|
+10' -6"
<br />+10' -6"
<br />+9' -6"
<br />+11' -6"
<br />+10' -6"
<br />+10' -6"
<br />+10' -4"
<br />+11' -0"
<br />+10' -6"
<br />+10' -6"
<br />+11' -6"
<br />+10' -6"
<br />+10' -4"
<br />+10' -6"
<br />260000.G
<br />230000.H
<br />083300.A
<br />+10' -6"6' - 0"
<br />1
<br />A22.12
<br />A22.1
<br />260000.C
<br />230000.J
<br />230000.I
<br />260000.C
<br />+10' -6"+10' -6"
<br />221000.K
<br />095100.C
<br />R 3' - 0"
<br />R 5' - 0"
<br />R 3' - 0"
<br />R 4' - 0"R 3' - 0"
<br />R 4' - 0"R 5' - 0"
<br />R 4' - 0"
<br />R 4' - 0"
<br />R 5' - 0"
<br />R 3' - 0"
<br />R 4' - 0"
<br />R 5' - 0"
<br />R 4' - 0"
<br />R 3' - 0"
<br />095100.B
<br />092116.D
<br />R 14' - 0"
<br />A B C
<br />1
<br />2
<br />3
<br />4
<br />NOTES:
<br />1. GYPSUM BOARD CEILINGS SHALL BE FRAMED WITH METAL STUD JOISTS, U.N.O. SEE
<br />DETAIL XX/XX FOR MORE INFORMATION.
<br />2. FOR SUSPENDED ACOUSTICAL CEILING, REFER TO SHEET A64.1.
<br />3. AT ALL ROOMS WITHOUT CEILINGS (LABELLED AS "EXP" ON PLAN AND/OR ON THE
<br />FINISH SCHEDULE), ALL EXPOSED SURFACES AND ELEMENTS SHALL BE PAINTED,
<br />INCLUDING STRUCTURE, DECK ABOVE, AND ALL UTILITIES INCLUDING PIPING,
<br />CONDUITS, DUCTWORK, ETC.
<br />4. PLUMBING, ELECTRICAL, MECHANICAL AND FIRE PROTECTION COMPONENTS
<br />ARE SHOWN FOR REFERNECE AND COORDINATION PURPOSES. REFER TO
<br />PLUMBING, ELECTRICAL, MECHANICAL AND FIRE PROTECTION DRAWINGS
<br />FOR COMPONENT AND SYSTEM QUANTITIES, TYPES AND REQUIREMENTS
<br />5. CENTER LIGHTING FIXTURES BETWEEN OPPOSITE WALLS, U.N.O.
<br />6. ALL DIMENSIONS, NOTES, KEYNOTES AND DETAILS CALLOUTS ARE TYPICAL, U.N.O.
<br />7. SEE SHEET A50.1 FOR INTERIOR FINISH LEGEND
<br />8. AT EXPOSED CEILINGS, ALL DUCTS, PIPES AND CONDUITS SHALL RUN PARALLEL OR
<br />PERPENDICULAR TO WALL, AND AS CLOSE TO THE DECK ABOVE AS POSSIBLE.
<br />PROVIDE ESCUTCHEONS FOR CONDUIT/PIPES AT WALLS WHERE EXPOSED.
<br />* REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF EMERGENCY LIGHTING.
<br />2' X 4' SUSPENDED CEILING TILES, REFER TO NOTE 2
<br />RECESSED SUPPLY AIR GRILL, SEE MECH. DRAWINGS
<br />RECESSED RETURN AIR GRILL, SEE MECH. DRAWINGS
<br />2X2 LUMINAIRE, SEE ELEC. DRAWINGS*
<br />RECESSED COMPACT FLUORESCENT DOWNLIGHT, SEE ELEC. DRAWINGS*
<br />S S SPEAKERS, SEE ELECTRICAL DRAWINGS
<br />EXIT SIGNAGE, SEE ELECTRICAL DRAWINGS
<br />SUSPENDED STRIP FLUORESCENT, SEE ELEC. DRAWINGS*
<br />SUSPENDED FLUORESCENT FIXTURE, SEE ELEC. DRAWINGS*
<br />RECESSED EXHAUST AIR GRILL, SEE MECH.
