U.C. <br />Refr. <br />NEW METAL STUD WALL PER SHEET A61.1 <br />EXISTING METAL STUD WALL <br />EXISTING CONCRETE WALL <br />NOT IN SCOPE <br />2-HR RATED FIRE BARRIER <br />1-HR RATED FIRE PARTITION <br />WALL TYPE ANNOTATIONS, SEE SHEET <br />A61.1 FOR DETAILS <br />1 <br />101 NUMBER INDICATES DOOR PER SCHEDULE, <br />REFER TO SHEET A52.1 <br />NUMBER INDICATED WINDOW PER SCHEDULE, <br />REFER TO SHEET A53.1 <br />EXISTING FIRE EXTINGUISHER CABINET <br />FLOOR PLAN GENERAL NOTES: <br />1. ALL DIMENSIONS ARE TO CENTERLINE OF THE GRID LINES AND/OR TO THE <br />FACE OF STUDS, U.N.O. <br />2. UNLESS NOTED OTHERWISE, ALL WALLS ARE FULL HEIGHT. <br />3. REFER TO SHEET GEN-4 FOR TYPICAL ACCESSIBILTY REQUIREMENTS AND <br />DIMENSIONS. <br />4. REFER TO ENLARGED PLANS FOR DIMENSIONS AND CALLOUTS NOT <br />SHOWN HERE. <br />1i <br />60" MIN. ACCESSIBLE WHEELCHAIR <br />CLEAR TURNING SPACE <br />CLR. 60" MIN. <br />30"X48" MIN. ACCESSIBLE WHEELCHAIR <br />CLEAR FLOOR SPACE <br />30"X48" <br /> CLR. <br />1-HR RATED FIRE BARRIER <br />A21.3 8 <br />2 <br />A21.1 <br />1 <br />A21.1 <br />3 <br />A21.1 <br />A21.2 <br />2 <br />SF1 <br />1/ A52.2 <br />SF2 <br />2/ A52.2 <br />SF3 <br />3/ A52.2 <br />504 SF <br />CHILDRENS <br />AREA <br />5 <br />293 SF <br />TEEN <br />AREA <br />4 <br />275 SF <br />OFFICE <br />1 <br />57 SF <br />RESTROOM <br />2 2 3 <br />4A21.31 <br />2 <br />3 <br />A21.3 <br />4 <br />5 <br />6 <br />A21.3 <br />7 <br />5' - 0" <br />11' - 5" <br />061000.B <br />061000.B <br />084410.A <br />061000.B <br />106100.A <br />A11.5 <br />2 <br />0007 <br />080000.B <br />M3.4 <br />M3.1 <br />M3.4 <br />M6.6 <br />M6.6 M3.4 M3.4 <br />M3.4 <br />M3.4 <br />M3.4 <br />M6.6 <br />M6.4 <br />M3.4 <br />M3.4 <br />M6.4 <br />32 <br />' <br /> <br />- <br /> <br />0 <br />" <br />7' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />9' <br /> <br />- <br /> <br />4 <br />" <br />14 <br />' <br /> <br />- <br /> <br />5 <br />" <br />32' - 7" <br />7"1' - 11" <br />6' - 0" <br />2' - 7" <br />7' - 7"7"5' - 0"18' - 6"2' - 6" <br />M3.4061000.A <br />13' - 2" <br />205 SF <br />READING <br />AREA <br />7 <br />5' - 0" <br />1 <br />A22.1 <br />2 <br />A22.1 <br />W1.6 <br />W1.6 <br />W7.4 <br />W7.4 <br />W1.6 <br />W7.4 <br />M3.4 <br />10 <br />A61.2 <br />1 <br />A21.3 <br />9 <br />260000.H <br />260000.I <br />260000.H <br />A21.4 <br />3 <br />124000.N <br />5 <br />107100.B <br />107100.B <br />107100.B107100.B <br />009 <br />10 <br />009 <br />1080 SF <br />GENERAL <br />STACKS <br />3 <br />3' - 6" <br />A B <br />D <br />D <br />D <br />E F <br />E F <br />H <br />H <br />H <br />G <br />G <br />C <br />099000.A <br />4' - 9" <br />2' <br /> <br />- <br /> <br />6 <br />" <br />R 1' - 0" <br />A63.3 <br />8 <br />F <br />080000.D <br />099000.A <br />A B C <br />1 <br />2 <br />3 <br />4 <br />A63.3 <br />48 <br />033000.G <br />27 <br />27 <br />27 <br />25 <br />2727 <br />084410.A <br />084410.A <br />064100.K <br />064100.B <br />A ALL-GENDER ACCESSIBLE TOILET ROOM SIGNAGE 4/GEN-5 <br />B ALL-GENDER SIGN 8/GEN-5 <br />C ACCESSIBLE ENTRY SIGN 9/GEN-5 <br />D ROOM IDENTIFICATION SIGN 11/GEN-5 <br />E TACTILE EXIT ROUTE SIGN 12/GEN-5 <br />F TACTILE EXIT SIGN 13/GEN-5 <br />G ASSISTIVE LISTENING SIGN 16/GEN-5 <br />H OCCUPANT LOAD SIGN 17/GEN-5 <br />DESCRIPTION DETAILNO. <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />As indicated <br />Issue Date <br />A11.3 <br />IMPROVEMENTS - <br />ENLARGED <br />PLANS <br />#2022-40198 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />B <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />FLOOR PLAN LEGEND <br />0007 ACCESSIBLE RESTROOMS <br />009 SAWCUT AND REMOVE HATCHED PORTION OF <br />EXISTING CONCRETE SLAB FOR POWER RUN TO <br />NEARBY FURNITURE, REPLACE SLAB IN KIND <br />FOLLOWING ELECTRICAL WORK, SEE E102 FOR <br />REQUIREMENTS AND ADDITIONAL INFORMATION (SLAB <br />TO BE REPLACED WITH NEW WORK) <br />033000.G (N) CONCRETE SLAB INFILL, SEE DET. 9/A52.4 <br />061000.A WOOD FRAMING, SEE STRUCTURAL DRAWINGS <br />061000.B (N) SHEER WALL: 2X12 STUD @ 16" OC W/MOISTURE <br />RESISTANT 5/8" GYP BRD EA SIDE & RUBBER WALL <br />BASE <br />064100.B WALL-MOUNTED COUNTERTOP, SEE DET. 03/A63.3 <br />064100.K WALL-MOUNTED COUNTERTOP, SEE DET. 05/A63.3 <br />080000.B NEW DOOR & FRAME & THRESHOLD, REF SPECS. <br />PAINT. ARCH. AND OWNER TO DETERMINE COLORS, <br />TYP <br />080000.D NEW CROWN SST-II HYDRAULIC BI-FOLD DOOR, REFER <br />TO A62.2 FOR ADDITIONAL INFORMATION. BLOCKING <br />FOR BI-FOLD MOTOR PER 4/S-1.1. <br />084410.A ALUMINUM-FRAMED STOREFRONT (INTERIOR) - SEE <br />DETAILS ON SHEET A62.3 <br />099000.A PAINT WALLS TO MATCH EXISTING. PATCH AND REPAIR <br />FINISHES TO MATCH EXISTING WHERE NEW WORK <br />MEETS EXISTING, TYP. <br />106100.A (E) RELOCATED MURAL <br />107100.B (N) FLOOR MOUNTED DESIGNER CLEAR SECURITY <br />GATE LIB-180 RFID SCANNER, SEE SPECS FOR <br />TYPE/SIZE, OFOI <br />124000.N WALL-MOUNTED IDF STORAGE CABINET, ADDITIONAL <br />BLOCKING REQ. CONTRACTOR TO CONFIRM SIZE WITH <br />I.T. SPECS, CFCI <br />260000.H INCLUDE POWER AND DATA TO COPY PRINT STATION <br />260000.I INCLUDE POWER AND DATA TO SELF CHECKOUT AND <br />LIBRARY KIOSK <br />KEYNOTES <br />1/4" = 1'-0"1IMPROVEMENTS ENLARGED FLOOR PLAN <br />DESCRIPTION DATE <br />SIGNAGE LEGEND <br />N <br />7/08/24 <br />505 E Central Ave <br />#B11/6/2024