Laserfiche WebLink
AL - ALUMINUM <br />AC - ANODIZED CLEAR <br />BZ - ANODIZED BRONZE <br />CC - CONCEALED CLOSER <br />CLR - CLEAR <br />FC - FLOOR CLOSER <br />FF - FACTORY FINISH <br />FLFD - FUSIBLE LINK FIRE DAMPER <br />FP - FIELD PAINT <br />FPFP - FACTORY PRIMED, FIELD PAINTED <br />FRA - FIRE RATED ASSEMBLY <br />FS - FIELD STAINED <br />GA - GALVANIZED <br />GL - GLASS OR GLAZING <br />GS - GALVANIZED STEEL <br />HM - HOLLOW METAL <br />KY - FLUOROPOLYMER FINISH (SEE SPECS) <br />LVR - LOUVER <br />MF - MILL FINISH <br />MR - MIRRORED GLASS <br />MAG - MAGNETIC HOLD OPEN <br />P - PAINTED (FOR EXISTING FRAMES - PAINT SHALL INCLUDE PREP AND REPAIR OF <br />EXISTING FRAME, TYPICAL) <br />PG - PAINT GRADE <br />PH - PANIC HARDWARE <br />PR - PAIR <br />SCW - SOLID CORE WOOD <br />SG - STAIN GRAIN <br />SMC - SURFACE MOUNTED CLOSER <br />ST - STEEL <br />SS - STAINLESS STEEL <br />TEMP - TEMPERED <br />WV - WOOD VENEER <br />F FLUSH <br />HE <br />I <br />G <br />H <br />T <br /> <br />P <br />E <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />WIDTH PER SCHED. <br />PAIR WHERE OCCURS - NOTED <br />IN SCHEDULE WITH DOUBLE <br />TAG, I.E. 'G-G'' <br />FG FULL GLASS <br />HE <br />I <br />G <br />H <br />T <br /> <br />P <br />E <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />WIDTH PER SCHED. <br />PAIR WHERE OCCURS - NOTED <br />IN SCHEDULE WITH DOUBLE <br />TAG, I.E. 'FG-FG'' <br />TEMPERED <br />GLASS <br />@ <br />R <br />A <br />T <br />E <br />D <br /> <br />D <br />O <br />O <br />R <br />S <br />54 <br />" <br /> <br />M <br />A <br />X <br />. <br />1' <br /> <br />- <br /> <br />0 <br />" <br />2' - 0"6" <br />SG SLIDING GLASS <br />WIDTH PER SCHED. <br />PAIR WHERE OCCURS - NOTED <br />IN SCHEDULE WITH DOUBLE <br />TAG, I.E. 'G-G'' <br />HE <br />I <br />G <br />H <br />T <br /> <br />P <br />E <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />2' - 0" <br />5' <br /> <br />- <br /> <br />6 <br />" <br />B BI-FOLD <br />HE <br />I <br />G <br />H <br />T <br /> <br />P <br />E <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />WIDTH PER SCHEDULE <br />THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS <br />INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF <br />EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY <br />NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR <br />DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA <br />ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018. <br />SCALE: <br />REVISIONS: <br />OW <br />N <br />E <br />R <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />CL <br />I <br />E <br />N <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br />6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707 <br />T 949.809.3380 WWW.SVA-ARCHITECTS.COM <br />DATE ISSUED: <br />PROJECT NO: <br />1/4" = 1'-0" <br />Issue Date <br />A52.1 <br />DOOR & WINDOW <br />SCHEDULE <br />#2022-40198 <br />CI <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />DE <br />L <br />H <br />I <br /> <br />C <br />O <br />M <br />M <br />U <br />N <br />I <br />T <br />Y <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />RE <br />N <br />O <br />V <br />A <br />T <br />I <br />O <br />N <br />50 <br />5 <br /> <br />E <br /> <br />C <br />e <br />n <br />t <br />r <br />a <br />l <br /> <br />A <br />v <br />e <br />, <br /> <br />U <br />n <br />i <br />t <br /> <br />B <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />WINDOW SCHEDULE <br />Type Mark WIDTH HEIGHT <br />FRAME <br />GLAZING <br />DETAILS <br />SILL HEIGHT FIRE RATING Phase CreatedMATERIAL FINISH HEAD DETAIL JAMB SILL DETAIL <br />27 5' - 8" 6' - 10" ALUMINUM PTD. TEMP. 2/A62.3 3/A62.3 1/A62.3 3' - 4 1/2" EXISTING <br />27 5' - 8" 6' - 10" ALUMINUM PTD. TEMP. 2/A62.3 3/A62.3 1/A62.3 3' - 4 1/2" EXISTING <br />27 5' - 8" 6' - 10" ALUMINUM PTD. TEMP. 2/A62.3 3/A62.3 1/A62.3 3' - 4 1/2" EXISTING <br />27 5' - 8" 6' - 10" ALUMINUM PTD. TEMP. 2/A62.3 3/A62.3 1/A62.3 3' - 4 1/2" EXISTING <br />27 5' - 8" 6' - 10" ALUMINUM PTD. TEMP. 2/A62.3 3/A62.3 1/A62.3 3' - 4 1/2" EXISTING <br />25 13' - 4" 7' - 2" ALUMINUM PTD. TEMP. 2/A62.3 3/A62.3 1/A62.3 3' - 0" EXISTING <br />1. ALL GLAZING SHALL COMPLY WITH CBC CHAPTER 24. <br />2. GLASS DOORS, ADJACENT PANELS AND ALL GLAZED OPENINGS SHALL BE APPROVED FOR <br />IMPACT HAZARD PER CBC CHAPTER 24. PROVIDE IDENTIFICATION OF GLAZING PER SECTION <br />2406.3. <br />3. REFER TO OVERALL BUILDING PLANS FOR WINDOW TYPE DESIGNATION. REFER TO WINDOW <br />TYPE ELEVATIONS ON THIS SHEET FOR OPERABLE WINDOW DESIGNATIONS, IF ANY. ALL WINDOW <br />SIZES ARE NOMINAL - VERIFY EXACT DIMENSIONS WITH MANUFACTURERS. <br />4. SEE WINDOW TYPES FOR WINDOW MULLION CONFIGURATIONS. <br />5. REFER TO SPECIFICATIONS FOR ADDITIONAL WINDOW AND GLAZING INFORMATION. <br />6. VERIFY ALL HEADER HEIGHTS WITH ELEVATIONS. <br />7. WINDOWS TO BE CONSTRUCTED OF MULTIPANE GLAZING WITH A MINIMUM OF ONE TEMPERED <br />PANE MEETING THE REQUIREMENTS OF CBC SECTION 2406 FOR SAFETY GLAZING. <br />WINDOW SCHEDULE <br />ABBREVIATIONS GENERAL NOTES - WINDOWS <br />DOOR SCHEDULE <br />Mark <br />DOOR <br />TYPE WIDTH HEIGHT <br />DOOR FRAME DETAILS <br />PH Phase Created <br />HARDWARE <br />SET CommentsMATERIAL MATERIAL FINISH HEAD DETAIL JAMB DETAIL <br />1 12' - 10" 10' - 2 3/8" ALUMINUM AND <br />GLASS <br />ALUMINUM PTD. 5/A62.3 7/A62.2 NEW <br />CONSTRUCTION <br />1 CROWN DOORS SST-II HYDRAULIC BI-FOLD SYSTEM. REFER <br />TO SPEC 08 34 16 FOR ADDITIONAL INFORMATION <br />2 F 3' - 0" 7' - 0" SOLID CORE WOOD WOOD PTD. 6/A62.1 6/A62.1 NEW <br />CONSTRUCTION <br />3 ATTACH RESTROOM SIGNAGE, SEE DET. 