My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
505 E Central Ave #B - DEF 1 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Central Ave
>
505 E Central Ave Unit# B
>
505 E Central Ave #B - DEF 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 5:01:47 AM
Creation date
2/24/2026 5:00:42 AM
Metadata
Fields
Template:
Plan
Permit Number
20181754
30146722
40138703
101117766
101124090
Full Address
505 E Central Ave Unit# B
Street Number
505
Street Direction
E
Street Name
Central
Street Suffix
Ave
Unit Number
B
Document Relationships
101117766 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
101124090 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
20181754 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
30146722 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
40138703 - Permit
(Permit - Plan)
Path:
\Building\Permits\C\Central Ave\505 E Central Ave Unit# B
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
994
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br /> <br />30 <br />The application of slurry shall be scheduled to commence after 8:00 a.m., and no <br />slurry operations shall be done after 2:00 p.m. unless otherwise approved by the <br />Engineer. Slurry shall be sufficiently cured for vehicle traffic without tracking or <br />damage to the surface by 3:00 p.m. on the same day. In case of damage done by <br />vehicles and/or pedestrians upon slurry that has not been sufficiently, the <br />Contractor shall replace all of the damaged work at the Contractor’s expense and <br />no additional compensation shall be made by the AGENCY. Final striping shall <br />be installed per Section 2.02, Striping (Traffic Stripes and Pavement Markings), <br />of these Special Provisions. <br />Section 302-4.9 entitled “Field Sampling and Testing” of the Standard Specifications <br />shall be modified to add the following: <br />Upon the Engineer’s direction, the Contractor shall slurry seal test sections within <br />the construction limits for each batch of slurry mix. No slurry shall be applied <br />until the test slurry sections have been approved by the Engineer. The costs of <br />these slurry tests shall be included in the unit price for slurry seal surfacing and no <br />additional compensation will be allowed therefore. <br />Section 302-4.10 entitled “Measurement” of the Standard Specifications shall be <br />modified to add the following: <br />Licensed weighmaster’s certificates showing gross, tare, and net weight of each <br />truck load of slurry mix shall be submitted to the Engineer by the Contractor for <br />each working day of slurry operation. <br />1.08 ASPHALT CONCRETE <br />Asphalt concrete construction shall conform to Section 200, 203, 302 and 400 of the <br />Standard Specifications, Section 92 of the Caltrans Standard Specifications and these <br />Special Provisions. <br />Coarse aggregate shall consist of material which at least 75% by weight shall be crushed <br />particles in lieu of the requirements of Section 400-4.2.3. <br />Tack coat is required and the cost thereof shall be included in the price paid per ton for <br />asphalt concrete. <br />The required asphalt concrete mix designs shall be as follows: <br /> Base Course III-B3-AR-4000 or PG 64-10 <br /> Leveling Course/Surface Course III-C3-AR-4000 or PG 64-10 <br /> Crack Filler III-F-AR-4000 or PG 64-10 <br />The top layer of asphalt concrete pavement shall be a leveling course that shall not <br />exceed 0.10' in compacted thickness. The leveling course shall be applied over both cold <br />mill and reconstruction areas concurrently. <br />505 E Central Ave <br />#B11/6/2024
The URL can be used to link to this page
Your browser does not support the video tag.