRICK, ONE AT <br />EACH CORNER (4 REQUIRED) <br />NOTE : <br />FOR 2 1 <br />2" LARGER GATE VALVE, USE <br />CAST IRON FLANGE ADAPTOR <br />BETWEEN G.V & P.V.C. SUPPLY. <br />PAVEMENT1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />NOTES: <br />1.LOCATE VALVE BOXES IN PLANTING AREAS. <br />2.WRAP VALVE BOX WITH A MINIMUM OF 3 MIL THICK <br />PLASTIC AND SECURE IT USING DUCT TAPE OR <br />ELECTRICAL TAPE. <br />3.ALL THREADED CONNECTION TO BE MADE USING <br />TEFLON TAPE. <br />4.ALL CHANGES IN ELEVATION SHALL BE MADE USING <br />SCH. 40 PVC 45° ELBOWS. <br />1 <br />VALVE BOX W/ LOCKING LID <br />2 <br />3 <br />THREADED BALL VALVE (SEE IRRIGATION LEGEND) <br />SCH 80 PVC <br />4 <br />SCH 40 PVC <br />5 <br />6 <br />FOUR (4) 4" X 8" BRICKS <br />3/8" WELDED WIRE MESH <br />7 <br />8 <br />3" THICK LAYER OF PEA GRAVEL <br />OR APPROVED EQUAL <br />MAINLINE <br />9 <br />SCH 80 PVC NIPPLE TXS <br />10 <br />SCH 80 PVC UNION SXS <br />10 <br />12 FINISHED GRADE <br />4 <br />SCALE: 1 1 <br />2" = 1'=0" <br />6" <br /> <br />M <br />I <br />N <br />. <br /> <br />12 <br />" <br />MA <br />X <br />. <br />LEGEND <br />PVC SCH 40 STREET ELL-1" <br />PVC MAINLINE PIPE <br />PVC SCH 40 ELL-1" <br />BRICK SUPPORTS (2) <br />3/4" MINUS WASHED GRAVEL <br />FINISH GRADE <br />VALVE BOX WITH COVER <br />PVC SCH 40 STREET ELL-1" <br />PVC SCH 80 NIPPLE-1" <br />(LENGTH AS REQUIRED) <br />QUICK-COUPLING VALVE <br />TWO-PIECE BODY WITH 1" INLET <br />AND 1" KEY OUTLET <br />NOTES: <br />1.FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL <br />TO NOMINAL QUICK COUPLING VALVE INLET SIZE. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />PVC SCH 40 , TEE OR ELL X 1" <br />1 <br />3 <br />SCALE: 1 1 <br />2" = 1'-0" <br />4 <br />5 <br />7 <br />5 8 <br />2 <br />6 11 10 9 <br />PLD FITTING <br />LEGEND <br />SCALE: 1 1 <br />2" = 1'=0" <br />1 <br />2 <br />PLD-TEE <br />PLD-ELB <br />PLD-CPL <br />PLD-CAP <br />PLD-BV <br />PROFESSIONAL LANDSCAPE DRIPLINE <br />1 <br />2 <br />1 <br />2 <br />2 1 <br />1 2 1 2 <br />PROFESSIONAL LANDSCAPE DRIPLINE <br />PLD FITTING <br />PVC LATERAL - AS PER PLAN <br />PLD-075 <br />PLD-050 <br />PLD-075-TBTEE <br />LEGEND <br />SCALE: 1 1 <br />2" = 1'=0" <br />1 <br />2 <br />3 <br />1 <br />2 <br />3 <br />1 <br />2 <br />3 <br />1 <br />3 <br />2 <br />SCALE: 1 1 <br />2" = 1'=0" <br />LEGEND <br />DRIPLINE (HDL) PER PLAN <br />FINISHED GRADE <br />RISER - LENGTH AS REQUIRED <br />PLD OR PLD-LOC FITTING <br />MULCH (AS SPECIFIED) <br />1 <br />2 <br />3 <br />4 <br />5 <br />SOIL6 <br />PLD OR PLD-LOC FITTING7 <br />PVC