6,7,8/GEN-5, EQUIP <br />PANIC HARDWARE <br />3 SG 3' - 0" 7' - 0" SOLID CORE WOOD WOOD PTD. 6/A62.1 6/A62.1 NEW <br />CONSTRUCTION <br />4 EQUIP PANIC HARDWARE <br />4 FG-FG 6' - 0 <br />15/32" <br />7' - 0" ALUMINUM AND <br />GLASS <br />ALUMINUM PTD. 2/A62.1 1/A62.1 YES NEW <br />CONSTRUCTION <br />5 EQUIP PANIC HARDWARE <br />5 FG-FG 4' - 5 1/2" 8' - 0" ALUMINUM AND <br />GLASS <br />ALUMINUM PTD. 1/A62.2 2/A62.2 YES NEW <br />CONSTRUCTION <br />AUTOMATIC SLIDING DOORS TO BE EQUIPPED WITH PANIC <br />HARDWARE SWING PANELS THAT SHALL REQUIRE NO MORE <br />THAN 50 LBS OF FORCE TO OPEN. <br />Grand total: 5 <br />DOOR LEGEND <br />AL - ALUMINUM <br />AC - ANODIZED CLEAR <br />BZ - ANODIZED BRONZE <br />CC - CONCEALED CLOSER <br />CLR - CLEAR <br />FC - FLOOR CLOSER <br />FF - FACTORY FINISH <br />FLFD - FUSIBLE LINK FIRE DAMPER <br />FP - FIELD PAINT <br />FPFP - FACTORY PRIMED, FIELD PAINTED <br />FRA - FIRE RATED ASSEMBLY <br />FS - FIELD STAINED <br />GA - GALVANIZED <br />GL - GLASS OR GLAZING <br />GS - GALVANIZED STEEL <br />HM - HOLLOW METAL <br />KY - FLUOROPOLYMER FINISH (SEE SPECS) <br />LVR - LOUVER <br />MF - MILL FINISH <br />MR - MIRRORED GLASS <br />MAG - MAGNETIC HOLD OPEN <br />P - PAINTED (FOR EXISTING FRAMES - PAINT SHALL INCLUDE <br />PREP AND REPAIR OF EXISTING FRAME, TYPICAL)A\ <br />PG - PAINT GRADE <br />PH - PANIC HARDWARE <br />PR - PAIR <br />SCW - SOLID CORE WOOD <br />SG - STAIN GRAIN <br />SMC - SURFACE MOUNTED CLOSER <br />ST - STEEL <br />SS - STAINLESS STEEL <br />TEMP - TEMPERED <br />1. LETTER "P" FOLLOWING DOOR TYPE LETTER IN SCHEDULE INDICATES A PAIR OF DOORS. <br />SCHEDULED DIMENSION IS TOTAL FRAME OPENING. BOTH DOOR LEAVES ARE THE SAME SIZE <br />UNLESS OTHERWISE NOTED. <br />2. LETTER "X" FOLLOWING DOOR TYPE LETTER IN SCHEDULE INDICATES A FIXED PANEL <br />ABOVE DOOR LEAF. DOOR LEAF IS TO BE 7'-0" HIGH. SCHEDULED DIMENSION IS HEIGHT OF <br />ACTIVE DOOR LEAF PLUS FIXED PANEL. FIXED PANEL SHALL BE OF SAME MATERIAL, <br />CONSTRUCTION, THICKNESS, AS FINISH AS ACTIVE DOOR AND PROVIDED BY THE SAME <br />MANUFACTURER AS DOOR. <br />3. LOUVERS IN FIRE-RATED DOOR ASSEMBLIES TO BE FLFD (FUSIBLE LINK FIRE DAMPER), <br />LOUVERS IN EXTERIOR DOORS TO BE VANDAL-PROOF SECURITY TYPE. <br />4. GLAZING, ALL GLAZING PANELS IN FIRE-RATED DOOR ASSEMBLIES TO BE RATED GLASS. <br />ALL OTHER GLAZING PANELS IN DOORS TO BE TEMPERED GLASS UNLESS OTHERWISE NOTED. <br />5. ALL DOORS NOTED AS 1-HOUR, AND 1 1/2-HOUR FIRE-RATED ASSEMBLIES SHALL MEET THE <br />ADDITIONAL REQUIREMENTS OF MAXIMUM 450 F TEMPERATURE RISE ABOVE AMBIENT AFTER <br />30 MINUTES OF THE FIRE TEST. (CBC SEC. 1005.3.3.5 AND 1005.3.4.4). <br />6. THICKNESS: ALL DOORS TO BE 1 3/4" THICK UNLESS OTHERWISE NOTED. <br />7. ALL EXTERIOR DOORS TO HAVE WEATHERSTRIPPING ALL SIDES PER TITLE 24, SECTION <br />T20-1451-1542. <br />8. ALL WOOD DOORS TO BE SOLID-CORE TYPE. <br />9. EXIT DOORS SERVING 50 OR MORE OCCUPANTS SHALL OPEN IN THE DIRECTION OF EXIT. <br />10. EVERY EXIT DOOR SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR <br />ANY SPECIAL KNOWLEDGE OR EFFORT. ANY SPECIAL LOCKING DEVICES SHALL BE OF THE <br />APPROVED TYPE. CBC CHAPTER 33 AND UFC SECTION 12,104(B). <br />11. DOOR HARDWARE SHALL COMPLY WITH THE FOLLOWING PER CBC 11B-404.2.7 <br />1. OPERABLE BY A SIMPLE EFFORT, NOT GRASPING WRIST MOVEMENT (LEVERS, PANIC <br />DEVICES, OR PULLS). <br />2. 5-LB CLOSURE PRESSURE AT INTERIOR DOORS. <br />3. 5-LB CLOSURE PRESSURE AT EXTERIOR DOORS. <br />4. 5-LB CLOSURE PRESSURE AT FIRE DOORS. <br />5. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR <br />MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE <br />ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 POUNDS. <br />12. ALL DOORS INDICATED AS FIRE-RATED ASSEMBLIES TO HAVE CLOSURES AND SMOKE <br />SEALS. <br />13. ON DOORS IN ALUMINUM FRAMES, PROVIDE ARMORED STRIKE ON JAMB OF ALUMINUM <br />FRAME. <br />14. EXIT DOORS SHALL HAVE A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE <br />DOOR STATING, "THIS DOOR TO REMAINED UNLOCKED DURING BUSINESS HOURS." THE SIGN <br />SHALL HAVE 1" HIGH LETTERS ON A CONTRASTING BACKGROUND. THE LOCKING DEVICE <br />MUST BE OF A TYPE THAT WILL BE READILY DISTINGUISHABLE AS LOCKED. <br />15. DOORS SHALL BE A MINUMUM OF 36" WIDE X 80" HIGH WITH NO SINGLE LEAF EXCEEDING <br />4'-0" IN WIDTH. <br />16. BOTTOM 10" OF DOOR TO HAVE SMOOTH UNINTERUPTED SURFACE FOR OPENING BY <br />WHEELCHAIR FOOT REST. <br />17. CENTER OF HARDWARE TO BE 30" TO 40" ABOVE FLOOR. LATCHING AND LOCKING DOOR <br />TO BE OPERABLE WITH A SINGLE EFFORT BY LEVER OR PUSH-PULL TYPE HARDWARE. <br />18. PROVIDE DOOR SYMBOLS ON DOORWAYS LEADING TO SANITARY FACILITIES (SEE TOILET <br />ROOM DOOR SIGNAGE). CENTER SYMBOLS ON DOORS AT 60" HEIGHT, AND FINISH IN COLOR <br />CONTRASTING TO THAT OF THE DOOR. <br />19. THRESHOLDS SHALL BE 1/2" HIGH MAXIMUM WITH A 2:1 DEGREE BEVELED EDGE. <br />20. THRESHOLD HEIGHT BETWEEN 1/4" AND 1/2" SHALL BE BEVELED AT MAZIMUM 50% SLOPE. <br />21. ALL EXTERIOR DOOR SHALL HAVE PERIMETER DOOR SOUND SEAL/GASKET. <br />22. EACH DOOR IN A MEANS OF EGRESS FROM A GROUP A, OR ASSEMBLY AREA NOT <br />CLASSIFIED AS AN ASSEMBLY OCCUPANCY, HAVING AN OCCUPANT LOAD OF 50 OR MORE <br />SHALL NOT BE PROVIDED WITH A LATCH OR LOCK UNLESS IT IS PANIC HARDWARE OR FIRE <br />EXIT HARDWARE. BUILDING CODE 1008.1.10 FIRE CODE 1008.1.10 <br />DOOR GENERAL NOTES <br />DOOR NOTES LEGEND <br />COMMENTS: <br />DOOR COMMENTS LEGEND <br />1. PROVIDE ELECTRONIC HOLD-OPENS FOR EACH LEAF W/ CONNECTION TO FIRE ALARM. <br />DOOR SCHEDULE <br />DESCRIPTION DATE <br />7/08/24 <br />505 E Central Ave <br />#B11/6/2024