<br />DRAWINGS
<br />2X4 LUMINAIRE, SEE ELEC. DRAWINGS*
<br />GYP. BOARD CEILING, REFER TO NOTE 1
<br />ROOF HATCH ABOVE, REFER TO DET. 8/A62.6
<br />SURFACE MOUNTED FLUORESCENT FIXTURE, SEE ELEC. DRAWINGS*
<br />WALL MOUNTED FLUORESCENT LIGHT FIXTURE, SEE ELEC. DRAWINGS*
<br />WALL MOUNTED FLUORESCENT DOWNLIGHT, SEE ELEC. DRAWINGS*
<br />WALL MOUNTED TO BE 8' - 0" TYP.
<br />WALL MOUNTED FIXTURE AT STAIR, SEE ELEC. DRAWINGS*
<br />DECORATIVE PENDANT MOUNTED FIXTURE, SEE ELEC. DRAWINGS*
<br />2' X 2' SUSPENDED CEILING TILES, REFER TO NOTE 2
<br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS
<br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF
<br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY
<br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR
<br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA
<br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018.
<br />SCALE:
<br />REVISIONS:
<br />OW
<br />N
<br />E
<br />R
<br />:
<br />PR
<br />O
<br />J
<br />E
<br />C
<br />T
<br />
<br />N
<br />A
<br />M
<br />E
<br />:
<br />CL
<br />I
<br />E
<br />N
<br />T
<br />
<br />A
<br />D
<br />D
<br />R
<br />E
<br />S
<br />S
<br />:
<br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707
<br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM
<br />DATE ISSUED:
<br />PROJECT NO:
<br />As indicated
<br />Issue Date
<br />A11.4
<br />IMPROVEMENTS -
<br />REFLECTED
<br />CEILING PLAN
<br />#2022-40198
<br />CI
<br />T
<br />Y
<br />
<br />O
<br />F
<br />
<br />S
<br />A
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />DE
<br />L
<br />H
<br />I
<br />
<br />C
<br />O
<br />M
<br />M
<br />U
<br />N
<br />I
<br />T
<br />Y
<br />
<br />C
<br />E
<br />N
<br />T
<br />E
<br />R
<br />RE
<br />N
<br />O
<br />V
<br />A
<br />T
<br />I
<br />O
<br />N
<br />50
<br />5
<br />
<br />E
<br />
<br />C
<br />e
<br />n
<br />t
<br />r
<br />a
<br />l
<br />
<br />A
<br />v
<br />e
<br />,
<br />
<br />U
<br />n
<br />i
<br />t
<br />
<br />B
<br />,
<br />
<br />S
<br />a
<br />n
<br />t
<br />a
<br />
<br />A
<br />n
<br />a
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />7
<br />KEYNOTES
<br />083300.A OVERHEAD FOLDING DOOR, REFER TO DOOR
<br />SCHEDULE FOR TYPE AND FINISH, SEE SHEET A62.2
<br />FOR ADDITIONAL INFORMATION
<br />092116.D (N) 5/8" MOISTURE RESISTANT GYP BD CEILING, SEE
<br />SHEET 13/A52.4 FOR DETAILS
<br />095100.B SUSPENDED ACOUSTICAL CIRCULAR CEILING CLOUDS
<br />W/ PRE-FINISHED FLOATING EDGE (12" FROM
<br />SURROUNDING WALLS), SEE DET. 19/A52.4 AND SPECS,
<br />TYP. REFER TO A50.1 FOR CEILING FINISH ABOVE
<br />CEILING CLOUDS.
<br />095100.C SUSPENDED ACOUSTICAL CEILING TILES, SEE SHEET
<br />A/9.2 FOR DETAILS
<br />221000.K EXISTING FIRE SPRINKLER AND FIRE ALARM SYSTEMS
<br />ARE TO BE MODIFIED ON A PERFORMANCE BASED
<br />DEFFERED APPROVAL
<br />230000.H NEW EXHAUST FAN TO BE INSTALLED, REFER TO
<br />MECHANICAL
<br />230000.I NEW MECHANICAL SUPPLY, REFER TO MECHANICAL
<br />230000.J NEW MECHANICAL RETURN, REFER TO MECHANICAL
<br />260000.C LIGHTING FIXTURE, SEE ELECTRICAL DRAWINGS
<br />260000.G (N) 8" RECESSED DOWN LIGHT
<br />1/4" = 1'-0"1IMPROVEMENTS REFLECTED CEILING PLAN IMPROVEMENT RCP LEGEND
<br />DESCRIPTION DATE
<br />N
<br />7/08/24
<br />505 E Central Ave
<br />#B11/6/2024
|