SUPPLY HEADER - SIZE PER PLAN8 <br />DEPTH PER <br /> PLAN <br />1 <br />2 <br />3 <br />4 <br />8 <br />7 <br />5 <br />6 <br />SCALE: 1 1 <br />2" = 1'=0" <br />LEGEND <br />DRIPLINE (HDL) PER PLAN <br />FINISHED GRADE <br />RISER - LENGTH AS REQUIRED <br />PLD OR PLD-LOC FITTING <br />MULCH (AS SPECIFIED) <br />DEPTH PER <br /> PLAN <br />1 <br />1 <br />2 <br />3 <br />4 <br />5 <br />SOIL6 <br />PLD OR PLD-LOC FITTING7 <br />PVC SUPPLY HEADER - SIZE PER PLAN8 <br />2 <br />3 <br />4 <br />8 <br />7 <br />5 <br />6 <br />HARDSCAPE <br />AS SPECIFIED <br />APPROX.4" (10.1 CM) <br />HARDSCAPE <br />AS <br /> <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />E <br />D <br />RAINBIRD DRIPLINE PER PLAN1 <br />2 <br />3 <br />4 <br />5 <br />DRIP CONTROL ZONE KIT PER PLAN <br />AIR RELIEF VALVE IN VALVE BOX <br />ECO-INDICATOR ON SWING ARM <br />PLD OR PLD-LOCK FITTING (TYP.) <br />6 FLUSH POINT (PLD-BV) IN <br />SUBTERRANEAN BOX PER PLAN <br />NOTES <br />1.AIR RELIEF VALVE (PLD-AVR) INSTALLED IN VALVE BOX AT OPTIMAL HIGHEST POINT FROM CONTROL ZONE <br />KIT. <br />2.MULTIPLE AIR RELIEF VALVES MAY BE NEEDED TO ACCOMMODATE DIFFERENCES IN GRADE. ECO-INDICATOR <br />TO BE INSTALLED AT OPTIMAL FURTHEST POINT FROM CONTROL ZONE KIT IN CLEAR VIEW WHEN POPPED UP. <br />3. FLUSH POINT TO BE INSTALLED AT OPTIMAL FURTHEST POINT FROM CONTROL ZONE KIT TO ALLOW FOR <br /> MAXIMUM DEBRIS FLUSH IN SYSTEM. <br />SCALE: 1 1 <br />2" = 1'=0" <br />1 <br />2 <br />3 <br />6 <br />5 <br />4 <br />LEGEND <br />AUTOMATIC FLUSH VALVE WITH 5/8" [17 mm] BARB CONNECTION, <br />MODEL AFV-T. <br />SCALE: 1 1 <br />2" = 1'=0" <br />1 <br />3 <br />LEGEND <br />RECTANGULAR PLASTIC VALVE BOX AND LID (MB-0811). <br />LID COLORS: STANDARD BLACK, PURPLE FOR RECYCLED WATER USE, AND OTHER <br />COLORS AVAILABLE. <br />2 <br />FINISHED GRADE3 <br />GRAVEL BASE, DEPTH AS SPECIFIED4 <br />COMMON HALF BRICK, 2 TOTAL, INSTALL ONE ON EACH SHORT SIDE OF BOX.5 <br />FEMALE ADAPTER PER PLAN, SLIP X FPT6 <br />LATERAL LINE PER PLAN7 <br />2 <br />1 <br />6 <br />SE <br />E <br /> <br />L <br />E <br />G <br />E <br />N <br />D <br />7 <br />5 <br />4 <br />SCALE: 1 1 <br />2" = 1'=0" <br />1 FINISH GRADE <br />2 AIR/VACUUM RELIEF VALVE <br />2 <br />1 <br />3 <br />3 6" ROUND VALVE BOX <br />4 <br />4 1/2" PVC COUPLING (TXT) <br />5 1/2" SCH 80 RISER (LENGTH AS <br />REQUIRED) <br />6 BRICK SUPPORTS (THREE) <br />7 3/4" GRAVEL SUMP (1 CUBIC FOOT) <br />5 <br />6 <br />7 <br />8 <br />8 PVC PIPE AND FITTINGS <br />LEGEND <br />VALVE BOX W/ LOCKING LID1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />WATER