My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />27 <br />1.00 SPECIAL PROVISIONS - CONSTRUCTION <br />1.01 ROCK PRODUCTS <br />Alternate rock products, asphalt concrete, Portland cement concrete (PCC), and untreated <br />base material shall be alternate rock material – Type S per Section 400 of the Standard <br />Specifications. <br />1.02 RELATIVE COMPACTION TESTS <br />The following test methods shall be used for determining relative compaction: <br /> California Test 216 (Sand Cone Method) <br /> California Test 231 (Nuclear Gauge Method) <br />The Contractor will be provided with compaction test at locations deemed necessary by <br />the Engineer. If compaction fails to meet the contract specifications, then the Contractor <br />shall make the necessary adjustments and is responsible for the cost of additional <br />compaction tests until compaction per the specifications is met. <br />1.03 CLEARING AND GRUBBING <br />Clearing and Grubbing shall be performed in conformance with the provisio ns of Section <br />300-1 of the Standard Specifications and these Special Provisions. <br />The following is added to Section 300-1.2 Preservation of Property: <br />Modify and/or repair existing sprinklers in project area that are damaged due to <br />the Contractor's operation within 24 hours. <br />1.04 UNCLASSIFIED EXCAVATION <br />This section shall conform to Subsection 300-2 and 300-4 of the Standard Specifications <br />and these Special Provisions. <br />Unclassified excavation shall consist of all excavation including sawcutting and removal <br />of roadways, bituminous pavement, concrete pavement, pavement fabric, and the removal <br />of curbs, sidewalks, driveways, alleys, cross-gutters, dirt, etc. as shown on the plans. <br />Any cores provided are included in the Appendix for reference purposes only and are not <br />part of the contract documents. The AGENCY will not be held responsible for existing <br />conditions that differ from any core logs that may be provided. It is the Contractor’s <br />option to take his/her own core samples to verify the existing conditions. <br />1.05 SUBGRADE PREPARATION <br />Subgrade preparation shall conform to Section 301-1 of the Standard Specification and <br />these Special Provisions. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.