PROOF WIRE CONNECTORS <br />CONTROLLER WIRES W/ 24" MIN. EXPANSION CURLS <br />3/8" WELDED WIRE MESH <br />FOUR (4) 4" X 8" BRICKS <br />SCALE: 1 1 <br />2" = 1'=0" <br />24" min. <br />NOTE: <br />1.VALVE BOXES SHALL BE LOCATED IN PLANTING AREAS. <br />2.SPLICES SHALL ONLY BE MADE AT ELECTRICAL PULL BOXES. <br />3.LOW VOLTAGE WIRES UNDER ROADWAYS MUST BE IN CONTINUOUS CONDUIT WITH 90° SCH. <br />40 PVC SWEEPS TERMINATING IN PULL BOXES. <br />4.ALL WIRE CONNECTIONS SHALL BE MADE USING DBR/Y-6 CONNECTORS OR APPROVED <br />EQUAL. <br />5.VALVE BOX SHALL BE WRAPPED WITH MINIMUM 3 MIL. THICK PLASTIC AND SECURE IT USING <br />DUCT TAPE OR ELECTRICAL TAPE. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />FOUR (4) 4" X 8"DIRECT BURIAL (LOW <br />VOLTAGE) IRRIGATION CONTROLLER <br />WIRES <br />PAVEMENT <br />FINISHED GRADE <br />7 <br />8 <br />LEGEND <br />FINISHED SURFACE OR VEHICULAR PARKING1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />11 <br />COMPACT BACKFILL <br />SUBGRADE <br />PRESSURE MAINLINE PIPE <br />TWO-WIRE CABLE SLEEVE - MIN. 2" <br />LATERAL PIPE IN SLEEVE <br />SCALE: 1 1 <br />2" = 1'=0" <br />MA <br />I <br />N <br />L <br />I <br />N <br />E <br /> <br />P <br />I <br />P <br />E <br />SE <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br />LA <br />T <br />E <br />R <br />A <br />L <br />SE <br />E <br /> <br />B <br />E <br />L <br />O <br />W <br />6" <br />2" <br />2" <br />6" <br />PIPE TYPE LOCATION SIZE DEPTH <br />PRESSURE <br />MAINLINE <br />NON-PRESSURE <br />LATERAL LINE <br />LANDSCAPE <br />VEHICULAR <br />PAVING <br />LANDSCAPE <br />VEHICULAR <br />PAVING <br />< 3' <br />3' + <br />< 3' <br />3' + <br />< 3' <br />3' + <br />< 3' <br />3' + <br />24" <br />36" <br />30" <br />36" <br />12" <br />18" <br />24" <br />30" <br />ANY IRRIGATION SLEEVES OR PIPES ADJACENT TO <br />BUILDING FOUNDATION, PLEASE REFERENCE DETAIL <br />7/S3.01. <br />ADDITIONAL TRENCHING NOTES: <br />NOTES: <br />1.ALL SLEEVES TO BE TWICE THE DIAMETER OF THE <br />CARRIER PIPE. <br />2.NON- DOMESTIC WATER PIPE SLEEVES SHALL BE <br />IDENTIFIED PER WATER DISTRICT STANDARDS. <br />3.ALL SLEEVES SHALL EXTENDED A MINIMUM OF 12". <br />1 <br />DEBRIS AND ROCK FREE BACKFILL <br />(OR SAND) <br />2 <br />3 4 5 <br />6 <br />7 <br />LEGEND <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />DATE ISSUED: <br />PROJECT NO: <br />10/23/2023 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br />A <br />S <br />T <br /> <br />C <br />E <br />N <br />T <br />R <br />A <br />L <br /> <br />A <br />V <br />E <br />N <br />U <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />DESCRIPTION DATE <br />2022-40198 <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />As Noted <br />SHEET <br />NUMBER:L5.401 <br />LANDSCAPE <br />IRRIGATION <br />DETAILS <br />E <br />H <br />RP <br />F <br />A <br />K M DRIPLINE CONNECTION <br />J <br />T TREE DRIP RING <br />GATE VALVE <br />-G I <br />C <br />BALL VALVEAUTOMATIC FLUSH VALVEVACCUM RELIEF VALVE <br />B DSPLICE BOXTRENCHING <br />AS SPECIFIED <br />AS <br /> <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />E <br />D <br />1 <br />5 <br />4 <br />2 <br />3 <br />6 <br />7 <br />8 <br />SCALE: 1 1 <br />2" = 1'=0" <br />NOTES <br />AIR RELIEF VALVE (PLD-AVR) INSTALLED IN VALVE BOX AT OPTIMAL HIGHEST <br />POINT FROM CONTROL ZONE KIT. MULTIPLE AIR RELIEF VALVES MAY BE <br />NEEDED TO ACCOMMODATE DIFFERENCES IN GRADE. ECO-INDICATOR TO <br />BE INSTALLED AT OPTIMAL FURTHEST POINT FROM CONTROL ZONE KIT IN <br />CLEAR VIEW WHEN POPPED UP. FLUSH POINT TO BE INSTALLED AT OPTIMAL <br />FURTHEST POINT FROM CONTROL ZONE KIT TO ALLOW FOR MAXIMUM <br />DEBRIS FLUSH IN SYSTEM. <br />HUNTER DRIPLINE (HDL) PER PLAN1 <br />2 <br />3 <br />4 <br />5 <br />ECO-INDICATOR ON SWING ARM <br />PLD OR PLD-LOC FITTINGS TYP. <br />AIR RELIEF VALVE IN VALVE BOX <br />HDL TUBING EXHAUST HEADER <br />6 <br />8 DRIP CONTROL ZONE PER KIT <br />LEGEND <br />FLUSH POINT (PLD-BV) IN <br />SUBTERRANEAN BOX PER PLAN <br />5 HDL TUBING EXHAUST HEADER <br />PVC - POLY FITTINGL DRIPLINE CONNECTION - 90T <br />IRREGULAR DRIPLINE PLANTING <br />N POLY - TO - POLY FITTING <br />REGULAR DRIPLINE PLANTING <br />QUICK COUPLING VALVE DRIP CONTROL KIT W/ FILTER <br />O DEEP ROOT WATERING SYSTEM <br />- <br />2 <br />3 <br />4 <br />1 <br />5 <br />LEGEND <br />NOTES: <br />1.AIR RELIEF VALVE (PLD-AVR) INSTALLED IN <br /> VALVE BOX AT OPTIMAL HIGHEST POINT FROM <br /> CONTROL ZONE KIT. MULTIPLE AIR RELIEF VALVES <br /> MAY BE NEEDED TO ACCOMMODATE DIFFERENCES IN GRADE. <br />2.ECO-INDICATOR TO BE INSTALLED AT OPTIMAL FURTHEST <br /> POINT FROM CONTROL ZONE KIT IN CLEAR VIEW WHEN <br /> POPPED UP. <br />3.FLUSH POINT TO BE INSTALLED AT OPTIMAL FURTHEST <br /> POINT FROM CONTROL ZONE KIT TO ALLOW FOR MAXIMUM <br /> DEBRIS FLUSH IN SYSTEM. <br />RAINBIRD DRIPLINE (HDL) <br />PER PLAN <br />PLD OR PLD-LOC FITTING TYP. <br />PVC TO DRIP LINE TUBING <br />CONNECTION <br />(PLD OR PLD-LOC FITTINGS) TYP. <br />PVC LATERAL LINE <br />TREE (SEE PLANTING PLAN) <br />SCALE: 1 1 <br />2" = 1'=0" <br />1 <br />2 <br />3 <br />4 <br />5 <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.